At least 19 records

Time-resolved imaging of atoms and molecules in laser-produced uranium plasmas

Gas-phase oxidation of uranium (U), plume chemistry, and its impact on optical emission features of the uranium plasma are investigated. Plasmas were produced via nanosecond laser ablation of a natural uranium target in a chamber where uranium oxidation was controlled by varying the oxygen partial pressure within argon cover gas. Monochromatic imaging of uranium atoms and monoxide molecules was performed using narrowband optical filters, which clearly reveals the spatio-temporal evolution of these species in the plasma. Uranium oxides are found to be formed at the plasma edges, where lower temperatures favor molecular recombination. Segregation between the distribution of uranium atoms and monoxide species is observed at later times of plasma evolution, and is more apparent at lower oxygen partial pressures. At higher oxygen partial pressures, significant variation in plume morphology is noticed for UO species, which is attributed to higher rate of oxide (UxOy) formation at the plume edges. The monochromatic images of U atoms and molecules and corresponding spectral features at various oxygen partial pressures presented here provide a unique insight into gas-phase, high-temperature uranium oxidation, and its chemistry and have implications for a wide range of nuclear applications, from stand-off detection of radioisotopes to forensics and safeguards.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Role of electron-electron interference in ultrafast time-resolved imaging of electronic wavepackets

Ultrafast time-resolved x-ray scattering is an emerging approach to image the dynamical evolution of the electronic charge distribution during complex chemical and biological processes in real-space and real-time. Recently, the differences between semiclassical and quantum-electrodynamical (QED) theory of light-matter interaction for scattering of ultrashort x-ray pulses from the electronic wavepacket were formally demonstrated and visually illustrated by scattering patterns calculated for an electronic wavepacket in atomic hydrogen [G. Dixit, O. Vendrell, and R. Santra, Proc. Natl. Acad. Sci. U.S.A. 109, 11636 (2012)]. In this work, we present a detailed analysis of time-resolved x-ray scattering from a sample containing a mixture of non-stationary and stationary electrons within both the theories. In a many-electron system, the role of scattering interference between a non-stationary and several stationary electrons to the total scattering signal is investigated. In general, QED and semiclassical theory provide different results for the contribution from the scattering interference, which depends on the energy resolution of the detector and the x-ray pulse duration. The present findings are demonstrated by means of a numerical example of x-ray time-resolved imaging for an electronic wavepacket in helium. It is shown that the time-dependent scattering interference vanishes within semiclassical theory and the corresponding patterns are dominated by the scattering contribution from the time-independent interference, whereas the time-dependent scattering interference contribution do not vanish in the QED theory and the patterns are dominated by the scattering contribution from the non-stationary electron scattering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved imaging of the laser forward transfer of liquids

Time-resolved imaging is carried out to study the dynamics of the laser-induced forward transfer of an aqueous solution at different laser fluences. The transfer mechanisms are elucidated, and directly correlated with the material deposited at the analyzed irradiation conditions. It is found that there exists a fluence range in which regular and well-defined droplets are deposited. In this case, laser pulse energy absorption results in the formation of a plasma, which expansion originates a cavitation bubble in the liquid. After the further expansion and collapse of the bubble, a long and uniform jet is developed, which advances at a constant velocity until it reaches the receptor substrate. On the other hand, for lower fluences no material is deposited. In this case, although a jet can be also generated, it recoils before reaching the substrate. For higher fluences, splashing is observed on the receptor substrate due to the bursting of the cavitation bubble. Finally, a discussion of the possible mechanisms which lead to such singular dynamics is also provided.

36 MATERIALS SCIENCE↗

Time-resolved imaging of material response during laser-induced bulk damage in SiO2

We report on time resolved imaging of the dynamic events taking place during laser-induced damage in the bulk of fused silica samples with nanosecond temporal resolution and one micron spatial resolution. These events include: shock/pressure wave formation and propagation, transient absorption, crack propagation and formation of residual stress fields. The work has been performed using a time-resolved microscope system that utilizes a probe pulse to acquire images at delay times covering the entire timeline of a damage event. Image information is enhanced using polarized illumination and simultaneously recording the two orthogonal polarization image components. For the case of fused silica, an electronic excitation is first observed accompanied by the onset of a pressure wave generation and propagation. Cracks are seen to form early in the process and reach their final size at about 25 ns into the damage event. In addition, changes that in part are attributed to transient absorption in the modified material are observed for delays up to about 200 microseconds.

42 ENGINEERING↗

Time-resolved imaging of millimeter waves using visible continuum from the positive column of a Cs-Xe dc discharge

We present a high-sensitivity technique for time-resolved imaging of millimeter waves (MMWs) using the visible continuum (VC) from the positive column (PC) of a medium-pressure Cs-Xe dc discharge. For the MMW imaging application, a uniform plasma slab of the PC of a Cs-Xe discharge with 10x8 cm{sup 2} aperture and 2 cm in thickness was generated for 45 Torr xenon. The imaging technique is based on the fact that the intensity of the e-Xe bremsstrahlung continuum from the PC increases in the visible region when the electrons in the plasma are heated by MMWs. It is shown that in the MMW intensity range from zero to the threshold of the microwave-induced plasma breakdown, the intensity of the VC from the PC of a Cs-Xe discharge increases approximately as a second-order polynomial function of the MMW intensity. The obtained experimental data agree well with our calculations of the dependence of the VC intensity on electron temperature. The Ka-band MMW field patterns at the output of conical horn antennas and in the quasioptical beam were imaged using the discharge technique. It is shown that the technique can be used for time-resolved measurement of the profiles of watt- and subwatt-level MMWs. An energy flux sensitivity of the technique of about 10 {mu}J/cm{sup 2} in the Ka-band was demonstrated. The temporal resolution of the technique is about 0.8 {mu}s. Our modeling of the transient behavior of the electron temperature in the PC shows that the time history of the electron temperature variation coincides well with the measured time history of the VC intensity variation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-Resolved Imaging Of Transient Plasma

Pulsed capillary discharge is a compact device that is used to perform fast electrical discharge that is used to produce transient plasma. In this work, a more economical imaging technique is developed in order to study the dynamics of the plasma that is formed in a capillary tube. The imaging system consists of two main devices, a four-frame gated micro-channel plate and a Nikon Coolpix5000 camera. The time-resolved imaging that we have performed in order to study the dynamics of the plasma that is formed in a 10 mm long and 1 mm diameter low pressure capillary tube is reported. The images obtained portrayed that the plasma is heated up when the magnitude of the current is around the maximum and cools down when the current magnitude is around the minimum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved imaging of bound and dissociating nuclear wave packets in strong-field ionized iodomethane

Here, we report the results of a time-resolved coincident ion momentum imaging experiment probing nuclear wave packet dynamics in the strong-field ionization and dissociation of iodomethane (CH 3 I), a prototypical polyatomic system for photochemistry and ultrafast laser science. By measuring yields, kinetic energies, and angular distributions of CH 3 + + I + and CH 3 + + I ++ ion pairs as a function of the delay between two 25 fs, 790 nm pump and probe pulses, we map both, bound and dissociating nuclear wave packets in intermediate cationic states, thereby tracking different ionization and dissociation pathways. In both channels, we find oscillatory features with a 130 fs periodicity resulting from vibrational motion (C–I symmetric stretch mode) in the first electronically excited state of CH 3 I + . This vibrational wave packet dephases within 1 ps, in good agreement with a simple wave packet propagation model. Our results indicate that the first excited cationic state plays a key role in the dissociative ionization of CH 3 I and that it represents an important intermediate in the sequential double and multiple ionization at moderate intensities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments

A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time resolved imaging of magnetization dynamics in hard disk writer yokes excited by bipolar current pulses

A partially built hard disk writer structure with a NiFe/CoFe/Ru/NiFe/CoFe synthetic antiferromagnetic (SAF) yoke was studied by time and vector resolved scanning Kerr microscopy. All three time dependent components of the magnetization were recorded simultaneously as a bipolar current pulse with 1 MHz repetition rate was delivered to the coil. The component of magnetization parallel to the symmetry axis of the yoke was compared at the pole and above a coil winding in the centre of the yoke. The two responses are in phase as the pulse rises, but the pole piece lags the yoke as the pulse falls. The Kerr signal is smaller within the yoke than within the confluence region during pulse cycling. This suggests funneling of flux into the confluence region. Dynamic images acquired at different time delays showed that the relaxation is faster in the centre of the yoke than in the confluence region, perhaps due to the different magnetic anisotropy in these regions. Although the SAF yoke is designed to support a single domain to aid flux conduction, no obvious flux beaming was observed, suggesting the presence of a more complicated domain structure. The SAF yoke writer hence provides relatively poor flux conduction but good control of rise time compared to single layer and multi-layered yokes studied previously.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-Resolved Imaging of Material Response Following Laser-Induced Breakdown in the Bulk and Surface of Fused Silica

Optical components within high energy laser systems are susceptible to laser-induced material modification when the breakdown threshold is exceeded or damage is initiated by pre-existing impurities or defects. These modifications are the result of exposure to extreme conditions involving the generation of high temperatures and pressures and occur on a volumetric scale of the order of a few cubic microns. The response of the material following localized energy deposition, including the timeline of events and the individual processes involved during this timeline, is still largely unknown. In this work, we investigate the events taking place during the entire timeline in both bulk and surface damage in fused silica using a set of time-resolved microscopy systems. These microscope systems offer up to 1 micron spatial resolution when imaging static or dynamic effects, allowing for imaging of the entire process with adequate temporal and spatial resolution. These systems incorporate various pump-probe geometries designed to optimize the sensitivity for detecting individual aspects of the process such as the propagation of shock waves, near-surface material motion, the speed of ejecta, and material transformations. The experimental results indicate that the material response can be separated into distinct phases, some terminating within a few tens of nanoseconds but some extending up to about 100 microseconds. Overall the results demonstrate that the final characteristics of the modified region depend on the material response to the energy deposition and not on the laser parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time resolved imaging of carrier and thermal transport in silicon

We use ultrashort optical pulses to microscopically image carrier and thermal diffusion in two spatial dimensions in pristine and mechanically polished surfaces of crystalline silicon. By decomposing changes in reflectivity in the latter sample into a transient component that varies with delay time and a steady state component that varies with pump chopping frequency, the influence of thermal diffusion is isolated from that of carrier diffusion and recombination. Additionally, studies using carrier injection density as a parameter are used to clearly identify the carrier recombination pathway.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fidelity of a Time-Resolved Imaging Diagnostic for Electron Beam Profiles

An optical tomographic diagnostic instrument has been fielded at the Dual-Axis Radiographic Hydrodynamic Test Facility at Los Alamos National Laboratory. Four optical lines of sight create projections of an image of an electron beam on a Cerenkov target, which are relayed via optical fiber to streak cameras. From these projections, a reconstruction algorithm creates time histories of the beam’s cross section. The instrument was fielded during and after facility commissioning, and tomographic reconstructions reported beam parameters. Results from reconstructions and analysis are noted.

Dual-Axis Radiographic Hydrodynamic Test, DARHT, e↗

A full-field transmission x-ray microscope for time-resolved imaging of magnetic nanostructures

Sub-nanosecond magnetization dynamics of small permalloy (Ni{sub 80}Fe{sub 20}) elements has been investigated with a new full-field transmission microscope at the soft X-ray beamline P04 of the high brilliance synchrotron radiation source PETRA III. The soft X-ray microscope generates a flat-top illumination field of 20 μm diameter using a grating condenser. A tilted nanostructured magnetic sample can be excited by a picosecond electric current pulse via a coplanar waveguide. The transmitted light of the sample plane is directly imaged by a micro zone plate with < 65 nm resolution onto a 2D gateable X-ray detector to select one particular bunch in the storage ring that probes the time evolution of the dynamic information successively via XMCD spectromicroscopy in a pump-probe scheme. In the experiments it was possible to generate a homogeneously magnetized state in patterned magnetic layers by a strong magnetic Oersted field pulse of 200 ps duration and directly observe the recovery to the initial flux-closure vortex patterns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

Time-resolved imaging of electrical discharge development in underwater bubbles

The formation and development of plasma in single air bubbles submerged in water were investigated. The difference in the discharge dynamics and the after-effects on the bubble were investigated using a 900 000 frame per second high-speed charge-coupled device camera. It was observed that depending on the position of the electrodes, the breakdown could be categorized into two modes: (1) direct discharge mode, where the high voltage and ground electrodes were in contact with the bubble, and the streamer would follow the shortest path and propagate along the axis of the bubble and (2) dielectric barrier mode, where the ground electrode was not in touch with the bubble surface, and the streamer would form along the inner surface of the bubble. The oscillation of the bubble and the development of instabilities on the bubble surface were also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

From Shadowgraph to Monochromatic Schlieren: Time-Resolved Imaging of Dim Laser-Induced Phenomena in the Presence of Saturating Plasma Emission

Plasma emission generated during a laser ablation event can saturate an imaging system, washing out valuable information about non-luminous features such as vapor plumes and shock waves. A step-by-step experimental history of development of imaging system from Shadowgraph to Monochromatic Schlieren is presented here as a method of resolving this issue. An ICCD system was used to image ablation events on {mu}s-timescales in combination with a fiber-coupled Nd:YAG laser operating at a primary output of 50 mW at 532 nm wavelength, which was used as the illumination source. A monochromatic band pass filter at 532{+-}10 nm was inserted into the Schlieren system between the focusing lens and the spatial filter, producing a minute shift in the Schlieren focus. With the filter, the saturation effects were eliminated and features such as shock waves and vapor plumes were clearly visible even when plasma was present. Issues with implementation of this system for application to the study of laser propulsion are discussed in detail.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rate-dependent strength and deformation heterogeneity of B4C-reinforced Al composite: Time-resolved imaging with synchrotron X-rays

Dynamic (up to 5500 s -1 ) and quasi-static compression tests are conducted on a 15 wt% B4C particle-reinforced Al (B 4 C/Al) composite. In situ, high-speed synchrotron X-ray phase contrast imaging and digital image correlation are employed to map mesoscale deformation fields at μm and μs scales. The bulk stress–strain curves show significant strain and strain-rate hardening under dynamic compression. The strain-rate sensitivity exponent is an order of magnitude higher at high strain rates (> 10 3 s -1 ) than that at low strain rates (< 10 -2 s -1 ). Strain field mapping demonstrates distinct compressive strain localizations for both quasi-static and dynamic loading. Nevertheless, compressive strain localizations appear denser in spacing under dynamic loading, owing to spontaneous dislocation nucleation in both weak and strong zones. This results in a higher density of geometrically necessary dislocations, which contributes to the higher strain and strain-rate hardening of B 4 C/Al under dynamic loading. Additionally, the ratio of the maximum local strain to the bulk average is 1.5, and the local strain-rate enhancement cannot explain the increased rate sensitivity of B 4 C/Al under dynamic loading. Therefore, the rate-dependent deformation heterogeneity dominates the strain-rate hardening of B 4 C/Al. Postmortem analyses help correlate deformation features to particle- and grain-scale microstructures, yielding consistent results with mesoscale strain fields.

36 MATERIALS SCIENCE↗