Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utility and Grid Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Coolidge solar powered irrigation pumping project

A 150 kW solar thermal electric power plant which includes over 2100 square meters of parabolic trough type collectors and an organic Rankine cycle turbine engine was constructed on an irrigated farm. The plant is interconnected with the electrical utility grid. Operation is providing an evaluation of equipment performance and operating and maintenance requirements as well as the desirability of an on farm location.

Larson, D. L.↗

Reliability and quality assurance on the MOD 2 wind system

The Safety, Reliability, and Quality Assurance (R&QA) approach developed for the largest wind turbine generator, the Mod 2, is described. The R&QA approach assures that the machine is not hazardous to the public or to the operating personnel, is operated unattended on a utility grid, demonstrates reliable operation, and helps establish the quality assurance and maintainability requirements for future wind turbine projects. The significant guideline consisted of a failure modes and effects analysis (FMEA) during the design phase, hardware inspections during parts fabrication, and three simple documents to control activities during machine construction and operation.

Mason, W. E. B.↗

Experience with modified aerospace reliability and quality assurance method for wind turbines

The SR&QA approach assures that the machine is not hazardous to the public or operating personnel, can operate unattended on a utility grid, demonstrates reliability operation, and helps establish the quality assurance and maintainability requirements for future wind turbine projects. The approach consisted of modified failure modes and effects analysis (FMEA) during the design phase, minimal hardware inspection during parts fabrication, and three simple documents to control activities during machine construction and operation. Five years experience shows that this low cost approach works well enough that it should be considered by others for similar projects.

Klein, W. E.↗

Modified aerospace reliability and quality assurance method for wind turbines

The safety, reliability, and quality assurance (SR&QA) approach developed for the first large wind turbine generator project is described. The SR&QA approach was used to assure that the machine would not be hazardous to the public or operating personnel, would operate unattended on a utility grid, would demonstrate reliable operation and would help establish the quality assurance and maintainability requirements for future wind turbine projects. A modified failure modes and effects analysis during the design phase, minimal hardware inspections during parts fabrication, and three simple documents to control activities during machine construction and operation were presented.

Klein, W. E.↗

Modified aerospace R&QA method for wind turbines

This paper describes the Safety, Reliability and Quality Assurance (SR&QA) approach developed for the first large wind turbine generator project, MOD-OA. The SR&QA approach to be used had to assure that the machine would not be hazardous, would operate unattended on a utility grid, would demonstrate reliable operation, and would help establish the quality assurance and maintainability requirements for wind turbine projects. The final approach consisted of a modified Failure Modes and Effects Analysis (FMEA) during the design phase, minimal hardware inspections during parts fabrication, and three documents to control activities during machine construction and operation.

Klein, W. E.↗

Installation and checkout of the DOE/NASA Mod-1 2000-kW wind turbine generator

The paper describes the DOE/NASA Mod-1 wind turbine generator, its assembly and testing, and its installation at Boone, North Carolina. The paper concludes with performance data taken during the initial tests conducted on the machine. The successful installation and initial operation of the Mod-1 wind turbine generator has had the following results: (1) megawatt-size wind turbines can be operated satisfactorily on utility grids; (2) the structural loads can be predicted by existing codes; (3) assembly of the machine on top of the tower presents no major problem; (4) large blades 100 ft long can be transported long distances and over mountain roads; and (5) operating experience and performance data will contribute substantially to the design of future low-cost wind turbines.

Puthoff, R. L.↗

Enabling Universal Access to Power on the Lunar Surface

The National Aeronautics and Space Administration (NASA) Artemis Missions will return human astronauts to the lunar surface, demonstrate technologies that establish a sustained presence on the lunar surface and enable human missions to Mars, and help create a lunar commercial economy. Creating a sustained permanent presence on the lunar surface will require access to continuous and highly reliable power to support mission needs. During Artemis, lunar surface operations will evolve and grow over time (years), requiring an increase in the amount of power needed (100s of kW) and distance that the power must be transmitted (up to 10 km during early Artemis missions). A lunar commercial economy is likely to exceed this power demand to the MW level and distance in the 100s of km. This increased distance and demand for highly reliable power drives the need to create an electric power grid by connecting localized lunar power systems (e.g., habitats, in-situ resource utilization plants, etc.), each containing one or more loads and/or sources. Developing a lunar surface power grid will allow lunar surface operations to resemble electrical utility operations on Earth; it allows power to be generated where it is convenient and allows power to be consumed where it is convenient and required. A lunar surface electric power grid will facilitate the growth of a lunar commercial economy because it provides a means to connect new loads to an existing electrical power system. A common standardized interface to the grid and a set of standardized voltages is required to take full advantage of the benefits of an electric power grid, similar to the terrestrial power grid. NASA Glenn Research Center is leading an effort to create universal access to power through the development of the Universal Modular Interface Converter (UMIC). The UMIC is designed to have a common interface that connects sources and loads compliant with the International Space Power System Interoperability Standard (ISPSIS) to a higher voltage AC transmission system or power grid. This presentation will further discuss the evolution of power during the Artemis missions, challenges associated with creating a sustained presence on the lunar surface, progress made on the UMIC, and future opportunities for technology development and standards.

space power systems↗

Drive Train Normal Modes Analysis for the ERDA/NASA 100-Kilowatt Wind Turbine Generator

Natural frequencies, as a function of power were determined using a finite element model. Operating conditions investigated were operation with a resistive electrical load and operation synchronized to an electrical utility grid. The influence of certain drive train components on frequencies and mode shapes is shown. An approximate method for obtaining drive train natural frequencies is presented.

Sullivan, T. L.↗

Diagnosing coupled jet-streak circulations for a northern plains snow band from the operational nested-grid model

On 17 March 1989, moderate to heavy snow developed in a 100- to 200-km-wide band extending from South Dakota to northern Michigan. The 4- to 8-inch snowfall within this band was not associated with major cyclogenesis, and developed 500 to 600 km north of a stationary surface front. A diagnostic analysis based on an application of the General Meteorological Package (GEMPAK 5.0) to a numerical simulation from the operational nested-grid model (NGM) is utilized to show that the development of this snow band is related to the interaction of two upper-tropospheric jet streaks and their associated transverse circulation patterns. The eastward propagation of a jet streak from the West Coast toward the middle United States and to the south of a slower-moving jet along the U.S.-Canadian border led to a merger of the ascent maxima associated with the direct and indirect circulations of the northern and southern jets, respectively. The snow band developed as the ascending branches of the jet-streak circulation patterns merged, with the eastward propagation of the heaviest snow linked to the motion of the coupled circulation pattern. The study also demonstrates the usefulness of the operational NGM for providing the higher-resolution datasets required to relate the evolution of jet-streak circulation patterns to the development of mesoscale precipitation bands.

Hakim, Gregory J.↗

Development of a Multi-bus, Multi-source Reconfigurable Stirling Radioisotope Power System Test Bed

The National Aeronautics and Space Administration (NASA) has typically used Radioisotope Thermoelectric Generators (RTG) as their source of electric power for deep space missions. A more efficient and potentially more cost effective alternative to the RTG, the high efficiency 110 watt Stirling Radioisotope Generator 110 (SRG110) is being developed by the Department of Energy (DOE), Lockheed Martin (LM), Stirling Technology Company (STC) and NASA Glenn Research Center (GRC). The SRG110 consists of two Stirling convertors (Stirling Engine and Linear Alternator) in a dual-opposed configuration, and two General Purpose Heat Source (GPHS) modules. Although Stirling convertors have been successfully operated as a power source for the utility grid and as a stand-alone portable generator, demonstration of the technology required to interconnect two Stirling convertors for a spacecraft power system has not been attempted. NASA GRC is developing a Power System Test Bed (PSTB) to evaluate the performance of a Stirling convertor in an integrated electrical power system application. This paper will describe the status of the PSTB and on-going activities pertaining to the PSTB in the NASA Thermal-Energy Conversion Branch of the Power and On-Board Propulsion Technology Division.

Coleman, Anthony S.↗

Micro-grid for Future Planetary Surface Needs

Under the current Artemis Program, the National Aeronautics and Space Administration (NASA) will send its next set of astronauts (first woman and next man) to the Moon by 2024 and establish a sustainable presence on the lunar surface by 2028. The challenge of creating a sustained lunar surface presence is significantly different than previous efforts. Lunar surface operations will require access to continuous and highly reliable power to support mission needs, such as to support ISRU operations. Adding to this challenge, the lunar surface operations are not going to be established over a single effort, rather the system and operations will evolve and grow over time (years). The first initial loads that arrive on the lunar surface will be integrated to their own dedicated power sources. As the lunar surface operations grow, so will the demand for power and at some point these individual loads will require more power than can be generated with any single power device. This power demand drives the need for inter-connecting the loads and power devices to share power between them, resulting in a micro-grid. One of the advantages of developing a lunar surface micro-grid is that allows lunar surface operations to resemble electrical utility operations on Earth; it allows power to be generated where it is convenient and allows power to be consumed where it is convenient, rather than negotiating between generation and consumption. The micro-grid concept also provides another benefit of affording the ability to increase overall system reliability by integrating dissimilar power generation and energy storage devices together, for example modifying the power generation strategy to include both solar arrays and nuclear. Creating a lunar surface micro-grid has its advantages, however there are significant challenges associated with an evolvable micro-grid concept. The challenges include how to efficiently transmit large amounts of power (10kW+) long distances (1kW+), how to effectively integrate dissimilar power generation and energy storage devices to maximize power consumption and minimize downtime, and how to physically connect these devices together with a connector that can survive the lunar environment (dust, extreme cold temperatures) and is capable of both astronaut and robotic operation. The basic components of the micro-grid have to be designed to ensure the system is sustainable, modular, and reconfigurable. An interface to the micro-grid has to be designed that allows for additional technologies, some of which may not yet be fully designed, to easily integrate into the micro-grid concept. This presentation discusses these lunar challenges in some more depth and offers a path forward in designing an evolvable micro-grid to meet the needs of the lunar surface operations and proposes a Universal Micro-grid Interface Converter to connect these dissimilar power sources and mission loads to the micro-grid.

Jeffrey Csank↗

Auxiliary propulsion thruster performance with ion machined accelerator grids

A substantial improvement in the performance of an 8-centimeter-diameter auxiliary propulsion thruster was achieved by reducing the diameter of the accelerator grid apertures. The accelerator grid hole geometry was defined by ion machining accelerator grids on an 8-centimeter thruster at thrust levels of 2.2, 4.4, and 6.7 millinewtons was (mN). A thruster with an ion machined accelerator grid was operated at a thrust of 4.4 mN for 1000 hours. The discharge propellant utilization was 92% at an eV/ion of 338. Thruster performance and accelerator grid hole geometry was documented as a function of thrust level. It was also determined that the small hole accelerator grid has a very low backstreaming voltage limit. In fact the thruster can be operated with the acclerator grid held at neutralizer tip potential.

Hudson, W. R.↗

Auxiliary propulsion thruster performance with ion machined accelerator grids

A substantial improvement in the performance of an 8-centimeter-diameter auxiliary propulsion thruster has been achieved by reducing the diameter of the accelerator grid apertures. The accelerator grid hole geometry has been defined by ion machining accelerator grids on an 8-centimeter thruster at thrust levels of 2.2, 4.4, and 6.7 millinewtons (mN). A thruster with an ion machined accelerator grid has been operated at a thrust of 4.4 mN for 1000 hours. The discharge propellant utilization was 92% at an eV/ion of 338. Thruster performance and accelerator grid hole geometry has been documented as a function of thrust level. It was also determined that the small hole accelerator grid has a very low backstreaming voltage limit. In fact the thruster can be operated with the accelerator grid held at neutralizer tip potential.

Hudson, W. R.↗

Microgrid for Lunar Surface Power

Sustained lunar surface operations will require access to continuous and highly reliable power to support mission needs and an ability to evolve and grow over time (years). The first initial loads that arrive on the lunar surface will contain their own dedicated power sources. Over time, as the lunar surface operations and power demands grow, these individual power loads will require more power than can be generated with any single power device. This demand drives the need for inter-connecting loads and power devices to share power between them, resulting in a micro-grid. One advantage of developing a lunar surface micro-grid is that it will allow lunar surface operations to resemble electrical utility operations on Earth; it allows power to be generated where it is convenient and allows power to be consumed where it is convenient and required. The micro-grid concept also provides another benefit of affording the ability to increase overall system reliability by integrating dissimilar power generation and energy storage devices together, for example modifying the power generation strategy to include both solar arrays and nuclear. This talk provides an overview of NASA’s interest in developing a lunar microgrid and provides areas where external entities can play a role in developing futuristic power needs.

Jeffrey Csank↗

DOE LeRC photovoltaic systems test facility

The facility was designed and built and is being operated as a national facility to serve the needs of the entire DOE National Photovoltaic Program. The object of the facility is to provide a place where photovoltaic systems may be assembled and electrically configured, without specific physical configuration, for operation and testing to evaluate their performance and characteristics. The facility as a breadboard system allows investigation of operational characteristics and checkout of components, subsystems and systems before they are mounted in field experiments or demonstrations. The facility as currently configured consist of 10 kW of solar arrays built from modules, two inverter test stations, a battery storage system, interface with local load and the utility grid, and instrumentation and control necessary to make a flexible operating facility. Expansion to 30 kW is planned for 1978. Test results and operating experience are summaried to show the variety of work that can be done with this facility.

Cull, R. C.↗

Dispersed solar thermal generation employing parabolic dish-electric transport with field modulated generator systems

This paper discusses the application of field modulated generator systems (FMGS) to dispersed solar-thermal-electric generation from a parabolic dish field with electric transport. Each solar generation unit is rated at 15 kWe and the power generated by an array of such units is electrically collected for insertion into an existing utility grid. Such an approach appears to be most suitable when the heat engine rotational speeds are high (greater than 6000 r/min) and, in particular, if they are operated in the variable speed mode and if utility-grade a.c. is required for direct insertion into the grid without an intermediate electric energy storage and reconversion system. Predictions of overall efficiencies based on conservative efficiency figures for the FMGS are in the range of 25 per cent and should be encouraging to those involved in the development of cost-effective dispersed solar thermal power systems.

Ramakumar, R.↗

Comparison of Numerically Simulated and Experimentally Measured Performance of a Rotating Detonation Engine

A quasi-two-dimensional, computational fluid dynamic (CFD) simulation of a rotating detonation engine (RDE) is described. The simulation operates in the detonation frame of reference and utilizes a relatively coarse grid such that only the essential primary flow field structure is captured. This construction and other simplifications yield rapidly converging, steady solutions. Viscous effects, and heat transfer effects are modeled using source terms. The effects of potential inlet flow reversals are modeled using boundary conditions. Results from the simulation are compared to measured data from an experimental RDE rig with a converging-diverging nozzle added. The comparison is favorable for the two operating points examined. The utility of the code as a performance optimization tool and a diagnostic tool are discussed.

combustion↗

Multi-dimensional analysis of combustion instabilities in liquid rocket motors

A three-dimensional analysis of combustion instabilities in liquid rocket engines is presented based on a mixed finite difference/spectral solution methodology for the gas phase and a discrete droplet tracking formulation for the liquid phase. Vaporization is treated by a simplified model based on an infinite thermal conductivitiy assumption for spherical liquid droplets of fuel in a convective environment undergoing transient heating. A simple two parameter phenomenological combustion response model is employed for validation of the results in the small amplitude regime. The computational procedure is demonstrated to capture the phenomena of wave propagation within the combustion chamber accurately. Results demonstrate excellent amplitude and phase agreement with analytical solutions for properly selected grid resolutions under both stable and unstable operating conditions. Computations utilizing the simplified droplet model demonstrate stable response to arbitrary pulsing. This is possibly due to the assumption of uniform droplet temperature which removes the thermal inertia time-lag response of the vaporization process. The mixed-character scheme is sufficiently efficient to allow solutions on workstations at a modest increase in computational time over that required for two-dimensional solutions.

Grenda, Jeffrey M.↗