Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VAR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mechanism Analysis of Wind Turbine Var Oscillations

Electromagnetic transient simulation of parallel connected 4-MW type-3 wind turbines based on original equipment manufacturer's real-code turbine model shows 1.2-Hz turbine-turbine oscillations in reactive power. This letter reveals why such oscillations occur in the individual var measurement, while being insignificant in the total var measurement, regardless of the varying grid impedance. We adopt two analysis approaches: open-loop single-input single-output analysis and network decomposition. The two approaches differ in their treatment of turbine-network interaction. The open-loop analysis shows that the turbine-turbine oscillation mode is due to an open-loop system pole being attracted to an open-loop system zero. Furthermore, we use network decomposition method to explain why this mode is observable in individual vars while not observable in the total var. The entire system of n -turbines can be viewed as n decoupled circuits. For the two-turbine case, the system has an aggregated mode and a turbine-turbine oscillation mode. Here, the aggregated mode is associated with a circuit associated with the total var, while the turbine-turbine oscillation mode is associated with the var difference and is insensitive to the grid parameters.

17 WIND ENERGY↗

EMS and DMS Integration of the Coordinative Real-time Sub-Transmission Volt-Var Control Tool under High DER Penetration

This paper proposes an applicable approach to deploy the Coordinative Real-time Sub-Transmission Volt-Var Control Tool (CReST-VCT), and a holistic system integration framework considering both the energy management system (EMS) and distribution system management system (DMS). This provides an architectural basis and can serve as the implementation guideline of CReST-VCT and other advanced grid support tools, to co-optimize the operation benefits of DERs and assets in both transmission and distribution networks. Potential communication protocols for different physical domains of a real application is included. Performance and security issues are also discussed, along with specific considerations for field deployment. Finally, the paper presents a viable pathway for CReST-VCT and other advanced grid support tools, which could be integrated in an open-source standardized-based platform that supports distribution utilities.

Nguyen, Quan H.↗

Evaluation of Adaptive Volt-VAR to Mitigate PV Impacts [Slides]

Distributed generation (DG) sources like photovoltaic (PV) systems with advanced inverters are able to perform grid-support functions, like autonomous Volt-VAR that attempts to mitigate voltage issues by injecting or consuming reactive power. However, the Volt-VAR function operates with VAR priority, meaning real power may be curtailed to provide additional reactive power support. Since some locations on the grid may be more prone to higher voltages than others, PV systems installed at those locations may be forced to curtail more power, adversely impacting the value of that PV system. Adaptive Volt-VAR (AVV) could be implemented as an alternative, whereby the Volt-VAR reference voltage changes over time, but this functionality has not been well-explored in the literature. In this work, the potential benefits and grid impacts of AVV were investigated using yearlong quasi-static time-series (QSTS) simulations. After testing a variety of allowable AVV settings, we found that even with aggressive settings AVV resulted in <0.01% real power curtailment and significantly reduced the reactive power support required from the PV inverter compared to conventional Volt-VAR but did not provide much mitigation for extreme voltage conditions. The reactive power support provided by AVV was injected to oppose large deviations in voltage (in either direction), indicating that it could be useful for other applications like reducing voltage flicker or minimizing interactions with other voltage regulating devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyberattack Detection and Mitigation on Central Volt‐VAr Using Circuit Law and Machine Learning

ABSTRACT In a distribution grid, voltage is maintained within a nominal range through a Volt‐VAr function that controls capacitor banks, reactive power of distributed energy resources (DER), and on‐load tap changers (OLTC). Availability of communications helps with the implementation of central Volt‐VAr control; however, it also opens the system to cyberattacks, causing voltage disturbances. Previous work has shown the adverse impacts of false data injection (FDI) on the central Volt‐VAr control; however, very few works have studied methods to detect and mitigate FDI on Volt‐VAr control. This paper addresses gaps in the detection and mitigation of FDI on the measurement packets of a central Volt‐VAr control. This work uses a two‐stage algorithm for cyberattack detection since the accuracy of a single‐stage machine learning (ML)–based detection method decreases while dealing with unseen data. The first stage is based on the verification of measurements against circuit laws, and the second stage utilizes a tree search algorithm and an ML method to detect the falsified data. This paper compares long short‐term memory (LSTM) and bidirectional LSTM (BiLSTM) as the employed ML algorithms. Finally, the mitigation algorithm replaces the falsified data with the estimated output of the ML algorithm. The effectiveness of the proposed method is tested for several cases using the IEEE 13‐bus test system in PSCAD software.

Beikbabaei, Milad [Bradley Department of Electrica↗

Assimilation of Atmospheric InfraRed Sounder (AIRS) Profiles using WRF-Var

The Weather Research and Forecasting (WRF) model contains a three-dimensional variational (3DVAR) assimilation system (WRF-Var), which allows a user to join data from multiple sources into one coherent analysis. WRF-Var combines observations with a background field traditionally generated using a previous model forecast through minimization of a cost function. In data sparse regions, remotely-sensed observations may be able to improve analyses and produce improved forecasts. One such source comes from the Atmospheric Infrared Sounder (AIRS), which together with the Advanced Microwave Sounding Unit (AMSU), represents one of the most advanced space-based atmospheric sounding systems. The combined AIRS/AMSU system provides radiance measurements used as input to a sophisticated retrieval scheme which has been shown to produce temperature profiles with an accuracy of 1 K over 1 km layers and humidity profiles with accuracy of 15% in 2 km layers in both clear and partly cloudy conditions. The retrieval algorithm also provides estimates of the accuracy of the retrieved values at each pressure level, allowing the user to select profiles based on the required error tolerances of the application. The purpose of this paper is to describe a procedure to optimally assimilate high-resolution AIRS profile data into a regional configuration of the Advanced Research WRF (ARW) version 2.2 using WRF-Var. The paper focuses on development of background error covariances for the regional domain and background field type using gen_be and an optimal methodology for ingesting AIRS temperature and moisture profiles as separate overland and overwater retrievals with different error characteristics in the WRF-Var. The AIRS thermodynamic profiles are obtained from the version 5.0 Earth Observing System (EOS) science team retrieval algorithm and contain information about the quality of each temperature layer. The quality indicators are used to select the highest quality temperature and moisture data for each profile location and pressure level. Analyses are run to produce quasi-real-time regional weather forecasts over the continental U.S. The preliminary assessment of the impact of the AIRS profiles will focus on intelligent use of the quality indicators, optimized tuning of the WRF-Var, and comparison of analysis soundings to radiosondes.

Zavodsky, Brad↗

4D-Var Developement at GMAO

The Global Modeling and Assimilation Offce (GMAO) is currently using an IAU-based 3D-Var data assimilation system. GMAO has been experimenting with a 3D-Var-hybrid version of its data assimilation system (DAS) for over a year now, which will soon become operational and it will rapidly progress toward a 4D-EnVar. Concurrently, the machinery to exercise traditional 4DVar is in place and it is desirable to have a comparison of the traditional 4D approach with the other available options, and evaluate their performance in the Goddard Earth Observing System (GEOS) DAS. This work will also explore the possibility for constructing a reduced order model (ROM) to make traditional 4D-Var computationally attractive for increasing model resolutions. Part of the research on ROM will be to search for a suitably acceptable space to carry on the corresponding reduction. This poster illustrates how the IAU-based 4D-Var assimilation compares with our currently used IAU-based 3D-Var.

GMAO↗

Mechanical characterization of 304L-VAR stainless steel in tension with a full coverage of low, intermediate, and high strain rates

A 304L-VAR stainless steel is mechanically characterized in tension over a full range of strain rates from low, intermediate, to high using a variety of apparatuses. While low- and high-strain-rate tests are conducted with a conventional Instron and a Kolsky tension bar, the tensile tests at intermediate strain rates are conducted with a fast MTS and a Drop-Hopkinson bar. The fast MTS used in this study is able to obtain reliable tensile response at the strain rates up to 150 s -1 , whereas the lower limit for the Drop-Hopkinson bar is 100 s -1 . Combining the fast MTS and the Drop-Hopkinson bar closes the gap within the intermediate strain rate regime. Using these four apparatuses, the tensile stress-strain curves of the 304L-VAR stainless steel are obtained at strain rates on each order of magnitude ranging from 0.0001 to 2580 s -1 . All tensile stress-strain curves exhibit linear elasticity followed by significant work hardening prior to necking. After necking occurrs, the specimen load decreases, and the deformation becomes highly localized until fracture. The tensile stress-strain response of the 304L-VAR stainless steel exhibits strain rate dependence. The flow stress increases with increasing strain rate and is described with a power law. The strain-rate sensitivity is also strain-dependent, possibly due to thermosoftening caused by adiabatic heating at high strain rates. The 304L-VAR stainless steel shows significant ductility. The true strains at the onset of necking and at failure are determined. The results show that the true strains at both onset of necking and failure decrease with increasing strain rate. The true failure strains are approximately 200% at low strain rates but are significantly lower (~100%) at high strain rates. The transition of true failure strain occurs within the intermediate strain rate range between 10 -2 and 10 2 s -1 . A Boltzmann description is used to present the effect of nominal strain rate on true failure strain.

304L-VAR stainless Steel↗

Assessing the Usefulness of AIRS Radiance Observations in a 4D-Var Assimilation Scheme Using the Penn State/NCAR Mesoscale Model Version 5 (MM5) and a Stand Alone Radiative Transfer Algorithm (SARTA)

Short-term precipitation forecast skill remains poor despite further advances in numerical modeling and data analysis. Utilizing indirect observations, such as the radiance observations obtained from the Atmospheric Infrared Sounder (AIRS), in a 4D-Var assimilation scheme may lead to a rapid improvement in the skill of 12-h QPF. In order to investigate the usefulness of AIRS observations, the adjoint code of a radiative transfer model (SARTA) is developed and linked to MM5 4D-Var system. A statistical comparison of the AIRS radiances with those calculated using the linked MMS-SARTA model is carried out to assess errors in the radiative transfer model, MM5 and AIRS data, and to develop a quality control scheme. Outliers and any bias that may exist in radiative transfer model, MM5 and AIRS data are identified. An adjoint sensitivity study, utilizing the SARTA adjoint model, is then done to identify the relative sensitivities of each spectral channel to such parameters as atmospheric temperature, pressure, and mixing ratio. Another sensitivity study is done using the MM5 alone to determine the sensitivity of the 12-h QPF to model parameters such as atmospheric temperature, pressure, and mixing ratio under various weather regimes (i.e. summertime convection, winter snowfall). Results from these two types of adjoint sensitivity studies are used to determine which AIRS channels contribute most to 12-h QPF under differing weather regimes. This information is useful when conducting 4D-Var experiments using a subset of the 2378 AIRS spectral channels. Finally, 4D-Var experiments are done to analyze the impact of the AIRS observations on the quality of the 12-h QPF results. This project falls under the data assimilation general session topic as specified by the conference organizers.

Carrier, M.↗

Transmission-distribution long-term volt-var planning considering reactive power support capability of distributed PV

High penetration of grid-edge, inverter-based photovoltaic (PV) can cause significant voltage fluctuations not only at the distribution but also at the sub-transmission levels due to PV output intermittency. Traditional reactive power planning approaches do not consider intermittency, nor the possibility of coordinating the control of existing and future volt-ampere reactive resources. This paper proposes a reactive power planning tool for sub-transmission systems to mitigate voltage violations and fluctuations caused by high PV penetration and intermittency with a minimum investment cost. The planning tool coordinates with an optimization-based volt-var operational tool for: a) modeling the coordination of all existing var assets in both sub-transmission and distribution systems to reduce the need of new equipment, and b)selecting a set of scenarios with voltage violations, derived from PV intermittency c) testing the final investment decision. The tool obtains an investment need for each intermittency scenario with a proposed optimal power-flow framework with efficient techniques to handle a high number of discrete variables. Two options are provided for final planning decision: i) a conservative direct combination of investment need solutions and ii) a machine learning-based selection of representative investment needs at most time steps. The final investment decision options are verified using a realistic large-scale sub-transmission system and 5-minute PV and load data. The results show a significant voltage performance improvement with a lower investment cost for additional var equipment compared to conventional approaches.

14 SOLAR ENERGY↗

Genomic and transcriptomic characterization of carbohydrate-active enzymes in the anaerobic fungus Neocallimastix cameroonii var. constans

Anaerobic gut fungi effectively degrade lignocellulose in the guts of large herbivores, but there remain a limited number of isolated, publicly available, and sequenced strains that impede our understanding of the role of anaerobic fungi within microbial communities. We isolated and characterized a new fungal isolate, Neocallimastix cameroonii var. constans, providing a transcriptomic and genomic understanding of its ability to degrade diverse carbohydrates. This anaerobic fungal strain was stably cultivated for multiple years in vitro among members of an initial enrichment microbial community derived from goat feces, and it demonstrated the ability to pair with other microbial members, namely, archaeal methanogens to produce methane from lignocellulose. Genomic analysis revealed a higher number of predicted carbohydrate-active enzymes encoded in the N. cameroonii var. constans genome compared to most other sequenced anaerobic fungi. The carbohydrate-active enzyme profile for this isolate contained 660 glycoside hydrolases, 160 carbohydrate esterases, 194 glycosyltransferases, and 85 polysaccharide lyases. Differential gene expression analysis showed the upregulation of thousands of genes (including predicted carbohydrate-active enzymes) when N. cameroonii var. constans was grown on lignocellulose (reed canary grass) compared to less complex substrates, such as cellulose (filter paper), cellobiose, and glucose. AlphaFold was used to predict functions of transcriptionally active yet poorly annotated genes, revealing feruloyl esterases that likely play an important role in lignocellulose degradation by anaerobic fungi. The combination of this strain's genomic and transcriptomic characterization, omics-informed structural prediction, and robustness in microbial co-culture make it a well-suited platform to conduct future investigations into bioprocessing and enzyme discovery.

CAZymes↗

Volt-VAR Optimization in Distribution Networks Using Twin Delayed Deep Reinforcement Learning

Modern distribution grids are undergoing new challenges due to the stochastic nature of distributed energy resources (DERs). High penetration of DERs has a significant impact on Volt-VAR profile and system power losses. This work proposes a deep reinforcement learning (DRL)-based Volt-VAR optimization approach for improving voltage profile and reducing system power loss under high penetration of distributed energy resources, such as battery energy storage and solar photovoltaic units in distribution grids. The twin delayed deep deterministic policy gradient (TD3) method-based DRL agent is proposed to configure optimal set-points of reactive power outputs of fast responding smart inverters. The agent schedules the reactive power of inverters according to their physical capabilities, such as minimum allowed power factor, e.g., 0.9 leading/lagging. The reward function of the proposed DRL scheme is designed carefully to ensure a proper voltage profile of the grids with effective scheduling of reactive power outputs from inverters. The performance of the proposed model is verified on modified IEEE 34- and 123-bus systems and compared with base case with no reactive supply by inverters, and local droop Volt-VAR control approach. The results show that the proposed method performs better than the local droop control and deep deterministic policy gradient (DDPG)-based DRL method for reducing voltage fluctuation and minimizing power loss.

Hossain, Rakib↗

Analysis of 0.1-Hz Var Oscillations in Solar Photovoltaic Power Plants

Oscillations with very low frequency at 0.1 Hz, have been observed in voltage and var in practical solar photovoltaic (PV) systems when power exporting ramps up to a certain level. Here, this letter provides an explanation on the formation of 0.1-Hz oscillations and identifies three critical factors that lead to the oscillations: communication delay between the plant-level control and the inverter-level control, high volt/var sensitivity at a high power exporting level, and the volt-var feedback system consisting of the plant control, inverter control and the grid impact. Furthermore, a critical feature of the 0.1-Hz oscillation is also explained: why oscillations appear only in voltage and var, but not in real power.

14 SOLAR ENERGY↗

Analysis of Conservation Voltage Reduction under Inverter-Based VAR-Support [Slides]

Conservation voltage reduction (CVR) is a common technique used by utilities to strategically reduce demand during peak periods. As penetration levels of distributed generation (DG) continue to rise and advanced inverter capabilities become more common, it is unclear how the effectiveness of CVR will be impacted and how CVR interacts with advanced inverter functions. In this work, we investigated the mutual impacts of CVR and DG from photovoltaic (PV) systems (with and without autonomous Volt-VAR enabled). The analysis was conducted on an actual utility dataset, including a feeder model, measurement data from smart meters and intelligent reclosers, and metadata for more than 30 CVR events triggered by the utility over the year. The installed capacity of the modeled PV systems represented 66% of peak load, but reached instantaneous penetrations reached up to 2.5x the load consumption over the year. While the objectives of CVR and autonomous Volt-VAR are opposed to one another, this study found that their interactions were mostly inconsequential since the CVR events occurred when total PV output was low.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Tied PV Inverter with Oversized Power Module to Increase its Low-Voltage Ride Through (LVRT) Capabilities and VAR Support

This paper proposes a novel design for grid-tied 3-ph Photovoltaic (PV) inverter to improve its low-voltage ride through (LVRT) response while significantly increasing its voltampere reactive (VAR) support during voltage sags. The literature available on LVRT for PV inverters can be grouped in solutions that dissipate the excess energy and those that temporary stores this energy. This paper proposes a third solution; oversizing inverter hardware components to safely transferring all the energy excess back to while maintaining the semiconductor under the maximum temperature limits. The advantages of the proposed approach are: 1) Improved LVRT capabilities and stable dc-link voltage control at MPP during sags. 2) Increased VAR support during voltage sags. 3) Increased use of renewable energy as all active power is injected back to the grid during voltage sags. Finally, the proposed solution is more cost effective compared with solutions that incorporate energy storage because only a few inverter components are required to be oversized. This paper also presents a detailed power loss analysis, which determined that that oversizing the power semiconductors has minimal impact in the inverter losses while significatively reducing the diode and IGBT conduction losses during both normal operation and grid fault conditions.

Ferrari Maglia, Max↗

Reinforcement Learning for Volt- Var Control: A Novel Two-stage Progressive Training Strategy

This paper develops a reinforcement learning (RL) approach to solve a cooperative, multi-agent Volt-Var Control (VVC) problem for high solar penetration distribution systems. The ingenuity of our RL method lies in a novel two-stage progressive training strategy that can effectively improve training speed and convergence of the machine learning algorithm. In Stage 1 (individual training), while holding all the other agents inactive, we separately train each agent to obtain its own optimal VVC actions in the action space: fconsume, generate, do-nothingg. In Stage 2 (cooperative training), all agents are trained again coordinatively to share VVC responsibility. Rewards and costs in our RL scheme include (i) a system-level reward (for taking an action), (ii) an agent-level reward (for doing-nothing), and (iii) an agent-level action cost function. This new framework allows rewards to be dynamically allocated to each agent based on their contribution while accounting for the trade-off between control effectiveness and action cost. The proposed methodology is tested and validated in a modified IEEE 123-bus system using realistic PV and load profiles. Simulation results confirm that the proposed approach is robust and computationally efficient; and it achieves desirable volt-var control performance under a wide range of operation conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Attention Enabled Multi-Agent DRL for Decentralized Volt-VAR Control of Active Distribution System Using PV Inverters and SVCs

This paper proposes attention enabled multi-agent deep reinforcement learning (MADRL) framework for active distribution network decentralized Volt-VAR control. Using the unsupervised clustering, the whole distribution system can be decomposed into several sub-networks according to the voltage and reactive power sensitivity relationships. Then, the distributed control problem of each sub-network is modeled as Markov games and solved by the improved MADRL algorithm, where each sub-network is modeled as an adaptive agent. An attention mechanism is developed to help each agent focus on specific information that is mostly related to the reward. All agents are centrally trained offline to learn the optimal coordinated Volt-VAR control strategy and executed in a decentralized manner to make online decisions with only local information. Compared with other distributed control approaches, the proposed method can effectively deal with uncertainties, achieve fast decision makings, and significantly reduce the communication requirements. Comparison results with model-based and other data-driven methods on IEEE 33-bus and 123-bus systems demonstrate the benefits of the proposed approach.

distribution network↗

VARS Framework

The Verification and Validation Assuring Reliability and Security (VARS) project team has developed the proof-of-concept VARS framework which will be implemented in the form of a software tool called Risk-Informed Verification and Validation Recommendation (RIVVR). The framework will provide Energy Delivery System (EDS) stakeholders with cybersecurity focused verification and validation (V&V) approach which includes list of potentially relevant vulnerabilities to test or address, pre-procurement guidance, and separate lists of relevant standards, tools, and techniques (ST2) to be considered by utilities and vendors

Pal, Seemita↗