Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “U(CuP)2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Materials Data on U(CuP)2 by Materials Project

UCu2P2 crystallizes in the trigonal P-3m1 space group. The structure is three-dimensional. U4+ is bonded to six equivalent P3- atoms to form UP6 octahedra that share corners with twelve equivalent CuP4 tetrahedra, edges with six equivalent UP6 octahedra, and edges with six equivalent CuP4 tetrahedra. All U–P bond lengths are 2.77 Å. Cu1+ is bonded to four equivalent P3- atoms to form CuP4 tetrahedra that share corners with six equivalent UP6 octahedra, corners with six equivalent CuP4 tetrahedra, edges with three equivalent UP6 octahedra, and edges with three equivalent CuP4 tetrahedra. The corner-sharing octahedra tilt angles range from 19–54°. There are three shorter (2.35 Å) and one longer (2.40 Å) Cu–P bond lengths. P3- is bonded to three equivalent U4+ and four equivalent Cu1+ atoms to form a mixture of distorted edge and corner-sharing PU3Cu4 pentagonal bipyramids.

36 MATERIALS SCIENCE↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

Factors controlling precision and accuracy in isotope-ratio-monitoring mass spectrometry

The performance of systems in which picomole quantities of sample are mixed with a carrier gas and passed through an isotope-ratio mass spectrometer system was examined experimentally and theoretically. Two different mass spectrometers were used, both having electron-impact ion sources and Faraday cup collector systems. One had an accelerating potential of 10kV and accepted 0.2 mL of He/min, producing, under those conditions, a maximum efficiency of 1 CO2 molecular ion collected per 700 molecules introduced. Comparable figures for the second instrument were 3 kV, 0.5 mL of He/min, and 14000 molecules/ion. Signal pathways were adjusted so that response times were <200 ms. Sample-related ion currents appeared as peaks with widths of 3-30 s. Isotope ratios were determined by comparison to signals produced by standard gases. In spite of rapid variations in signals, observed levels of performance were within a factor of 2 of shot-noise limits. For the 10-kV instrument, sample requirements for standard deviations of 0.1 and 0.5% were 45 and 1.7 pmol, respectively. Comparable requirements for the 3-kV instrument were 900 and 36 pmol. Drifts in instrumental characteristics were adequately neutralized when standards were observed at 20-min intervals. For the 10-kV instrument, computed isotopic compositions were independent of sample size and signal strength over the ranges examined. Nonlinearities of <0.04%/V were observed for the 3-kV system. Procedures for observation and subtraction of background ion currents were examined experimentally and theoretically. For sample/ background ratios varying from >10 to 0.3, precision is expected and observed to decrease approximately 2-fold and to depend only weakly on the precision with which background ion currents have been measured.

NASA Discipline Exobiology↗

Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source

The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, many dark matter models predict an energy spectrum which rises quasi-exponentially with decreasing energy transfer to a target atom. LZ expects to detect coherent neutrino-nucleus scattering of $^{8}$B solar neutrinos, the signal from which is very similar to a dark matter particle with mass of about 5.5 GeV/$c^{2}$, which result in typical nuclear recoil energies of $<$5 keV$_{\text{nr}}$. Therefore, it is of crucial importance to calibrate the response of recoiling xenon nuclei to keV-energy recoils. This analysis details the first in situ photoneutron calibration of the LZ detector and probes its response in this energy regime.

Aalbers, J. [SLAC; Stanford U., Phys. Dept.; KIPAC↗