Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Condensing Furnace Venting Part 2: Evaluation of Same-Chimney Vent Systems for Condensing Furnaces and Natural Draft Water Heaters

In 1987, the National Appliance Energy Conservation Act prescribed the first federal minimum energy conservation standard for natural gas furnaces at an annual fuel utilization efficiency of 78%, effective January 1, 1992. One of the techno-economic issues that has prevented higher furnace efficiency standards since then is the lack of cost-effective, simple, and safe solutions that enable condensing furnaces and atmospheric combustion water heaters to vent through the same existing chimney. Part 1 of this two-part report series, published in October 2014, documents the issue, prospective solutions, and a test laboratory established to evaluate prospective venting solutions. This part 2 report documents the updated prospective solutions (because they have evolved since part 1 was written), the methodology for experimentally evaluating prospective solutions, and results of the evaluations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental quantification of vent mechanism flow parameters in 18650 format lithium ion batteries

Lithium ion batteries have a well documented tendency to fail energetically under various abuse conditions. These conditions frequently result in decomposition of the electrochemical components within the battery resulting in gas generation and increased internal pressure which can lead to an explosive case rupture. The 18650 format cell incorporates a vent mechanism located within a crimped cap to relieve pressure and mitigate the risk of case rupture. Cell venting, however, introduces additional safety concerns associated with the flow of flammable gases and liquid electrolyte into the environment. Experiments to quantify key parameters are performed to elucidate the external dynamics of battery venting. A first experiment measures the vent burst pressure. Burst vent caps are then tested with a second experimental fixture to measure vent opening area and discharge coefficient during choked-flow venting, which occurs during battery failure. Vent opening area and discharge coefficient are calculated from stagnation temperature, stagnation pressure, and static pressure measurements along with compressible-isentropic flow equations and conservation of mass. Commercially-sourced vent caps are used with repeated tests run to quantify repeatability and variability. Validation experiments confirmed accuracy of opening area and discharge coefficient measurement. Moreover, trials conducted on vent caps from two sources demonstrate the potential for variation between manufacturers.

25 ENERGY STORAGE↗

Furnace and Water Heater Venting Field Demonstration

A field demonstration was performed to evaluate the venting performance of the M&G DuraVent FasNSeal 80/90 venting system. The venting system uses a unique pipe within a pipe design to vent a condensing furnace and an natural-draft water heater, and can enable a condensing furnace to be installed in a home in which a condensing furnace could not otherwise be installed due to venting constraints. The field demonstration found that the FasNSeal 80/90 venting system successfully vented the orphaned water heater in each of the 16 demonstration homes and that the venting performance of the FasNSeal 80/90 venting system is generally comparable to the performance of venting systems initially installed in the 16 homes.

42 ENGINEERING↗

Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting

BSC TO5 Task 2.5 Field Testing of an Un-vented Roof with Fibrous Insulation and Tiles - Winter Park, FL 32789 Field test data available for wood moisture contents, temperature, and relative humidity. Un-vented roofs (aka cathedral-ized attics) are an established presence in Florida residential building markets. These roofs are built with a layer of spray polyurethane foam (SPF) on the underside of the roof deck. Such a roof configuration positions the heating, ventilating, and air-conditioning equipment and ductwork within the conditioned space and improves airtight-ness in practice (by shifting the air barrier from the ceiling to the roofline). However, SPF is more expensive than fibrous insulation. Some builders have also become wary of using SPF because of liability concerns about indoor air quality and off-gassing. Unfortunately, un-vented roofs that use only air-permeable fibrous insulation (cellulose or fiberglass) have been demonstrated to be at risk of moisture issues in climate zone 2A because condensation and moisture accumulation occur at the ridge. This report describes research about a test implementation of an un-vented tile roof assembly in a hot-humid climate (Orlando, Florida; climate zone 2A); the roof was insulated with air-permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous work, the U.S. Department of Energy's Building America research team Building Science Corporation theorized that installation of diffusion vents might allow for the wintertime release of moisture to safe levels. Diffusion vents are open slots at the roof's highest points (the ridge and hips) that are covered with a water-resistant but vapor-open (500+ perm) air barrier membrane. The test home is a two-story slab-on-grade structure (3,600 ft2 ); the roof was insulated with a prototype insulation system (called boxed netting), which allows full depth insulation (i.e., it is not limited by the depth of the truss top chord). As a control comparison, one part of the roof was constructed as a typical un-vented roof (with a self-adhered membrane at the ridge). Ideally, failure would occur in the control roof and the experimental (diffusion vent) roofs would show sufficient drying to avoid failure. No intentional space conditioning was provided in the un-vented attic so worst-case humidity buildup conditions could be observed.

air leakage↗

Examination of entrainment, combustibility, and heat transfer due to cell venting inside simplified battery energy storage enclosures

Battery energy storage systems (ESS) assembled of modules containing lithium-ion batteries can pose fire and explosion hazards during thermal runaway because vented gases may accumulate, combust, or escape enclosures. Here, we propose a prototypical configuration composed of the main components of an ESS rack, where modules are represented as rectangles within an enclosure and vent gas is injected steadily through the top of a module. This idealized geometry allows for exploration of how rack-level characteristics can influence smaller single-cell or module-level scales. Through this geometry, we conduct numerical simulations to understand how variations in the vent velocity, temperature, and vertical location affect entrainment rates, fraction of uncombusted fuel, rich-gas coverage, and heat flux to other modules. At lower vent velocities and vertical positions, buoyancy drives enough entrainment and mixing to react with most of the vent gases on the converging plenum. As jet momentum increases and/or buoyancy decreases via higher vent position in the rack, vent gases can propagate into and burn in the divergence plenum. Heat flux to the impinged module scales strongly with vent momentum and temperature, while heat transfer to upper modules peaks when flames in the diverging plenum reach the surface and declines when combustion is suppressed.

Computational fluid dynamics↗

Microbial communities of Auka hydrothermal sediments shed light on vent biogeography and the evolutionary history of thermophily

Abstract Hydrothermal vents have been key to our understanding of the limits of life, and the metabolic and phylogenetic diversity of thermophilic organisms. Here we used environmental metagenomics combined with analysis of physicochemical data and 16S rRNA gene amplicons to characterize the sediment-hosted microorganisms at the recently discovered Auka vents in the Gulf of California. We recovered 325 metagenome assembled genomes (MAGs) representing 54 phyla, over 30% of those currently known, showing the microbial community in Auka hydrothermal sediments is highly diverse. 16S rRNA gene amplicon screening of 224 sediment samples across the vent field indicates that the MAGs retrieved from a single site are representative of the microbial community in the vent field sediments. Metabolic reconstruction of a vent-specific, deeply branching clade within the Desulfobacterota suggests these organisms metabolize sulfur using novel octaheme cytochrome-c proteins related to hydroxylamine oxidoreductase. Community-wide comparison between Auka MAGs and MAGs from Guaymas Basin revealed a remarkable 20% species-level overlap, suggestive of long-distance species transfer over 400 km and subsequent sediment colonization. Optimal growth temperature prediction on the Auka MAGs, and thousands of reference genomes, shows that thermophily is a trait that has evolved frequently. Taken together, our Auka vent field results offer new perspectives on our understanding of hydrothermal vent microbiology.

54 ENVIRONMENTAL SCIENCES↗

Global patterns of diversity and metabolism of microbial communities in deep-sea hydrothermal vent deposits

When deep-sea hydrothermal fluids mix with cold oxygenated fluids, minerals precipitate out of solution and form hydrothermal deposits. These actively venting deep-sea hydrothermal deposits support a rich diversity of thermophilic microorganisms which are involved in a range of carbon, sulfur, nitrogen, and hydrogen metabolisms. Global patterns of thermophilic microbial diversity in deep-sea hydrothermal ecosystems have illustrated the strong connectivity between geological processes and microbial colonization, but little is known about the genomic diversity and physiological potential of these novel taxa. Here we explore this genomic diversity in 42 metagenomes from four deep-sea hydrothermal vent fields and a deep-sea volcano collected from 2004 to 2018 and document their potential implications in biogeochemical cycles. Our dataset represents 3635 metagenome-assembled genomes encompassing 511 novel and recently identified genera from deep-sea hydrothermal settings. Some of the novel bacterial (107) and archaeal genera (30) that were recently reported from the deep-sea Brothers volcano were also detected at the deep-sea hydrothermal vent fields, while 99 bacterial and 54 archaeal genera were endemic to the deep-sea Brothers volcano deposits. We report some of the first examples of medium- (≥ 50% complete, ≤ 10% contaminated) to high-quality (> 90% complete, < 5% contaminated) MAGs from phyla and families never previously identified, or poorly sampled, from deep-sea hydrothermal environments. We greatly expand the novel diversity of Thermoproteia, Patescibacteria (Candidate Phyla Radiation, CPR), and Chloroflexota found at deep-sea hydrothermal vents and identify a small sampling of two potentially novel phyla, designated JALSQH01 and JALWCF01. Metabolic pathway analysis of metagenomes provides insights into the prevalent carbon, nitrogen, sulfur, and hydrogen metabolic processes across all sites and illustrates sulfur and nitrogen metabolic “handoffs” in community interactions. We confirm that Campylobacteria and Gammaproteobacteria occupy similar ecological guilds but their prevalence in a particular site is driven by shifts in the geochemical environment. Our study of globally distributed hydrothermal vent deposits provides a significant expansion of microbial genomic diversity associated with hydrothermal vent deposits and highlights the metabolic adaptation of taxonomic guilds. Collectively, our results illustrate the importance of comparative biodiversity studies in establishing patterns of shared phylogenetic diversity and physiological ecology, while providing many targets for enrichment and cultivation of novel and endemic taxa.

59 BASIC BIOLOGICAL SCIENCES↗

Radio Frequency Characteristics of Volcanic Lightning and Vent Discharges

In this study, we analyze the pulse width and spectral content of vent discharges and volcanic lightning flashes. We made measurements of electrical activity with a broadband very high frequency antenna (20–80 MHz) during an explosive eruption of Sakurajima volcano on November 8, 2019. The individual impulses that comprise vent discharges and volcanic lightning were analyzed to determine the fundamental width of the impulses and the rate of fall-off of their energy spectral density. The results show that vent discharges are more similar to volcanic lightning than they are different. Here, the mean pulse width for both vent discharges and volcanic lightning was 50 ns. Both types of electrical activity had similar spectral content; the average slope of the amplitude spectra was –3.4 for both. Further, examination of the pulse width and spectral slope distributions showed that while the distributions of volcanic lightning and vent discharges are statistically distinct from each other, the distribution of vent discharges is a subset of the distribution of volcanic lightning.

58 GEOSCIENCES↗

Assessment of Literature Related to Combustion Appliance Venting Systems

In many residential building retrofit programs, air tightening to increase energy efficiency is often constrained by safety concerns with naturally vented combustion appliances. Tighter residential buildings more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spill combustion exhaust into the living space. Several measures, such as installation guidelines, vent sizing codes, and combustion safety diagnostics, are in place with the intent to prevent backdrafting and combustion spillage, but the diagnostics conflict and the risk mitigation objective is inconsistent. This literature review summarizes the metrics and diagnostics used to assess combustion safety, documents their technical basis, and investigates their risk mitigations. It compiles information from the following: codes for combustion appliance venting and installation; standards and guidelines for combustion safety diagnostics; research evaluating combustion safety diagnostics; research investigating wind effects on building depressurization and venting; and software for simulating vent system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility and Safety Assessment for Advanced Reactor Concepts Using Vented Fuel

Recent interest in fast reactor technology has led to renewed analysis of past reactor concepts such as Gas Fast Reactors and Sodium Fast Reactors. In an effort to make these reactors more economic, the fuel is required to stay in the reactor for extended periods of time; the longer the fuel stays within the core, the more fertile material is converted into usable fissile material. However, as burnup of the fuel-rod increases, so does the internal pressure buildup due to gaseous fission products. In order to reach the 30 year lifetime requirements of some reactor designs, the fuel pins must have a vented-type design to allow the buildup of fission products to escape. The present work aims to progress the understanding of the feasibility and safety issues related to gas reactors that incorporate vented fuel. The work was separated into three different work-scopes: 1. Quantitatively determine fission gas release from uranium carbide in a representative helium cooled fast reactor; 2. Model the fission gas behavior, transport, and collection in a Fission Product Vent System; and, 3. Perform a safety analysis of the Fission Product Vent System. Each task relied on results from the previous task, culminating in a limited scope Probabilistic Risk Assessment (PRA) of the Fission Product Vent System. Within each task, many key parameters lack the fidelity needed for comprehensive or accurate analysis. In the process of completing each task, the data or methods that were lacking were identified and compiled in a Gap Analysis included at the end of the report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ephemerality of discrete methane vents in lake sediments

Methane is a potent greenhouse gas whose emission from sediments in inland waters and shallow oceans may both contribute to global warming and be exacerbated by it. The fraction of methane emitted by sediments that bypasses dissolution in the water column and reaches the atmosphere as bubbles depends on the mode and spatiotemporal characteristics of venting from the sediments. Earlier studies have concluded that hot spots—persistent, high-flux vents—dominate the regional ebullitive flux from submerged sediments. Here the spatial structure, persistence, and variability in the intensity of methane venting are analyzed using a high-resolution multibeam sonar record acquired at the bottom of a lake during multiple deployments over a 9 month period. We confirm that ebullition is strongly episodic, with distinct regimes of high flux and low flux largely controlled by changes in hydrostatic pressure. Our analysis shows that the spatial pattern of ebullition becomes homogeneous at the sonar's resolution over time scales of hours (for high-flux periods) or days (for low-flux periods), demonstrating that vents are ephemeral rather than persistent, and suggesting that long-term, lake-wide ebullition dynamics may be modeled without resolving the fine-scale spatial structure of venting.

54 ENVIRONMENTAL SCIENCES↗

Using Multiscale Ethane/Methane Observations to Attribute Coal Mine Vent Emissions in the San Juan Basin From 2013 to 2021

Abstract Source attribution of natural gas emissions from fossil fuels in New Mexico's San Juan Basin (SJB) is challenging due to source heterogeneity and emissions transience. We demonstrate that ethane (C 2 H 6 ) to methane (CH 4 ) mixing ratios can identify and separate sources over different scales using various measurement techniques. We report simultaneous CH 4 and C 2 H 6 observations near a coal mine vent and oil and gas (O&G) emission sources using ground‐based in situ measurements in 2020/2021. During these campaigns, we observed a stable coal vent C 2 H 6 :CH 4 ratio of 1.28% ± 0.11%, discernibly different than nearby O&G source ratios ranging from 0.9% to 16.8%. We analyze airborne observations of the SJB taken in 2014/2015 that exhibit similar coal vent ratios and further show the region's heterogeneity. We identify episodic O&G sources, including a gas plant source detected in 2014/2015 that is absent in our 2020/2021 data. We examine total column observations of C 2 H 6 and CH 4 made in 2013 with a solar spectrometer and find a C 2 H 6 :CH 4 ratio of 1.3% ± 0.4% for the coal vent. The stable and unique coal vent ratio relative to other O&G sources in the region is used to demonstrate that consistent attribution is possible using various measurement methods at multiple scales across many years. Finally, we demonstrate that using C 2 H 6 as a proxy for fossil CH 4 inversions can inform detailed basin‐scale inversions, provided we understand source specific changes in the C 2 H 6 :CH 4 ratio like we report in the SJB.

54 ENVIRONMENTAL SCIENCES↗

ALARA Review for Venting of Flanged Tritium Waste Containers (FTWCs) at TA-54

This project will vent headspace hydrogen and oxygen from specialized high-pressure storage vessels called flanged tritium waste containers (FTWCs). There are four of these containers located in Los Alamos National Laboratory’s (LANL’s) Technical Area 54 (TA-54), Building 1028. This building is in the southwest corner of LANL’s Material Disposal Area G. The vented headspace gas is expected to contain tritium in the form of water vapor, elemental hydrogen or a combination of both. The venting operation is expected to take place in 2025. There will be a series of operational readiness reviews prior to venting activities commencing. The FTWCs at TA-54 contain tritium-contaminated metal parts and molecular sieve media, which is a pebble-like material used to absorb water vapor from the air. This molecular sieve media inside the FTWCs is contained in metal canisters, along with some loose media material in bags. Over time, tritiated water vapor that had been adsorbed onto the media can become liberated into the FTWC headspace gas. Radiolysis can cause separation of the water vapor into its hydrogen and oxygen components, resulting in the potentially hazardous gas mixture within the FTWC. LANL has determined that continued tritium storage in these containers can pose an unsafe condition due to possible hydrogen and oxygen gas buildup within the FTWCs with a potential for explosion if sparks are generated within the FTWCs. To mitigate this hazard, the FTWCs will be stabilized by venting them in-place to remove hazardous gases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hardened Containment Vent System Dose Considerations for FLEX

Fukushima lessons learned include adding diverse and flexible mitigation strategies, or FLEX, that will increase defense-in-depth for beyond-design-basis (BDB) scenarios to address an Extended Loss of AC Power (ELAP). FLEX and NRC order EA-13-109 require improvements to the reliability of Hardened Containment Vent Systems (HCVS) for Mark I and II boiling water reactors (BWR) for venting of the core under severe accident conditions. NEI HCVSWP-02 provides generic guidance to determine radiological dose from HCVS piping. This paper presents a more refined analysis tool and method to assess the doses from the HCVS piping resulting from a failed core during an ELAP for a representative Mark I BWR. The dose rates up to 4' from the HCVS pipe at 8 hours after ELAP and over time at 3' are provided for the different cases. HCVS pipe length can affect dose rates farther from the pipe. As expected, dose rates versus time for representative plant case 2 drop off quickly as the HCVS activity is vented out. The dose rate results show that significant protection for personnel would be required in the areas near HCVS piping during certain time frames of containment venting. Equipment in the vicinity of the vent piping should also be evaluated for impact of radiation exposure. The results for the representative plant cases are higher and lower than the scaled NEI results depending on the model assumptions, limitations and considerations which can change as the HCVS design evolves. Using the NEI paper with scaling factors may not be conservative for all applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Residual Dose Rates Analyses from Vent Lines Shield Block on the Target Cart at Spallation Neutron Source

The target carriage supports the mercury target vessel in the Spallation Neutron Source (SNS) in a cantilevered fashion and supplies the liquid mercury flowing to and from the target vessel. The target carriage is designed to move the target vessel into its target monolith position to receive the proton beam and then remove it horizontally back into an adjacent service cell, where the target vessel can be exchanged about 2-3 times per calendar year. At the time of the performed studies, the SNS mercury target can accept a proton beam at 1 GeV energy and 1.4 MW power; however, it will be upgraded to receive 1.3 GeV energy at 2 MW by the end of 2024 year [1]. The cart is practically a shield block on wheels to minimize fluxes and dose rates in the service cell downstream of the carriage. There are vent lines located inside a passage on top of the target carriage, and they are covered by a stepping-up steel shield block (vent lines shield block). Vent lines are permanently attached to the shield block. New vent lines with a different design are going to be installed. These lines are shielded by the new steel block to which the vent lines are attached. The estimate of the residual dose rates from the block after it is extracted from the target carriage is performed to estimate the radiation fields and to decide on the type of storage container to be used.

Popova, Irina I↗

Measure Guideline: Passive Vents

This document addresses the use of passive vents as a source of outdoor air in multifamily buildings. The challenges associated with implementing passive vents and the factors affecting performance are outlined. A comprehensive design methodology and quantified performance metrics are provided. Two hypothetical design examples are provided to illustrate the process. This document is intended to be useful to designers, decision-makers, and contractors implementing passive ventilation strategies. It is also intended to be a resource for those responsible for setting high-performance building program requirements, especially pertaining to ventilation and outdoor air. To ensure good indoor air quality, a dedicated source of outdoor air is an integral part of high-performance buildings. Presently, there is a lack of guidance pertaining to the design and installation of passive vents, resulting in poor system performance. This report details the criteria necessary for designing, constructing, and testing passive vent systems to enable them to provide consistent and reliable levels of ventilation air from outdoors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗