Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “URANIUM HEXAFLUORIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation of an r-f radiant energy source with uranium hexafluoride and tungsten hexafluoride injection.

An experimental investigation was conducted using the UARL 1.2-megw r-f induction heater to simulate thermal environment and fuel region characteristics expected in nuclear light bulb reactors. Argon was injected at the ends of the test chamber to provide radial-inflow vortex flow pattern. In some tests, simulated fuel consisting of a mixture of argon gas with either tungsten hexafluoride gas, uranium hexafluoride gas, or tungsten particles was injected into the discharge region from probes located at the centers of the end walls. The encouraging initial results obtained are discussed.

Roman, W. C.↗

Single-Use Destructive Assay for Uranium Hexafluoride Sampling

Sampling uranium hexafluoride (UF6) for the determination of enrichments by destructive analysis (DA) is a critical component in the International Atomic Energy Agency’s layered safeguards approach for uranium processing facilities. Typically, gram-quantity UF6 samples are collected during inspections and stored under tag-and-seal until transportation to an off-site analytical laboratory. The shipping times can be long, and evolving restrictions on radioactive/corrosive materials shipments may increasingly limit the IAEA’s ability to transport UF6 samples easily. Pacific Northwest National Laboratory has developed a low-cost UF6 sampling technology called Single-Use Destructive Assay (SUDA) that addresses these challenges, as well as provides DA sample geometries that can be tailored for different analytical methods, including potential on-site analyses. The SUDA samplers, along with a unique holder, are designed for direct attachment to existing taps at uranium processing facilities, allowing gaseous UF6 to come into direct contact with a zeolite film. The SUDA technology features the ability to capture uranium in a more easily shipped and handled form as the solid, more stable, and relatively less hazardous hydrated uranyl fluoride (UO2F2•nH2O), which is formed through the controlled hydrolysis of UF6. We have recently simulated uranium collection under enrichment plant sampling conditions to further improve our understanding of SUDA sampling. Presented here is our recent work on measuring the relationship between sampling conditions and uranium collection, which includes control of the uranium-mass-to-zeolite ratio and assessing variable UF6 gas and sampling parameters that can affect collection using the SUDA sampler.

Pope, Timothy R.↗

Online monitoring the hydrolysis of uranium hexafluoride for intermediates by cryogenic layering and FTIR

Uranium hexafluoride (UF 6 ) is a commonly utilized material feedstock in uranium enrichment processes due to its high vapor pressure and ease of sublimation. When exposed to air, UF 6 undergoes spontaneous hydrolysis to form uranyl fluoride (UO 2 F 2 ) particulates which are utilized for the detection of undeclared nuclear activities by nuclear safeguards organizations. In this study, the kinetics of the hydrolysis reaction and how they relate to particle morphology of the product are still debated in the literature. Here, we report the direct, in situ observation of UF 6 reaction intermediates by cooling the reaction to cryogenic temperatures to significantly reduce the rate of hydrolysis. The reaction is then observable by Fourier transform infrared (FTIR) spectroscopy. The conversion of UF 6 to UOF 4 is observed as well as several other bands associated with possible long lived intermediate complexes. Chemometrics are used to further elucidate the reaction pathway from UF 6 to UO 2 F 2 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analytical characterization of laser induced plasmas towards uranium isotopic analysis in gaseous uranium hexafluoride

To perform direct enrichment assay on gaseous uranium hexafluoride (UF 6 ) with laser induced breakdown spectroscopy (LIBS), the dominant spectral-line features, evolution of the signal and background of the U II 424.437 nm line, and its Stark width and shift, were studied as a function of UF 6 gas pressure and pulse energy of a nanosecond Nd:YAG laser. In this work, vapor pressure of UF 6 was found to be the most important parameter for LIBS analysis of gaseous UF 6 . Spectral congestion with numerous U lines of high excitation potential was observed and signal-to-background ratio (SBR) was low for measurements with 80 Torr UF 6 . Only when both UF 6 vapor pressure and laser pulse energy were low, for example, less than 20 Torr pressure and 30 mJ pulse energy, the resultant LIBS spectra from gaseous UF 6 resembled those obtained from solid U samples. The experimental data also suggest that U and F atoms recombine back to UF 6 after the laser pulse. The U emission was found to decay fast with a persistent background signal, degrading SBR with delay time. Systematic positive biases were found for UF 6 enrichment assays performed with the 235 U– 238 U line pair at 424.412–424.437 nm, which was confirmed to be caused by self-absorption. Even with optimization of experimental parameters and incorporation of a self-absorption term into the spectral-fitting algorithm, to reduce and compensate for self-absorption, self-absorption is still a main factor limiting accurate UF 6 enrichment assay. The use of another spectral window which contains no resonance lines is a prospective solution for the self-absorption issue.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A theoretical investigation of the hydrolysis of uranium hexafluoride: the initiation mechanism and vibrational spectroscopy

Depleted uranium hexafluoride (UF 6 ), a stockpiled byproduct of the nuclear fuel cycle, reacts readily with atmospheric humidity, but the mechanism is poorly understood. Here we compare several potential initiation steps at a consistent level of theory, generating underlying structures and vibrational modes using hybrid density functional theory (DFT) and computing relative energies of stationary points with double-hybrid (DH) DFT. A benchmark comparison is performed to assess the quality of DH-DFT data using reference energy differences obtained using a complete-basis-limit coupled-cluster (CC) composite method. The associated large-basis CC computations were enabled by a new general-purpose pseudopotential capability implemented as part of this work. Dispersion-corrected parameter-free DH-DFT methods, namely PBE0-DH-D3(BJ) and PBE-QIDH-D3(BJ), provided mean unsigned errors within chemical accuracy (1 kcal mol -1 ) for a set of barrier heights corresponding to the most energetically favorable initiation steps. The hydrolysis mechanism is found to proceed via intermolecular hydrogen transfer within van der Waals complexes involving UF 6 , UF 5 OH, and UOF 4 , in agreement with previous studies, followed by the formation of a previously unappreciated dihydroxide intermediate, UF 4 (OH) 2 . The dihydroxide is predicted to form under both kinetic and thermodynamic control, and, unlike the alternate pathway leading to the UO 2 F 2 monomer, its reaction energy is exothermic, in agreement with observation. Finally, harmonic and anharmonic vibrational simulations are performed to reinterpret literature infrared spectroscopy in light of this newly identified species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Field Alpha Spectrometry to Assess Uranium Enrichment In Uranium Hexafluoride

A new In-Field Alpha Spectrometry (IFAS) system is being developed to allow quick turnaround measurements of uranium enrichment in uranium hexafluoride samples. Samples are collected using specially-designed Single-Use Destructive Assay (SUDA) wafers which have an absorptive thin film of zeolite deposited onto a quartz substrate. The SUDA samples, along with a special holder, are designed to be attached directly to a sampling tap at a gas centrifuge enrichment plant or a uranium conversion facility, allowing gaseous UF6 to come into direct contact with the zeolite. The zeolite absorbs this material and converts it into stable, safe UO2F2 within a few minutes. Once the sample has been collected it is transferred to the IFAS system where a solid-state, silicon alpha spectrometer is used to quantitatively measure the alpha emissions from 234U, 235U, and 238U form the sample. The SUDA samples are designed so that thin-film spectra are produced, and the SUDA samples and IFAS system are designed so that a complete measurement, with a final 235U:Utotal determination of <±2%, can be made in less than eight hours. This short time frame will allow an inspector to get results on-site within one working shift.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

In-Field Alpha Spectrometry to Assess Uranium Enrichment In Uranium Hexafluoride

A new In-Field Alpha Spectrometry (IFAS) system is being developed to allow quick turnaround measurements of uranium enrichment in uranium hexafluoride (UF6) samples. Samples are collected using specially-designed Single-Use Destructive Assay (SUDA) wafers which have an absorptive film of zeolite deposited onto a quartz or metal substrate. The SUDA samples, along with a special holder, are designed to be attached directly to a sampling tap at a gas centrifuge enrichment plant or a uranium conversion facility, allowing gaseous UF6 to come into direct contact with the zeolite. The zeolite absorbs this material and converts it into stable, safe UO2F2 within a few minutes. Once the sample has been collected it is transferred to the IFAS system where a solid-state, silicon alpha spectrometer is used to quantitatively measure the alpha emissions from 234U, 235U, and 238U in the sample. The IFAS system is a small, light-weight device that can be quickly turned on and put into use. The SUDA samples and IFAS hardware are designed so that thin-film spectra are produced, allowing a complete measurement with a final 235U:Utotal determination having a precision <±2% to be made in less than eight hours. This short time frame will allow an inspector to get results on-site within one working shift; further innovations may reduce this to even shorter times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal impacts on nondestructive analysis measurements of uranium hexafluoride

A series of nondestructive assay measurements were performed before, during, and after localized heating of an industrial standard 12B cylinder of uranium hexafluoride to replicate dose variations previously observed on commercial 30B cylinders. While cylinders represent a closed system, enrichment measurements may be impacted by altered uranium and daughter product distributions due to sublimation. A series of measurements were performed to examine localized heating impacts on dose rates, ratios of uranium and daughter product distributions, and measured 235 U enrichment as calculated by two different approaches. The less complex enrichment meter approaches were found to be more robust and less prone to deviation than isotope ratio approaches such as FRAM, but the impact can be minimized by using observable dose changes to avoid impacted areas.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spectral emission characteristics near 646 nm and plasma properties of laser-induced plasma of gaseous uranium hexafluoride

We present a detailed investigation of the temporal evolution of line and continuum emissions in laser-induced breakdown spectroscopy (LIBS) of gaseous uranium hexafluoride (UF 6 ), focusing on the spectral region near 646 nm. Spectral emission features, signal-to-background ratios (SBRs) of selected uranium lines, and spectral linewidths were examined under varying UF 6 pressures (15–60 Torr) and laser pulse energies (10–60 mJ). Higher pressures and pulse energies enhanced continuum emission and reduced SBRs but did not cause significant spectral congestion. Additional studies with the use of different laser systems, including nanosecond-pulsed Nd:YAG lasers (at fundamental and various harmonics) and a femtosecond-pulsed Ti:sapphire laser, revealed long-lived plasma continua in all cases. This persistent continuum is attributed to a pseudo-continuum from overlapping molecular emissions, as its intensity scales linearly with electron number density, deviating from the expected quadratic dependence of classical ion–electron interactions for free-free and free-bound continuum emission. Based on plasma persistence time, SBR, U II/U I intensity ratios, and electronic excitation temperature, no fundamental advantage was found for femtosecond-pulsed lasers over conventional nanosecond-pulsed ones for UF 6 enrichment assay with direct LIBS measurement.

Laser-induced breakdown spectroscopy↗

Gamma-ray spectrum variations for surface measurements of uranium hexafluoride cylinders

Here, this work aims to characterize features that contribute to the spectral variations that appear in gamma-23 ray spectra of filled uranium hexafluoride (UF 6 ) cylinders. While the enrichment of the UF 6 in a 24 cylinder can greatly affect gamma-ray spectra at peaks such as the 185.7 keV peak and be used to 25 verify enrichment, many other characteristics of a filled UF 6 cylinder can affect the spectra. These 26 characteristics vary on a per-cylinder basis and can include: the time between when a cylinder was 27 filled and when it was measured; the previous fill history of a cylinder; how the cylinder was most 28 recently filled; the UF 6 geometric distribution within the cylinder; and the measurement location 29 along the cylinder. This work explores spectral variations seen in measurement data and uses 30 validated simulation models to find trends in these uncertainties. These trends are analyzed to observe 31 how each parameter can contribute to the overall uncertainty of UF 6 spectral measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and Optimization of a Spectral Window for Direct Gaseous Uranium Hexafluoride Enrichment Assay Using Laser-Induced Breakdown Spectroscopy

Through a systematic scanning of 235 U and 238 U emission lines between 280 nm and 745 nm, the optimal emission line for direct gaseous uranium hexafluoride (UF 6 ) enrichment assay using laser-induced breakdown spectroscopy (LIBS) was found. Screening for spectral features that are potentially useful for U isotopic analysis was gauged from the magnitude of the 235 U– 238 U isotopic shift and the signal-to-background ratio of the emission line through a parameter termed ΔSBR 235U–238U . The ΔSBR spectrum shows peaks at wavelength positions where there are strong lines with significant 235 U– 238 U shifts. The screening identified 13 spectral-window candidates, which were down selected based on their overall accuracy in predicting the 235 U enrichment of three UF 6 samples of natural (0.720 atom% 235 U) and low-enriched (4.675 atom% and 9.157 atom% 235 U) grades. The U(I) 646.498 nm emission line, with a determined 235 U– 238 U isotopic shift of -17.7 pm, was found to be the optimal spectral window for direct UF 6 enrichment assay. The root mean square error for enrichment assays on the three natural and low-enriched UF 6 samples, with each sample measured in six replicates, was 0.31% in absolute 235 U content. Each measurement comprised LIBS signals accumulated from 3000 laser shots. In conclusion, the analytical bias and precision were better than 0.5% and 0.3%, respectively, in absolute [ 235 U/( 235 U + 238 U)] ratios. Specific for the two low-enriched UF 6 samples, the relative standard deviations from six replicated measurements were around 2%.

47 OTHER INSTRUMENTATION↗

Parametric analyses of planned flowing uranium hexafluoride critical experiments

Analytical investigations were conducted to determine preliminary design and operating characteristics of flowing uranium hexafluoride (UF6) gaseous nuclear reactor experiments in which a hybrid core configuration comprised of UF6 gas and a region of solid fuel will be employed. The investigations are part of a planned program to perform a series of experiments of increasing performance, culminating in an approximately 5 MW fissioning uranium plasma experiment. A preliminary design is described for an argon buffer gas confined, UF6 flow loop system for future use in flowing critical experiments. Initial calculations to estimate the operating characteristics of the gaseous fissioning UF6 in a confined flow test at a pressure of 4 atm, indicate temperature increases of approximately 100 and 1000 K in the UF6 may be obtained for total test power levels of 100 kW and 1 MW for test times of 320 and 32 sec, respectively.

Rodgers, R. J.↗

Studies of Helium Behavior in Uranium Hexafluoride

Several issues have arisen from experimental observations and/or theoretical postulation related to the behavior of helium in uranium hexafluoride (UF 6 ) matrices and how it may impact the ability to use this noble gas to quantify the fill date of the cylinder. A series of experiments was conducted to address several such issues, and the results and implications are reported here. Two issues relate to bias in the helium measurement due to ambient air from extraneous sources such as atmospheric air or from potential holdup in a large, activated alumina chemical trap. These issues are really a question of differential retention of helium versus three other inert gas isotopes (representative of other noble gases found in air) used as a calibration for air in leakage. Discernable bias was not detected in either case. Another issue had to do with helium potentially brought into the cylinder by a liquid UF 6 fill and subsequently released as the material solidifies and/or during storage. The solubility of helium in liquid UF 6 was measured to investigate this theory. The experiment quantified the potential magnitude of the initial helium contribution if present. The final issue was that of retention of helium in solid UF 6 . Investigation of this theory necessitated quantifying both the solubility and the diffusivity of helium in UF 6 . In one experiment, the solubility was measured at cryogenic temperature, allowing quantification of helium in solid UF 6 such as would be found in a cold trap. In a second experiment, transport of helium into and through a macroscopic plug of solid UF 6 was examined. The transport was very slight although apparently detectible. Effectively, only an upper limit to the transport could be determined, but that limit implied that helium holdup in solid UF 6 is a real possibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uranium Hexafluoride Hydrolysis Reaction Dynamics from Cryogenic Layering, FTIR Spectroscopy, and Isotopic Substitution

The first direct evidence that the hydrolysis reaction of uranium hexafluoride (UF 6 ) follows multiple competing pathways which are driven by the ratio of water to UF 6 , temperature, and isotopic composition is presented. Using temperature dependent infrared spectroscopy, it is shown the hydrolysis can be prevented at temperatures below 150 K, and that water-rich environments promote the formation of uranium oxyfluoride intermediates. Spectral shifts reveal isomeric transitions and the growth of polymeric species, with reaction reversibility observed at high water concentrations. Additionally, controlled heating rates affect the emergence of intermediates. The final particulate product consistently forms as uranyl fluoride hydrate, though its morphology and spectral signature vary with reaction conditions and annealing. These findings help clarify long-standing uncertainties surrounding UF 6 hydrolysis.

Chemical reactions↗

Optimization Of In-field Alpha Spectrometry For Uranium Enrichment Determination In Uranium Hexafluoride

In response to needs identified by the International Atomic Energy Agency (IAEA) research is underway to develop In-Field Alpha Spectrometry (IFAS) as a method to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF6) at processing facilities to assess and verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (as a dihydrate, UO2F2&middot;2H2O). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the past year optimization work has significantly increased the diameter of useful SUDA samples (from 12.7 mm to 48 mm), improved the manufacturability and reproducibility of SUDA samples, increased the area of the IFAS alpha spectrometer sensor from 1.2 cm to 3.1 cm, and improved source positioning within the IFAS. This paper will report on this optimization work, its impacts on IFAS performance, and future plans for IFAS miniaturization, improvements, and testing.

Chichester, David↗

Optimization of In-Field Alpha Spectrometry for Uranium Enrichment Determination in Uranium Hexafluoride

In response to needs identified by the International Atomic Energy Agency (IAEA) research is underway to develop In-Field Alpha Spectrometry (IFAS) as a method to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF6) at processing facilities to assess and verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (UO2F2). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the past year optimization work has significantly increased the diameter of useful SUDA samples (from 12.7 mm to 48 mm), improved the manufacturability and reproducibility of SUDA samples, increased the area of the IFAS alpha spectrometer sensor from 1.2 cm to 3.1 cm, and improved source positioning within the IFAS. This paper will report on this optimization work, its impacts on IFAS performance, and future plans for IFAS miniaturization, improvements, and testing.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗