Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Unbalanced Three Phase Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Specifying angular reference for robust three-phase state estimation

While the phase angle of any of the bus voltages can be chosen as the angular reference in the state estimation formulation of positive sequence networks, the same approach does not readily extend to three-phase network state estimation problem. It is commonly assumed that there is at least one bus where the bus voltages are perfectly balanced with phase angles displaced ±120° and these balanced three phase voltages are used as the three-phase reference in solving the three-phase state estimation problem. This assumption may be quite realistic in transmission networks, and for distribution networks with a strong transmission system connection. However, it might not be realistic to assume existence of a perfectly balanced reference bus in today’s distribution systems with ever increasing penetration of renewable sources or for isolated operation of microgrids. In this paper, a novel state estimation formulation will be presented which facilitates correct solution irrespective of the existence of buses with perfectly balanced voltages. The new formulation is general, and lends itself to bad data processing. It yields accurate results in any three-phase power system irrespective of its operating conditions (balanced or highly unbalanced), configuration (isolated microgrid, connected to transmission system, etc.) and whether or not it contains any synchronous generators. The performance of the method is validated using the IEEE 123 bus three-phase system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-traffic coordinated operation for bi-peak shaving and bi-ramp smoothing – A hierarchical data-driven approach

The power distribution system and urban transportation system are two networked system bare their own operation constraints, such peak load in power systems and traffic congestion in transportation system. With the increasing number of electrical vehicles and charging/discharging stations, two systems are become tightly coupled. However, to optimize the two systems target using electrical vehicles as decision control variables cannot be easily solved using a uniformed optimization frame work. Thus we propose a hierarchical optimization approach to address this problem, which consists of a higher and a lower level. In the higher level, the power distribution system and urban transportation system are treated together to minimize the social cost. Meanwhile, the electrical vehicles and the charging/discharging stations are treated as customers to minimize their own expenditures. Then, an equilibrium is designed to determine the optimal charging/discharging price. In the lower level, the models of power distribution system and urban transportation system are developed to provide a detailed analysis. Specifically, in power distribution system, the three-phase unbalanced optimal power flow problem is relaxed with the semidefinite relaxation programming, and solved with alternating direction method of multiplier. A dynamic user equilibrium problem is formulated for the urban transportation system. For electrical vehicles, the state of charge is considered to optimize the charging/discharging schedule and reduce the impacts of power distribution systems. We conducted the simulation and numerical analysis using the IEEE 8500-bus distribution system and the Sioux Falls system with about 10,000 cars. The results demonstrate the feasibility and effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Per-phase Phasor Modeling of GFL and GFM Inverters for Distribution System Dynamic Studies

A significant increase in inverter-based distributed energy resources (DERs) is expected in the near future. Existing electromagnetic models and sequential electromechanical models of DERs supporting dynamic analysis cannot be extended to largescale three-phase distribution systems usually with unbalanced construction. As such, there is a need for appropriate industry models that can support distribution system dynamic studies. This paper describes the latest phasor models of grid-following (GFL) and grid-forming (GFM) inverters that can capture distribution system dynamics under grid disturbances. The overall modeling performance is examined and compared with results from other platforms such as controller hardware-in-the-loop (CHIL), MATLAB/Simulink and PSCAD with electromagnetic transient (EMT) and/or phasor simulation capabilities under balanced and unbalanced faults.

Distribution system, Grid modelling, GridLAB-D, Po↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Location Selection of Fast-Charging Station for Heavy-Duty EVs Using GIS and Grid Analysis: Preprint

This work presents a systematic methodology for the location selection of fast-charging stations for heavy-duty Electric Vehicles (EVs) based on both geospatial and electrical grid analysis. The geo-spatial analysis is based on real-world geographic information system (GIS) data of road networks and existing supportive infrastructures. The grid analysis is implemented based on node level analysis of potential impacts on voltages and power losses in distribution system. A case study using realistic three-phase unbalanced distribution feeder from California and extracted real-world GIS data is used to demonstrate the intuitiveness and effectiveness of the proposed methodology for the location selection of fast charging station for heavy duty EVs.

47 OTHER INSTRUMENTATION↗

Location Selection of Fast-Charging Station for Heavy-Duty EVs Using GIS and Grid Analysis

This work presents a systematic methodology for the location selection of fast-charging stations for heavy-duty electric vehicles (EVs) based on both geospatial and electric grid analysis. The geospatial analysis is based on real-world geographic information system (GIS) data of road networks and existing supportive infrastructures. The grid analysis is implemented based on node-level analysis of potential impacts on voltages and power losses in the distribution system. A case study using a realistic, three-phase, unbalanced distribution feeder from California and extracted real-world GIS data is used to demonstrate the intuitiveness and effectiveness of the proposed methodology for the location selection of fast-charging stations for heavy-duty EVs considering both electric and existing transportation infrastructures.

47 OTHER INSTRUMENTATION↗

Role of the Reference Bus in Three-Phase State Estimation

As more and more renewable energy sources are being connected to the power grid at lower voltage levels, closer monitoring of distribution networks is becoming a necessity. This is accomplished by state estimation and deployment of Distribution Management Systems (DMS). Distribution feeders are typically untransposed with unbalance loads. Thus, their modeling and analysis show significant differences compared to those for transmission networks. This paper focuses on the state estimation problem and its formulation for unbalanced distribution systems. Specifically, it is concerned about the modeling and solution of three-phase networks without a fully balanced bus to be selected as the angle reference. It is shown that best results will be obtained via the use of a virtual symmetrical bus. Validation of the proposed formulation is carried out by simulations.

Langner, A. L.↗

CP‐SyNet: A tool for generating customised cyber‐power synthetic network for distribution systems with distributed energy resources

Abstract The integration of distributed energy resources and advancement in information technology has enabled the transition of traditional power distribution systems to active cyber‐physical distribution systems. A growing amount of research has been done on the modelling, analysis, and optimisation of power distribution system behaviour. However, existing publicly available distribution test feeders are limited in numbers and have minimal features. Furthermore, these test feeders do not include cyber models and are not customisable. To bridge this gap, we propose and develop Cyber‐physical synthetic distribution system network (CP‐SyNet), a tool for generating customisable cyber‐physical synthetic distribution test feeders. CP‐SyNet generates three‐phase unbalanced test feeders according to users' requirements, while simultaneously considering both the cyber side and the physical side of the network for cyber‐physical analysis. The physical test network is developed using a graph‐theoretical approach that employs information from existing test feeders. The cyber side considers an equivalent communication network by transforming the physical topology into possible and feasible simulated network. Two examples are presented to demonstrate the feasibility of the proposed framework to generate cyber‐physical test feeders.

Wang, Lusha↗

Analytical Voltage Sensitivity Analysis for Unbalanced Power Distribution System

Large scale integration of distributed energy resources and electric vehicles in a transactive energy environment present new challenges in terms of voltage stability and fluctuations in a power distribution system. The impact of different level of DER/EV penetration on the voltages across the network is typically quantified through voltage sensitivity analyses. Existing methods of voltage sensitivity analysis are computationally expensive and prior efforts to develop analytical approximation lacks generality and have not been effectively validated. The objective of this work is to provide a new analytical method of voltage sensitivity analysis that has low computational cost and also allows for stochastic analysis of voltage change. This paper first derives an analytical approximation of change in voltage at a particular bus due to change in power consumption at other bus in a radial three phase unbalanced power distribution system. Then, the proposed method is shown to be valid for different load configurations, which demonstrates its generality. The results from our analytical approach is validated via classical load flow simulation of the test system based on IEEE 37 bus network. The proposed method is shown to have good accuracy, and computation complexity is of order O(1), compared to O(n3) in classical sensitivity analysis approaches.

Munikoti, Sai↗

Neumann Series Based Voltage Sensitivity Analysis for Three Phase Distribution System

In this letter, a simplified voltage sensitivity analysis technique that can provide accurate estimates of voltage change across the network for a given change in bus power injections in a three-phase unbalanced distribution network is proposed. This technique is derived from the first-order approximation of the Neumann series, which allows maintaining the accuracy of the solution while the computational effort is reduced. Here, the proposed technique is tested on a 559-bus unbalanced distribution system with multiple distributed generation resources. The results show that the average error in the voltage estimates with the proposed method is not more than 0.3% with the execution time of similar order relative to the state-of-the-art sensitivity analysis methods.

42 ENGINEERING↗

Modeling of Grid-Forming and Grid-Following Inverters for Dynamic Simulation of Large-Scale Distribution Systems

Historically, distribution system planning studies mainly focused on steady state and quasi-steady state analysis, with limited attention paid to dynamic analysis. This paper develops three-phase, electromechanical models for both grid-forming and grid-following inverters, and integrates them into an open source, three-phase distribution network solver, thereby enabling dynamic simulation of large-scale, three-phase unbalanced distribution systems with high penetration of inverter-based DERs. The proposed inverter models are validated against electromagnetic simulation and field test data from the CERTS/AEP microgrid testbed, and simulated in an islanded 5252 node distribution system in the GridLAB-D simulation environment. Simulation verifies the effectiveness of the proposed inverter models for large-scale distribution system analysis. Finally, study results show that compared to traditional grid-following inverters, the high penetration of grid-forming inverters can improve the voltage and frequency stability of islanded distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ensuring Solution Uniqueness in Three-Phase Power System State Estimation

This paper is concerned with the issue of potential non-unique solutions in three-phase state estimation. Theory of observability analysis for positive sequence power system state estimation is based on certain assumptions that avoid possibility of multiple solutions. Also, it is shown that observability of a positive sequence network remains independent of the network parameters or the operating state. When extending single-phase observability analysis directly to the three-phase case, this paper considers the possibility of converging to multiple solutions, i.e. solution non-uniqueness, even for cases where state estimator successfully converges. The study illustrates via numerical examples the likelihood of converging to entirely different solutions for certain network parameters. It also examines how the operating state, particularly under unbalanced loading, leads to solution non-uniqueness. The paper then describes an alternative approach to ensure a unique solution in three-phase state estimation. This method aims to accurately and uniquely estimate the state of any unbalanced three-phase system, irrespective of load imbalance, network configuration, existence of synchronous generators or transformers.

Power System State Estimation, Three-Phase, Distri↗

Three‐phase probabilistic load flow in radial and meshed distribution networks

With the introduction of higher levels of renewables and demand response programs, traditional deterministic power system tools fall short of expectations. Probabilistic load flow (PLF) takes into account the inconsistency or the unknown loads, and generation in the fundamental load flow analysis. This study proposes a PLF solution for both balanced and unbalanced, radial and weakly meshed networks without explicitly using the Y ‐bus matrix. It allows for discrete probability density functions as input variables without having to assume a predefined distribution. The nodal voltages and the power flows can be calculated independently from one another. The proposed method is applied to the IEEE 123 Node Test Feeder and the IEEE 13 Node Test Feeder in both its original radial configuration and a modified mesh configuration, including a load replaced with a wind turbine. The results are validated by comparison of the proposed method's solutions to those obtained using cumulants and Monte Carlo simulation. The proposed PLF method provides an accurate and practical way for finding the solution to stochastic problems occurring in power distribution systems allowing for real‐system data to be analysed.

Melhorn, Alexander C.↗

A Data-Driven Global Sensitivity Analysis Framework for Three-Phase Distribution System with PVs

Global sensitivity analysis (GSA) of distribution systems with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution systems. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of PV and load power injections. The sampling-based method approximates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-node distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.

14 SOLAR ENERGY↗

Steady-State Modeling of Modular Multilevel Converter Under Unbalanced Grid Conditions

This paper presents a steady-state model of MMC for the second-order phase voltage ripple prediction under unbalanced conditions, taking the impact of negative-sequence current control into account. From the steady-state model, a circular relationship is found among current and voltage quantities, which can be used to evaluate the magnitudes and initial phase angles of different circulating current components. Moreover, in order to calculate the circulating current in a point-to-point MMC-based HVdc system under unbalanced grid conditions, the derivation of equivalent dc impedance of an MMC is discussed as well. According to the dc impedance model, an MMC inverter can be represented as a series connected R-L-C branch, with its equivalent resistance and capacitance directly related to the circulating current control parameters. Experimental results from a scaled-down three-phase MMC system under an emulated single-line-to-ground fault are provided to support the theoretical analysis and derived model. In conclusion, this new models provides an insight into the impact of different control schemes on the fault characteristics and improves the understanding of the operation of MMC under unbalanced conditions.

30 DIRECT ENERGY CONVERSION↗

Visual Tool for Assessing Stability of DER Configurations on Three-Phase Radial Networks

Here, we present a method and tool for evaluating the placement of Distributed Energy Resources (DER) on distribution circuits in order to control voltages and power flows. Our previous work described Phasor-Based Control (PBC), a novel control framework where DERs inject real and reactive power to track voltage magnitude and phase angle targets. Here, we employ linearized power flow equations and integral controllers to develop a linear state space model for PBC acting on a three-phase unbalanced network. We use this model to evaluate whether a given inverter-based DER configuration admits a stable set of controller gains, which cannot be done by analyzing controllability nor by using the Lyapunov equation. Instead, we sample over a parameter space to identify a stable set of controller gains. Our stability analysis requires only a line impedance model and does not entail simulating the system or solving an optimization problem. We incorporate this assessment into a publicly available visualization tool and demonstrate three processes for evaluating many control configurations on the IEEE 123-node test feeder (123NF).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characteristic investigation and control of a modular multilevel converter-based HVDC system under single-line-to-ground fault conditions

This paper presents the analysis and control of a multilevel modular converter (MMC)-based HVDC transmission system under three possible single-line-to-ground fault conditions, with special focus on the investigation of their different fault characteristics. Considering positive-, negative-, and zero-sequence components in both arm voltages and currents, the generalized instantaneous power of a phase unit is derived theoretically according to the equivalent circuit model of the MMC under unbalanced conditions. Based on this model, a novel double-line frequency dc-voltage ripple suppression control is proposed. This controller, together with the negative-and zero-sequence current control, could enhance the overall fault-tolerant capability of the HVDC system without additional cost. To further improve the fault-tolerant capability, the operation performance of the HVDC system with and without single-phase switching is discussed and compared in detail. Lastly, simulation results from a three-phase MMC-HVDC system generated with MATLAB/Simulink are provided to support the theoretical analysis and proposed control schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BEEAM (Building Electrical Efficiency Analysis Model) [SWR-20-107]

Modern high-performance buildings exhibit an increasing number of building loads that use direct current (DC) electricity internally, rather than alternating current (AC), due to the advent of low-cost computing and advanced power electronics. Powering DC devices from the AC grid requires AC/DC power conversion, which introduces energy losses and reduces efficiency. As DC loads proliferate, the cumulative wasted energy associated with hundreds of millions of AC/DC converters has become one of the broadest energy savings opportunities in buildings. DC power distribution systems have been proposed as an elegant and transformative solution to the problem of DC devices. In a DC distribution system, the building's wires carry DC electricity, rather than AC; and a few centralized, highly efficient AC/DC converters replace the many smaller, less efficient converters that serve individual DC loads. Unfortunately, the trade-offs associated with DC distribution systems are not well understood. Reported energy savings associated with DC power distribution differ widely and have not been well validated. The Building Electrical Efficiency Analysis Model (BEEAM) is a Modelica library that simulates the efficiency of building electrical distribution systems using harmonic power flow. BEEAM can model a wide variety of building distribution topologies, including three-phase AC, single-phase AC, unipolar DC, bipolar DC, and hybrid networks under both balanced and unbalanced load conditions. BEEAM accurately models power electronic converter losses, provides granular estimates of losses throughout the distribution system, and properly models efficiency at part load conditions. Users can package BEEAM within a functional mockup unit (FMU), enabling co-simulation with other modeling platform, such as EnergyPlus. In summary, BEEAM provides a tool suite for fair and accurate comparison of the efficiency of building electrical distribution systems, including AC, DC, and hybrid systems.

Frank, Stephen↗