Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

WE-G-BRD-06: Volumetric Cine MRI (VC-MRI) Estimated Based On Prior Knowledge for On-Board Target Localization

Purpose: To develop a technique to generate on-board VC-MRI using patient prior 4D-MRI, motion modeling and on-board 2D-cine MRI for real-time 3D target verification of liver and lung radiotherapy. Methods: The end-expiration phase images of a 4D-MRI acquired during patient simulation are used as patient prior images. Principal component analysis (PCA) is used to extract 3 major respiratory deformation patterns from the Deformation Field Maps (DFMs) generated between end-expiration phase and all other phases. On-board 2D-cine MRI images are acquired in the axial view. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI at the end-expiration phase. The DFM is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by matching the corresponding 2D slice of the estimated VC-MRI with the acquired single 2D-cine MRI. The method was evaluated using both XCAT (a computerized patient model) simulation of lung cancer patients and MRI data from a real liver cancer patient. The 3D-MRI at every phase except end-expiration phase was used to simulate the ground-truth on-board VC-MRI at different instances, and the center-tumor slice was selected to simulate the on-board 2D-cine images. Results: Image subtraction of ground truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground truth with prior image. Excellent agreement between profiles was achieved. The normalized cross correlation coefficients between the estimated and ground-truth in the axial, coronal and sagittal views for each time step were >= 0.982, 0.905, 0.961 for XCAT data and >= 0.998, 0.911, 0.9541 for patient data. For XCAT data, the maximum-Volume-Percent-Difference between ground-truth and estimated tumor volumes was 1.6% and the maximum-Center-of-Mass-Shift was 0.9 mm. Conclusion: Preliminary studies demonstrated the feasibility to estimate real-time VC-MRI for on-board target localization before or during radiotherapy treatments. National Institutes of Health Grant No. R01-CA184173; Varian Medical System.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-09: A Novel Method of Generating Ultrafast Volumetric Cine MRI (VC-MRI) Using Prior 4D-MRI and On-Board Phase-Skipped Encoding Acquisition for Radiotherapy Target Localization

Purpose: To develop a technique generating ultrafast on-board VC-MRI using prior 4D-MRI and on-board phase-skipped encoding k-space acquisition for real-time 3D target tracking of liver and lung radiotherapy. Methods: The end-of-expiration (EOE) volume in 4D-MRI acquired during the simulation was selected as the prior volume. 3 major respiratory deformation patterns were extracted through the principal component analysis of the deformation field maps (DFMs) generated between EOE and all other phases. The on-board VC-MRI at each instant was considered as a deformation of the prior volume, and the deformation was modeled as a linear combination of the extracted 3 major deformation patterns. To solve the weighting coefficients of the 3 major patterns, a 2D slice was extracted from VC-MRI volume to match with the 2D on-board sampling data, which was generated by 8-fold phase skipped-encoding k-space acquisition (i.e., sample 1 phase-encoding line out of every 8 lines) to achieve an ultrafast 16–24 volumes/s frame rate. The method was evaluated using XCAT digital phantom to simulate lung cancer patients. The 3D volume of end-ofinhalation (EOI) phase at the treatment day was used as ground-truth onboard VC-MRI with simulated changes in 1) breathing amplitude and 2) breathing amplitude/phase change from the simulation day. A liver cancer patient case was evaluated for in-vivo feasibility demonstration. Results: The comparison between ground truth and estimated on-board VC-MRI shows good agreements. In XCAT study with changed breathing amplitude, the volume-percent-difference(VPD) between ground-truth and estimated tumor volumes at EOI was 6.28% and the Center-of-Mass-Shift(COMS) was 0.82mm; with changed breathing amplitude and phase, the VPD was 8.50% and the COMS was 0.54mm. The study of liver patient case also demonstrated a promising in vivo feasibility of the proposed method Conclusion: Preliminary results suggest the feasibility to estimate ultrafast VC-MRI for on-board target localization with phase skipped-encoding k-space acquisition. Research grant from NIH R01-184173.

60 APPLIED LIFE SCIENCES↗

The hydration, microstructure, and mechanical properties of vaterite calcined clay cement (VC 3 )

Limestone (calcite) calcined clay cement (LC 3 ) is a promising low-CO 2 binder, but the low activity of calcite cannot compensate the reduction in clinker factor, resulting in low one-day strength and limiting its broad applications. As recent carbon capture and utilization technologies allow scalable production of vaterite, a more reactive CaCO 3 polymorph, we overcome the challenge by introducing vaterite calcined clay cement (VC 3 ), inspired by the vaterite-calcite phase change. In the present study, VC 3 exhibits higher compressive strengths and faster hydration than LC 3 . Compared to hydrated LC 3 , hydrated VC 3 exhibits increased amount of hemi- and mono-carboaluminate formation and decreased amount of strätlingite formation. With gypsum adjustment, the 1-day strength of VC 3 is higher than that of pure cement reference. Finally, VC 3 , a low-CO 2 binder, presents great potential as a host of the metastable CaCO 3 for carbon storage and utilization and as an enabler of carbon capture at gigaton scales.

36 MATERIALS SCIENCE↗

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Microstructure and wear properties of Fe-VC-Cr{sub 7}C{sub 3} composite coating on surface of cast steel

An Fe-VC-Cr{sub 7}C{sub 3} composite coating on the surface of cast steel was produced by a novel metal-coated casting technique. The microstructure and wear properties of the product were studied by means of X-ray diffraction, electron beam probe, scanning electron microscopy, and wear testing. The results show that the composite coating consisted of VC and Cr{sub 7}C{sub 3} as the reinforcing phases and {alpha}-Fe as the matrix. The composite coating was metallurgically bonded to the cast steel substrate. The quantity of VC and Cr{sub 7}C{sub 3} carbides decreased gradually from the top surface of the composite coating to the cast steel substrate. The Fe-VC-Cr{sub 7}C{sub 3} composite coating displayed excellent wear-resistance under dry sliding wear test conditions.

36 MATERIALS SCIENCE↗

Material‐Driven Neuronal Oscillators and Filters via Active Reactance in CC‐NDR and VC‐NDR Electro‐Thermal Memristors

The continued scaling of artificial intelligence and telecommunications hardware is increasingly constrained by the power, bandwidth, and area limitations of transistor-based circuits. Neuromorphic processor units, analog oscillators, and active inductors and capacitors rely on complex multi-transistor architectures restricting material choices and incurring energy and footprint overhead. Here, we show that active reactance in electro-thermal memristors provides an intrinsic, material driven route to neuronal oscillator dynamics and signal processing. Using a physics-based compact modeling framework, we bridge negative differential resistance (NDR) and bias-tunable reactance, which underlies spiking dynamics in electro-thermal memristors. Memristors with negative temperature coefficients of resistance (TCR) manifest current-controlled (CC-) NDR and act as active inductors, thus generating spiking above a critical circuit capacitance; whereas memristors with positive TCR manifest voltage-controlled (VC-) NDR and active capacitance, leading to spiking above a critical inductance. By creating a compact model for La 0.7 Ca 0.3 MnO 3 as a representative VC-NDR material and comparing it with LaCoO 3 manifesting CC-NDR, we explain the physical origins of their distinct current-voltage characteristics, reactive phase shifts and consequent spiking behaviors. Finally, we demonstrate tunable filtering enabled by the active reactance of electro-thermal memristors, establishing them as a compact hardware platform for neuronal oscillator functionality and integrated filtering beyond conventional CMOS.

active reactance↗

Synthesis of Mo 4 VAlC 4 MAX Phase and Two-Dimensional Mo 4 VC 4 MXene with Five Atomic Layers of Transition Metals

MXenes are a family of two-dimensional (2D) transition metal carbides, nitrides, and carbonitrides with a general formula of M n+1 X n T x , in which two, three, or four atomic layers of a transition metal (M: Ti, Nb, V, Cr, Mo, Ta, etc.) are interleaved with layers of C and/or N (shown as X), and T x represents surface termination groups such as –OH, =O, and –F. Here, we report the scalable synthesis and characterization of a MXene with five atomic layers of transition metals (Mo 4 VC 4 T x ), by synthesizing its Mo 4 VAlC 4 MAX phase precursor that contains no other MAX phase impurities. These phases display twinning at their central M layers which is not present in any other known MAX phases or MXenes. Transmission electron microscopy and X-ray diffraction were used to examine the structure of both phases. Energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, Raman spectroscopy, and high-resolution scanning transmission electron microscopy with energy-dispersive X-ray spectroscopy were used to study the composition of these materials. Density functional theory calculations indicate that other five transition metal-layer MAX phases (M' 4 M"AlC 4 ) may be possible, where M' and M" are two different transition metals. The predicted existence of additional Al-containing MAX phases suggests that more M 5 C 4 T x MXenes can be synthesized. Additionally, we characterized the optical, electronic, and thermal properties of Mo 4 VC 4 T x . Here, this study demonstrates the existence of an additional subfamily of M 5 X 4 T x MXenes as well as a twinned structure, allowing for a wider range of 2D structures and compositions for more control over properties, which could lead to many different applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predissociation measurements of bond dissociation energies: VC, VN, and VS

The abrupt onset of predissociation in the congested electronic spectra of jet-cooled VC, VN, and VS has been observed using resonant two-photon ionization spectroscopy. It is argued that because of the high density of electronic states in these molecules, the predissociation threshold occurs at the thermochemical threshold for the production of separated atoms in their ground electronic states. As a result, the measured threshold represents the bond dissociation energy. Using this method, bond dissociation energies of D{sub 0}(V C) = 4.1086(25) eV, D{sub 0}(V N) = 4.9968(20) eV, and D{sub 0}(V S) = 4.5353(25) eV are obtained. From these values, enthalpies of formation are derived as Δ{sub f,0K}H°(V C(g)) = 827.0 ± 8 kJ mol{sup −1}, Δ{sub f,0K}H°(V N(g)) = 500.9 ± 8 kJ mol{sup −1}, and Δ{sub f,0K}H°(V S(g)) = 349.3 ± 8 kJ mol{sup −1}. Using a thermochemical cycle and the well-known ionization energies of V, VC, and VN, our results also provide D{sub 0}(V{sup +}–C) = 3.7242(25) eV and D{sub 0}(V{sup +}–N) = 4.6871(20) eV. These values are compared to previous measurements and to computational results. The precision of these bond dissociation energies makes them good candidates for testing computational chemistry methods, particularly those that employ density functional theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Materials Data on VC by Materials Project

VC is Halite, Rock Salt structured and crystallizes in the cubic Fm-3m space group. The structure is three-dimensional. V4+ is bonded to six equivalent C4- atoms to form a mixture of edge and corner-sharing VC6 octahedra. The corner-sharing octahedral tilt angles are 0°. All V–C bond lengths are 2.08 Å. C4- is bonded to six equivalent V4+ atoms to form a mixture of edge and corner-sharing CV6 octahedra. The corner-sharing octahedral tilt angles are 0°.

36 MATERIALS SCIENCE↗

SU-F-P-61: Does It Matter Not to Use Optimization Points at the Apex for Vaginal Cylinder HDR Brachytherapy Planning?

Purpose: To test the impact of the use of apex optimization points for new vaginal cylinder (VC) applicators. Methods: New “ClickFit” single channel VC applicators (Varian) that have a different top thicknesses but the same diameters as the old VC applicators (2.3 cm diameter, 2.6 cm, 3.0 cm, and 3.5 cm) were compared using phantom studies. Old VC applicator plans without apex optimization points were also compared to the plans with the optimization points. The apex doses were monitored at 5 mm depth doses (8 points) where a prescription dose (Rx) of 6Gy was prescribed. VC surface doses (8 points) were also analyzed. Results: The new VC applicator plans without apex optimization points presented significantly lower 5mm depth doses than Rx (on average −31 ± 7%, p <0.00001) due to their thicker VC tops (3.4 ± 1.1 mm thicker with the range of 1.2 to 4.4 mm) than the old VC applicators. Old VC applicator plans also showed a statistically significant reduction (p <0.00001) due to Ir-192 source anisotropic effect at the apex region but the % reduction over Rx was only −7 ± 9%. However, by adding apex optimization points to the new VC applicator plans, the plans improved 5 mm depth doses (−7 ± 9% over Rx) that were not statistically different from old VC plans (p = 0.923), along with apex VC surface doses (−22 ± 10% over old VC versus −46 ± 7% without using apex optimization points). Conclusion: The use of apex optimization points are important in order to avoid significant additional cold doses (−24 ± 2%) at the prescription depth (5 mm) of apex, especially for the new VC applicators that have thicker tops.

60 APPLIED LIFE SCIENCES↗

MRI-Based Evaluation of the Vaginal Cuff in Brachytherapy Planning: Are We Missing the Target?

Purpose: Although recurrences and toxicity occur after vaginal cuff (VC) brachytherapy, little is known about dosimetry due to the inability to clearly visualize the VC on computed tomography (CT). T2-weighted (T2W) magnetic resonance imaging (MRI) is superior to CT in this setting, and we hypothesized that it could provide previously unascertainable dosimetric information. Methods and Materials: In a cohort of 32 patients who underwent cylinder-based brachytherapy for endometrial cancer with available MR simulation images, the VC was retrospectively contoured on T2W images, and cases were replanned to treat the upper VC to a dose of 7 Gy/fraction prescribed to 5 mm. Relevant dose-volume parameters for the VC were calculated. Results: T2W MRI identified significant underdosing not observed on CT or T1-weighted imaging. Over two-thirds (69%) of patients had at least 1 cm{sup 3} of VC that received less than 75% of the prescription dose and half (50%) of patients had a least 1 cm{sup 3} of VC that received less than 50% of the prescription dose. The mean minimum point dose to the VC was 2.4 Gy, or 34% of the intended prescription dose (range: 0.53-6.4 Gy). Conclusions: We identified previously unreported VC underdosing in over two-thirds of our patients, with most of these patients having volumes of undistended VC that received less than half of the prescription dose. The maximum dimension was along the craniocaudal axis in some patients or left-right/anterior-posterior axis in others, suggesting that suture material may be restricting access to the vaginal apex and that alternative applicators may be needed when the diameter of the apex is larger than the introitus. Additional follow-up will be needed to determine whether underdosing is associated with isolated VC failure or whether low failure rates across the cohort suggest that some patients are being exposed to excessive dose and unnecessary risk of toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solid waste management of temple floral offerings by vermicomposting using Eisenia fetida

Highlights: ► Effective management of temple floral offerings using E. fetida. ► Physico-chemical properties in TW VC were better especially EC, C/N, C/P and TK. ► TW VC as plant growth promoter at much lower application rates than KW and FYW VC. - Abstract: Recycling of temple waste (TW) mainly comprising of floral offerings was done through vermitechnology using Eisenia fetida and its impact on seed germination and plant growth parameters was studied by comparing with kitchen waste (KW) and farmyard waste (FYW) vermicompost (VC). The worm biomass was found to be maximum in TW VC compared to KW and FYW VCs at both 40 and 120 days old VCs. Physico-chemical analysis of worm-worked substrates showed better results in TW VC especially in terms of electrical conductivity, C/N, C/P and TK. 10% TW VC–water extract (VCE) showed stimulatory effect on germination percentage of chickpea seeds while KW and FYW VCE proved effective at higher concentration. Variation in growth parameters was also observed with change in the VC–soil ratio and TW VC showed enhanced shoot length, root length, number of secondary roots and total biomass at 12.5% VC compared to KW and FYW VC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Respiratory Vinyl Chloride Reductive Dechlorination to Ethene in TceA-Expressing Dehalococcoides mccartyi

Bioremediation of chlorinated ethenes in anoxic aquifers hinges on organohalide-respiring Dehalococcoidia expressing vinyl chloride (VC) reductive dehalogenase (RDase). The tceA gene encoding the trichloroethene-dechlorinating RDase TceA is frequently detected in contaminated groundwater but not recognized as a biomarker for VC detoxification. We demonstrate that tceA-carrying Dehalococcoides mccartyi (Dhc) strains FL2 and 195 grow with VC as an electron acceptor when sufficient vitamin B 12 (B 12 ) is provided. Strain FL2 cultures that received 50 μg L –1 B 12 completely dechlorinated VC to ethene at rates of 14.80 ± 1.30 μM day –1 and attained 1.64 ± 0.11 × 10 8 cells per μmol of VC consumed. Strain 195 attained similar growth yields of 1.80 ± 1.00 × 10 8 cells per μmol of VC consumed, and both strains could be consecutively transferred with VC as the electron acceptor. Proteomic analysis demonstrated TceA expression in VC-grown strain FL2 cultures. Resequencing of the strain FL2 and strain 195 tceA genes identified non-synonymous substitutions, although their consequences for TceA function are currently unknown. The finding that Dhc strains expressing TceA respire VC can explain ethene formation at chlorinated solvent sites, where quantitative polymerase chain reaction analysis indicates that tceA dominates the RDase gene pool.

54 ENVIRONMENTAL SCIENCES↗

Cometabolic Vinyl Chloride Degradation at Acidic pH Catalyzed by Acidophilic Methanotrophs Isolated from Alpine Peat Bogs

Remediation of toxic chlorinated ethenes via microbial reductive dechlorination can lead to ethene formation; however, the process stalls in acidic groundwater, leading to the accumulation of carcinogenic vinyl chloride (VC). This study explored the feasibility of cometabolic VC degradation by moderately acidophilic methanotrophs. Furthermore, two novel isolates, Methylomonas sp. strain JS1 and Methylocystis sp. strain MJC1, were obtained from distinct alpine peat bogs located in South Korea. Both isolates cometabolized VC with CH 4 as the primary substrate under oxic conditions at pH at or below 5.5. VC cometabolism in axenic cultures occurred in the presence (10 μM) or absence (<0.01 μM) of copper, suggesting that VC removal had little dependence on copper availability, which regulates expression and activity of soluble and particulate methane monooxygenases in methanotrophs. The model neutrophilic methanotroph Methylosinus trichosporium strain OB3b also grew and cometabolized VC at pH 5.0 regardless of copper availability. Bioaugmentation of acidic peat soil slurries with methanotroph isolates demonstrated enhanced VC degradation and VC consumption below the maximum concentration level of 2 μg L –1 . Community profiling of the microcosms suggested species-specific differences, indicating that robust bioaugmentation with methanotroph cultures requires further research.

54 ENVIRONMENTAL SCIENCES↗

Dehalogenation of Chlorinated Ethenes to Ethene by a Novel Isolate, “ Candidatus Dehalogenimonas etheniformans”

Dehalococcoides mccartyi strains harboring vinyl chloride (VC) reductive dehalogenase (RDase) genes are keystone bacteria for VC detoxification in groundwater aquifers, and bioremediation monitoring regimens focus on D. mccartyi biomarkers. We isolated a novel anaerobic bacterium, “Candidatus Dehalogenimonas etheniformans” strain GP, capable of respiratory dechlorination of VC to ethene. This bacterium couples formate and hydrogen (H2) oxidation to the reduction of trichloro-ethene (TCE), all dichloroethene (DCE) isomers, and VC with acetate as the carbon source. Cultures that received formate and H2 consumed the two electron donors concomitantly at similar rates. A 16S rRNA gene-targeted quantitative PCR (qPCR) assay measured growth yields of (1.2 ± 0.2) × 10 8 and (1.9 ± 0.2) × 10 8 cells per μmol of VC dechlorinated in cultures with H 2 or formate as electron donor, respectively. About 1.5-fold higher cell numbers were measured with qPCR targeting cerA, a single-copy gene encoding a putative VC RDase. A VC dechlorination rate of 215 ± 40 μmol L -1 day -1 was measured at 30°C, with about 25% of this activity occurring at 15°C. Increasing NaCl concentrations progressively impacted VC dechlorination rates, and dechlorination ceased at 15 g NaCl L -1 . During growth with TCE, all DCE isomers were intermediates. Tetrachloroethene was not dechlorinated and inhibited dechlorination of other chlorinated ethenes. Carbon monoxide formed and accumulated as a metabolic by-product in dechlorinating cultures and impacted reductive dechlorination activity. Finally, the isolation of a new Dehalogenimonas species able to effectively dechlorinate toxic chlorinated ethenes to benign ethene expands our understanding of the reductive dechlorination process, with implications for bioremediation and environmental monitoring.

59 BASIC BIOLOGICAL SCIENCES↗