Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transmission Electron Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Advanced techniques in automated high-resolution scanning transmission electron microscopy

Scanning transmission electron microscopy is a common tool used to study the atomic structure of materials. It is an inherently multimodal tool allowing for the simultaneous acquisition of multiple information channels. Despite its versatility, however, experimental workflows currently rely heavily on experienced human operators and can only acquire data from small regions of a sample at a time. Here, we demonstrate a flexible pipeline-based system for high-throughput acquisition of atomic-resolution structural data using an all-piezo sample stage applied to large-scale imaging of nanoparticles and multimodal data acquisition. As a result, the system is available as part of the user program of the Molecular Foundry at Lawrence Berkeley National Laboratory.

4D-STEM↗

A machine-learning approach to measure 3D sample properties from 2D Transmission Electron Microscopy images

Transmission Electron Microscopy (TEM) is a powerful tool for the characterization of materials at the nanoscale; however, its inherent two-dimensional (2D) nature poses significant challenges to accurately measure three-dimensional (3D) properties. We introduce a supervised machine-learning model that predicts 3D structural information, such as sample thickness and curvature, from a series of conventional 2D TEM images. The model, a U-Net convolutional neural network, is trained on a large synthetic dataset generated from dynamical diffraction simulations that model TEM’s complex, nonlinear image formation, accounting for sample thickness and curvature. This physically realistic framework enables exploration of a broad parameter space impractical to sample experimentally. We demonstrate that the trained model has accurate predictions for experimental single-crystal silicon samples, achieving performance comparable to established measurement techniques. This work highlights the critical role of robust, simulation-based training in overcoming the limitations of real-world imaging artifacts and inconsistent sample geometries. By integrating machine learning with numerical simulations, we offer an efficient and scalable framework for quantitative TEM analysis, paving the way for more sophisticated 3D characterization of complex materials.

Dynamical diffraction↗

Structural characterization and gas reactions of small metal particles by high resolution in-situ TEM (Transmission Electron Microscopy) and TED (Transmission Electron Diffraction)

The detection and size analysis of small metal particles supported on amorphous substrates becomes increasingly difficult when the particle size approaches that of the phase contrast background structures of the support. An approach of digital image analysis, involving Fourier transformation of the original image, filtering, and image reconstruction was studied with respect to the likelihood of unambiguously detecting particles of less than 1 nm diameter on amorphous substrates from a single electron micrograph.

Heinemann, K.↗

Multi-scale imaging of high-pressure hydrogen induced damage in EPDM rubber using X-ray microcomputed tomography, helium-ion microscopy and transmission electron microscopy

Ethylene propylene diene (EPDM) rubber has gained increasing interest for use in hydrogen infrastructure due to its excellent sealing performance and low temperature properties. However, severe structural damage has been observed in EPDM O-rings after exposure to high-pressure hydrogen. The origination and propagation mechanisms of this damage are poorly understood. Here, to address this knowledge gap, multi-scale imaging leveraging X-ray micro-computed tomography (micro-CT), helium ion microscopy (HeIM), and transmission electron microscopy (TEM) were used in this work to study a series of sulfur-cured ethylene propylene diene (EPDM) rubber materials with varying additives that were exposed to different hydrogen environments. Micro-CT captured the substantial structural damage due to hydrogen exposure; it revealed an association between zinc oxide (ZnO) particles and damage initiation. Further studies by TEM and scanning TEM with energy dispersive X-ray spectroscopy (EDS) were focused on these particles at the micro-to nano-scale range. TEM indicated that hydrogen causes void formation at the interface between ZnO and the rubber matrix. HeIM enabled imaging of surface morphology of the material at high resolution pre- and post-hydrogen exposure while providing information on chemical composition and that cannot be captured by either micro-CT or TEM.

08 HYDROGEN↗

Transmission Electron Microscopy of Carbonaceous Matter in Bennu Aggregate Samples

Preliminary analyses of regolith samples from asteroid Bennu show high bulk carbon abundances (~4.7 wt.%). The organic matter is readily apparent in scanning electron microscopy (SEM), transmission electron microscopy (TEM), and NanoSIMS observations. A major objective of the OSIRIS-REx mission is to understand the nature and origin of the pre-biotic organic matter inventory in Bennu samples. Here we report on TEM studies of indigenous organic matter in Bennu aggregate samples.

L P Keller↗

In Situ Observation of Carbonaceous Material in the Matrices of CV and CM Carbonaceous Chondrites: Preliminary Results from Energy Filtered Transmission Electron Microscopy

Energy filtered transmission electron microscopy shows that organic matter can be detected in situ in the matrices of carbonaceous chondrites at a spatial resolution of at least 1 nm. In CM chondrites, carbon is often associated with sulfide particles. Additional information is contained in the original extended abstract.

Brearley, A. J.↗

Grain Boundary Plane Measurement Using Transmission Electron Microscopy Automated Crystallographic Orientation Mapping for Atom Probe Tomography Specimens

Abstract Grain boundaries are critical in determining the properties of materials, including mechanical stability, conductivity, and corrosion resistance. The specific properties of materials depend not only on the misorientation of the crystals, the three most commonly characterized parameters, but also on the angle of the grain boundary plane between the two crystals, the final two parameters in the five-parameter macroscopic description of the grain boundary. The method presented here allows for the direct measurement of all five parameters of the grain boundary in a transmission electron microscopy specimen of various morphologies. This is especially applicable to atom probe specimens, where only a single-tilt axis is generally available, allowing the crystallographic description to be matched to the detailed chemical data available in the atom probe tomography. This method provides a platform for efficient grain boundary analysis in unique samples, saving operator time and allowing for ease of acquisition and interpretation in comparison with traditional electron diffraction methods.

Materials Science↗

Transmission electron microscopy characterization of the fuel-cladding chemical interactions in HT9 cladded U-10Zr fuel

Fuel cladding chemical interaction (FCCI) is a key phenomenon needs to be better understood to establish the design basis for U-10Zr metallic fuel performance. Characterizing the microstructure and chemical composition of FCCI at micron and sub-micron scale is critically important toward a more mechanistic understanding of FCCI phenomenon and its potential effects on cladding integrity and metallic fuel performance. This paper, by using transmission electron microscopy, investigated the FCCI region in HT9 cladded U-10Zr fuel irradiated to 5.7% FIMA burnup at a peak inner cladding temperature of 615 °C in Fast Flux Test Facility (FFTF). Four distinct layers are identified in the FCCI region. The migration of Fe into the fuel side leads to the formation of several U-Zr-Fe ternary phases, including ?-Fe0.5Zr0.32U0.18, e-Fe0.3Zr0.4U0.3, and ?-Fe0.06Zr0.23U0.71, mingled with UFe2, U6Fe, and U phase at various Fe penetration depth up to ~ 150 µm. On the cladding side, grain coarsening and significant lanthanides infiltration along grain boundaries are observed. Laves phase, (Fe,Cr)2(Mo,W), which typically does not exist in fresh HT9, is identified in a wide radial range in the cladding. The typical HT9 martensitic lath structure and pre-existing M23C6 precipitates disappear, partially or completely, depending on the radial distance from the fuel-cladding interface. Those microstructural and compositional changes could cause mechanical degradation in the HT9 cladding. The present characterization results will improve the understanding of FCCI phenomenon and facilitate the development of microstructure-informed FCCI modeling for metallic fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

A parametric study of single-wall carbon nanotube growth by laser ablation

Results of a parametric study of carbon nanotube production by the double-pulse laser oven process are presented. The effect of various operating parameters on the production of single-wall carbon nanotubes (SWCNTs) is estimated by characterizing the nanotube material using analytical techniques, including scanning electron microscopy, transmission electron microscopy, thermo gravimetric analysis and Raman spectroscopy. The study included changing the sequence of the laser pulses, laser energy, pulse separation, type of buffer gas used, operating pressure, flow rate, inner tube diameter, as well as its material, and oven temperature. It was found that the material quality and quantity improve with deviation from normal operation parameters such as laser energy density higher than 1.5 J/cm2, pressure lower than 67 kPa, and flow rates higher than 100 sccm. Use of helium produced mainly small diameter tubes and a lower yield. The diameter of SWCNTs decreases with decreasing oven temperature and lower flow rates.

Nanotubes, Carbon/chemistry↗

Deep learning-based noise filtering toward millisecond order imaging by using scanning transmission electron microscopy

Application of scanning transmission electron microscopy (STEM) to in situ observation will be essential in the current and emerging data-driven materials science by taking STEM’s high affinity with various analytical options into account. As is well known, STEM’s image acquisition time needs to be further shortened to capture a targeted phenomenon in real-time as STEM’s current temporal resolution is far below the conventional TEM’s. However, rapid image acquisition in the millisecond per frame or faster generally causes image distortion, poor electron signals, and unidirectional blurring, which are obstacles for realizing video-rate STEM observation. Here we show an image correction framework integrating deep learning (DL)-based denoising and image distortion correction schemes optimized for STEM rapid image acquisition. By comparing a series of distortion corrected rapid scan images with corresponding regular scan speed images, the trained DL network is shown to remove not only the statistical noise but also the unidirectional blurring. This result demonstrates that rapid as well as high-quality image acquisition by STEM without hardware modification can be established by the DL. The DL-based noise filter could be applied to in-situ observation, such as dislocation activities under external stimuli, with high spatio-temporal resolution.

47 OTHER INSTRUMENTATION↗

Heterogeneous Distribution of Carbonaceous Material in Murchison Matrix: In Situ Observations Using Energy Filtered Transmission Electron Microscopy

Energy filtered TEM (Transmission Electron Microscopy) has been used to study the location of carbonaceous material in situ in Murchison matrix. Carbon occurs frequently as narrow rims around sulfide grains, but is rare in regions of matrix that are dominated by phyllosilicates. Additional information is contained in the original extended abstract.

Brearley, Adrian J.↗

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE↗

Quantitative phase retrieval and characterization of magnetic nanostructures via Lorentz (scanning) transmission electron microscopy

Magnetic materials phase reconstruction using Lorentz transmission electron microscopy (LTEM) measurements have traditionally been achieved using longstanding methods such as off-axis holography (OAH) fast-Fourier transform technique and the transport-of-intensity equation (TIE). The increase in access to processing power alongside the development of advanced algorithms have allowed for phase retrieval of nanoscale magnetic materials with greater efficacy and resolution. Specifically, reverse-mode automatic differentiation (RMAD) and the extended electron ptychography iterative engine (ePIE) are two recent developments of phase retrieval that can be applied to analyzing micro-to-nano- scale magnetic materials. This work evaluates phase retrieval using TIE, RMAD, and ePIE in simulations of Permalloy (Ni 80 Fe 20 ) nanoscale islands, or nanomagnets. Extending beyond simulations, we demonstrate total phase retrieval and image reconstructions of a NiFe nanowire using OAH and RMAD in LTEM and ePIE in Lorentz-mode-4D scanning transmission electron microscopy experiments and determine the saturation magnetization through corroborations with micromagnetic modeling. Finally, we demonstrate the efficacy of these methods in retrieving the total phase and highlight its use in characterizing and analyzing the proximity effect of the magnetic nanostructures.

Lorentz transmission electron microscopy↗

The Correlation of Structural, Chemical, and Electronic Properties of Small Metal Particles and Their Alloys

The low pressure interaction of CO with small Ru particles supported on ultrahigh vacuum (UHV) cleaved mica was studied using flash thermal desorption, Auger electron microscopy, transmission electron microscopy, and transmission electron diffraction. Average particle sizes for these experiments varied between 1.2 and 16 nm. A careful search for CO decomposition on the Ru particles revealed no evidence of dissociaiton over a temperature range and pressure range of 300 to 550 C and 10 to the minus 11th power to 10 to the minus 6th millibar, respectively. Cas and heat treatments caused significant morphological changes and dispersion in the Ru particles, which affected CO desorptiom These effects were dependent on the particle size.

Source record↗

End-to-End Automated Segmentation Framework for Four-Dimensional Scanning Transmission Electron Microscopy Data

Four-dimensional scanning transmission electron microscopy (4D-STEM) is powerful for rapidly characterizing arrays of nanoparticles produced via high-throughput synthesis. However, such 4D-STEM datasets typically contain thousands of nanoparticles, each characterized by thousands of diffraction patterns spatially distributed across the nanoparticle, necessitating efficient and comprehensive analysis. We propose an end-to-end segmentation framework to automatically segment each nanoparticle into regions with distinct composition/orientation of crystal grains, using only the 4D-STEM data. Bragg disk information is extracted in a physics-informed manner from the diffraction patterns at each spatial location and combined with the real space coordinates to form feature vectors. These feature vectors are then used as inputs to a Gaussian mixture model (GMM) to segment the nanoparticle into distinct regions. We also develop two visualization tools based on the GMM outputs to infer the interface transition and the degree of superposition. Our framework comprehensively integrates machine learning tools and physics knowledge, and provides a basis for substantially compressing enormous 4D-STEM datasets, e.g., by replacing the full 4D-STEM dataset for each nanoparticle with only a single set of Bragg disk features for each distinct crystal grain identified in the nanoparticle. In this article, we demonstrate the power of our framework by presenting results for real, complex datasets.

47 OTHER INSTRUMENTATION↗

An ultrahigh vacuum multipurpose specimen chamber with sample introduction system for in situ transmission electron microscopy investigations

A commercial transmission electron microscope (TEM), with flat-plate upper pole piece configuration of the objective lens, and top-entry specimen introduction was modified by introducing an ultrahigh vacuum (UHV) specimen chamber for in situ TEM experimentation. The pumping and design principles and special features of this UHV chamber, which makes it possible to obtain 5 x 10 to the -10th mbar pressure at the site of the specimen, while maintaining the airlock system that allows operation in the 10 to the -10th mbar range within 15 min after specimen change, are described. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) were achieved. Schematic drawings and design dimensions are included.

Heinemann, K.↗