Guided Trace Reading Optimization
Technical presentation for internal and laboratory audience
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Technical presentation for internal and laboratory audience
This report describes a spherical fitting algorithm that can be used for estimating the oscilloscope film trace coordinates. This algorithm was adopted from a least square algebraic spherical fitting algorithm developed by the author earlier for photovoltaic velocimetry applications. Preliminary assessment suggests that the algorithm may be used for optimizing the coordinates manually digitized by the user, or may be used as an uncertainty estimator for the user’s film reading uncertainties.
Assessment by noninvasive polygraphic techniques of the cardiovascular responses of normal subjects to intravenous injections of glucagon and glucagon diluent. A blinding procedure which eliminated observer bias was used during the reading of tracings. Analysis of group results showed that glucagon provoked uniformly significant changes, including increase in heart rate, blood pressure, pressure-rate product, and ejection time index, and decrease in prejection period, mechanical and electromechanical systole, left ventricular ejection time, and the ratio PEP/LVET. The principal results correlated well with those of previous studies of the hemodynamic effects of glucagon.
Audio tape recordings of selected Skylab communications were processed by a psychological stress evaluator. Strip chart tracings were read blind and scores were assigned based on characteristics reported by the manufacturer to indicate psychological stress. These scores were analyzed for their empirical relationships with operational variables in Skylab judged to represent varying degrees of situational stress. Although some statistically significant relationships were found, the technique was not judged to be sufficiently predictive to warrant its use in assessing the degree of psychological stress of crew members in future space missions.
The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.
From user requirements definition to accepted software system, the software project management wants to be sure that the system will meet the requirements. For the development of a telecommunication satellites Control Centre, C.N.E.S. has used new rules to make the use of tracing matrix easier. From Requirements to Acceptance Tests, each item of a document must have an identifier. A unique matrix traces the system and allows the tracking of the consequences of a change in the requirements. A tool has been developed, to import documents into a relational data base. Each record of the data base corresponds to an item of a document, the access key is the item identifier. Tracing matrix is also processed, providing automatically links between the different documents. It enables the reading on the same screen of traced items. For example one can read simultaneously the User Requirements items, the corresponding Software Requirements items and the Acceptance Tests.
Corrosion of the antireflective coating on the cell ("AR c corrosion") was previously observed in studies using hot-humid test conditions with external high voltage (HV) bias. Because AR c corrosion is not well understood, mini-modules (MiMos) were examined in a comparative experiment using PERC and PERT as well as legacy Al-BSF cells. For separate MiMos with the cell circuit electrical at +1500 V, -1500 V, or unbiased "V oc", test conditions in the comparative study included 60degrees C/60% RH for 96 h, as in IEC TS 62804-1; 70degrees C/70%RH for 200 h; and 85degrees C/85% RH for 200 h. Characterizations at each read point included: camera and electroluminescence (EL) imaging, colorimetry, and I-V curve tracing. Characterizations at the final read point included: SunsVoc; spatially mapping external quantum efficiency (EQE); high resolution: photoluminescence (PL), EL, and dark lock-in thermographic (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos (stepped HV aging) and full-sized modules (outdoor aging) from previous studies. AR c corrosion was specifically observed for the glass/encapsulant/cell side of +1500 V (HV+) stressed MiMos, where appearance, color, and reflectance were the characteristics most distinguished relative to simultaneously occurring degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to silicon oxide or hydrous silica, preferentially occurring at the edges and tips of the pyramidal textured cell surface.
The trace anomaly Δ ≡ 1/3 −𝑃/𝜖 =1/3 −𝜙 quantifies the possibly broken conformal symmetry in supradense matter under pressure 𝑃 at energy density 𝜖. Perturbative QCD (pQCD) predicts a vanishing Δ at extremely high energy or baryon densities when the conformal symmetry is realized but its behavior at intermediate densities reachable in neutron stars (NSs) is still very uncertain. The extraction of Δ from NS observations strongly depends on the employed model for nuclear equation of state (EOS). Using the IPAD-TOV method based on an intrinsic and perturbative analysis of the dimensionless (IPAD) Tolman-Oppenheimer-Volkoff (TOV) equations that are further verified numerically by using 10 5 EOSs generated randomly with a metamodel in a very broad EOS parameter space constrained by terrestrial nuclear experiments and astrophysical observations, here we first show that the compactness 𝜉 ≡ 𝐺𝑀 NS /𝑅𝑐 2 ≡ 𝑀 NS /𝑅 of a NS with mass 𝑀 NS and radius 𝑅 scales very accurately with $\bar{Π}$ c ≡ $Π$ c · (1 +18X/25) ≡ X/(1 +3X 2 +4X) · (1 +18X/25) where X ≡ 𝜙 c = 𝑃 c /𝜖 c is the ratio of pressure over energy density at NS centers. The scaling of NS compactness thus enables one to readily read off the central trace anomaly Δ c = 1/3 −X directly from the observational data of either the mass-radius or red-shift measurements. Finally, we then demonstrate indeed that the available NS data themselves from recent X-ray and gravitational wave observations can determine model insensitively the trace anomaly as a function of energy density in NS cores, providing a stringent test of existing NS models and a clear guidance in a new direction for further understanding the nature and EOS of supradense matter.
CMS is transitioning to use ROOT’s new RNTuple data storage format for the files CMS will write in the HL-LHC era. Based on initial tests, CMS expects faster I/O and smaller files compared to the present TTree storage format. This contribution will show a comprehensive performance comparison between RNTuple and TTree I/O using CMS AOD and MiniAOD data formats as test cases for both simulation and collision data corresponding to similar data taking conditions of LHC Run 3. Quantities such as the resulting file size, the memory usage of the I/O components, and the rate of events being read from a file or written to a file will be measured. CMS’ data processing relies heavily on reading files over the local or wide area networks. The file read patterns are important because the latencies have been seen to influence the total production job times. Therefore a study on the file read patterns will be conducted by recording traces of the offset, size, and timestamp of each read request for both RNTuple and TTree. The behavior of network reads will be mimicked by reading local files where artificial latency will be added to the read requests. The effect of different latency values on the job times will be studied.
For over a decade, genome 43 sequences have adhered to only two standards that are relied on for purposes of sequence analysis by interested third parties (1, 2). However, ongoing developments in revolutionary sequencing technologies have resulted in a redefinition of traditional whole genome sequencing that requires a careful reevaluation of such standards. With commercially available 454 pyrosequencing (followed by Illumina, SOLiD, and now Helicos), there has been an explosion of genomes sequenced under the moniker 'draft', however these can be very poor quality genomes (due to inherent errors in the sequencing technologies, and the inability of assembly programs to fully address these errors). Further, one can only infer that such draft genomes may be of poor quality by navigating through the databases to find the number and type of reads deposited in sequence trace repositories (and not all genomes have this available), or to identify the number of contigs or genome fragments deposited to the database. The difficulty in assessing the quality of such deposited genomes has created some havoc for genome analysis pipelines and contributed to many wasted hours of (mis)interpretation. These same novel sequencing technologies have also brought an exponential leap in raw sequencing capability, and at greatly reduced prices that have further skewed the time- and cost-ratios of draft data generation versus the painstaking process of improving and finishing a genome. The resulting effect is an ever-widening gap between drafted and finished genomes that only promises to continue (Figure 1), hence there is an urgent need to distinguish good and poor datasets. The sequencing institutes in the authorship, along with the NIH's Human Microbiome Project Jumpstart Consortium (3), strongly believe that a new set of standards is required for genome sequences. The following represents a set of six community-defined categories of genome sequence standards that better reflect the quality of the genome sequence, based on our collective understanding of the different technologies, available assemblers, and the varied efforts to improve upon drafted genomes. Due to the increasingly rapid pace of genomics we avoided the use of rigid numerical thresholds in our definitions to take into account the types of products achieved by any combination of technology, chemistry, assembler, or improvement/finishing process.
The artificial gravity pilot project was designed to investigate the efficacy of daily exposure to a Gz acceleration gradient for counteracting the physiologic decrements induced by prolonged bed rest. A short radius centrifuge was used to produce a Gz gradient such that 1 g was applied at the level of the subject s heart and 2.5 g at the feet. For inclusion in the study, subjects were required to complete a 75-minute screening spin on the centrifuge. During the study, each active treatment subject was scheduled for a 60-minute spin each day for 20 consecutive days. During centrifugation, subjects were continuously monitored by a physician for signs and symptoms of pre-syncope, motion sickness, arrhythmias, joint/muscle pain and any other unanticipated problems. The physician was also present to provide emergency care in the case of a medical emergency. Cameras mounted on the centrifuge were used to provide a means of observing the subject s face and torso. Audio communication was continuously maintained. Other monitoring tools included two-lead EKG tracings, pulse oximetry, intermittent sphygmomanometer readings, lights in the peripheral visual field, and continuous blood pressure readout from a tonometry device. Thirty screening runs were attempted using twenty-seven subjects. Seven of these runs were terminated early for symptoms of pre-syncope, motion sickness, or GI distress. A total of eight subjects completed the active treatment arm of the study. Of the 160 centrifuge runs that were scheduled for these eight treatment subjects, 152 were completed, seven were terminated early, and one was not attempted. Of the seven early terminations, four were related to symptoms of pre-syncope, one to leg pain, one to GI discomfort, and one to equipment failure. Three terminations for adverse symptoms occurred on the first treatment day. Three terminations occurred on day nineteen of treatment and within 24 hours after scheduled soleus and quadriceps muscle biopsies. We have summarized the relative usefulness of the information obtained by the various monitoring modalities in making a decision to terminate a centrifuge run. The video and audio communication information was essential to the decision-making process. Heart rate and EKG tracings are considered valuable, even though no spins were terminated due to significant arrhythmias. The tonometer device was generally not reliable in this application. Our observations suggest that subjects may be less tolerant of centrifugation just after starting bed rest and after invasive procedures.
In this paper we study the performance of the Lustre file system using five scientific and engineering applications representative of NASA workload on large-scale supercomputing systems such as NASA s Pleiades. In order to facilitate the collection of Lustre performance metrics, we have developed a software tool that exports a wide variety of client and server-side metrics using SGI's Performance Co-Pilot (PCP), and generates a human readable report on key metrics at the end of a batch job. These performance metrics are (a) amount of data read and written, (b) number of files opened and closed, and (c) remote procedure call (RPC) size distribution (4 KB to 1024 KB, in powers of 2) for I/O operations. RPC size distribution measures the efficiency of the Lustre client and can pinpoint problems such as small write sizes, disk fragmentation, etc. These extracted statistics are useful in determining the I/O pattern of the application and can assist in identifying possible improvements for users applications. Information on the number of file operations enables a scientist to optimize the I/O performance of their applications. Amount of I/O data helps users choose the optimal stripe size and stripe count to enhance I/O performance. In this paper, we demonstrate the usefulness of this tool on Pleiades for five production quality NASA scientific and engineering applications. We compare the latency of read and write operations under Lustre to that with NFS by tracing system calls and signals. We also investigate the read and write policies and study the effect of page cache size on I/O operations. We examine the performance impact of Lustre stripe size and stripe count along with performance evaluation of file per process and single shared file accessed by all the processes for NASA workload using parameterized IOR benchmark.
A general functional description of totally automatic photometry of emission spectra is not available for an operating environment in which the sample compositions and analysis procedures are low-volume and non-routine. The advantages of using an interactive approach to computer control in such an operating environment are demonstrated. This approach includes modular subroutines selected at multiple-option, menu-style decision points. This style of programming is used to trace elemental determinations, including the automated reading of spectrographic plates produced by a 3.4 m Ebert mount spectrograph using a dc-arc in an argon atmosphere. The simplified control logic and modular subroutine approach facilitates innovative research and program development, yet is easily adapted to routine tasks. Operator confidence and control are increased by the built-in options including degree of automation, amount of intermediate data printed out, amount of user prompting, and multidirectional decision points.
An interactive, top-down structured program design is described which produces a general flexible description of totally automatic photometry of emission spectra in an operating environment in which sample compositions and analysis procedures are low-volume and nonroutine. The use of this type of programming is illustrated by a project to computerize trace elemental determinations including the automated reading of spectrographic plates produced by a 3.4-m Ebert mount spectrograph using a dc-arc in an argon atmosphere.
This is training presentation for REA (Reading Error Analysis) software. REA is designed for analyzing UGT scope reading errors and for developing reading points optimization algorithms.
Senior Scientist Harry Miley describes how his work in ultra-trace, nuclear detection technology picked up the first reading of radiological materials over the U.S. following the nuclear power plant explosion in Japan.
Malware attacks are deployed in order to achieve one of the following goals: To disrupt system functionality; To gather sensitive information; To gain access to private data. The top areas that become primary targets for malware to attack are: Availability, Integrity, Confidentiality. Malware forensics is a particular field where the execution and methods of a malware are studied. Malware activity has increased on unprotected mobile devices. Establishing an accurate and ethical approach is critical when assessing security issues. Knowing the method of execution leads to fewer security risks and prevention of future attacks. Our intentions are not to create a new wave of malware attacks, but to study them and point to possible vulnerabilities that can occur. To create a work-flow for desktop computers, the following benchmarks are used: Using an isolated environment, tracing the host processes, using dynamic analysis to isolate the malware and destroy it. The isolated environment will prevent any malignant code from activating and risking the rest of the computers in the vicinity and/or network. Tracing the host processes, will allow us to read the host and user processes, giving us valuable information on the activities of the device. Using dynamic analysis will allow us to manipulate the malware in a number of ways, such as using a debugger to try and change it. We used a virus and a Trojan to infiltrate a desktop computer for the following reasons: A - The virus will inject itself to force data to connect using a port. B - The Trojan will unlock and grant access to an unauthorized port. With the desktop work-flow in place as a systematic approach for mobile applications, we will investigate how to apply the same methods to the mobile devices. We are currently looking into different ways to develop 'friendly' malware to launch on the Android. We will then try to use malignant Windows malware to infect an Android, and using the work-flow try to come to the same conclusion as with the Android and Desktop, separately.
In the search for high sensitivity and direct atmospheric sampling of trace species, techniques have been developed such as atmospheric-sampling, glow-discharge ionization (ASGDI), corona discharge, atmospheric pressure ionization (API), electron-capture detection (ECD), and negative-ion chemical ionization (NICI) that are capable of detecting parts-per-billion to parts-per-trillion concentrations of trace species. These techniques are based on positive- or negative-ion formation via charge-transfer to the target, or electron capture under multiple-collision conditions in a Maxwellian distribution of electron energies at the source temperature. One drawback of the high-pressure, corona- or glow-discharge devices is that they are susceptible to interferences either through indistinguishable product masses, or through undesired ion-molecule reactions. The ASGDI technique is relatively immune from such interferences, since at target concentrations of less than 1 ppm the majority of negative ions arises via electron capture rather than through ion-molecule chemistry. A drawback of the conventional ECD, and possibly of the ASGDI, is that they exhibit vanishingly small densities of electrons with energies in the range 0-10 millielectron volts (meV), as can be seen from a typical Maxwellian electron energy distribution function at T = 300 K. Slowing the electrons to these subthermal (less than 10 meV) energies is crucial, since the cross section for attachment of several large classes of molecules is known to increase to values larger than 10(exp -12) sq cm at near-zero electron energies. In the limit of zero energy these cross sections are predicted to diverge as epsilon(exp -1/2), where epsilon is the electron energy. In order to provide a better 'match' between the electron energy distribution function and attachment cross section, a new concept of attachment in an electrostatic mirror was developed. In this scheme, electrons are brought to a momentary halt by reversing their direction with electrostatic fields. At this turning point the electrons have zero or near-zero energy. A beam of target molecules is introduced, and the resultant negative ions extracted. This basic idea has been recently improved to allow for better reversal geometry, higher electron currents, lower backgrounds, and increased negative-ion extraction efficiency. We present herein application of the so-called reversal electron attachment detector (READ) to the study of negative-ion formation in the explosives molecules RDX, PETN, and TNT under single-collision conditions.