Residential Ventilation Systems

US homes are increasingly being provided with mechanical ventilation systems that are intended to comply with ASHRAE Standard 62.2. As mechanical ventilation is becoming more prevalent, the industry is gaining knowledge about measured installed performance of mechanical ventilation systems and guidance on how to avoid problem installations. Feedback from industry and research studies has led to several key improvements to the ASHRAE standard giving ventilation system designers more flexibility and providing more energy efficient ventilation solutions. This article summarizes some of the key advances in residential ventilation as well as the results of field investigations of residential ventilation system commissioning and operation/maintenance issues, much of which is from the USDOE Building America program.

Lubliner, Michael↗

Characterization of Mechanical Ventilation Systems in New US Homes: What types of systems are out there and are they functioning as intended?

As the airtightness of homes improves to meet energy efficiency goals, it becomes more important for mechanical ventilation systems to help maintain a comfortable and healthy indoor air environment. ASHRAE Standard 62.2 provides national guidance for mechanical ventilation system design and installation, however adoption of those guidelines into local building codes has occurred at different rates. Once provisions for mechanical ventilation are adopted in a local code, are mechanical ventilation systems properly designed, installed, commissioned and operated according to code or above code program requirements? Is there a need for further industry and homeowner education to ensure systems function as intended? This paper presents results from field studies that include characterization of mechanical ventilation systems in over 150 new homes in CA, CO, FL, GA, IL, OR, and SC built between 2011 and 2018. In each of the study homes, airflow of local (kitchen, bathrooms) and whole-house ventilation were measured. Occupant usage of the mechanical ventilation systems were monitored for one week in each home. Installed performance is compared to inferred design intent. The paper also includes homeowner perceptions about, and interactions with, the installed mechanical ventilation systems.

Martin, Eric↗

Impact of Intake and Exhaust Ducts on the Recovery Efficiency of Heat Recovery Ventilation Systems

The heat recovery efficiency of ventilation systems utilizing heat recovery ventilators (HRVs) depends not only on the heat recovery efficiency of the HRV units themselves but also on the intake and exhaust ducts that connect the HRV units to the outside environment. However, these ducts are often neglected in heat loss calculations, as their impact on the overall heat recovery efficiency of HRV systems is often not understood and, to the knowledge of the authors, a mathematical model for the overall heat recovery efficiency of HRV systems that accounts for these ducts has not been published. In this research, a mathematical model for the overall heat recovery efficiency of HRV systems that accounts for the intake and exhaust ducts was derived and validated using real-life data. The model-predicted decrease in heat recovery efficiency due to the ducts was in reasonable agreement (relative error within 20%) with the real-life measurements. The results suggest that utilizing this model allows for more correct ventilation heat loss calculations compared to using the heat recovery efficiency of the HRV unit alone, but more field studies are needed to verify the accuracy of this model in a wide range of applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental evaluation of respiratory droplet spread to rooms connected by a central ventilation system

This article presents results from an experimental study to ascertain the transmissibility of the SARS-CoV-2 virus between rooms in a building that are connected by a central ventilation system. Respiratory droplet surrogates made of mucus and virus mimics were released in one room in a test building and measurements of concentration levels were made in other rooms connected via the ventilation system. The paper presents experimental results for different ventilation system configurations, including ventilation rate, filtration level (up to MERV-13), and fractional outdoor air intake. The most important finding is that respiratory droplets can and do transit through central ventilation systems, suggesting a mechanism for viral transmission (and COVID-19 specifically) within the built environment in reasonable agreement with well-mixed models. We also find the deposition of these droplets on room walls to be negligibly small. Furthermore, the energy use impact of the different configuration settings is also quantified to help inform intelligent building operation that can simultaneously address energy use and occupant health.

60 APPLIED LIFE SCIENCES↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Weather responsive smart ventilation system using multiple optimization parameters

A smart ventilation system which uses outdoor temperature and moisture to optimize control of the system. The main principle is to shift ventilation from time periods that have large indoor-outdoor temperature and moisture differences to periods when these differences are smaller, and their energy and comfort impacts are expected to be less. Fan flow rates are reduced when the outside temperature and moisture falls outside of optimum levels, yet overall air exchange is maintained to ensure chronic and acute exposure to pollutants remains relative to best practice. Online weather and smart thermostat data can be used as control inputs, so no specific measurement devices are needed to control ventilation fans.

Parker, Danny↗

Integrated heat and energy recovery ventilator system

A heat recovery ventilator (HRV) and/or energy recovery ventilator (ERV) that integrates with a residential capacity air handling unit (AHU) is embodied in a small footprint HRV or ERV unit that connects directly to the return side of an AHU and to outdoor air inlet and exhaust ducts. The ventilator includes a control system incorporating a processor and sensors that control the operation of the system to provide desired ventilation flow rates under varying conditions.

Puttagunta, Srikanth↗

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of peak power demand reduction available via modulation of building ventilation systems.

Peak power demand strains electrical grids and increases cost of electricity generation, transmission and distribution infrastructure. Many studies have examined ways of reducing peak power demand, including modification of room air temperature setpoints or reduction of lighting levels. However, very few or no studies have examined the peak power reduction resource offered by temporary curtailment of building ventilation systems. For this reason, we conducted a simulation campaign in which we examined the resource offered by temporary ventilation curtailment in commercial buildings of different use types across the United States and in residences in the state of California, with the essential constraint that any changes resulted in air quality acceptable to occupants through additional ventilation to compensate for the curtailment. To do this, we employed previously validated building models implemented in the airflow and contaminant transport tool CONTAM and building thermal and systems modeling tool EnergyPlus, in some cases co-simulated. Overall, results show savings are highly dependent on building type and climate but range from 0–2 W/ft 2 and up to 40% of total peak building power demand. Depending on building type, this power shed can be conducted for 1.5–8 h before acute exposure or odor concerns are expected, assuming a safety factor of 2. This reduction is of the same magnitude as that offered by thermal control strategies such as setpoint increase, or from lighting reduction strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) Quality Assurance Program - 20237

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous HEPA filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The SSCVS project has proceeded with the awarding of CD-3A for Long Lead Procurements followed by CD-2/3 approval for the construction of the facilities. The SSCVS project team made the decision to increase the quality oversight throughout the complete project per the Project Quality Assurance Plan (PQAP) such that it can ensure the final products meet applicable NQA-1 requirements and general quality requirements, and that the project will proceed to operations without significant delays due to post installation quality concerns. The PQAP was established prior to approval of the project at the CD-2/3 milestone. The SSCVS project has 2 major long lead procurements which commenced with the awarding of CD-3A. These procurements include the HEPA filter housing assemblies and the Exhaust Fans. There are 22 HEPA filter assemblies for the SSCVS, which are designated Safety Significant for pressure boundary confinement, per the approved PDSA. The exhaust fans also have Safety Significant components to maintain the pressure confinement boundary. NWP made the decision to install resident Quality Inspectors at the fabrication facilities to ensure the documentation for each fabricated unit meets all the QA requirements as defined in the respective contract documents. For the construction of the SSCVS Salt Reduction Building (SRB) and New Filter Building (NFB), dedicated, on-site quality inspectors have been utilized to ensure that all work being performed will comply with quality requirements and the Special Inspections as defined in IBC-2015. At each stage of inspection, hold points are placed into the work packages to ensure NWP QA personnel are present to inspect and verify the installations are in accordance with the design specifications, codes and standards. With this level of oversight, NWP anticipates that the level of quality related issues, as seen on multiple other DOE complex site projects, will be avoided and that the commissioning, start-up and hot operations will progress in a timely fashion, as all documentation will be in place and approved prior to initiation of these activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Size dependent infectivity of SARS-CoV-2 via respiratory droplets spread through central ventilation systems

In this work, we evaluate the transport of respiratory droplets that carry SARS-CoV-2 through central air handling systems in multiroom buildings. Respiratory droplet size modes arise from the bronchioles representing the lungs and lower respiratory tract, the larynx representing the upper respiratory tract including vocal cords, or the oral cavity. The size distribution of each mode remains largely conserved, although the magnitude of each droplet mode changes as infected individuals breathe, speak, sing, laugh, cough, and sneeze. Here we evaluate how each type of respiratory droplet transits through central ventilation systems and the implications thereof for infectivity of COVID-19. We find that while larger oral droplets can transmit through the air handling systems, their size and concentration are greatly reduced with but few oral droplets leaving the source room. In contrast, the smaller droplets that originate from the bronchioles and larynx are much more effective in transiting through the air handling system into connected rooms. This suggests that the ratio of lower respiratory or deep lung infections may increase relative to upper respiratory infections in rooms connected by central air handling systems. Also, increasing the temperature and humidity in the range considered after the droplets have achieved an “equilibrium” size reduces the probability of infection.

60 APPLIED LIFE SCIENCES↗

Investigation of potential aerosol transmission and infectivity of SARS-CoV-2 through central ventilation systems

Here we evaluate the concentrations and probabilities of infection for both building interior and exterior exposure sources using a well-mixed model in a connected multizone building. As a central hub of many community and economic activities, buildings provide social connectivity, but the COVID-19 pandemic has reduced social connectivity due to concerns of viral spread within buildings. Although single zone models of infectious spread are well studied, the impact of aerosolized spread of SARS-CoV-2 via air handling systems in multizone buildings remains unexplored. Here we evaluate the influence of filtration, air exchange rates, and the fraction of outdoor air on the probability of infection using the well-known well-mixed modeling approach for a multizone. We find filtration lowers the concentration and probability of infection in both source and connected rooms provided at least some air is recirculated, but that probability is not zero. Filtration has no influence without recirculation or unless the outdoor air contains virus. We find that increasing the air exchange rate removes virus from the source room faster but also increases the rate of exposure to connected rooms. Therefore, slower air exchange rates reduce infectivity in connected rooms at shorter durations, but higher air exchange rates reduce infectivity at longer durations. We further find that when outdoor air is virus free, increasing the fraction of outdoor air is helpful, but, when outdoor air is infective, pathogen exposure inside can persist for hours after a short-term release.

60 APPLIED LIFE SCIENCES↗

Crankcase ventilation systems

An internal combustion engine may be used to compress natural gas for vehicle fuel. The engine may contain a plurality of gas compression cylinders, at least one standard combustion cylinder to drive the compression cylinders, and a common crankshaft in a crankcase coupling the compression cylinders and the at least one standard combustion cylinder. Some combustible gas being compressed may leak past the piston rings of the compression cylinders into the engine crankcase posing a safety concern. This invention eliminates this concern by actively flushing the crankcase at a higher rate than normal.

Babbitt, Guy Robert↗

Crankcase ventilation system with dead space alignment sleeves

A cylinder aligning sleeve and adapter plate for use within an internal combustion engine. The sleeve includes apertures placed contiguously with holes within the adapter plate to form a flow passage through the dead space between compression and crosshead pistons. The flow passage exits to a vent line where gas detection may occur along with safe venting of any gas detected. The sleeve serves to ensure concentric alignment of the compression cylinder with the engine block bore.

Alvarado, Caleb A.↗