Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Urban warming”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The High-resolution Urban Meteorology for Impacts Dataset (HUMID) daily for the Conterminous United States

Many current gridded surface meteorological datasets are inadequate for quantifying near surface spatiotemporal variability because they do not fully represent the impacts of land surface heterogeneity. Of note, explicit representation of the spatial structure and magnitude of local urban warming are usually lacking. Here we enhance the representation of spatial meteorological variability over urban areas in the conterminous United States (CONUS) by employing the High-Resolution Land Data Assimilation System (HRLDAS), which accounts for the fine-scale impacts of spatiotemporally varying land surfaces on weather. We also synthesize in situ meteorological data including local mesonets to create a 1 km grid spacing model-observation fusion product spanning 1981-2018 over the CONUS. Daily maximum, minimum, and mean values for a variety of temperature estimates, humidity, and surface energy budget terms, among others, are included. This High-resolution Urban Meteorology for Impacts Dataset (HUMID) will be useful for studies examining spatial variability of near surface meteorology and the impacts of urban heat islands across many disciplines including epidemiology, ecology, and climatology.

54 ENVIRONMENTAL SCIENCES

Urban heat islands can influence the wind energy resource during heatwaves

Urban wind energy is critical for sustainable electricity generation in cities. However, little research has explored how the urban heat island (UHI) effect influences wind energy, particularly in heatwaves when energy demand surges. In this study, we examine wind energy distribution in the Boston–Providence metropolitan area during heatwaves, using Weather Research and Forecasting (WRF) model integrated with Building Energy Parameterization/Building Energy Model (BEP/BEM). Two scenarios, a realistic case and a hypothetical case without urban warmth, were compared to isolate UHI impacts. Results reveal that UHI induces a "wind energy loss zone" in this urban area, reducing wind power density (WPD) by 20–30 W/m 2 at 50–100 m, while suburban/rural areas exhibit a "wind energy gain zone," with WPD increases up to 40 W/m 2 at 150–200 m. These losses diminish with distance from urban centers and become negligible beyond main urban and suburban sprawl. Heatwave expands the urban "loss zone", while amplifying wind energy gains in suburban/rural areas, driven by stronger thermal gradients and weakened background winds that intensify air convergence in urban and urban-rural circulations, thereby exacerbating urban wind energy losses by 15–20 %. An analysis of 235 wind farms using turbine power curves reveals that built areas dependent on stand-alone or off-grid turbines face significant energy deficits during a heatwave. Wind energy drops by up to 25 %, while cooling-related building energy demand rises 30–40 % during a heatwave. These findings underscore the need for strategic urban wind energy planning to ensure reliable power during extreme heat.

Energy - Wind

Will cities keep getting hotter? The interplay of urban expansion and greening reshapes future urban heat trajectories

Urban heat islands (UHIs) pose growing risks to public health, infrastructure, and resilience. While often assumed to intensify with urban growth, dynamic changes in urban expansion and vegetation greenness complicate UHI trajectories, which remain poorly understood. This study investigated the interplay of urban expansion and greenness change on UHI spatial profile across 36 Chinese megacities during 2003–2018 using multiple satellite products. We introduce a framework that classifies urban areas into four dynamic development pathways based on impervious surface area (ISA) and enhanced vegetation index (EVI) trends: urbanized-greening, urbanized-browning, urbanizing-greening (UingG), and urbanizing-browning (UingB). While most urbanized centers exhibited greening driven by targeted initiatives and urbanizing suburbs showed browning due to vegetation loss, about 30% urban areas showed the reverse pattern, revealing overlooked complexity in urban development. Urban expansion and browning strengthened UHI in suburban areas, whereas greening initiatives mitigated UHI in urban center and mitigated UHI enhancement in suburban areas. Slowed warming in urban centers together with accelerated warming in suburban areas flattened the temperature gradient between urban centers and suburbs. This dynamic expanded the spatial extent of elevated temperatures and reshaped the classic urban-to-rural UHI profile into a flatter form. In UingB areas, UHI intensification was jointly driven by increase in ISA, vegetation loss, and their interaction, while in UingG areas, EVI increases and a negative interaction together offset over half of the warming driven by urban expansion. These findings reveal that UHI evolution is not unidirectional but depends on localized urbanization and greening dynamics, offering pathways for strategic heat mitigation.

greening initiative

WRF-Comfort: simulating microscale variability in outdoor heat stress at the city scale with a mesoscale model

Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.

Geology

Trees halve urban heat island effect globally but unequal benefits only modestly mitigate climate-change warming

Although tree cover reduces the urban heat island, no global estimate quantifies air temperature reductions by contemporary or future tree cover, currently and with climate change. Here, we estimate these reductions for all 8,919 large urban areas. Current urban tree cover mitigates 41–49% of the maximum potential air-temperature urban heat island that would occur in the absence of tree canopy. Tree canopy reduces summer air temperature by a population-weighted mean of 0.15 ± 0.03 °C, with wide variation (0.0–2.7 °C), benefiting 914 (805–1040, 95% CI) million people by >0.25 °C. Cooling benefits are greater in already cooler areas: high-income countries and suburbs. Current and plausible future tree cover mitigate only ~10% (6.7–18% and 6.3–17%, respectively) of the median mid-century climate-change warming under a moderate emission scenario. Our results suggest tree canopy expansion in densely settled low-income urban areas is necessary for equitable urban heat island mitigation and climate adaptation.

McDonald, Robert I. [The Nature Conservancy (TNC),

Urban Impacts on Convective Squall Lines over Chicago in the Warm Season—Part I: Observations of Multi-Scale Convective Evolution

In this study, our aim is to diagnose how two quasi-linear convective systems (QLCS) are organized so one can determine the possible role of the city of Chicago, IL, USA, in modifying convective precipitation systems. In this Part I of a two-part study, we employ large-scale analyses, radiosonde soundings, surface observations, and Doppler radar data to diagnose the precursor atmospheric circulations that organize the evolution of two mesoscale convective systems and compare those circulations to radar and precipitation. Several multi-scale processes are found that organize and modify convection over the Chicago metroplex. Two sequential quasi-linear convective systems (QLCS #1 and #2) were organized that propagated over Chicago, IL, USA, during an eight-hour period on 5–6 July 2018. The first squall line (QLCS #1) built from the southwest to the northeast while strengthening as it propagated over the city, and the second (QLCS #2) propagated southeastwards and weakened as it passed over the city in association with a polar cold front. The weak upper-level divergence associated with a diffluent flow poleward of an expansive ridge built over and strengthened a low-level trough and confluence zone, triggering QLCS #1. Convective downdrafts from QLCS #1 produced a cold pool that interacted with multiple confluent low-level jets surrounding and focused on the metroplex urban heat island, thus advecting the convection poleward over the metroplex. The heaviest precipitation occurred just south-southeast of Midway Airport, Chicago. Subsequently, a polar cold front propagated into the metroplex, which triggered QLCS #2. However, the descending air above it under the polar jet and residual cold pool from QLCS #1 rapidly dissipated the cold frontal convection. This represents a case study where very active convection built over the metroplex and was likely modified by it, as evidenced in numerical simulations to be described in Part II.

Kaplan, Michael L.

Estimation of intensity, footprint, and capacity of surface urban heat islands using a direction-enhanced adaptive synchronous extraction (DEASE) method

Here, the surface urban heat island (SUHI) effect, assessed through remotely sensed land surface temperature (LST), remains a focal point in urban climate research. Conventional indicators like SUHI intensity (SUHII) and footprint (SUHIF) capture peak values and spatial extent but fail to account for the cumulative thermal load—a critical dimension reflecting the total heat exposure imposed by spatially continuous warming, which directly limits a holistic assessment of ecological and societal impacts of the SUHI effect. Therefore, this study introduces an indicator termed SUHI capacity (SUHIC), designed to quantify the aggregated SUHI effect by integrating the magnitude of the warming signal across all affected areas, thereby enabling a more comprehensive evaluation of urban thermal environments. Furthermore, a direction-enhanced adaptive synchronous extraction (DEASE) method is proposed for the quantification of SUHIC. This method can dynamically identify the optimal background reference area based on the urban-rural LST gradients in various directions within the city, without relying on predefined mathematical models as previously. The results from 102 European cities first confirm that the directional variations in urban-rural LST gradients, and the DEASE method can effectively capture these distinctions for the simultaneous estimation of SUHII, SUHIF, and SUHIC. Secondly, the spatial patterns of absolute SUHIC values show strong associations with those of SUHIF (R2>0.86), while its relative values (normalized by the area of urban) align more closely with SUHII (R2 > 0.64). More importantly, SUHIC can serve as a crucial reference for assessing the urban thermal signal when SUHII and SUHIF diverge. The proposed method and framework contribute to standardizing the quantification of the SUHI effect.

Indicator

Short-term warming increased soil heterotrophic respiration due to enhanced active microbial community

Soil microbes, particularly active microbes, play a crucial role in conserving soil carbon under climate change, especially in forest ecosystems, constituting over 50% of global soil organic carbon. Nevertheless, the response mechanisms of active microbial community to climate warming and their subsequent impacts on soil heterotrophic respiration (Rh) remain insufficiently understood. To resolve this mechanistic uncertainty, we implemented a 3-year soil translocation experiment to investigate soil warming effects on active microbial community and Rh. We used 16S rRNA gene amplicon sequencing, Metatranscriptomics sequencing, coupled with correlation analyses to explore the linkages between warming-induced shifts in Rh and the active microbial community. Our results demonstrated that warming of soil induced a 55% enhancement in Rh. Concurrently, the Shannon index and Richness of active microbial community increased by 20% and 117%, respectively. Warming significantly altered active microbial community composition, inducing a compositional shift characterized by 0.5-to 2-fold increases in the abundances of Proteobacteria, Chloroflexi, and Actinobacteria. Our study also revealed 92–100% increases in the abundance of C-degradation functional genes encoding starch, cellulose, and lignin decomposition pathways within active microbial community under warming. Statistical analyses identified significant positive correlations between Rh and the abundance of Proteobacteria and Actinobacteria, as well as expression levels of functional genes associated with lignin and cellulose decomposition pathways. Furthermore, our results suggested that short-term warming increased Rh through altering diversity, species composition, and C degradation functional genes of active microbial community providing insights into the influence of microbial communities on soil C-climate feedbacks under climate warming.

Active microbial community

Strategies to mitigate urban heat: Effects on overheating and cloud formation

This study evaluates the effectiveness of various urban heat island (UHI) overheating mitigation strategies and their associated impacts on urban cloud dynamics and thermal processes. This study shows cloud-resolving and urban-resolving modeling results estimating the impact of Houston-Galveston heat mitigation scenarios and other resilient strategies contemplated in the Climate Adaptation Plan and Resilient Houston reports. The simulated scenarios include high intensity green rooftops, rooftop photovoltaic solar panels, enhanced urban irrigation, white/cool roofs and roads, and street trees. We contrast the adaptation scenarios against a present baseline case, a no city scenario and a larger and denser city as projected by the Houston-Galveston Area Council for 2045. During the daytime, cooling strategies such as cool roofs, cool roads, and green roofs exhibit superior performance in mitigating urban overheating. At night, enhanced urban irrigation emerges as the most effective cooling intervention. Cooling strategies significantly reduce sensible heat flux partitioning during the day, a process that reduces the uplift of air, suppressing the formation of urban shallow cumulus clouds. The extent of urban cloud mixing ratio is reduced in proportion to the decrease in sensible heating. Under the BEP-Tree scenario, which includes wind effects and evapotranspiration driven by a stomatal conductance model, urban trees demonstrated negligible environmental cooling effects and minimal urban cloud modifications. In contrast, the scenarios with more urban cooling and higher latent heat fluxes led to suppressed urban clouds. The net cooling effect achieved by the heat mitigation strategies is influenced by a combination of indirect processes, including the reduction of downwelling longwave radiation flux, due to reduced cloud presence, while some warming is attributed to a modest increase in shortwave radiation that offsets the cooling benefit. Additionally, reduced heat dissipation, weakened thermal gradients, and diminished vertical mixing over urban areas further moderate the cooling potential. These findings highlight the pivotal role of clouds and moist atmospheric processes in shaping the UHI effect and offer insights for designing more effective urban cooling strategies.

albedo changes

Recent Widespread Deceleration of Global Surface Urban Heat Islands Unveiled by Satellites

Tracking the temporal dynamics of urban heat island (UHI) is critical for urban heat adaptation and mitigation strategies. However, whether UHI trends have shifted recently and their underlying drivers remain unknown. Here we investigate the variabilities in surface UHI trends and their associated determinants in 2,104 cities worldwide from 2000 to 2022. Our findings reveal that approximately half of the world's cities have experienced notable shifts in surface UHI trends, predominantly characterized by UHI deceleration. These shifts can be primarily attributed to alterations in vegetation trends during the day and to modifications in surface albedo and local warming trends at night. Our study challenges the conventional linear models commonly employed to estimate surface UHI trends, suggesting potential biases in such estimates. Our findings underscore the need for nuanced policies to curtail UHI growth by considering changes in urban underlying surfaces and background climate, particularly from a nonlinear perspective.

54 ENVIRONMENTAL SCIENCES

Reducing Long‐Standing Surface Ozone Overestimation in Earth System Modeling by High‐Resolution Simulation and Dry Deposition Improvement

The overestimation of surface ozone concentration in low‐resolution global atmospheric chemistry and climate models has been a long‐standing issue. We first update the ozone dry deposition scheme in both high‐ (0.25°) and low‐resolution (1°) Community Earth System Model (CESM) version 1.3 runs, by adding the effects of leaf area index and correcting the sunlit and shaded fractions of stomatal resistances. With this update, 5‐year‐long summer simulations (2015–2019) using the low‐resolution CESM still exhibit substantial ozone overestimation (by 6.0–16.2 ppbv) over the U.S., Europe, eastern China, and ozone pollution hotspots. The ozone dry deposition scheme is further improved by adjusting the leaf cuticle conductance, reducing the mean ozone bias by 19%, and increasing the model resolution further reduces the ozone overestimation by 43%. We elucidate the mechanism by which model grid spacing influences simulated ozone, revealing distinctive pathways in urban versus rural areas. In rural areas, grid spacing mainly affects daytime ozone levels, where additional NO x emissions from nearby urban areas result in an ozone boost and overestimation in low‐resolution simulations. In contrast, over urban areas, daytime ozone overestimation follows a similar mechanism due to the influence of volatile organic compounds from surrounding rural areas. However, nighttime ozone overestimation is closely linked to weakened NO titration owing to the redistribution of urban NO x to rural areas. Additionally, stratosphere‐troposphere exchange may also contribute to reducing ozone bias in high‐resolution simulations, warranting further investigation. This optimized high‐resolution CESM may enhance understanding of ozone formation mechanisms, sources, and changes in a warming climate.

54 ENVIRONMENTAL SCIENCES

Mitigating urban climate-energy feedback with citywide building-integrated photovoltaics implementation

Urban heat islands (UHIs) intensify cooling demands, whose waste heat further exacerbates UHI, creating a self-reinforcing feedback loop. Building-integrated photovoltaics (BIPV) can break this cycle by generating electricity and altering urban climate-energy interactions, yet its net impact remains unresolved. Using a cross-scale modeling framework for 118,521 buildings in Hong Kong, we demonstrate that BIPV glazing reduces cooling demand through improved insulation and lower solar heat gain, while inducing diurnal thermal asymmetry of daytime warming (up to +1.9°C) and nighttime cooling (up to −2.5°C). This microclimate regulation indirectly contributes to a 0.6% reduction in citywide building energy use. Cumulative savings from electricity generation and reduced energy use reach 4.7% (2,060.2 GWh) and 10.1% (4,401.3 GWh) under low- and high-coverage deployment, respectively, with building-level savings of −20.1% ± 11.7% (mean ± SD) at high coverage. We establish BIPV as a configurable climate-energy regulator that enables net-zero, heat-resilient planning and quantifies deployment trade-offs in cooling-dominated cities worldwide.

Building-integrated photovoltaics (BIPV)

Data Center Waste Heat as an Emerging Urban Thermal Hazard: First Field Measurements of Neighborhood-Scale Air Temperature Impacts

Data centers are among the fastest-growing sources of concentrated anthropogenic heat in urban environments. Despite heat flux densities that exceed peak solar irradiance by a factor of 2–6, their thermal impacts on adjacent communities have never been directly measured or reported in the peer-reviewed literature. This short communication addresses that gap by presenting the first vehicle-based traverse measurements of air temperature in residential neighborhoods downwind of operational data centers. Five traverses at four facilities in the Phoenix, Arizona metropolitan area, ranging from a 36 MW single-building data center in Mesa to a 169 MW colocation campus in Chandler, reveal downwind air temperature warming as high as 2.2 °C, with average downwind air temperatures 0.7–0.9 °C warmer than corresponding upwind areas. Thermal signatures were detectable at distances up to 500 m from facility perimeters. The 36 MW Mesa facility rejects waste heat equivalent to the electricity consumption of approximately 40,000 households, while the 169 MW Chandler campus is equivalent to over 180,000 households, both concentrated into footprints smaller than a single residential subdivision. With U.S. data center capacity projected to more than double by 2030, these findings establish data center anthropogenic waste heat as a previously undocumented urban thermal hazard demanding attention from the data center and urban planning communities.

Phoenix

How well are hazards associated with derechos reproduced in regional climate simulations?

Abstract. A 15-member ensemble of convection-permitting regional simulations of the fast-moving and destructive derecho of 29–30 June 2012 that impacted the northeastern urban corridor of the USA is presented. This event generated 1100 reports of damaging winds, generated significant wind gusts over an extensive area of up to 500 000 km2, caused several fatalities, and resulted in widespread loss of electrical power. Extreme events such as this are increasingly being used within pseudo-global-warming experiments to examine the sensitivity of historical, societally important events to global climate non-stationarity and how they may evolve as a result of changing thermodynamic and dynamic contexts. As such it is important to examine the fidelity with which such events are described in hindcast experiments. The regional simulations presented herein are performed using the Weather Research and Forecasting (WRF) model. The resulting ensemble is used to explore simulation fidelity relative to observations for wind gust magnitudes, spatial scales of convection (as is manifest in high composite reflectivity, cREF), and both rainfall and hail production as a function of model configuration (microphysics parameterization, lateral boundary conditions (LBCs), start date, use of nudging, compiler choice, damping, and number of vertical levels). We also examine the degree to which each ensemble member differs with respect to key mesoscale drivers of convective systems (e.g., convective available potential energy and vertical wind shear) and critical manifestations of deep convection, e.g., vertical velocities, cold-pool generation, and how those properties relate to the correct characterization of the associated atmospheric hazards (wind gusts and hail). Use of a double-moment, seven-class scheme with number concentrations for all species (including hail and graupel) results in the greatest fidelity of model-simulated wind gusts and convective structure to the observations of this event. All ensemble members, however, fail to capture the intensity of the event in terms of the spatial extent of convection and the production of high near-surface wind gusts. We further show very high sensitivity to the LBCs employed and specifically that simulation fidelity is higher for simulations nested within ERA-Interim compared to ERA5. Excess convective available potential energy (CAPE) in all ensemble members after the derecho passage leads to excess production of convective cells, wind gusts, cREF > 40 dBZ, and precipitation during a frontal passage on the subsequent day. This event proved very challenging to forecast in real time and to reproduce in the 15-member hindcast simulation ensemble presented here. Future work could examine if simulations with other initial and lateral boundary conditions can achieve greater fidelity.

Shepherd, Tristan (ORCID:0000000186276419)

Citizen science coupled with machine learning to quantify green-blue infrastructure cooling potential in Maricopa County, Arizona

Here, this study investigates the spatiotemporal cooling performance of green and blue infrastructure (GBI) in the Dobson Ranch urban neighborhood in Phoenix, Arizona. We leveraged citizen science near-surface (2 m) air temperature (Tair) measurements to train a highly accurate Tair predicting LightGBM machine learning model (R 2 : 0.986, MAE: 0.251 °C, RMSE: 0.585 °C). On June 16, 2024, the park area exhibited approximately 1 °C cooling effect (relative to the neighborhood mean) during both day and night. In contrast, the nearby artificial lake exhibited a stronger cooling effect of 2.4 °C during the day but a slight warming of 0.3 °C at night. At 00:00, locations 50 m downwind of the park were 0.3 °C warmer than the park, while locations 50 m upwind were 0.8 °C warmer. At 11:00, we observed that the downwind area is 0.8 °C cooler and the upwind area is 0.6 °C warmer—at the same 50 m distances relative to the park. We also observed 1 °C cooler and warmer effects respectively at the same 50 m downwind and upwind locations at 19:00 on June 17, 2024. Our data-driven analysis highlights potential limitations of car-traverse measurements, showing that failure to account for temporal variations during the traverse can lead to overestimation of Tair at night and underestimation during the day. Our analysis also showed only a weak correlation (coefficient: 0.48) between Landsat-derived land surface temperature (LST) and model predicted Tair at the time of the local Landsat overpass (∼11.00). This highlights the potential error of relying solely on LST for human thermal exposure analysis—particularly within the heterogenous built-environment.

54 ENVIRONMENTAL SCIENCES

Decomposing a Compound Flood Event in an Urban Pacific Northwest Estuary: Primary Drivers and Projections for the Future

The Duwamish River Estuary (DRE) of Washington is prone to compound flooding during atmospheric river (AR) events. The processes contributing to such flooding (coastal and fluvial) have remained opaque to municipalities that are increasingly impacted. Here, we conduct a suite of coupled atmosphere-hydrology-ocean model simulations with varying forcing combinations (tide, surge, and/or river discharge) to identify the primary drivers of compound flooding during a recent AR event. We also test year 2,100 climate forcing to project how flooding and drivers may change in the future for the same event. We identify a clear distinction between dynamics in the downstream, engineered portion of the DRE compared to the upstream, “natural” river. Downstream, tides dominate water levels but contributions from storm surge and nonlinear tide-surge interaction elevate tide-only high waters from no flooding to major flooding. Upstream, total water levels during the event are ∼6 cm higher than downstream due to an increasing influence of river discharge over surge and tides. Notably, nonlinear surge-river and tide-river interactions act to reduce upstream water levels up to 50% compared to estimates which linearly sum tides, surge, and river, likely reducing flood vulnerability. Under two future climate scenarios: one with only sea level rise (SLR) and another with SLR plus atmospheric warming, we find little change in mechanism contributions to water levels. Expanded flooding in both cases is largely due to SLR, as a ∼50% increase to river discharge under the warming scenario has no impact downstream and marginally increases (∼3 cm) water level upstream.

atmospheric river

Refining seasonal performance metrics for room air-conditioning in emerging markets: Integrating building simulations with real-world equipment performance data

Buildings significantly impact worldwide energy consumption, emphasizing the need to reduce the cooling energy demand, especially in warm climates. Minimum energy performance standards (MEPS) and seasonal performance metrics such as the Cooling Seasonal Performance Factor (CSPF) are crucial for improving room air conditioning (RAC) efficiency. However, challenges remain, particularly in emerging markets like Brazil, where seasonal performance metrics have recently been introduced. This study assesses the factors influencing country-level seasonal efficiency metrics and proposes a framework to refine these calculations by considering local climates and expected RAC usage in real-world households via building simulations. Key considerations include outdoor air temperature binning for different climates, RAC usage patterns (i.e., daytime and nighttime usages), envelope thermal performance of households, and urban heat island (UHI) effects. The results reveal that CSPF values can vary significantly based on climate conditions, with observed CSPF ranging from 4.10 to 11.59 Wh/Wh across 577 Brazilian climates. The inclusion of UHI effects led to a reduction in CSPF values by up to 29% during nighttime operations in hot urban areas. Additionally, building envelope efficiency showed contrasting impacts on RAC performance, with CSPFs reaching up to 15.35 Wh/Wh under specific optimized conditions. These findings highlight the need for transparent policymaking in RAC performance databases, facilitating the application of approaches like those proposed in this study and supporting diverse stakeholders in decision-making.

Bavaresco, Mateus

Life-cycle carbon footprint and total production potential of cross-laminated timber from California’s wildland-urban interface

The frequency, scale, and severity of wildfires are steadily increasing in the Western United States. Sustainable forest management practices through forest thinning could reduce the impact of wildfires and provide lumber for wood-based, long-lived, and low-carbon building materials. This study explores the potential for harvesting biomass in California (CA) to mitigate wildfire risk and provide multi-decade carbon storage in the form of cross-laminated timber (CLT) for use in buildings. First, we assessed biomass resource availability, finding that the total live hardwood and live softwood available in the wildland-urban interfaces (WUIs) across CA sums to 14.1 million metric tons (MMT) and 34.9 MMT, respectively, which contains the equivalent of 90 MMT of atmospheric carbon dioxide. Then, we conducted a life cycle assessment of CLT considering softwood and hardwood sources to provide insights into emissions and energy demand associated with utilization of the wood removed for wildfire risk management. We found that the net life cycle carbon footprint of live hardwood and softwood when including biogenic carbon storage/emissions is 414 and 317 kg CO2e/m3 CLT, respectively. To incorporate the timing of these emissions and uptake, we have also conducted a cradle-to-grave time-dependent global warming potential (GWP) analysis. The time-adjusted GWP for live hardwood and live softwood is −227 and −104 kg CO2e/m3 CLT, respectively. In terms of total CLT production potential, 0.03 and 0.005 million m3 CLT can be sourced from live softwood and hardwood, respectively, in WUI on gentle slopes in CA. The resulting insights and approaches from this study are broadly applicable to other forested regions and WUIs across the US and the world, and provide a holistic approach to use forest thinning as a wildfire mitigation strategy in combination with a novel approach for life cycle assessment of building materials with a limited dataset.

Bose, Baishakhi