Burst delay line for generating ultrashort pulse bursts with interval tunability from femtoseconds to nanoseconds.

Ultrashort burst laser pulses are important for applications in laser processing and spectroscopy. However, existing burst generators face limitations in pulse time interval tunability and coaxiality. Here, we present a burst pulse generator that delivers coaxial ultrashort pulses with tunable pulse time intervals using a single translation stage. The constructed system produced eight femtosecond pulses with uniform intervals tunable from 100 fs to 1.93 ns, equivalent to burst-internal repetition rates spanning 10 THz to 0.52 GHz. We further demonstrated interval-dependent plasma emission in air filamentation, providing a compact platform to study burst-laser-induced phenomena.

Shimada, Keitaro

Extended X-ray absorption spectroscopy using an ultrashort pulse laboratory-scale laser-plasma accelerator

Laser-driven compact particle accelerators can provide ultrashort pulses of broadband X-rays, well suited for undertaking X-ray absorption spectroscopy measurements on a femtosecond timescale. Here the Extended X-ray Absorption Fine Structure (EXAFS) features of the K-edge of a copper sample have been observed over a 250 eV window in a single shot using a laser wakefield accelerator, providing information on both the electronic and ionic structure simultaneously. This capability will allow the investigation of ultrafast processes, and in particular, probing high-energy-density matter and physics far-from-equilibrium where the sample refresh rate is slow and shot number is limited. For example, states that replicate the tremendous pressures and temperatures of planetary bodies or the conditions inside nuclear fusion reactions. Using high-power lasers to pump these samples also has the advantage of being inherently synchronised to the laser-driven X-ray probe. A perspective on the additional strengths of a laboratory-based ultrafast X-ray absorption source is presented.

43 PARTICLE ACCELERATORS

Active control of laser beam pointing for the Zettawatt-Equivalent Ultrashort pulse laser System: a proof-of-principle study with 16-inch optics

We present a proof-of-principle study of active beam-pointing control for the Zettawatt-Equivalent Ultrashort pulse laser System (ZEUS) using a piezo-actuated 16-inch mirror. To the best of our knowledge, this is the largest actively controlled mirror reported in a high-power laser system. A simple proportional feedback control was implemented based on a field-programmable gate array, which reduced the standard deviation of beam-pointing fluctuations by 91% to 0.075 μrad in the horizontal direction and by 78% to 0.25 μrad in the vertical direction. We also demonstrated the elimination of long-term pointing jitter caused by temperature drift using the same apparatus.

laser pointing control

Ultrashort pulse generation in semiconductor lasers

Techniques to generate picosecond optical pulses from semiconductor lasers are reviewed. Experimental methods and results of theoretical analysis of active modelocking are presented. It is shown that modelocking will achieve the shortest pulses; but the use of a cumbersome external cavity will probably limit its practical use. Short pulses produced by direct modulation such as gain switching are considerably broader than those obtained by passive modelocking. However, no external cavity is needed; and the simplicity of this method makes it important to be explored further. Recent experimental results are discussed where picosecond pulses from a buried heterostructure laser diode with ultrashort current pulses obtained from a comb generator are generated. Also, 28 ps pulses were obtained at 2.5 GHz repetition frequency, using the gain switching method. An analytical analysis based on the rate equations shows qualitative agreement with our experimental results.

Auyeung, J.

Ultrashort Pulsed Laser Treatment: A Novel Sterilization Method for Planetary Protection

Introduction: On missions seeking signs of potential life elsewhere in the solar system, we have an obligation not to bring our own Earthly life with us. Reducing the bioburden (number of living microbes) on spacecraft is therefore required by the COSPAR Policy on Planetary Protection to target bodies that are of interest for understanding the origins of life (such as Mars). The method of spacecraft sterilization predominantly used by NASA is Heat Microbial Reduction, which is typically incompatible with heat-sensitive components such as optics and electronics, and is expensive and time-consuming. Here, we present preliminary results on a novel method for spacecraft hardware sterilization: high-intensity ultrashort (femtosecond) pulsed laser illumination. Femtosecond lasers use extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. This rapid sterilization technique could be carried out in situ in a spacecraft assembly clean room using high-speed surface scanning, saving critical time and resources. It also can potentially remove or reduce debris from inactivated cells and spores. Methods: To develop optimal laser processing parameters for inactivating planetary protection-relevant organisms on metal surfaces, we inoculated 1-cm^2 mirror-polished aluminum coupons with Bacillus subtilis spores (2x10^5 spores/coupon) and tested the effect of several parameters, including pulse count and fluence. Sterilization effectiveness was measured by recovering spores using a PVA (polyvinyl acetate) peel and conducting serial dilution and plating for colony-forming units (CFUs). Results: Our results show that pulse count and fluence both affect sterilization effectiveness and that within a certain pulse count range, increasing fluence increases effectiveness. We have demonstrated the ability to reduce viable microbial counts by at least 10^-4. Future work will include testing higher abundances and different species of microorganisms, effectiveness on complex surfaces, compatibility with sensitive surfaces, and quantification of cell debris removal. Femtosecond pulsed laser illumination has the potential to provide dramatic savings in both cost and schedule over current methods of bioburden reduction to prevent forward contamination. It may also have the potential for use in surface sterilization of returned samples to prevent back contamination.

Planetary Protection; Lasers; Sterilization; Bacil

Ultrashort pulse solid-state transmitter development

A pulsed, actively mode-locked, pulse-transmission-mode (PTM) Q-switched Nd:YAG laser has been developed for a planned NASA spaceborne precision ranging system. The laser emits single, 150-psec, 20-mJ pulses at 10 pulses per second at 1.064 micrometers.

Harper, L. L.

On the Theory of High-Power Ultrashort Pulse Propagation in Raman-Active Media

The propagation of an intense femtosecond pulse in a Raman-active medium is analyzed. An analytic solution which describes in explicit form the evolution of the light pulse is derived. The field of an intense light wave undergoes a substantial transformation as the wave propagates through the medium. The nature of this transformation can change over time scales comparable to the period of the optical oscillations. As a result, the pulse of sufficiently high energy divides into stretched and compressed domains where the field decreases and increases respectively.

Belenov, E. M.

Ultrashort Pulse Laser Surface Processing Techniques for Sterilization of Metal Surfaces for Planetary Protection

To prevent forward contamination from microbes aboard spacecraft intended to search for extraterrestrial life, there is a need for effective sterilization methods. However, current techniques are both time-consuming and expensive. For example, dry heat sterilization requires removal from the assembly site and several days of treatment. Furthermore, some components such as optics and electronics are not compatible with current sterilization techniques. Here, we report the latest results in our development of a novel femtosecond laser processing technique for the rapid sterilization of spacecraft hardware. Femtosecond lasers produce extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. Aluminum coupons were inoculated with specific densities of Bacillus subtilis bacterial endospores. These coupons were treated with various laser illumination parameters. Afterward, metal coupon samples were assayed for viable spores using a polyvinyl alcohol (PVA) peel, serial dilution, and plating for colony-forming units (CFU). Results indicate that with high enough energy density and pulse counts, most bacterial spores are inactivated with minimal damage to the metal. The sterilization is dependent on both the fluence and pulse count. In addition, femtosecond pulses are more effective than longer pulses for inactivation. These experiments have consistently achieved 4-log reduction in viable spores. Sterilization has been achieved on both flat metal coupons and non-flat surfaces with microchannels, with a slight reduction in sterilization efficiency on the uneven surface. The application of air flow during laser processing was also investigated as a way to remove spores that are dislodged from the surface by the laser illumination, which would contribute to the reduction of spacecraft bioburden. With laser processing technology rapidly evolving, our results support the possibility of an extremely rapid, in-situ surface sterilization method for use in spacecraft assembly clean rooms.

Kaleb McQuillan

Reliable Determination of Pulses and Pulse-Shape Instability in Ultrashort Laser Pulse Trains Using Polarization-Gating and Transient-Grating Frequency-Resolved Optical Gating Using the RANA Approach

Devices that measure the presence of instability in the pulse shapes in trains of ultrashort laser pulses do not exist, so this task necessarily falls to pulse-measurement devices, like Frequency-Resolved Optical Gating (FROG) and its variations, which have proven to be a highly reliable class of techniques for measuring stable trains of ultrashort laser pulses. Fortunately, multi-shot versions of FROG have also been shown to sensitively distinguish trains of stable from those of unstable pulse shapes by displaying readily visible systematic discrepancies between the measured and retrieved traces in the presence of unstable pulse trains. However, the effects of pulse-shape instability and algorithm stagnation can be indistinguishable, so a never-stagnating algorithm—even when instability is present—is required and is generally important. In previous work, we demonstrated that our recently introduced Retrieved-Amplitude N-grid Algorithmic (RANA) approach produces highly reliable (100%) pulse-retrieval in the second-harmonic-generation (SHG) version of FROG for thousands of sample trains of pulses with stable pulse shapes. Further, it does so even for trains of unstable pulse shapes and thus both reliably distinguishes between the two cases and provides a rough measure of the degree of instability as well as a reasonable estimate of most typical pulse parameters. Here, we perform the analogous study for the polarization-gating (PG) and transient-grating (TG) versions of FROG, which are often used for higher-energy pulse trains. We conclude that PG and TG FROG, coupled with the RANA approach, also provide reliable indicators of pulse-shape instability. In addition, for PG and TG FROG, the RANA approach provides an even better estimate of a typical pulse in an unstable pulse train than SHG FROG does, even in cases of significant pulse-shape instability.

47 OTHER INSTRUMENTATION

Maxwell-Bloch Equations Modeling of Ultrashort Optical Pulse Propagation in Semiconductor Materials

An algorithm has been developed that solves the semiconductor Maxwell-Bloch equations, without making the standard slowly-varying envelope (SVEA) and rotating-wave (RWA) approximations. It is applied to study the propagation of ultrashort pulses in semiconductor materials. The results include many-body effects due to the Coulomb interaction among the charge carriers as well as the nonlinear effects resulting from spectral hole-burning.

Goorjian, Peter M.

In situ characterization of two unknown ultrashort laser pulses using four-wave mixing in gas

Accurate characterization of two ultrashort laser pulses is of great interest in many ultrafast pump-probe experiments. We demonstrate a method based on four-wave mixing (FWM) in a gas which could be easily implemented into many existing pump-probe setups with minimal modifications for accurate, in situ characterization of both unknown pulses. This technique is tested on pairs of unknown pulses at wavelengths of 400/800 nm, and 266/400 nm. We measured the spectrogram of the pulse generated through FWM of the two unknown pulses by scanning the delay between two unknown pulses. The retrieval algorithm converges to accurately predict the intensity and the phase profiles of both unknown pulses with a trace error of < 1% and the accuracy is verified using an independent pulse characterization device.

Nambu, Noa (ORCID:0000000197303400)

New methods of generation of ultrashort laser pulses for ranging

To reach the millimeter satellite laser ranging accuracy, the goal for nineties, new laser ranging techniques have to be applied. To increase the laser ranging precision, the application of the ultrashort laser pulses in connection with the new signal detection and processing techniques, is inevitable. The two wavelength laser ranging is one of the ways to measure the atmospheric dispersion to improve the existing atmospheric correction models and hence, to increase the overall system ranging accuracy to the desired value. We are presenting a review of several nonstandard techniques of ultrashort laser pulses generation, which may be utilized for laser ranging: compression of the nanosecond pulses using stimulated Brillouin and Raman backscattering; compression of the mode-locked pulses using Raman backscattering; passive mode-locking technique with nonlinear mirror; and passive mode-locking technique with the negative feedback.

Jelinkova, Helena