Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “URANIUM ISOTOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Two-dimensional fluorescence spectroscopy of uranium isotopes in femtosecond laser ablation plumes

Here, we demonstrate measurement of uranium isotopes in femtosecond laser ablation plumes using two-dimensional fluorescence spectroscopy (2DFS). The high-resolution, tunable CW-laser spectroscopy technique clearly distinguishes atomic absorption from 235 U and 238 U in natural and highly enriched uranium metal samples. We present analysis of spectral resolution and analytical performance of 2DFS as a function of ambient pressure. Simultaneous measurement using time-resolved absorption spectroscopy provides information on temporal dynamics of the laser ablation plume and saturation behavior of fluorescence signals. The rapid, non-contact measurement is promising for in-field, standoff measurements of uranium enrichment for nuclear safety and security.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Image segmentation for uranium isotopic analysis by SIMS: Combined adaptive thresholding and marker controlled watershed approach

A novel approach to particle identification and particle isotope ratio determination has been developed for nuclear safeguard applications. This particle search approach combines an adaptive thresholding algorithm and marker-controlled watershed segmentation (MCWS) transform, which improves the secondary ion mass spectrometry (SIMS) isotopic analysis of uranium containing particle populations for nuclear safeguards applications. The Niblack assisted MCWS approach (a.k.a. SEEKER) developed for this work has improved the identification of isotopically unique uranium particles under conditions that have historically presented significant challenges for SIMS image data processing techniques. Particles obtained from five NIST uranium certified reference materials (CRM U129A, U015, U150, U500 and U850) were successfully identified in regions of SIMS image data 1) where a high variability in image intensity existed, 2) where particles were touching or were in close proximity to one another and/or 3) where the magnitude of ion signal for a given region was count limited. Analysis of the isotopic distributions of uranium containing particles identified by SEEKER showed four distinct, accurately identified 235U enrichment distributions, corresponding to the NIST certified 235U/238U isotope ratios for CRM U129A/U015 (not statistically differentiated), U150, U500 and U850. Additionally, comparison of the minor uranium isotope (234U, 235U and 236U) atom percent values verified that, even in the absence of high precision isotope ratio measurements, SEEKER could be used to segment isotopically unique uranium particles from SIMS image data. Although demonstrated specifically for SIMS analysis of uranium containing particles for nuclear safeguards, SEEKER has application in addressing a broad set of image processing challenges.

adaptive thresholding↗

Rate equation model of laser induced bias in uranium isotope ratios measured by resonance ionization mass spectrometry

Resonance Ionization Mass Spectrometry (RIMS) has been developed as a method to measure uranium isotope abundances. In this approach, RIMS is used as an element-selective ionization process between uranium atoms and potential isobars without the aid of chemical purification and separation. The use of broad bandwidth lasers with automated feedback control of wavelength was applied to the measurement of the U-235/U-238 ratio to decrease laser-induced isotopic fractionation. In application, isotope standards are used to identify and correct bias in measured isotope ratios, but understanding laser-induced bias from first-principles can improve the precision and accuracy of experimental measurements. A rate equation model for predicting the relative ionization probability has been developed to study the effect of variations in laser parameters on the measured isotope ratio. The model uses atomic data and empirical descriptions of laser performance to estimate the laser-induced bias expected in experimental measurements of the U-235/U-238 ratio. Empirical corrections are also included to account for ionization processes that are difficult to calculate from first principles with the available atomic data. Development of this model has highlighted several important considerations for properly interpreting experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncovering Uranium Isotopic Heterogeneity of Fuel Pellets from the Fifth Collaborative Materials Exercise of the Nuclear Forensics International Technical Working Group

In 2017, the Nuclear Forensics International Technical Working Group (ITWG) organized their fifth 37 Collaborative Materials Exercise (CMX-5). The exercise samples were two uranium dioxide fuel pellets 38 manufactured from the same starting materials by different processes to have similar bulk isotopic 39 composition, but different spatial uranium isotopic distributions. Sets of identical materials were sent to 40 all participating laboratories, who then utilized their existing nuclear forensic capabilities to 41 independently analyse fuel pellets and identify similarities and differences of the materials’ 42 characteristics. The analytical methods used to probe the fuel pellets included ex situ, such as sectioning 43 or breaking up the pellets and analyzing dissolved pieces using inductively coupled plasma mass 44 spectrometry (ICP-MS), analyzing particles collected from intact or fragmented pellets by secondary ion 45 mass spectrometry (SIMS), as well as in situ methods, such as laser ablation coupled with ICP-MS, 46 autoradiography and nanoSIMS. In this paper we present the results of these independent analyses and 47 compare the capabilities of those nuclear forensic analytical methods to uncover details of the isotopic 48 heterogeneity of uranium fuel pellets.

Nuclear Forensic Analysis of Uranium Fuel Pellets,↗

Certification of Uranium Isotope Amount Ratios in a Suite of Uranium Ore Concentrate Certified Reference Materials

Here, in this study, data from thirteen laboratories from around the world are presented for a successful certification of uranium isotope ratios in uranium ore concentrate (UOC) certified reference materials from the National Research Council Canada. Different mass spectrometric measurement principles (including SF-ICP-MS, quadruple ICP-MS, TIMS, MC-ICP-MS, SIMS and AMS) and measurement procedures were employed. In general, data from all sources exhibit good consistency with TIMS and MC-ICP-MS showing superior performance. The three candidate UOC CRMs (UCLO-1, UCHI-1 and UPER-1) have natural uranium isotope ratios with certified values of 0.5304(7) x 10 -4 , 0.5475(2) x 10 -4 and 0.5361(4) x 10 -4 for n( 234 U)/n( 238 U) and 0.007 2563(13), 0.007 2563(10) and 0.007 2542(11) for n( 235 U)/n( 238 U), respectively, with expanded uncertainty (k = 2) applicable to the last digit of the value given in the parentheses. Information values for n( 236 U)/n( 238 U) in these three CRMs, measured by AMS, are also provided: 10 x 10 -12 , 200 x 10 -12 and 22 x 10 -12 . The uncertainties of the proposed certified values of uranium isotope ratios in UOC CRMs are superior to available reference materials, and the values of n( 234 U)/n( 238 U) and n( 236 U)/n( 238 U) show significant variation among the three CRMs.

58 GEOSCIENCES↗

Application of ATONA Amplifiers to the Measurement of Uranium Isotopic Ratios by Thermal Ionization Mass Spectrometry

Uranium isotopic composition can provide valuable information about the history and provenance of a nuclear material; therefore, uranium isotopic analyses are frequently made in the nuclear forensics, safeguards, and environmental monitoring communities. These measurements have always presented challenges due to the extreme variability in the relative abundance between the major ( 235 U, 238 U) and minor ( 233 U, 234 U, 236 U) isotopes of uranium. Here, the recently developed ATONA (Atto- to Nano-Amp) amplification system paired with Faraday cup detectors has a large dynamic range and low noise floor making it ideal for measuring uranium isotopic ratios in materials of both natural and anthropogenic origin. A wide variety of certified reference materials were analyzed to investigate the utility of the ATONA amplification system for determining uranium isotopic composition in samples ranging from depleted to highly enriched. The ATONA amplifiers provide nearly an order of magnitude improvement in external reproducibility over 10 11 Ω amplifiers when measuring the minor 234 U/ 238 U ratio in isotopically natural and depleted samples and when paired with a secondary electron multiplier can measure very low relative abundance uranium isotopes (i.e., 236 U).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical characterization of laser induced plasmas towards uranium isotopic analysis in gaseous uranium hexafluoride

To perform direct enrichment assay on gaseous uranium hexafluoride (UF 6 ) with laser induced breakdown spectroscopy (LIBS), the dominant spectral-line features, evolution of the signal and background of the U II 424.437 nm line, and its Stark width and shift, were studied as a function of UF 6 gas pressure and pulse energy of a nanosecond Nd:YAG laser. In this work, vapor pressure of UF 6 was found to be the most important parameter for LIBS analysis of gaseous UF 6 . Spectral congestion with numerous U lines of high excitation potential was observed and signal-to-background ratio (SBR) was low for measurements with 80 Torr UF 6 . Only when both UF 6 vapor pressure and laser pulse energy were low, for example, less than 20 Torr pressure and 30 mJ pulse energy, the resultant LIBS spectra from gaseous UF 6 resembled those obtained from solid U samples. The experimental data also suggest that U and F atoms recombine back to UF 6 after the laser pulse. The U emission was found to decay fast with a persistent background signal, degrading SBR with delay time. Systematic positive biases were found for UF 6 enrichment assays performed with the 235 U– 238 U line pair at 424.412–424.437 nm, which was confirmed to be caused by self-absorption. Even with optimization of experimental parameters and incorporation of a self-absorption term into the spectral-fitting algorithm, to reduce and compensate for self-absorption, self-absorption is still a main factor limiting accurate UF 6 enrichment assay. The use of another spectral window which contains no resonance lines is a prospective solution for the self-absorption issue.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ATONA TE-TIMS of minor uranium isotopes (FY25 Mid-Year Report)

Isotopic measurements of the minor isotopes of uranium ( 233 U, 234 U, 236 U) are indispensable measures for material accountability and processing history but can be particularly challenging to accurately measure due to the very low abundance of the minor isotopes relative to 238 U, or 235 U in the case of highly enriched uranium (HEU). The goal of this project is to quantify detection limits for minor uranium isotope species at environmental levels (e.g 236 U/ 238 U < 10 -7 ) utilizing an ATONA-outfitted instrument and the Total Evaporation Thermal Ionization Mass Spectrometry (TE-TIMS) method. In the first half of Fiscal Year 2025, we set out to identify a suitable experimental material (Task 1) and to optimize our TE-TIMS measurement routine (Task 2). We have successfully identified a material and are in the process of getting an aliquot shipped to LANL. Simultaneously, we began working on our measurement routine utilizing CRM 112A. The results of each task are discussed in detail below.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS

The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (~8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO 3 ). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ~50 pg of 238 U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major ( 235 U/ 238 U) and minor ( 234 U/ 238 U and 236 U/ 238 U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gamma spectrometry uranium isotopic analysis rodeo: Summary of GADRAS results

This report summarizes GADRAS methods and gamma spectrometry rodeo uranium isotopic analysis results for high energy resolution H3D M400 cadmium zinc telluride (CZT) and ORTEC Micro Detective high-purity germanium (HPGe) spectra of uranium isotopic standards collected at Oak Ridge National Laboratory (ORNL) and Lawrence Livermore National Laboratory (LLNL) over a two-year measurement campaign. During the campaign, measurements were performed with the detectors unshielded, side shielded, and collimated. In addition, measurements of the uranium isotopic standards were performed unshielded and shielded.

07 ISOTOPE AND RADIATION SOURCES↗

Infrared spectroscopic method for uranium isotopic analysis

A high performance infrared (HPIR) system was developed and demonstrated for the infrared absorption analysis of {sup 235}U and {sup 238}U isotopes in uranium hexafluoride gas samples. Sweeping the quantum cascade laser light source over the spectral range and sampling via a high-rate analog-to-digital converter provided 0.0005 cm-1 spectral resolution, which allowed for high-precision measurements of the isotopic peak shift. A data analysis method was developed using principal component analysis to predict the isotope weight % content of {sup 235}U. The HPIR precision, accuracy, and error were evaluated for a wide range of isotopic ratio samples (0.287 – 93.7 weight % {sup 235}U), and the results were compared to the International Target Values (ITVS) set forth by the International Atomic Energy Agency (IAEA) for non-destructive and destructive analytical techniques. The method meets or surpasses the IAEA ITVs for non-destructive analysis of samples with isotopic content of depleted to highly enriched. The results also demonstrated the capability of the HPIR system to correctly predict the {sup 235}U weight % content of a mislabeled sample whose isotopic distribution was validated by mass spectroscopic measurements. The HPIR measurement is nondestructive and, thus, allows for confirmatory analyses of the exact sample at a designated IAEA lab if higher-resolution or a certified analysis is needed. (author)

07 ISOTOPE AND RADIATION SOURCES↗

Scoping Study: Highly Enriched Uranium Isotopic Assessments Using Gamma Spectroscopy Relative Efficiency Analysis When No Uranium-232 Is Present

This report documents results for a scoping study evaluating the viability of using the higher energy, low yield U-235 gamma emission at 345.9 keV to link low energy U-235 emissions to high energy U-238 emissions (rather than U-232 decay products gamma emissions) for highly enriched uranium isotopic gamma spectroscopy relative efficiency assessments when no or little U-232 is present and the U-235 signal is strong.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental and Theoretical Understanding of Neutron Capture on Uranium Isotopes

Neutron capture cross sections on uranium isotopes are important quantities needed to model nuclear explosion performance, nuclear reactor design, nuclear test diagnostics, and nuclear forensics. It has been difficult to calculate capture accurately, and factors of 2 or more be- tween calculation and measurements are not uncommon, although normalization to measurements of the average capture width and nuclear level density can improve the result. The calculations of capture for 233,235,237,239 U are further complicated by the need to accurately include the fission channel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)↗

Accurate determination of uranium isotope abundances by wavelength modulation spectroscopy in atomic beams

The design and demonstration of an optical analysis system based on wavelength modulation spectroscopy in an atomic beam for uranium isotope abundance determinations is presented. This system probes the uranium 5f 3 6d7s 2 ( 5 L 6 ) → 5f 2 6d 2 7s 2 ( 5 K 5 ) transition at 861.031 nm, which is considered to be the most suitable transition for uranium isotopic analysis. A new laser characterization strategy was developed for the conditions where optimum laser wavelength modulation depth was small compared to the free spectral range (FSR) of etalons. Two capabilities enabled the higher-precision determination of isotope abundances of atomic beams: (1) reduction of low-frequency additive noise, especially the noise caused by black-body radiation and (2) suppression of non-absorption transmission losses. The performance of this system was validated with uranium samples of various isotopic compositions. Further, by comparing the measurements using natural uranium samples between the direct absorption and the wavelength modulation approaches, a 21-fold decrease in uncertainty of the integrated absorbance and a 6.8-fold improvement in the 1-σ precision of the number density were achieved. In addition, by comparing the results using uranium oxide samples, a 6.1-fold decrease in the uncertainty of inferred isotope abundance was obtained. These results demonstrate that the 1f-normalized 2f wavelength modulation spectroscopy (WMS-2f/1f) technique enables higher-precision analysis of atomic beams.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Polyatomic interferences on high precision uranium isotope ratio measurements by MC-ICP-MS: Applications to environmental sampling for nuclear safeguards

Modern mass spectrometry and separation techniques have made measurement of major uranium isotope ratios a routine task; however accurate and precise measurement of the minor uranium isotopes remains a challenge as sample size decreases. One particular challenge is the presence of isobaric interferences and their impact on the accuracy of minor isotope 234 U and 236 U measurements. Furthermore, we present techniques used for routine U isotopic analysis of environmental nuclear safeguards samples and evaluate polyatomic interferences that negatively impact accuracy as well as methods to mitigate their impacts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗