Ultrasonic Thermometer Sticking Mitigation Assessment

Ultrasonic thermometers have potential to improve on current technologies for very high temperature measurements. One issue limiting their adoption is the formation of diffusion bonds between the acoustic waveguide used as the sensor, and its surroundings (in some cases, a protective sheath). Several potential methods for reducing this diffusion bonding (known as sticking) have been identified. Prototype ultrasonic thermometers were fabricated and tested to high temperatures in order to evaluate these methods. Several showed promise for low temperature use. The most promising option was 3-D printed ceramic spacers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of INL Ultrasonic Thermometer

This document summarizes the development at Idaho National Laboratory of an ultrasonic thermometer. The ultrasonic thermometer is a temperature sensor capable of multi-point measurements at very high temperatures with a high level of radiation tolerance. All of the components of the ultrasonic thermometer have been improved over the course of this work. The base technology, a magnetosrictive transducer, has been shown to be highly radiation tolerant. The solenoidal coil used in the transducer has been redesigned to operate at higher frequencies that previously possible. Materials used for the acoustic waveguide (the sensing portion of the device) have been tested and ideal candidates identified. Finally, a solution to the sticking issue (diffusion bonding between the waveguide and a protective sheath) has been developed and tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of an Ultrasonic Thermometer Developed at the Idaho National Laboratory

Ultrasonic thermometry has great potential to improve temperature measurements in irradiation experiments performed in nuclear test reactors. The flexibility of the measurement makes it applicable to a wide range of potential test conditions, in terms of temperature, radiation, and chemical environment. However, the range of several typical ultrasonic thermometer configurations are not well defined. The research described in this document attempts to define an operational envelop for multiple configurations and sensor materials.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers

Daw, J.↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 . A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation.

Daw, Joshua↗

Magnetostrictive Ultrasonic Waveguide Transducer for In-Pile Thermometry

Real-time and reliable temperature measurement on nuclear fuels is crucial for the safe operation of existing pressurized-water reactors and future advanced nuclear reactors. Magnetostrictive materials deform when subjected to a magnetic field or exhibit magnetization variation when stressed. Here, based on these properties, this study prototyped an ultrasonic thermometer (UT) consisting of a magnetostrictive waveguide, a dc coil providing appropriate magnetic biasing, and an ac coil generating an acoustic impulse and detecting the resulting acoustic echoes. By tracking the time of flight between the excitation pulse and the echoes, the UT can potentially detect nuclear fuel cladding temperature from a long distance. In this study, magnetostrictive iron–gallium alloys, or Galfenol, were selected as the waveguide due to their large magnetostriction, superior temperature survivability, excellent radiation resilience, and high mechanical robustness. A multiphysics finite-element model considering electrical, magnetic, and mechanical dynamics in the magnetostrictive UT was then developed. The model exhibited an error of 0.24% in time-of-flight simulation and, therefore, enabled computer-aided design and guided signal processing. Between room temperature and 120 °C, the new Galfenol-based UT exhibits a linear sensitivity of 162.8×10 ₋6 °C ₋1 , which is 51.7% higher than a previous magnetostrictive UT based on iron–cobalt–vanadium alloys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System Measures Loads In Bolts

Improved technique for ultrasonic nondestructive measurement of loads in bolts involves use of pulsed phase-locked loop interferometer. Provides for correction of errors and for automatic readout of loads in bolts. Actual bolt load measured, using transducers rebonded after bolts tightened. Calibration block and thermometer added. Technique applicable to critical fasteners in aerospace applications, nuclear reactors, petroleum and other chemical processing plants, steel bridges, and other structures.

Allison, Sidney G.↗

Aerosol jet printing of piezoelectric surface acoustic wave thermometer

Abstract Surface acoustic wave (SAW) devices are a subclass of micro-electromechanical systems (MEMS) that generate an acoustic emission when electrically stimulated. These transducers also work as detectors, converting surface strain into readable electrical signals. Physical properties of the generated SAW are material dependent and influenced by external factors like temperature. By monitoring temperature-dependent scattering parameters a SAW device can function as a thermometer to elucidate substrate temperature. Traditional fabrication of SAW sensors requires labor- and cost- intensive subtractive processes that produce large volumes of hazardous waste. This study utilizes an innovative aerosol jet printer to directly write consistent, high-resolution, silver comb electrodes onto a Y-cut LiNbO 3 substrate. The printed, two-port, 20 MHz SAW sensor exhibited excellent linearity and repeatability while being verified as a thermometer from 25 to 200 ∘ C. Sensitivities of the printed SAW thermometer are $$-96.9\times 1{0{}^{-6}}^{\circ }$$ − 96.9 × 1 0 − 6 ∘ C −1 and $$-92.0\times 1{0{}^{-6}}^{\circ }$$ − 92.0 × 1 0 − 6 ∘ C −1 when operating in pulse-echo mode and pulse-receiver mode, respectively. These results highlight a repeatable path to the additive fabrication of compact high-frequency SAW thermometers.