Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Ultra-high vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]

Design, development and commissioning of a multi-alkali semiconductor photocathode deposition system for the IUAC Delhi light source photoinjector

A fourth-generation light source, called Delhi Light Source (DLS) based on photocathode-based RF gun has been commissioned at Inter-University Accelerator Centre, New Delhi. Presently, the electron beam is being generated from copper photocathode and the beam is being used for scheduled experiments. Soon, the semiconductor photocathode will be used to produce higher beam current. Here, to develop the semiconductor photocathode, a dedicated photocathode deposition facility was developed in collaboration with Brookhaven national Laboratory (BNL) and has been successfully commissioned and becomes operational at IUAC. This deposition facility is an integrated system with the electron gun and is a unique system as it is capable of producing, preserving (without residual gas poisoning) and in-vacuum transfer of the deposited photocathodes from the deposition chamber up to the RF electron gun. The system is designed to operate under ultra-high vacuum (UHV) and is equipped with load-lock chambers, substrate heating assembly, thickness monitoring via a quartz crystal microbalance (QCM), and an in-situ setup for quantum efficiency (QE) measurements. After testing of all the subsystems and a detailed calibration, the first deposition of a cesium telluride (Cs 2 Te) photocathode was successfully performed on a copper (Cu) substrate. This successful commissioning and initial deposition mark a significant step toward the indigenous photocathode development and lays the groundwork for further research into advanced photo emissive materials at IUAC. This paper will discuss the salient features, installation, commissioning, first semiconductor photocathode deposition and its results.

47 OTHER INSTRUMENTATION

Atomic‐Scale Surface Imaging of Bulk Epitaxial CsPbBr 3 Perovskite Single Crystals on Mica Using Light Assisted Scanning Tunneling Microscopy at Low‐Temperature (80 K)

Epitaxial single-crystalline CsPbBr 3 perovskite films on mica, prepared ex situ, are explored using a low-temperature scanning tunneling microscope (STM) by probing the unoccupied electronic states of their surface in ultra-high vacuum (UHV) at 80 K. Light-assisted STM measurements under a broadband illumination with visible light were employed to enhance and stabilize surface conductivity. STM imaging across the surface of macroscopic bulk CsPbBr 3 films reveals large flat terraces characterized by a specific type of surface reconstruction, consisting of parallel rows of U-shaped atomic nanostructures. These structures are spaced by 12 Å and exhibit an internal feature size of 5.1 Å. Density functional theory (DFT) calculations reproduce the experimental observations and reveal a competition between different orthorhombic CsPbBr 3 (110) surface reconstructions: a Cs-rich structure, identified as the most energetically stable, and three alternative Pb–Br-rich reconstructions, which are slightly higher in energy yet remain consistent with the STM data. Additional analyses that explicitly account for the mica substrate exclude the cubic CsPbBr 3 phase and other orthorhombic surface orientations, while showing that variations in the mica surface termination do not alter the preferred CsPbBr 3 (110) reconstruction. In conclusion, this combined approach thereby confirms our assignment and resolves previous STM interpretations of CsPbBr 3 .

36 MATERIALS SCIENCE

Removal of deuterium retained in boron powder by oxygen or high-temperature bakeout

Fuel retention in dust accumulated in fusion devices is a potential operational hazard. Boronization is one of the leading wall-conditioning candidates for future fusion devices. Fuel retention characteristics of boron dust must be studied to accurately understand the potential hazards of boron dust in fusion devices. We evaluated the retention of deuterium (D) in commercially available boron powder as a proxy for tritium retention in boron dust. Diffuse reflectance infrared Fourier transform spectroscopy revealed that boron powder between 300 and 500 K exposed to neutral hydrogen (H 2 ) gas retains H via B-H bonding. We utilized D 2 exposures of 17,400 L on the boron powder, which led to retention on the order of 0.5 g D per 100 kg B or 1.2 g D per m 2 B, as estimated from temperature programmed desorption measurements. We evaluated how powder bakeouts under ultra-high vacuum (UHV), or in an oxygen (O 2 ) or H 2 gas backfilled environment can remove the retained fuel. Bakeouts below 523 K under UHV exhibited poor D removal, promoting recapture of D 2 present as background gas in the chamber. Higher temperature bakeouts led to the removal of over 80% of the retained D within 3 days (623 K) or 1 h (723 K). Bakeouts at 423 K under an O 2 gas environment removed ∼150% more retained D from the boron powder, when compared to bakeouts conducted under UHV. These results suggest that efficient fuel removal from boron dust can be achieved by high-temperature bakeout (>623 K) or by bakeouts at lower temperature (423 K) under an O 2 environment.

Bakeout

In Situ Analysis of Manganese Antimonate Oxygen Evolution Electrocatalysts via Ambient Pressure X-ray Photoelectron Spectroscopy

Here, manganese antimonates are earth-abundant potential alternatives to precious metal catalysts for the oxygen-evolution reaction (OER). Herein, X-ray photoelectron spectroscopy was used to determine the surface chemistry of a manganese antimonate catalyst for the OER under ultra-high vacuum, ambient pressure, and in situ reaction conditions. Ex situ and in situ analysis revealed the oxidation states of surficial species as a function of material stoichiometry, water content, and applied potential. In situ XPS measurements in 1.0 M KOH(aq) indicated that relative to the rest state, the surface Mn(III) partially oxidized while effecting the OER, with approximately 15% of the Mn signal attributable to Mn(IV) and the remainder attributable to Mn(III).

36 MATERIALS SCIENCE

Evolution of Electronic Properties of Graphene Nanoribbons with Progressive Carving: From Straight to Porous to Chevron Ribbons

Graphene nanoribbons (GNRs) are highly versatile materials due to their unique electronic, magnetic, and optical properties, which can be precisely tuned by controlling their width, edge structure, and topology. Here, we report the on-surface synthesis and characterization of a straight N = 15 armchair GNR with periodic annulene nanopores (15-pGNR). It serves as a structural link between two well-established GNRs: the pristine N = 15 armchair GNR without pores (15-AGNR) and the chevron GNR (cGNR). With the addition of the 15-pGNR reported in this study, these three GNRs form a rare experimentally accessible series of ribbons, in which the evolution of electronic properties can be tracked upon progressive carving of a basic 15-AGNR: first, by creating periodic nanopores to form 15-pGNR and then by extending the pore area and producing meandering cGNR. We have designed a molecular precursor for the 15-pGNR and grown the nanoribbons on single-crystal gold substrates by on-surface synthesis in ultra-high vacuum (UHV) conditions. The atomically precise structure of 15-pGNR was confirmed by scanning tunneling microscopy (STM) and non-contact atomic force microscopy (nc-AFM). The band gap of 15-pGNR was studied by scanning tunneling spectroscopy (STS) and dI/dV mapping, and the occupied electronic levels were investigated by angle-resolved photoemission spectroscopy (ARPES). A theoretical and experimental comparison of 15-pGNRs, 15-AGNRs, and cGNRs demonstrates that the introduction of periodic nanopores into 15-AGNR leads to a more than 2-fold increase in its band gap. In contrast, the band gaps of 15-pGNR and cGNR differ only by about 15%. Such band gap increase can be qualitatively understood to arise from two combined effects, the periodic perforation of the graphene lattice and the confinement effect induced by the GNR width.

77 NANOSCIENCE AND NANOTECHNOLOGY

Correlating binding energies of adsorbed CO and H on model surfaces with CO/H 2 selectivity from co-electrolysis of CO 2 and H 2 O over copper–palladium bimetallic catalysts

Binding energies of adsorbed CO and H are key descriptors governing the activity and selectivity of the co-electrolysis of CO 2 and H 2 O to produce syngas with desired CO/H 2 ratios. Palladium hydride (PdH), which forms in situ at negative overpotentials, has been identified as the active Pd phase for CO 2 reduction to syngas. Herein, binding energies of CO and H are determined using temperature programmed desorption (TPD) of CO and H 2 from Pd(111), PdH/Pd(111), and Cu/PdH/Pd(111) under ultra-high vacuum (UHV) conditions. TPD results reveal that desorption of H 2 from subsurface PdH occurs at 460 K, while desorption from surface PdH is more facile at 320 K. CO desorption temperatures shift 20 K lower on PdH/Pd(111) compared to on Pd(111). The presence of 0.7 ML Cu further increases the desorption temperature of H 2 by 30 K while simultaneously reducing CO desorption temperatures by 70 K. Density functional theory (DFT) calculations show that CO adsorption onto Pd sites is hindered on the 0.7 ML Cu/PdH/Pd(111) surface while the kinetic barrier for H 2 desorption is increased. The trends in the binding energies of CO and H on model surfaces are consistent with electrochemical measurements of CuPd powder catalysts in a membrane electrode assembly (MEA), where H 2 evolution is reduced while CO production is enhanced compared to unmodified Pd catalysts. Overall, the results from model surface studies (TPD and DFT) provide a prediction and explanation for the activity and CO/H 2 ratios observed in electrochemical experiments. This study also demonstrates that CuPd is a promising catalyst with reduced Pd-loading to produce CO-rich syngas.

36 MATERIALS SCIENCE

Evolution of size-selected Pt cluster catalysts on prototypical oxide supports

The current quest for new pathways into sustainable, efficient and durable energy conversion technologies makes the used for a fundamental understanding of the atomic-scale phenomena underlying catalytic processes ever more pressing. In this context, characterizing catalyst particles in situ provides valuable information about the evolution of their composition, structure, oxidation state and charge state during an ongoing process. To disentangle the influence of individual parameters – temperature, pressure, gas composition, cluster size, as well as support acidity, redox state and defect density – it is crucial to control them precisely and separately in experiments. At the example of size-selected Pt n clusters – i.e. sub-nm particles defined to the exact number of atoms – on flat oxide supports, we follow their rich evolution phenomena via (synchrotron-based) X-ray photoelectron spectroscopy (XPS) and scanning tunnelling microscopy (STM) during temperature ramps and in various gas environments. Here, we present our experience with these highly defined, yet complicated-to-create samples in ultra-high vacuum (UHV) and at mbar pressures. We discuss their stability during transport to synchrotrons and under reaction conditions on three prototypical oxide supports and show the various phenomena that can be disentangled. Ptn clusters on the non-reducible silicon dioxide, SiO 2 , remain size-selected and show remarkable stability. Doping strongly influences the size-dependent binding energy shifts and changes the Pt response to oxidative and reaction conditions, which we attribute to different cluster geometries: p-type doping leads to wetting, enhanced sinter resistance and a diminished response to oxidative environments, compared to clusters on n-type doped samples. We compare the system with our previous findings of a similar change in dimensionality for Pt 20 clusters on the reducible ceria, CeO 2 (111), support, induced by modulation of its O vacancy density. The Pt n /CeO 2 system is particularly interesting for strategies to stabilize and redisperse Pt clusters dynamically. Finally, we study the evolution of Pt n clusters on another reducible oxide support, magnetite, Fe 3 O 4 (001), in 0.1 mbar alternating redox conditions at RT and elevated temperature. In analogy to findings previously reported for Pt/TiO 2 (110), the clusters either become encapsulated by a thin oxide film via strong metal–support interaction (SMSI) or deeply buried in the magnetite. Overall, our approach of following the evolution of size-selected clusters on oxide supports leads to fundamental atomic-scale insights on nano-scale catalyst materials, on our path to sustainable, dynamic and self-repairing catalysts.

Falling, Lorenz J. [Technical Univ. of Munich (Ger

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, G. [Thomas Jefferson National Accelerator

Correlating Nb-SRF Surface Processing with Evolution of Surface Electronic States

The few nanometers of the surface exposed to RF field plays a major role in defining the RF performance of superconducting cavities. Over the past two decades, several pioneering surface treatment and processing methods have emerged, enabling remarkable improvements in cavity performance by simultaneously achieving high Q with increasing Eacc. These processing methods include: thermal treatment under ultra-high vacuum (UHV) conditions across lo¬¬¬¬¬¬¬w-, mid-, and high-temperature ranges and high temperature treatments under controlled N2 atmosphere. These processes also produce distinct surface oxide configurations with different valence states, thicknesses, and uniformity, as well as different oxygen concentration profiles in bulk Nb. In this work, we are trying to understand how do surface-processing methods and the resulting oxide/oxygen profiles affect the electronic structure of surface and the mechanism of superconductivity? With the help of Fermilab’s in-house X-ray photoemission facility and, in collaboration with the synchrotron-based angle-resolved photoemission (ARPES) facility at Argonne National Laboratory, we are investigating how the valence band structure and density of states (DoS) near the Fermi level modify with different surface treatments. Our observations show that different surface-processing methods lead to distinct evolutions of the valence-band states near the Fermi level during the superconducting transition. This behavior suggests variations in Nb-O orbital hybridizations and points towards the possibility of different underlying mechanisms of superconductivity governed by the surface chemistry and oxide configuration. We also correlate these distinct superconducting mechanisms with RF cavity performance, specifically focusing on measured surface resistance, the nature of the Q-slope, and quench fields observed in SRF measurements. These results will enable us to identify the potential limiting factors and relevant controllable parameters that can be further optimized to improve the performance of SRF cavities.

Tripathi, Malvika [Fermilab]

Design and Development of the PIP-II Stripline Beam Position Monitor

• Designed a stripline Beam Position Monitor (BPM) for the PIP-II accelerator to ensure precise proton beam alignment under ultra-high vacuum (UHV) conditions • Developed a mechanically robust and manufacturable assembly, including a cylindrical housing, electrodes, flange interfaces, and internal supports • Achieved high safety margins under pressure loading, using finite element analysis (FEA), while

Avalos Angel, Alejandro [Northern Illinois U.]

Deployable UHV Pump

This project presents an external motorized actuation system for a deployable ultra-high vacuum (UHV) pump, enabling internal motion without compromising vacuum conditions. All active components remain external due to environmental and space constraints. A motor-driven mechanical feedthrough transfers motion into the pump, supported by a modular, adjustable mounting system that maintains alignment and integrates with existing hardware. CAD modeling and iterative design were used to refine geometry and ensure proper fit. The final design reliably transfers motion while maintaining alignment and structural integrity. Its adjustability improves installation and maintenance, demonstrating a practical solution for actuation in UHV systems.

Remington, Austin [Northern Illinois U.]

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, Gianluigi [Thomas Jefferson National Acce

Correlating Surface Processing of Nb Superconducting RF Cavities with the Evolution of Surface Electronic States

Superconducting-radio frequency (RF) cavities provide an efficient way to accelerate particle beams with extremely high acceleration gradients while generating very small power dissipation. The few nanometers of the surface play a critical role in defining the RF performance of superconducting Nb based cavities. Over the past two decades, several pioneering surface treatment and processing methods have emerged, enabling remarkable improvements in superconducting cavity performance by simultaneously achieving high quality factors with increasing maximum acceleration gradients. These processing approaches include chemical polishing, distinct multi-step thermal treatments under ultra-high vacuum (UHV) conditions over low to high temperature regimes, as well as high-temperature treatments under controlled nitrogen atmospheres. Beyond their macroscopic impact on RF performance, these methods produce distinct surface oxide configurations characterized by different valence states, oxide thicknesses, chemical uniformity, and oxygen concentration profiles extending into the near-surface bulk of niobium. In this work, we are trying to understand how the surface-processing methods and the resulting oxide/oxygen profiles affect the electronic structure of surface and the mechanism of superconductivity. Using a combination of X-ray photoemission and X-ray absorption spectroscopies, we investigate how the valence-band structure and the electronic density of states (DoS) near the Fermi level evolve under different surface treatments. By employing tunable photon energies across multiple elemental absorption edges, we use resonant photoemission to disentangle and identify the elemental contributions to specific valence-band features. Our observations show that different surface-processing methods lead to distinct temperature evolutions of the DoS and valence-band states near the Fermi level. Our results suggest variations in different Nb-O orbital hybridizations in distinct processes and point towards the possibility of different underlying mechanisms of superconductivity governed by surface chemistry and oxide configuration. We also correlate these distinct superconducting mechanisms with RF cavity performance, specifically focusing on measured surface resistance, the nature of the Q-slope, and quench fields observed in superconducting RF measurements. These results will enable us to identify the potential limiting factors and relevant controllable parameters that can be further optimized to improve the performance of superconducting RF cavities.

Tripathi, Malvika [Fermilab] (ORCID:00000001989251

Design of Ionization Profile Monitors at the Integrable Optics Test Accelerator Facility at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm