Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VELOCIMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development Of A Photonic Doppler Velocimeter To Verify A Fabry-Perot Velocimeter

The laser shock system uses acoustic shockwaves to measure the interface strength of newly designed nuclear fuel plates. The quantitative measurement of interface strength will help understand fuel performance during irradiation. The laser shock technique imparts laser energy into a plate that then creates an acoustic shockwave. The amount of energy in the plate is proportional to the surface velocities measured on the back side of the plate. An accurate determination of surface velocity will enable better fuel performance predictions. The focus of this paper is on the implementation of a Photonic Doppler Velocimeter to corroborate the Fabry-Perot measurements from the laser shock system. Currently, a Fabry-Perot velocimeter takes the velocity measurements that are converted in stress. We have designed and implemented a Photonic Doppler Velocimeter to corroborate the Fabry-Perot measurements, which we discuss here along with implementing the short time fast Fourier transform to demodulate the heterodyne beat frequency into velocities. The Photonic Doppler Velocimeter has successfully corroborated the Fabry-Perot measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IMPROVED BAR IMPACT TESTS USING A PHOTONIC DOPPLER VELOCIMETER

Bar impact tests, using the techniques described elsewhere in this symposium, were used to measure compressive and tensile strengths of borosilicate glass, soda lime glass, and a glass ceramic. The glass ceramic was 25% crystalline spinel, furnished by Corning Inc. There are two measures of compressive strength: the peak stress that can be transmitted in unconfined compression, and the 'steady state' strength. For borosilicate glass and soda lime glass, these values were similar, being about 1.8 and 1.5 GPa, respectively. The glass ceramic (25% spinel) was almost 50% stronger. Tensile failure in the glass and glass ceramic takes places via surface flaws, and thus tensile strength is an extrinsic, as opposed to intrinsic property.

36 MATERIALS SCIENCE↗

Optic-microwave mixing velocimeter for superhigh velocity measurement

The phenomenon that a light beam reflected off a moving object experiences a Doppler shift in its frequency underlies practical interferometric techniques for remote velocity measurements, such as velocity interferometer system for any reflector (VISAR), displacement interferometer system for any reflector (DISAR), and photonic Doppler velocimetry (PDV). While VISAR velocimeters are often bewildered by the fringe loss upon high-acceleration dynamic process diagnosis, the optic-fiber velocimeters such as DISAR and PDV, on the other hand, are puzzled by high velocity measurement over 10 km/s, due to the demand for the high bandwidth digitizer. Here, we describe a new optic-microwave mixing velocimeter (OMV) for super-high velocity measurements. By using currently available commercial microwave products, we have constructed a simple, compact, and reliable OMV device, and have successfully obtained, with a digitizer of bandwidth 6 GH only, the precise velocity history of an aluminum flyer plate being accelerated up to 11.2 km/s in a three stage gas-gun experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Embedded Fiber Optic Probes to Measure Detonation Velocities Using the Photonic Doppler Velocimeter

Detonation velocities for high explosives can be in the 7 to 8 km/s range. Previous work has shown that these velocities may be measured by inserting an optical fiber probe into the explosive assembly and recording the velocity time history using a Fabry-Perot velocimeter. The measured velocity using this method, however, is the actual velocity multiplied times the refractive index of the fiber core, which is on the order of 1.5. This means that the velocimeter diagnostic must be capable of measuring velocities as high as 12 km/s. Until recently, a velocity of 12 km/s was beyond the maximum velocity limit of a homodyne-based velocimeter. The limiting component in a homodyne system is usually the digitizer. Recently, however, digitizers have come on the market with 20 GHz bandwidth and 50 GS/s sample rate. Such a digitizer coupled with high bandwidth detectors now have the total bandwidth required to make velocity measurements in the 12 km/s range. This paper describes measurements made of detonation velocities using a high bandwidth homodyne system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise correction of turbulent spectra obtained from Acoustic Doppler Velocimeters

Accurately estimated auto-spectral density functions are essential for characterization of turbulent flows, and they also have applications in computational fluid dynamics modeling, site and inflow characterization for hydrokinetic turbines, and inflow turbulence generation. The Acoustic Doppler Velocimeter (ADV) provides single-point temporally resolved data, that are used to characterize turbulent flows in rivers, seas, and oceans. However, ADV data are susceptible to contamination from various sources, including instrument noise, which is the intrinsic limit to the accuracy of acoustic velocity measurements. Due to the presence of instrument noise, the spectra obtained are altered at high frequencies. The focus of this study is to develop a robust and effective method for accurately estimating auto-spectral density functions from ADV data by reducing or removing the spectral contribution derived from instrument noise. For this purpose, the “Noise Auto-Correlation” (NAC) approach was developed, which exploits the correlation properties of instrument noise to identify and remove its contribution from spectra. The spectra estimated using the NAC approach exhibit increased fidelity and a slope of -5/3 in the inertial range, which is typically observed for turbulent flows. Finally, this study also compares the effectiveness of low-pass Gaussian filters in removing instrument noise with that of the NAC approach. For the data used in this study, both the NAC and Gaussian filter approaches are observed to be capable of removing instrument noise at higher frequencies from the spectra. However, the NAC results are closer to the expected frequency power of -5/3 in the inertial sub-range.

Acoustic Doppler Velocimeter↗

Shock loading characteristics of Zr and Ti metals using dual beam velocimeter

The characteristics of titanium and zirconium metal foils under shock loading have been studied up to 16 GPa and 12 GPa pressure, respectively, using portable electric gun setup as projectile launcher. In these experiments, the capabilities of a single Fabry-Perot velocimeter have been enhanced by implementing it in dual beam mode to record the two velocity profiles on a single streak camera. The measured equation of state data for both the metals have been found to be well in agreement with the reported Hugoniot, within experimental accuracies. A phase transition from α to ω phase has been detected near to 11.4 GPa for titanium and 8.2 GPa for zirconium in the rising part of target-glass interface velocity profile.

36 MATERIALS SCIENCE↗

Imaging doppler velocimeter with downward heterodyning in the optical domain

In a Doppler velocimeter, the incoming Doppler-shifted beams are heterodyned to reduce their frequencies into the bandwidth of a digital camera. This permits the digital camera to produce at every sampling interval a complete two-dimensional array of pixel values. This sequence of pixel value arrays provides a velocity image of the target.

47 OTHER INSTRUMENTATION↗

Remote Fiber Based Velocimeter For Interface Strength Measurements

The understanding of the performance of nuclear reactor plate fuels is essential when developing new fuel systems. The condition of pre and post irradiated plate fuels must be characterized effectively and efficiently prior to irradiation and then post irradiation within a high rad environment. The post characterization work must be performed remotely and in an environment hostile to instrumentation. Laser based characterization methods provide the capability to be remote and robust within a hot-cell environment. Laser based characterization can provide high spatial resolution appropriate for scanning and imaging large areas. The INL is currently developing a laser shock system for Post Irradiation Examination (PIE) station for use in the Hot Fuel Examination Facility (HFEF) at the INL. The laser shock system is designed to characterize fuel to cladding and cladding to cladding interface strength. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel-clad interface. The shock wave propagates as a compressional wave through the fuel plate to the free (unconfined) backside surface and is reflected back through the test plate as a rarefaction (tensile) wave. This rarefaction wave is the physical mechanism that produces internal delamination failure. The focus or this paper is on the accurate measurement of surface velocity to quantify the amount of energy traveling through the interfaces to the back surface of the fuel plate. The original fiber based velocimeter design was biased by parasitic back reflections. This paper will discuss the discovery of the back-reflection issue and the design changes to resolve the issue. Supporting data will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Acoustic Doppler Velocimeter (ADV) data from the University of New Hampshire Atlantic Marine Energy Center (UNH-AMEC ) Tidal Energy Test Site during a Perigean Spring Tide

The ADV measurements contained in this submission were taken on the floating turbine deployment platform (TDP) located at the Memorial Bridge in Portsmouth, NH. The measurements were conducted 11/4/2021-11/9/2021 with the fastest currents occurring on 11/7/2021. Along with the submission of ADV data, a .ppt and text document further explaining the ADV deployment location is included.

16 TIDAL AND WAVE POWER↗

A high-resolution two-dimensional imaging velocimeter

Velocity interferometers are typically used to measure velocities of surfaces at a single point or along an imaged line as a function of time. We describe an optical arrangement that enables high-resolution measurements of the two-dimensional velocity field across a shock front or shocked interface. The technique is employed to measure microscopic fluctuations in shock fronts that have passed through materials being considered as ablators for indirect-drive inertial confinement fusion. With picosecond time resolution the instrument captures velocity modes with wavelengths as short as 2.5 {mu}m at a resolution of {approx}10 m/s rms on velocity fields averaging many km/s over an 800 {mu}m field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed nanometer-resolved imaging vibrometer and velocimeter

Conventional laser vibrometers are incapable of performing multidimensional vibrometry at high speeds because they build on single-point measurements and rely on beam scanning, significantly limiting their utility and precision. Here we introduce a laser vibrometer that performs high-speed multidimensional imaging-based vibration and velocity measurements with nanometer-scale axial resolution without the need for beam scanning. As a proof-of-concept, we demonstrate real-time microscopic imaging of acoustic vibrations with 1 nm axial resolution, 1200 image pixels, and 30 ps dwell time at 36.7 MHz scan rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A particle image velocimeter for measuring the output of high energy detonators

Results from feasibility experiments are presented to confirm that tracer-particle motion resulting from mass-velocity fields created by driving high-energy detonator output into dynamic witness plates can be successfully measured using particle image velocimetry (PIV). Experimental results, application challenges, and PIV system development are presented. In shock mechanics research, the ability to quantitatively measure the state of compression of shocked materials in two and three dimensions based on particle tracer methods is of extreme importance since such measurements provide precise temporal snapshots of two and three-dimensional shock-induced velocity fields. This is especially true in the science of detonation physics where such measurements provide enormous insight into fundamental. questions for understanding shock-loading processes, effects of shock-front curvature, and mechanisms of energy conversion from stimulus to shock output. As an example, answering such questions is paramount to the understanding and development of newer, safer detonators. To date, few attempts have been made to develop and implement standard particle tracer techniques to measure shock-induced flows resulting from explosive devices. The experimental challenge lies in developing a methodology wherein a tracer particle's inertia does not hinder its ability to accurately move with the rapidly changing flow field. We have recently developed the ability to characterize the output of unloaded explosive initiators (e.g. exploding bridge wires, exploding foils, laser-driven plasmas, etc.) using an optically-based diagnostic consisting of an ultra-high speed, time-resolved PIV system and inert, transparent polymers serving as dynamic witness plates. Initiator output is directed into a witness plate, and measurements of shock and mass velocities are made in a two-dimensional plane aligned with the initiator centerline. The results allow initiator output to be quantified in any in-plane direction, typically along the centerline. The successful development and implementation of the new diagnostic to unloaded initiators provides the groundwork for characterizing full-up detonators employing high explosives (HE).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Measuring Turbulence from Moored Acoustic Doppler Velocimeters. A Manual to Quantifying Inflow at Tidal Energy Sites

This work details a methodology for measuring hub height inflow turbulence using moored acoustic Doppler velocimiters (ADVs). This approach is motivated by the shortcomings of alternatives. For example, remote velocity measurements (i.e., from acoustic Doppler profilers) lack sufficient precision for device simulation, and rigid tower-mounted measurements are very expensive and technically challenging in the tidal environment. Moorings offer a low-cost, site-adaptable and robust deployment platform, and ADVs provide the necessary precision to accurately quantify turbulence.

16 TIDAL AND WAVE POWER↗