Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Transmission Line”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A cost–benefit framework to evaluate capacity upgrade options in overhead line transmission planning

This paper presents the methodology behind the new Reconductoring Economic and Financial Analysis (REFA) tool, an open-access software, used by transmission utilities to evaluate transmission capacity enhancement options. The proposed methodology is intended to be used in a new planning stage, after the capacity expansion and prior to the individual transmission project engineering, allowing capacity upgrade options (reconductoring, rebuild or voltage upgrade), and respective conductor selection, to be compared under the same economic basis. Furthermore, the REFA tool implements a methodology to rank project options and conductor types based on economic criteria, considering an approximation of the ampacity and sag constraints. Results, using 5 real transmission lines in the US, show that least-cost combinations of project and conductor types can be very diverse, which emphasizes the need for the proposed methodology and tool.

Advanced conductors

Theory and simulation of gap distance transitions in planar magnetically insulated transmission lines

Magnetically insulated transmission lines (MITLs) are critical components for efficiently transporting power from pulsed power sources to a diverse range of loads, including magneto-inertial confinement fusion and radiation production. This study investigates the behavior of planar MITLs, taking into account the source voltage and source and load impedances, using two-dimensional theory and simulations. Self-limited behavior, where the MITL operating impedance (voltage divided by current) is insensitive to the value of load impedance, is extended to small-to-large gap distance MITL transitions. Load-limited behavior, in which the load impedance is below the self-limited impedance, causes the MITL operating impedance to adjust to match the load impedance and can be extended to describe large-to-small transitions. In both cases, the operating impedance of the larger MITL section changes to match the self-limited operating impedance of the smaller section. This behavior extends to multiple transitions and to both low and high impedance loads. Assuming equilibration occurs (pulse duration larger than MITL transit time), the entire MITL operating impedance becomes the self-limited impedance of the smallest-gap MITL section or the load impedance, whichever is lower.

Darr, Adam M. [Sandia National Laboratories (SNL-N

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays

Gyromagnetic nonlinear transmission line for radio frequency signal generation and pulse compression

Disclosed are non-linear transmission lines using ferromagnetic materials to generate ferromagnetic resonance oscillations. In one aspect, a non-linear transmission line apparatus is disclosed. The apparatus includes an outer conductor having a first side and a second internally facing side, and an inner conductor positioned internal to the non-linear transmission line apparatus. The apparatus further includes a ferromagnetic material surrounding the inner conductor, wherein the ferromagnetic material comprises nanoparticles of an ε-polymorph of iron oxide expressed as ε-Fe2O3. The apparatus also includes a first dielectric material positioned between the outer conductor and the inner conductor, the dielectric material in contact with both the ferromagnetic material and with the second internally facing side of the outer conductor, wherein the outer conductor, the inner conductor, the dielectric material and the ferromagnetic material form the nonlinear transmission line.

Schneider, Joseph Devin

Determining the Minimum Phase‐to‐Phase Gap Distance for Unconventional Transmission Lines Using Numerical Method

With the increasing demand for power transmission, compact, high surge impedance loading (HSIL) high-voltage transmission lines have emerged as a viable solution due to their reduced land acquisition costs and higher power delivery capability. The compactness of a transmission line depends on effective insulation coordination, particularly in determining the phase-to-phase clearance, which is governed by the critical flashover voltage under switching and lightning overvoltage conditions. Traditional methods for phase-to-phase clearance rely on empirical formulas derived from experimental data, which are convenient for conventional high-voltage lines. However, unconventional HSIL lines require a faster and more adaptable evaluation method, as they involve optimized conductor positioning to reduce right-of-way requirements while enhancing natural power loadability. This study presents a simplified numerical approach to determine the minimum phase-to-phase gap, utilizing arc propagation viability curves, and offers an efficient alternative to conventional empirical methods. The proposed method was successfully applied to a 500 kV conventional line as well as 500 and 735 kV unconventional line designs, demonstrating its capability in accurately assessing insulation requirements. Results reveal that the method can support reduced gap clearances while still maintaining reliability, thereby validating its usefulness in optimizing compact transmission line configurations.

Arafat, Easir [The University of Texas at Dallas,

Western Interconnect Transmission Line Wildfire Risk

The datasets contain wildfire risk probabilities for transmission lines in the Western Interconnect, identified only by the HIFLD dataset identifier. The dataset is generated using PNNL's WREST Tool (https://www.pnnl.gov/projects/wildfire-risk-resilience/tools/wrest). The input dataset includes HIFLD datasets on transmission lines and wildfire burn potentials and flame lengths from the PNNL RADR-FIRE Tool for 2025.

psps

Addendum to SAND2023-09604 Xyce lumped-element transmission line model verification to support Empire-Cable cable SGEMP analyses

This report supplements the Verification of Empire-Cable SAND report by expanding on the use of Xyce to simulate the coupling to a transmission line cable model. While Empire-Cable solves its governing equations on a high-order, finite-element mesh with an an implicit-in-time formulation, Xyce must use a first order graph for the circuit and explicit-in-time approach to be compatible with non-linear electrical device models. Thus, given the different solution methodologies in Xyce as compared to Empire-Cable, the convergence rates are expected to be different but the overall quality of the solution should be the same. The original four canonical problems studied in the Empire-Cable verification report are replicated here running in Xyce using transmission line modeling parameters from the verification report. Overall, agreement between the codes is excellent with Xyce’s convergence rates being limited mostly to first order due to the circuit network approximation of a transmission line being a first order approximation.

42 ENGINEERING

Studying the Impact of Momentary Cessation of IBRs Compliant With IEEE Std. 2800-2022 on Transmission Line Protection Elements

This paper examines the impact of inverter-based resource (IBR) momentary cessation timing on transmission system protection relays. IEEE Std. 2800 mandates voltage ride-through, requiring IBRs to remain online during voltage disturbances. However, for severe voltage dips (|V| = 0.1 p.u.), the standard permits current blocking. In practice, vendors implement momentary cessation with varying delays, potentially affecting relay operation if IBRs cease too early. This article studies the impact of the time IBRs enter momentary cessation on transmission line protective relays. Using an electromagnetic transient (EMT) simulation, this study models IBR momentary cessation with tunable delays in a realistic transmission network. COMTRADE files generated from EMT simulations are analyzed in MATLAB using detailed protective relay models. Results indicate that IBRs must sustain operation for at least one cycle to ensure proper relay response; otherwise, relays may fail to oper- ate. These findings guide IBR vendors in optimizing momentary cessation settings to enhance transmission line protection.

24 POWER TRANSMISSION AND DISTRIBUTION

Transmission Line Based Sensor Design for FMCW Radar Processing of Collision Damage

This report presents a framework for transmission line ( T-L ) sensor design in Frequency Modulated Continuous Wave (FMCW) radar applications, with particular emphasis on modeling collision damage effects. Classical electromagnetic (EM) propagation theory is combined with impact mechanics to develop a model for analyzing transmission line behavior as a sensor under high-velocity impact conditions. The framework includes detailed mathematical derivations, spatial and temporal damage evolution models, and practical implementation considerations.

42 ENGINEERING

Two-frequency RF fields induced multipactor in coaxial transmission lines

This study presents a comprehensive investigation of two-surface multipactor discharge in coaxial transmission lines under two-frequency radio frequency (RF) excitation using one-dimensional Monte Carlo simulations validated against three-dimensional particle-in-cell simulations and experimental data. The results show that introducing a second carrier mode can suppress multipactor by reshaping and shrinking the susceptibility region, with the extent and location of suppression strongly dependent on the device's aspect ratio and the relative phase of the second carrier mode. Distinct suppression patterns are observed across different fd regimes, while in some cases, susceptibility expansion also occurs under two-frequency operation. A key outcome is the identification and delineation of pure and mixed multipactor modes in coaxial geometry, where analytical mode boundaries are not readily available. Unlike planar geometries, pure-mode regions in coaxial systems overlap with mixed-mode domains, complicating mode identification. Additionally, image charge forces are found to have negligible influence on susceptibility thresholds but strongly affect electron growth rates. These findings offer valuable insights into the use of waveform engineering for controlling multipactor in high-power RF systems.

43 PARTICLE ACCELERATORS

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY

Nonlocal, diamagnetic electromagnetic effects in magnetically insulated transmission lines

We identify the time-dependent physics responsible for the critical reduction of current losses in magnetically insulated transmission lines (MITLs) due to uninsulated space charge-limited currents of electrons emitted by field stress. A drive current of sufficiently short pulse length introduces a strong enough time dependence that steady-state results alone become inadequate for the complete understanding of current losses. The time-dependent physics can be described as a nonlocal, diamagnetic electromagnetic response of space charge limited currents. As the pulse length is increased or equivalently, the MITL length reduced, these time-dependent effects diminish and current losses converge to those predicted by the well-known Child–Langmuir law in the external (vacuum) fields. We present a simple one-dimensional (1D) model that encapsulates the essence of this physics. We find excellent agreement with 2D particle-in-cell simulations for two MITL geometries, Cartesian parallel plate and azimuthally symmetric straight coaxial. Based on the 1D model, we explore various scaling dependencies of MITL losses with relevant parameters, e.g., peak current, pulse length, geometrical dimensions, etc. We propose an improved physics model of magnetic insulation in the form of a Hull curve, which could also help improve predictions of current losses by common circuit element codes, such as BERTHA. Finally, we describe how to calculate the temperature rise due to electron impact within the 1D model.

Computer simulation

Development of a Two-Dimensional CASTLE Transmission-Line Model for all Levels of Saturn

This report describes a two-dimensional model of Saturn based on the CASTLE transmission line code. Building on previous modeling efforts, 2D circuit models based on the “chain-link fence” geometry are constructed for pre-ReCap Saturn and post-ReCap Saturn. The 2D model results are in better agreement with data from Shot 4550 measurements of load currents and doses then the previous 1D model. Lower doses (9%) predicted by the new model can be compensated by increasing the load A-K gap.

43 PARTICLE ACCELERATORS

Dynamic Transmission Line Switching Amid Wildfire-Prone Weather Under Decision-Dependent Uncertainty

During dry and windy seasons, environmental conditions significantly increase the risk of wildfires, exposing power grids to disruptions caused by transmission line failures. Wildfire propagation exacerbates grid vulnerability, potentially leading to prolonged power outages. To address this challenge, we propose a multistage optimization model that dynamically adjusts transmission grid topology in response to wildfire propagation, aiming to develop an optimal response policy. By accounting for decision-dependent uncertainty, where line survival probabilities depend on usage, we employ distributionally robust optimization to model uncertainty in line survival distributions. We adapt the stochastic nested decomposition algorithm and derive a deterministic upper bound for its finite convergence. To enhance computational efficiency, we exploit the Lagrangian dual problem structure for a faster generation of Lagrangian cuts. Using realistic data from the California transmission grid, we demonstrate the superior performance of dynamic response policies against two-stage alternatives through a comprehensive case study. In addition, after solving the multistage formulation, we construct easy-to-implement policies that significantly reduce computational burden while maintaining good performance in real-time deployment. History: Accepted by Russell Bent, Area Editor for Network Optimization: Algorithms and Applications. Funding: This work was supported by the U.S. Department of Energy, Office of Electricity [Grant DE-AC02-05CH11231]. The work of R. Jiang was supported in part by the U.S. National Science Foundation, Division of Electrical, Communications and Cyber Systems [Grant ECCS-1845980] and the U.S. Air Force Office of Scientific Research [Grant FA9550-23-1-0323]. Supplemental Material: The software that supports the findings of this study is available within the paper and its Supplemental Information ( https://pubsonline.informs.org/doi/suppl/10.1287/ijoc.2025.1210 ) as well as from the IJOC GitHub software repository ( https://github.com/INFORMSJoC/2025.1210 ). The complete IJOC Software and Data Repository is available at https://informsjoc.github.io/ .

Estrada-Garcia, Juan-Alberto

Plasma-free hydrogenation of oxygen-terminated polycrystalline diamond as determined by circular transmission line measurements (CTLM)

Here, we developed a process to fully hydrogen-terminate diamond by annealing in forming gas. The surface was characterized using circular transmission line measurements (CTLMs) to evaluate the onset and degree of hydrogen termination. No hydrogenation occurred at temperatures at or below 500 °C. Hydrogenation occurs after annealing for 5 min at temperatures between 600 and 1000 °C, with complete hydrogenation achieved at 1000 °C, which showed the same sheet resistance as diamond terminated in a hydrogen plasma. Annealing at temperatures lower than 1000 °C resulted in only partial hydrogenation but can be compensated by increasing the anneal time. At temperatures exceeding 1100 °C, the sheet resistance suddenly and drastically increases, indicating instability of a hydrogen-terminated diamond surface at elevated temperatures under forming gas. The activation energy was determined to be 1.20eV. SEM inspection showed that annealing in hydrogen produced significantly reduced surface roughness compared to diamond surfaces hydrogenated in a H 2 plasma.

36 MATERIALS SCIENCE

Quality and Loss Factor Analysis of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons in a magnetic field, which produces extremely small signals requiring low-loss cryogenic transmission lines for readout to reduce noise and attenuation. Yttrium Barium Copper Oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss superconducting cables such as Niobium (Nb) and Niobium Titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We evaluate their suitability by characterizing the quality and loss factors of five stripline resonators (three YBCO, and copper and silver references) from the Brookhaven Technology Group at 77 K without an external field, and cooled to 30 mK in a 14 T magnet. For measurements at 77 K we recorded scattering parameter data and employed Lorentzian and circle-fitting analysis techniques. We identified the best-performing resonator and developed a cryogenic probe for future testing in the magnet at millikelvin temperatures.

Marinos, Zoe [UCLA]