Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Transient modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Transient Modeling and Simulation of a Generic Stable Salt Reactor

A SAM system-level model of a generic stable salt reactor has been developed to investigate thermal-hydraulic behavior and safety performance under steady and transient conditions. The model integrates information generated from a reactor physics analysis using PROTEUS and PERSENT, and a computation fluid dynamics (CFD) analysis using STAR-CCM+. A loose, iterative coupling scheme between PROTEUS and SAM is implemented to calculate the equilibrium power and temperature distributions in the steady-state critical core condition. The converged steady-state model is then used in PERSENT to calculate the four reactivity feedback temperature coefficients (Doppler, fuel density, coolant density, and core radial expansion) and kinetic parameters that are needed in SAM to model the temperature feedback effects in transient simulations. Within the fully enclosed liquid fuel pins, natural convection is the dominant heat transfer mechanism. The STAR-CCM+ model of the fuel pin considers conjugate heat transfer from the liquid fuel salt to the pin cladding and external reactor coolant. The CFD results of the axial and radial temperature profiles are used to empirically determine an effective fuel salt thermal conductivity in the SAM fuel pin model so that the temperatures predicted by the SAM model match as closely as possible the CFD results. In the central region of the fuel pin, the effective thermal conductivity is as high as similar to 60 times the physical fuel salt thermal conductivity. The whole-plant SAM model is then used to simulate an unprotected station blackout transient. The results of this simulation showed that the large negative fuel axial expansion reactivity feedback reduces fission power to similar to 2.4% nominal power. The core is cooled by natural circulation, which removes heat in the core to the emergency heat removal system, and ultimately, to the ambient. However, peak fuel salt and cladding temperatures can potentially reach as high as 1500 K, albeit briefly, if the shutdown mechanism fails to operate.

stable salt reactor; transient simulations; system

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies: Beta Release

The magnitude and complexity of electricity usage patterns from large data centers are having significant impacts on the operation and dynamics of the power grid; grid operators and planners require a range of specialized data center models to properly evaluate these impacts and specify technical solutions as needed. Towards addressing this need, Pacific Northwest National Laboratory (PNNL) has developed a library of electromagnetic transient (EMT) models for grid-level studies of data centers called the data center model library (DML). This report describes how the DML was created and how it may properly be used. This report details the DML’s beta release, completed in July 2026. This is a revision and expansion of the alpha release, which was made available in January 2026 The models present in the DML are generic models; subject matter expertise and additional technical data are needed to modify these models before they can represent any real data center. However, they will significantly reduce the level of effort required to develop site-specific models and can serve as a common starting point to guide industry towards a more refined consensus. Most of the models within DML are dedicated to representing the power electronics interfaces commonly used in modern data centers, such as double-conversion uninterruptible power supplies and single-phase power factor correction converters. These models are intended for use in grid-level studies and are a simplified aggregation of many small components. That said, background material on the physical and electrical design of large data centers is provided as companion material so that users can be aware of many of the details which have been omitted or streamlined as a matter of practical necessity. Additionally, guidance on the application of EMT analysis for data center interconnection studies is provided, which aids users in identifying when the DML is necessary and what sort of additional model development may be necessary for conducting real-world studies.

electromagnetic transients

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies

The magnitude and complexity of electricity usage patterns from large data centers are having significant impacts on the operation and dynamics of the power grid; grid operators and planners require a range of specialized data center models to properly evaluate these impacts and specify technical solutions as needed. Towards addressing this need, Pacific Northwest National Laboratory (PNNL) has developed a library of electromagnetic transient (EMT) models for grid-level studies of data centers called the data center model library (DML). This report describes how the DML was created and how it may properly be used. The models present in the DML are generic models; subject matter expertise and additional technical data are needed to modify these models before they can represent any real data center. However, they will significantly reduce the level of effort required to develop site-specific models and can serve as a common starting point to guide industry towards a more refined consensus. Most of the models within DML are dedicated to representing the power electronics interfaces commonly used in modern data centers, such as double-conversion uninterruptible power supplies and single-phase power factor correction converters. These models are intended for use in grid-level studies and are a simplified aggregation of many small components. That said, background material on the physical and electrical design of large data centers is provided as companion material so that users can be aware of many of the details which have been omitted or streamlined as a matter of practical necessity. Additionally, guidance on the application of EMT analysis for data center interconnection studies is provided, which aids users in identifying when the DML is necessary and what sort of additional model development may be necessary for conducting real-world studies.

24 POWER TRANSMISSION AND DISTRIBUTION

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 2 – Transient modeling and pump-down path selection

Low-pressure conditions required for operation of helium cryogenic systems below the normal boiling point (i.e. 4.2 K) are established through a transient process, commonly referred to as ‘pump-down’. This process is defined as the transition from pressures above atmospheric conditions to the saturation pressure which corresponds to a specified operational temperature. The FRIB 2 K system consists of five cryogenic centrifugal compressors which are operated in series. Historically, the pump-down process path has been established through empirical methods and system operator experience. Investigation into the pump-down process at FRIB aimed to develop a pump-down methodology which relies on theoretical model predictions rather than empirically developed process paths. Ensuring stable operation during the pump-down process involved application of a centrifugal compressor performance prediction model, which is described in Part 1 of this paper. Compressor performance maps can be directly used to evaluate the stability of a selected pump-down path and anticipate the overall reliability of the selected path. In conjunction with the compressor performance maps, a system pressure model was developed to estimate the transient pressure response during the pump-down process. Lastly, an explicit equation was developed to establish a mass flow rate profile for the pump-down process. Implementation of the presented methodology (including the developed models) allows for the system operator to determine a continuous pump-down path which maintains compressor stability while conforming to overall system capabilities. Altogether, the methodology presented has resulted in simplification of transient pump-down operations and increased the reliability, stability and efficiency of the pump-down process.

Compressor train control

Electromagnetic Transient Modeling of Data Centers

This report serves as a user manual for the accompanying EMT model library developed by the National Laboratory of the Rockies (NLR) for various equipment in large data centers. The EMT model library enables detailed modeling of large data center loads for conducting grid stability studies. The EMT model library for data centers include detailed models of a 5.5 kW power supply unit (PSU), a 2.5 uninterruptible power supply (UPS), a 260 MW gas turbine-generator, a 500 kW motor load, and a 33 kW IT rack. These components represent all major equipment in data centers that need to be modeled for performing grid stability studies for data centers.

24 POWER TRANSMISSION AND DISTRIBUTION

A Transient Hydrodynamic Model of Screen Channel Liquid Acquisition Devices for In-Space Cryogenic Propellant Management

Screen channel liquid acquisition devices (LADs) will play a crucial role in future deep space travel. It is essential that vapor-free delivery of propellants during tank-to-tank transfer is ensured to maximize yield from storage tanks and prevent potential combustion instabilities. The screen channel LAD utilizes a fine screen wire mesh that can separate phases in a low Bond number (i.e. microgravity) environment using surface tension forces. This study presents the development and verification of a new model for transient screen compliance, one of the influential factors for screen channel LAD design. Screen compliance is crucial during LAD channel outflow transients because the slight deflection of the screen can provide needed mass to satisfy rapid outflow demands and reduce the pressure difference across the screen. The model is successfully verified against CFD simulations. In addition, the characteristic speed for the governing screen compliance equations is derived which allows for numerical stability criteria to be established. As shown in this study, the transient maximum pressure difference across the screen can greatly exceed the steady state maximum pressure difference across the screen in many cases.

Hydrodynamics Simulations

A bespoke model of Arctic river basins based on hillslope delineation: Model Archive

This dataset is a model archive of the paper A bespoke model of Arctic river basins based on hillslope delineation (in prep), which introduces a watershed decomposition and parameterization method for large scale permafrost hydrology simulation. With this dataset, this study aims to address the research question: whether a computationally efficient hillslope-based modeling framework can reliably simulate discharge at Arctic river-basin scales. This dataset contains model input and output data for five modeling scenarios at a study site located in the Sagavanirktok River basin. The five modeling scenarios include three modeling cases under temperate conditions using full 3D, decomposed 3D, and decomposed 2D modeling strategies; and two modeling cases under actual Arctic conditions with permafrost using full 3D and decomposed 2D modeling strategies. Simulations were performed using the Advanced Terrestrial Simulator (ATS, v1.6 for three temperate scenarios and v1.5 for two Arctic scenarios), a physics-rich integrated surface–subsurface hydrologic model with cryo-hydrology features. For the three temperate models, simulations were conducted for the period of 10/01/1993 - 09/30/2002; and for the two Arctic models, simulations were conducted for the period of 01/01/1994 - 12/31/2002. To facilitate reproducibility of simulations, all datasets are organized hierarchically. The dataset contains: (1) Mesh files (.exo) for full 3D model, decomposed 3D models, and decomposed 2D models, located in huc/190604020802_gauge15906000/mesh/. Mesh files can be visualized through Paraview or read by Python. (2) Climate forcings (.h5) for full 3D model and decomposed 3D/2D models are located in huc/190604020802_gauge15906000/daymet_onePiece/, and huc/190604020802_gauge15906000/vp_pr_revised_daymet_1980_2006_with_wind/ separately. Accessible by Python. (3) Raw measured gage discharge (.csv) from USGS, located in huc/190604020802_gauge15906000/gaged_basin15906000_discharge_usgs/. Accessible by Python. (4) Delineated subdomain raster (.tif) and shape files (.shp), and the final parameterized results (.npy) for decomposed models, located in huc/190604020802_gauge15906000/data_preprocessed-meshing. Accessible by Python. (5) Temperate models are located in nonpermaf_huc190604020802_gauge15906000/, which includes three cases: decomposed 2D models (inside model_0*-hillslope_*), decomposed 3D models (inside model_1*-subcatchment_*), and full 3D model (inside model_2*-onepiece_*). Two step spin-up results (checkpoint_final.h5) are located in model_*1-*_spinup_steadystate and model_*2-*_spinup_cycle, separately, which are used to initialize real transient models. The input files (.xml) and output results (.dat) of the real transient models are located in model_*3-*_transient/. Especially, for two example hillslope models (ID=-11 and 11), additional h5py files are included in model_03-hillslope_transient/hillslope-11/, model_03-hillslope_transient/hillslope11, model_13-subcatchment_transient/subcatchment-11/, model_13-subcatchment_transient/subcatchment/11, respectively, which are used to plot the saturation figure (Figure 5) in the manuscript. Accessible by Python. (6) Arctic models are located in huc190604020802_gauge15906000/, which includes two cases: decomposed 2D models (inside model_04-hillslope_transient), and full 3D model (inside model_05-onepiece_transient_mannp1_ra). Three step spin-up results (checkpoint_final.h5) are located in model_01-column_freezeup/, model_02-column_spinup/, model_03-hillslope_spinup/, respectively, which are used to initialize real 2D transient hillslope models. The input files (.xml) and output results (.dat) of transient 2D hillslope models are located in model_04-hillslope_transient/. The input files (.xml) and output results (.dat) of the full 3D transient model is located in model_05-onepiece_transient_mannp1_ra/. The full 3D transient model is initialized by model_02-column_spinup/. Accessible by Python. (7) The MOSART routed discharge results (.csv) under Arctic conditions is located in huc190604020802_gauge15906000/MOSART/. Accessible by Python. (8) All Python codes (.py) used to parameterize full 3D model to decomposed 2D models are located in script/. These codes fit with watershed workflow (a watershed delineation tool) v1.4 under the branch gaob/v1.4 from https://github.com/gaobhub/watershed-workflow.git.

EARTH SCIENCE > CRYOSPHERE

Discovering CO Adsorption and Desorption Pathways from Chemical Reaction Neural Network Modeling of Transient Kinetics Spectroscopy

Here, we demonstrate a data-driven approach to interpreting surface reactions by combining time-resolved gas pulsing infrared spectroscopy with chemical reaction neural networks (CRNNs). Using CO adsorption and desorption on Pd(111) at 460–490 K as a model system, we show how transient kinetic data can reveal detailed reaction mechanisms. Starting with a simple one-species model, we systematically evaluate increasingly complex mechanisms involving hollow and bridge site adsorption. Despite the similar goodness of fit to the same experimental absorbance data, our models predict distinct coverage dynamics for different adsorption sites. Through analysis of spectral peak stability and predicted dynamics, we identify a mechanism in which CO primarily adsorbs on bridge sites followed by rapid conversion to hollow sites as being the most physically consistent with experimental observations. This work provides a framework for extracting mechanistic insights from limited experimental data, demonstrating how machine learning can bridge the gap between transient kinetic measurements and a molecular-level understanding of surface reactions.

36 MATERIALS SCIENCE

OpenUniverse2024: a shared, simulated view of the sky for the next generation of cosmological surveys

The OpenUniverse2024 simulation suite is a cross-collaboration effort to produce matched simulated imaging for multiple surveys as they would observe a common simulated sky. Both the simulated data and associated tools used to produce it are intended to uniquely enable a wide range of studies to maximize the science potential of the next generation of cosmological surveys. We have produced simulated imaging for approximately 70 deg 2 of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) Wide-Fast-Deep survey and the Nancy Grace Roman Space Telescope High-Latitude Wide-Area Survey, as well as overlapping versions of the ELAIS-S1 Deep-Drilling Field for LSST and the High-Latitude Time-Domain Survey for Roman. OpenUniverse2024 includes (i) an early version of the updated extragalactic model called Diffsky, which substantially improves the realism of optical and infrared photometry of objects, compared to previous versions of these models; (ii) updated transient models that extend through the wavelength range probed by Roman and Rubin; and (iii) improved survey, telescope, and instrument realism based on up-to-date survey plans and known properties of the instruments. It is built on a new and updated suite of simulation tools that improves the ease of consistently simulating multiple observatories viewing the same sky. The approximately 400 TB of synthetic survey imaging and simulated universe catalogs are publicly available, and we preview some scientific uses of the simulations.

large-scale structure of Universe

Testing and Modeling of Subscale Ice-on-Coil Module as Low Temperature Reservoir for sCO2 based Pumped Thermal Energy Storage Systems

Echogen tested approximately 10 kWthsubscale IOC system in their lab in Akron, OH for studying the feasibility, endurance and performance impact of the technology on PTES system. This paper discusses the test loop setup, testing and results from this sub-scale IOC testing. Along with testing, the project team also developed sub-scale IOC transient model. The paper discusses this transient model development and its validation against the test data.

Avadhanula, Vamshi Krishna [Echogen Power Systems

Adaptive Interface-PINNs (AdaI-PINNs) for transient diffusion: Applications to forward and inverse problems in heterogeneous media

We model transient diffusion in heterogeneous materials using a novel physics-informed neural networks framework (PINNs) termed Adaptive interface physics-informed neural networks or AdaI-PINNs (Roy et al. arXiv preprint arXiv:2406.04626, 2024). AdaI-PINNs utilize different activation functions with trainable slopes tailored to each material region within the computational domain, allowing for a fully automated and adaptive PINNs approach to model interface problems with strongly and weakly discontinuous solutions. To enhance its performance in highly heterogeneous transient diffusion systems, we prescribe a suite of robust practices, including appropriate non-dimensionalization of equations, a biased sampling method, Glorot initialization, and the hard enforcement of boundary and initial conditions. Here we evaluate the efficacy of the proposed method on several benchmark forward and inverse problems. Comparative studies on one-dimensional and two-dimensional benchmark problems reveal that the modified AdaI-PINNs outperform its unmodified counterpart, achieving root-mean-square errors that are at least two orders of magnitude better in forward problems. For inverse problems, the maximum errors in the approximated diffusion coefficients by modified AdaI-PINNs are four orders of magnitude better than those of the unmodified version. Additionally, modified AdaI-PINNs demonstrate improved stability in problems with large material mismatches.

42 ENGINEERING

Deep Learning-enhanced Block-Diagram Modeling of Solar Power Systems

Data-driven models of power system inverter-based resources are desired to run simulations faster than with detailed electromagnetic transient models, to hide proprietary design details, to support control system design applications, and to aggregate the effects of distributed energy resources. This paper applies a customized Hammerstein Wiener framework to train block diagram models from thousands of electromagnetic transient simulations or experimental test records. The block diagram models integrate with larger grid simulations as voltagecontrolled current sources or current-controlled voltage sources for several simulators. Guidelines for block architecture and training are presented. Three-phase balanced, three-phase unbalanced, and single-phase examples all achieve an acceptable root mean square error of no more than 0.05 per-unit.

Mcdermott, Thomas E. [Private consulting company]

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING

SSR APPLIED – Automated Power Plants: Intelligent, Efficient and Digitised (V.2)

This report describes work undertaken during the SSR APPLIED project. The focus of the project has been on the development of digital twins to de-risk licensing of improved operating and maintenance practices. The operation of a bespoke flowing separate effects molten salt loop at ANL, with realistic temperature gradients, will provide invaluable data for computer codes validation. Three digital twins of aspects of the SSR-W have been successfully developed using ANL expertise and software. These digital twins have demonstrated optimization of the fuel cycle, the ability to model transients using an integrated coupled neutronic – thermal-hydraulic model with a model of the fuel expansion feedback so important to the inherent safety of the SSR-W. Advanced machine learning techniques have been developed and demonstrated for optimization of heat exchanger operation and maintenance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS