Optical transformation of field ion micrographs
Optical transformation of field ion micrographs providing orthographic, gnomonic projections and perspective images of hemispheric metal surface
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Optical transformation of field ion micrographs providing orthographic, gnomonic projections and perspective images of hemispheric metal surface
Sources of noise and error correcting procedures characteristic of Hadamard transform optical systems were investigated. Reduction of spectral noise due to noise spikes in the data, the effect of random errors, the relative performance of Fourier and Hadamard transform spectrometers operated under identical detector-noise-limited conditions, and systematic means for dealing with mask defects are among the topics discussed. The distortion in Hadamard transform optical instruments caused by moving Masks, incorrect mask alignment, missing measurements, and diffraction is analyzed and techniques for reducing or eliminating this distortion are described.
Error sources encountered in Hadamard transform optical instruments are discussed. Such errors are caused by factors including moving masks, incorrect mask alignment, defects in mask fabrication, missing data, drifts in background level, and diffraction. Techniques for error reduction and/or elimination are described for each of the cases considered. It is noted that the errors described occur in singly encoded spectrometers and imagers.
An investigation of visuomotor adaptation to optical rotation and optical inversion was conducted. Experiment 1 examined the visuomotor adaptability of subjects to an optically rotating visual world with a univariate repeated measures design. Experiment 1A tested one major prediction of a model of adaptation put forth by Welch who predicted that the aversive drive state that triggers adaptation would be habituated to fairly rapidly. Experiment 2 was conducted to investigate the role of motor activity in adaptation to optical rotation. Specifically, this experiment contrasted the reafference hypothesis and the proprioceptive change hypothesis. Experiment 3 examined the role of cognition, error-corrective feedback, and proprioceptive and/or reafferent feedback in visuomotor adaptation to optical inversion. Implications for research and implications for practice were suggested for all experiments.
The design, fabrication, and initial characterization of a miniature single-pass Fourier-transform spectrometer (FTS) that has an optical bench that measures 1 cm x 5 cm x 10 cm is presented. The FTS is predicated on the classic Michelson interferometer design with a moving mirror. Precision translation of the mirror is accomplished by microfabrication of dovetailed bearing surfaces along single-crystal planes in silicon. Although it is miniaturized, the FTS maintains a relatively high spectral resolution, 0.1 cm-1, with adequate optical throughput.
Infrared (IR) spectroscopy is a powerful method for mapping chemical heterogeneity on the microscale. Synchrotron IR radiation uniquely provides a high brightness and broad bandwidth to further extend the capabilities of IR spectroscopic imaging. However, the diffraction-limited spatial resolution of IR spectroscopy is insufficient for studies requiring submicrometer spatial differentiation. Optical photothermal IR (O-PTIR) microscopy is a powerful, emerging method that overcomes the IR diffraction limit in IR hyperspectral imaging by employing a modulated IR beam and a visible probe laser beam to detect local temperature-induced modulation at the visible diffraction limit. In this work, we extend the spectral range of photothermal infrared measurements by incorporating a synchrotron IR source, demonstrating a combined synchrotron-based O-PTIR modality that enables high spatial resolution far-field chemical imaging spanning the entire mid-IR range. Both optical- and fluorescence-detected photothermal modalities were performed using a step-scan interferometer, demonstrating improved spectral range (541-4000 cm-1) when compared to optical photothermal microscopy with commercial laser sources (800-1800 cm-1 for this particular source) and improved spatial resolution, when compared to synchrotron microspectroscopy measurements. Following these initial validation studies, synchrotron Fourier-transform fluorescence-detected photothermal IR spectroscopy in combination with synchrotron microspectroscopy measurements was used to differentiate cells in mouse brain tissue sections, which requires submicron spatial resolutions beyond those accessible by IR spectroscopy alone.
This paper gives a brief survey of the design of masks for Hadamard spectrometers and image scanners. Three different criteria are described for judging a mask, as well as techniques for choosing masks that are not too far from the optimum.
We demonstrate a compact real-time optical image correlator using diode lasers and a semi-insulating GaAs/AlGaAs multiple-quantum-well (SI-MQW) device as the holographic element. With only 3 mW of power incident upon the SI-MQW device, the correlation is obtained in 1 microsec and can be erased in as fast as 2 microsec, which presents the possibility of a system capable of 3 x 10 exp 5 correlations/s. We also show that images can be stored for a controllable length of time (2-25 microsec), which presents possibilities for the use of the SI-MQW device as a data or image buffer memory.
Spatial transformations of light are ubiquitous in optics, with examples ranging from simple imaging with a lens to quantum and classical information processing in waveguide meshes. Multi-plane light converter (MPLC) systems have emerged as a platform that promises completely general spatial transformations, i.e., a universal unitary. However, until now, MPLC systems have demonstrated transformations that are far from general, e.g., converting from a Gaussian to Laguerre-Gauss mode. Here, we demonstrate the promise of an MLPC, the ability to impose an arbitrary unitary transformation that can be reconfigured dynamically. Specifically, we consider transformations on superpositions of parallel free-space beams arranged in an array, which is a common information encoding in photonics. We experimentally test the full gamut of unitary transformations for a system of two parallel beams and make a map of their fidelity. We obtain an average transformation fidelity of 0.85 ± 0.03. This high-fidelity suggests that MPLCs are a useful tool for implementing the unitary transformations that comprise quantum and classical information processing.
Initial experimental investigation of the deformable mirror device (DMD) in a joint optical transform correlation is reported. The inverted cloverleaf version of the DMD, in which form the DMD is phase-mostly but of limited phase range, is used. Binarized joint Fourier transforms were calculated for similar and dissimilar objects and written onto the DMD. Inverse Fourier transform was done in a diffraction order for which the DMD shows phase-mostly modulation. Matched test objects produced sharp correlation, distinct objects did not. Further studies are warranted and they are outlined.
The application of logarithmic transformations to speckle images is sometimes desirable in converting the speckle noise distribution into an additive, constant-variance noise distribution. The optical transmission properties of some bacteriorhodopsin films are well suited to implement such a transformation optically in a parallel fashion. I present experimental results of the optical conversion of a speckle image into a transformed image with signal-independent noise statistics, using the real-time photochromic properties of bacteriorhodopsin. The original and transformed noise statistics are confirmed by histogram analysis.
The possibility of producing an integrated optics data processing device based upon Fourier transformations or other parallel processing techniques, and the ways in which such techniques may be used to upgrade the performance of present and projected NASA systems were investigated. Activities toward this goal include; (1) production of near-diffraction-limited geodesic lenses in glass waveguides; (2) development of grinding and polishing techniques for the production of geodesic lenses in LiNbO3 waveguides; (3) development of a characterization technique for waveguide lenses; and (4) development of a theory for corrected aspheric geodesic lenses. A holographic subtraction system was devised which should be capable of rapid on-board preprocessing of a large number of parallel data channels. The principle involved is validated in three demonstrations.
An Electro-Optic Imaging Fourier Transform Spectrometer (EOIFTS) for Hyperspectral Imaging is described. The EOIFTS includes an input polarizer, an output polarizer, and a plurality of birefringent phase elements. The relative orientations of the polarizers and birefringent phase elements can be changed mechanically or via a controller, using ferroelectric liquid crystals, to substantially measure the spectral Fourier components of light propagating through the EIOFTS. When achromatic switches are used as an integral part of the birefringent phase elements, the EIOFTS becomes suitable for broadband applications, with over 1 micron infrared bandwidth.
Flat optical components, or metasurfaces, have transformed optical imaging, data storage, information processing, and biomedical applications by providing unprecedented control over light-matter interactions. These nano-engineered structures enable compact, multidimensional manipulation of light’s amplitude, phase, polarization, and wavefront, producing scalar and vector beams with unique properties such as orbital angular momentum and knotted topologies. This flexibility has potential applications in optical communication and imaging, particularly in complex environments such as atmospheric turbulence and undersea scattering. However, designing metasurfaces for shorter wavelengths, such as visible and ultraviolet light, remains challenging due to fabrication limitations and material absorption. Here, we introduce an innovative concept called topology imprinting using judiciously designed all-dielectric nonlinear optical metasurfaces to replicate desired waveforms at fundamental and harmonic frequencies, opening promising avenues for advanced photonic applications.
Optical imaging systems achieving aperture synthesis by lensless Fourier transform holography, noting X ray astronomy, ultrasonic and space applications
A method is presented for designing optical correlation filters based on measuring three intensity patterns: the Fourier transform of a filter object, a reference wave and the interference pattern produced by the sum of the object transform and the reference. The method can produce a filter that is well matched to both the object, its transforming optical system and the spatial light modulator used in the correlator input plane. A computer simulation was presented to demonstrate the approach for the special case of a conventional binary phase-only filter. The simulation produced a workable filter with a sharp correlation peak.
The paper reports the two observing programs conducted to compare two techniques which have been proposed as methods for performing the requisite Fourier transformations in very large multichannel spectrum analysers (MCSA): the direct digital FFT and optical transform processor. The details of the observations at NRAO utilizing a direct digital FFT are given. A description of the NAIC, Arecibo observations utilizing an optical processor at the Environmental Research Institute of Michigan (ERIM) and a microdensitometer at Electromagnetics System Laboratories (ESL) is presented. For both observing programs, statistical analysis of the power spectra produced by the nonreal-time MCSAs (or post-processing) was accomplished.
A hyrbid real-time vision system concept is proposed for Mars lander guidance and control for the Mars Rover/Sample Return mission. The system includes digital and optical processing methods with high speed digital image warping to preprocess a video image for optical correlation. The system also includes position estimation by synthetic estimation filtering, image stabilization by joint transform optical correlation, and hazard identification from measurements of optical flow by sequential image subtraction.