Validation of the Public Radiation Exposure Calculation for the Incident at the National Institute of Standards and Technology Center for Neutron Research on February 3, 2021

The Department of Energy/National Nuclear Security Administration Consequence Management Program was contacted by the Health Physics Chief of the National Institute of Standards and Technology Center for Neutron Research (NCNR) to review public radiation exposure calculations for an event that occurred on its Gaithersburg, Maryland, campus on February 3, 2021. Subject matter experts from the Nuclear Emergency Support Team (NEST) assets, specifically the Consequence Management Home Team (CMHT) and the National Atmospheric Release Advisory Center (NARAC), were selected to provide support. CMHT used three separate modeling codes to validate the results the scientists at NCNR calculated using the HotSpot model. The analyses were performed using NARAC’s in-house Lagrangian dispersion codes known as LODI and Aeolus, as well as the Turbo FRMAC software from Sandia National Laboratories. The team used parameters provided by the NCNR scientists regarding the site, applicable observable meteorological data, and environmental survey and sampling data to estimate public exposure. Each model estimated public dose at much less than 0.5 mrem. CMHT concurs with the NCNR public radiation exposure calculations which state that members of the public at the 400-meter boundary would have received a radiological dose of less than 0.5 mrem.

61 RADIATION PROTECTION AND DOSIMETRY↗

Transfer Factors for the FRMAC Assessment Manual and Turbo FRMAC to Improve Radiological Dose Assessment

The Turbo FRMAC analysis tool is used to perform complex calculations to quickly evaluate radiological consequences and aid in decision making during an emergency response by assessing impacts to the public, workers, and the food supply. Turbo FRMAC calculations are based on methods established by the Federal Radiological Monitoring and Assessment Center (FRMAC). To be able to assess impacts, input data called transfer factors that describe radionuclide uptake by local plants and animals are required. During the code application exercises in late 2016, identifying, finding, and validating nonstandard transfer factors proved to be time consuming and diverted the teams’ activity away from other critical tasks. As a result, a task was undertaken to dramatically expand the list of available transfer factors (food and non-food) and incorporate these factors into Turbo FRMAC. This will ultimately result in improved efficiency of the assessment team to perform calculations during times when the FRMAC is activated and provide more defensible, vetted data from which to calculate results. As a result of these and subsequent exercises, transfer factors were needed for the following items: bell peppers, Christmas tree, deer, flowers, fresh cucumbers, tomatoes, grapefruit, lichens, mushrooms, oranges, snap beans, squash, strawberries, sugarcane for sugar and seed, sweet corn, tea, tobacco, tree bark, and watermelon. To expand the applicability of the information tables, generic transfer data were also provided for common categories and recommendations were made for expanding the list of chemicals based on chemical similarity. The data presented in this report were compiled from recent literature with most of the data encompassing the period from 2000 to 2018. The following radionuclides were targeted during the literature search: elements associated with reactor accidents or nuclear detonations (Sr 89/90, Cs 134/137, Ce 141/144, Ru 103/106, I 129/131/133, Pu 238/239, Am 241, Zr 95, and Nb 95) and elements associated with industrial accidents or dirty bombs (Ir 192 and Co 60). Data from other elements were evaluated if they were identified during the literature search. In addition, reports were evaluated that were recommended by the research consultants. For each plant or animal transfer factor, the goal was to determine the geometric mean, the geometric standard deviation, the minimum, the maximum, and the number of measurements used. If only one measurement was available that was presented as the mean. Concentration ratios with large geometric standard deviations (GSDs) were generally the result of a paucity of measurements or a few disparate measurements. Measurement disparity was observed for data from different soil types. The geometric mean (GM) is a good reference value for planning and responses purposes, but the location-specific concentrations are unlikely to be similar to the model results. Recommendations for further work include: segregating the data to reflect the influence of soil type, developing approaches to incorporate animal data based on aggregated transfer measurements, and including data for foliar deposition on plants.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hydrodynamic Characteristics of Coolant Tracts in High-Temperature Gas-Cooled Nuclear Reactor

A validation of the hydrodynamic characteristics of the coolant loop of a high-temperature gas-cooled reactor at low power in a power-generating facility using a turbo-machine conversion in a Brayton cycle is given. The validation is accomplished using diagnostics of models of a coolant loop, numerical modeling of the hydrodynamics, heat-and-mass transfer in models with more accurate three-dimensional CFD codes. Relations for ensuring tangential uniformity of the coolant velocity distribution near the core shell and at the entry into the distributing manifold are obtained. A distributing manifold geometry securing a uniform coolant flow distribution over core cooling tracts at low hydraulic resistance is proposed. Data are obtained on the velocity and temperature distributions in fuel pins spaced by a wire winding.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization and Optimization of the Fitting of Quantum Correlation Functions

This case study presents a characterization and optimization of an application code for extracting parton distribution functions from high energy electron-proton scattering data. Profiling this application code reveals that the phase-space density computation accounts for 93% of the overall execution time for a single iteration on a single core. When executing multiple iterations in parallel on a multicore system, the application spends 78% of its overall execution time idling due to load imbalance. We address these issues by first transforming the application code from Python to C++ and then tackling the application load imbalance via a hybrid scheduling strategy that combines dynamic and static scheduling. These techniques result in a 62% reduction in CPU idle time and a 2.46x speedup in overall execution time per node. In addition, the typically enabled power-management mechanisms in supercomputers (e.g., AMD Turbo Core, Intel Turbo Boost, and RAPL) can significantly impact intra-node scalability when more than 50% of the CPU cores are used. This finding underscores the importance of understanding system interactions with power management, as they can adversely impact application performance, and highlights the necessity of intra-node scaling tests to identify performance degradation that inter-node scaling tests might otherwise overlook.

Chuang, Pi-Yueh [Virginia Tech,Dept. of Computer S↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

3D numerical simulation of the long range propagation of acoustical shock waves through a heterogeneous and moving medium

Many situations involve the propagation of acoustical shock waves through flows. Natural sources such as lightning, volcano explosions, or meteoroid atmospheric entries, emit loud, low frequency, and impulsive sound that is influenced by atmospheric wind and turbulence. The sonic boom produced by a supersonic aircraft and explosion noises are examples of intense anthropogenic sources in the atmosphere. The Buzz-Saw-Noise produced by turbo-engine fan blades rotating at supersonic speed also propagates in a fast flow within the engine nacelle. Simulating these situations is challenging, given the 3D nature of the problem, the long range propagation distances relative to the central wavelength, the strongly nonlinear behavior of shocks associated to a wide-band spectrum, and finally the key role of the flow motion. With this in view, the so-called FLHOWARD (acronym for FLow and Heterogeneous One-Way Approximation for Resolution of Diffraction) method is presented with three-dimensional applications. A scalar nonlinear wave equation is established in the framework of atmospheric applications, assuming weak heterogeneities and a slow wind. It takes into account diffraction, absorption and relaxation properties of the atmosphere, quadratic nonlinearities including weak shock waves, heterogeneities of the medium in sound speed and density, and presence of a flow (assuming a mean stratified wind and 3D turbulent ? flow fluctuations of smaller amplitude). This equation is solved in the framework of the one-way method. A split-step technique allows the splitting of the non-linear wave equation into simpler equations, each corresponding to a physical effect. Each sub-equation is solved using an analytical method if possible, and finite-differences otherwise. Nonlinear effects are solved in the time domain, and others in the frequency domain. Homogeneous diffraction is handled by means of the angular spectrum method. Ground is assumed perfectly flat and rigid. Due to the 3D aspect, the code was massively parallelized using the single program, multiple data paradigm with the Message Passing Interfaces (MPI) for distributed memory architectures. This allows us to handle problems in the order of a thousand billion mesh points in the four dimensions (3 dimensions of space plus time). The validity of the method has been thoroughly evaluated on many cases with known solutions: linear piston, scattering of plane wave by a heterogeneous sphere, propagation in a waveguide with a shear flow, scattering by a finite amplitude vortex and nonlinear propagation in a thermoviscous medium. This validation process allows for a detailed assessment of the advantages and limitations of the method. Finally, applications to atmospheric propagation of shock waves will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-JeP2-06: Dosimetric and Workflow Evaluation of First Commercial Synthetic CT Software for Clinical Use in Pelvis

Purpose: evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy Methods: Twenty prostate patients underwent CT and MR simulation scans in treatment position on a 3T Philips scanner. The MR protocol consisted of a T2w turbo spin-echo for soft tissue contrast, a 2D balanced-fast field echo (b-FFE) for fiducial identification, a dual-echo 3D FFE B0 map for distortion analysis and a 3D mDIXON FFE sequence to generate syn-CT. Two echoes are acquired during mDIXON scan, allowing water, fat, and in-phase images to be derived using the frequency shift of the fat and water protons. Tissues were classified as: air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned specific bulk HU values. Bone structures are segmented based on a pelvis bone atlas. Accuracy of syn-CT for patient treatment planning was analyzed by transferring the original plan and structures from the CT to syn-CT via rigid registration and recalculating dose. In addition, new IMRT plans were generated on the syn-CT using structures contoured on MR and transferred to the syn-CT. Accuracy of fiducial-based localization at the treatment machine performed using syn-CT or DRRs generated from syn-CT was assessed by comparing to orthogonal kV radiographs or CBCT. Results: Dosimetric comparison between CT and syn-CT was within 0.5% for all structures. The de-novo optimized plans generated on the syn-CT met our institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B0 maps was within 1mm and 0.4 mm in the body and prostate. The rectal and bladder outlines on the syn-CT were deemed sufficient for assessing rectal and bladder filling on the CBCT at the time of treatment. CBCT localization showed a median error of < ±1 mm in LR, AP and SI direction. Conclusion: MRI derived syn-CT can be used clinically in MR-alone planning and treatment process for prostate. Drs. Deasy, Hunt and Tyagi have Master research agreement with Philips healthcare.

60 APPLIED LIFE SCIENCES↗