Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TiAs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

TIA: A forward model and analyzer for Talbot interferometry experiments of dense plasmas

Interferometry is one of the most sensitive and successful diagnostic methods for plasmas. However, owing to the design of most common interferometric systems, the wavelengths of operation and, therefore, the range of densities and temperatures that can be probed are severely limited. Talbot–Lau interferometry offers the possibility of extending interferometry measurements to x-ray wavelengths by means of the Talbot effect. While there have been several proof-of-concept experiments showing the efficacy of this method, it is only recently that experiments to probe High Energy Density (HED) plasmas using Talbot–Lau interferometry are starting to take place. To improve these experimental designs, we present here the Talbot-Interferometry Analyzer (TIA) tool, a forward model for generating and postprocessing synthetic x-ray interferometry images from a Talbot–Lau interferometer. Although TIA can work with any two-dimensional hydrodynamic code to study plasma conditions as close to reality as possible, this software has been designed to work by default with output files from the hydrodynamic code FLASH, making the tool user-friendly and accessible to the general plasma physics community. Here, the model has been built into a standalone app, which can be installed by anyone with access to the MATLAB runtime installer and is available upon request to the authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TIA Software User's Manual

This user's manual describes the installation and operation of TIA, the Thermal-Imaging acquisition and processing Application, developed by the Nondestructive Evaluation Sciences Branch at NASA Langley Research Center, Hampton, Virginia. TIA is a user friendly graphical interface application for the Macintosh 2 and higher series computers. The software has been developed to interface with the Perceptics/Westinghouse Pixelpipe(TM) and PixelStore(TM) NuBus cards and the GW Instruments MacADIOS(TM) input-output (I/O) card for the Macintosh for imaging thermal data. The software is also capable of performing generic image-processing functions.

Cramer, K. Elliott↗

Materials Data on TiAs by Materials Project

TiAs is Molybdenum Carbide MAX Phase-like structured and crystallizes in the hexagonal P6_3/mmc space group. The structure is three-dimensional. Ti3+ is bonded to six equivalent As3- atoms to form a mixture of distorted corner and edge-sharing TiAs6 pentagonal pyramids. All Ti–As bond lengths are 2.61 Å. As3- is bonded to six equivalent Ti3+ atoms to form a mixture of corner, edge, and face-sharing AsTi6 octahedra. The corner-sharing octahedral tilt angles are 47°.

36 MATERIALS SCIENCE↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and Validation of Offset Cancellation for Hybrid Photonic-Electronic Transimpedance Amplifier Using All-Electronic Circuits

Hybrid photonic-electronic circuits involving crossdomain feedback signals are difficult to validate and troubleshoot. This paper describes an approach to model and validate an offset-cancellation loop for a hybrid transimpedance amplifier (TIA) using all-electronic circuits. An equivalent electrical model is developed for the tunable interferometer attenuators used for offset trimming, and it includes test features to extract the system performance. The stability analysis of the system shows 75 ◦ of phase margin and 102 dB of gain margin. Measurement results demonstrate good agreement with analysis and successful TIA offset cancellation.

Marchant, Jared↗

Sensitive method for characterizing liquid helium cooled preamplifier feedback resistors

It is pointed out that the simple and traditional method of measuring resistance using an electrometer is ineffective since it is limited to a narrow and nonrepresentative range of terminal voltages. The present investigation is concerned with a resistor measurement technique which was developed to select and calibrate the Transimpedance Mode Amplifier (TIA) load resistors on the Infrared Astronomical Satellite (IRAS) for the wide variety of time and voltage varying signals which will be processed during the flight. The developed method has great versatility and power, and makes it possible to measure the varied and complex responses of nonideal feedback resistors to IR photo-detector currents. When employed with a stable input coupling capacitor, and a narrow band RMS voltmeter, the five input waveforms thouroughly test and calibrate all the features of interest in a load resistor and its associated TIA circuitry.

Smeins, L. G.↗

Cooled grating infrared spectrometer for astronomical observations

A liquid helium-cooled infrared spectrometer for the 16 to 50 micron range is described. The instrument has six detectors, three each of Si:Sb and Ge:Ga and two diffraction gratings mounted back-to-back. Cold preoptics are used to match the spectrometer to the telescope. In its nominal configuration the system resolution is 0.03 micron from 16 to 30 microns and 0.07 micron from 28 to 50 microns. A cooled filter wheel is used to change order sorting filters. The gratings are driven by a steel band and gear train operating at 4 K. The detector outputs are amplified by a TIA, employing a matched pair of JFETs operating at 70 K inside the dewar. The external warm electronics include a gain stage for the TIA and dc-coupled gating circuit to remove charged-particle (cosmic-ray secondary)-induced noise spikes. The gating circuit reduces the overall system noise by a factor of two when the spectrometer is used on NASA's Kuiper Airborne Observatory. Sample spectra are presented and the deglitcher performance is illustrated.

Houck, J. R.↗

Infrared and visible detector electronics for the Infrared Astronomical Satellite (IRAS)

The paper describes the detectors, preamplifiers, and processing electronics; the system characterization test methods and results; and the performance of the detectors and electronics during the first month of on-orbit operation of the IRAS telescope. The Focal Plane Array (FPA) consists of 62 IR channels and 8 visible channels operating at 2.5 K. The IR detectors are grouped in eight 7 or 8 channel staggered linear subarrays with shared bias voltage; the visible detectors are grouped in two 4 channel skewed arrays, also with shared bias. Each channel detector is dc coupled to a TIA preamplifier through a very low power thermally isolated JFET source follower operating at about 65 K within the FPA housing. The visible channel detectors are ac coupled to TIA preamplifiers and signal chain electronics using MOSFET source followers operating at about 2.5 K within the FPA housing. The detectors, preamplifiers, analog electronics, and grounding are discussed as they evolved and were implemented during FPA retrofit, telescope integration, and preparation for launch.

Langford, D. L.↗

Manned Mars System Study (MMSS): Mars transportation and facility infrastructure study. Volume 2: Technical report

The Manned Mars System Study (MMSS) was conducted for the Marshall Space Flight Center (MSFC) over the 35 month period between May 15, 1987 and April 30, 1990. During the course of the study, the NASA Office of Exploration (OEXP; Code Z) was created and MSFC was subsequently designated the Transportation Integration Agent (TIA) for support of the OEXP Mission Analysis and Systems Engineering (MASE) team. As a result of this action, modifications to the contract redirected the efforts to be consistent with NASA's overall objectives, including lunar transportation system design. A large number of written submittals were required in order to provide TIA support to MASE. A list summarizing the documents which have been prepared and delivered by Martin Marietta under this contract during the course of this work is presented. In nearly all cases, full sets of view-graphs were also provided to the MSFC COTR, and in several cases magnetic media were provided as well. To incorporate all of these materials (more than 2,000 pages) into the present report would obviously produce an extremely unwieldy and confusing document. Therefore, a summary of key findings are presented in this final report, supplemented by other material produced under this contract but not already available in the widespread literature.

Source record↗

HYMOSS signal processing for pushbroom spectral imaging

The objective of the Pushbroom Spectral Imaging Program was to develop on-focal plane electronics which compensate for detector array non-uniformities. The approach taken was to implement a simple two point calibration algorithm on focal plane which allows for offset and linear gain correction. The key on focal plane features which made this technique feasible was the use of a high quality transimpedance amplifier (TIA) and an analog-to-digital converter for each detector channel. Gain compensation is accomplished by varying the feedback capacitance of the integrate and dump TIA. Offset correction is performed by storing offsets in a special on focal plane offset register and digitally subtracting the offsets from the readout data during the multiplexing operation. A custom integrated circuit was designed, fabricated, and tested on this program which proved that nonuniformity compensated, analog-to-digital converting circuits may be used to read out infrared detectors. Irvine Sensors Corporation (ISC) successfully demonstrated the following innovative on-focal-plane functions that allow for correction of detector non-uniformities. Most of the circuit functions demonstrated on this program are finding their way onto future IC's because of their impact on reduced downstream processing, increased focal plane performance, simplified focal plane control, reduced number of dewar connections, as well as the noise immunity of a digital interface dewar. The potential commercial applications for this integrated circuit are primarily in imaging systems. These imaging systems may be used for: security monitoring systems, manufacturing process monitoring, robotics, and for spectral imaging when used in analytical instrumentation.

Ludwig, David E.↗

The Incidence of Patent Foramen Ovale in 1,000 Consecutive Patients: A Contrast Transesophageal Echocardiography Study

Study objective: Patent foramen ovale (PFO) is present in 10 to 35% of people and has been reported to be an important risk factor for cardioembolic cerebrovascular accidents (CVAs) and transient ischemic attacks (TIAS), especially in younger patients. While contrast transthoracic echocardiography has been used to detect PFO, contrast transesophageal echocardiography (TEE) has a greater sensitivity. Prior studies reported the incidence of PFO in patients presenting with a CVA or TIA. Design: To determine the incidence of PFO in a more general population, we reviewed 1,000 consecutive TEES performed with contrast and color Doppler for the presence of PFO and other cardioembolic risk factors, including atrial septal aneurysm (ASA), aortic plaque, atrial fibrillation (AFib), and atrial thrombi. While imaging with monoplane or biplane TEE, multiple injections of agitated saline solution were injected during cough or Valsalva maneuver to detect flow through a PFO. Patients: There were 482 male and 518 female patients with mean age of 60 + 17 years (range 11 to 93 years). Results: Patent foramen ovale was found in 9.2% of all patients and, though seen in all age groups divided by decade, the incidence in patients aged 40 to 49 years was greater than those aged 70 to 79 years (12.96% vs 6.15%',, p=0.03). Contrast TEE had a much higher detection rate than color Doppler alone. Importantly, there was no greater incidence of PFO in patients with CVA vs thos~ without CVA, or in male vs female patients. Also, there was a very strong correlation between the presence of ASA and PFO (p<.001). Conclusion: Thus, PFO detected by TEE, frequently seen with ASA, is seen in all age groups and does not in itself present a risk factor for CVA. The association of PFO with peripheral thrombosis and CVA needs further study.

Fisher, Daniel C.↗

Improved-Bandwidth Transimpedance Amplifier

The widest available operational amplifier, with the best voltage and current noise characteristics, is considered for transimpedance amplifier (TIA) applications where wide bandwidth is required to handle fast rising input signals (as for time-of-flight measurement cases). The added amplifier inside the TIA feedback loop can be configured to have slightly lower voltage gain than the bandwidth reduction factor.

Chapsky, Jacob↗

Comprehensive Radiation Testing of Uncooled, Free Space Coupled, InGaAs Quad Photoreceivers

We have comprehensively tested uncooled, free space coupled, InGaAs Quad Photoreceivers having 0.5mm, 1mm, and 2mm diameter integrated with a low noise transimpedance amplifier (TIA)using 30MeV Protons, 100MeV Protons, 662keV Gamma Rays, 1GeV/n Helium, and 1GeV/n Iron at room temperature of ~20°C.These devices find multiple applications in space for differential wave front sensing as part of a Gravitational Wave Observatory, as well as instrumentation and control for next generation space telescopes. The bandwidth of all receivers was 20MHz which was TIA limited. All 0.5mm and 1mm devices were found to be fully functional at normal operating conditions and at room temperature for Protons, Gamma Rays, 1GeV/n Helium, and 1GeV/n Iron. Only one quadrant of a 2mm In GaAs Quad had hard failure due to 1GeV/n Helium Ions; otherwise it too survived all other radiation tests. Detailed test results follow in the manuscript including recommendations for future space flights. These radiation test results, combined with the earlier successful mechanical shock and vibration testing mean these devices have passed preliminary testing for space qualification.

Abhay M Joshi↗

Reflective Fiber Temperature Probe Based on Localized Surface Plasmon Resonance towards Low-Cost and Wireless Interrogation

Reflection fiber temperature sensors functionalized with plasmonic nanocomposite material using intensity-based modulation are demonstrated for the first time. Characteristic temperature optical response of the reflective fiber sensor is experimentally tested using Au-incorporated nanocomposite thin films deposited on the fiber tip, and theoretically validated using a thin-film-optic-based optical waveguide model. By optimizing the Au concentration in a dielectric matrix, Au nanoparticles (NP) exhibit a localized surface plasmon resonance (LSPR) absorption band in a visible wavelength that shows a temperature sensitivity ~0.025%/°C as a result of electron–electron and electron–phonon scattering of Au NP and the surrounding matrix. Detailed optical material properties of the on-fiber sensor film are characterized using scanning electron microscopy (SEM) and focused-ion beam (FIB)-assisted transmission electron microscopy (TEM). Airy’s expression of transmission and reflection using complex optical constants of layered media is used to model the reflective optical waveguide. A low-cost wireless interrogator based on a photodiode transimpedance-amplifier (TIA) circuit with a low-pass filter is designed to integrate with the sensor. The converted analog voltage is wirelessly transmitted via 2.4 GHz Serial Peripheral Interface (SPI) protocols. Feasibility is demonstrated for portable, remotely interrogated next-generation fiber optic temperature sensors with future capability for monitoring additional parameters of interest.

47 OTHER INSTRUMENTATION↗

Quantile-dependent expressivity of serum C-reactive protein concentrations in family sets

“Quantile-dependent expressivity” occurs when the effect size of a genetic variant depends upon whether the phenotype (e.g., C-reactive protein, CRP) is high or low relative to its distribution. We have previously shown that the heritabilities ( h 2 ) of coffee and alcohol consumption, postprandial lipemia, lipoproteins, leptin, adiponectin, adiposity, and pulmonary function are quantile-specific. Whether CRP heritability is quantile-specific is currently unknown. Methods Serum CRP concentrations from 2,036 sibships and 6,144 offspring-parent pairs were analyzed from the Framingham Heart Study. Quantile-specific heritability from full-sib (β FS , h 2 ={(1 + 8r spouse β FS ) 0.5 - 1}/(2r spouse )) and offspring-parent regression slopes (β OP , h 2 = 2β OP /(1 + r spouse )) were estimated robustly by quantile regression with nonparametric significance determined from 1,000 bootstrap samples. Results Quantile-specific h 2 (±SE) increased with increasing percentiles of the offspring’s age- and sex-adjusted CRP distribution when estimated from β OP ( P trend = 0.0004): 0.02 ± 0.01 at the 10th, 0.04 ± 0.01 at the 25th, 0.10 ± 0.02 at the 50th, 0.20 ± 0.05 at the 75th, and 0.33 ± 0.10 at the 90th percentile, and when estimated from β FS ( P trend = 0.0008): 0.03±0.01 at the 10th, 0.06 ± 0.02 at the 25th, 0.14 ± 0.03 at the 50th, 0.24 ± 0.05 at the 75th, and 0.53 ± 0.21 at the 90th percentile. Conclusion Heritability of serum CRP concentration is quantile-specific, which may explain or contribute to the inflated CRP differences between CRP (rs1130864, rs1205, rs1800947, rs2794521, rs3091244), FGB (rs1800787), IL-6 (rs1800795, rs1800796), IL6R (rs8192284), TNF- α (rs1800629) and APOE genotypes following CABG surgery, stroke, TIA, curative esophagectomy, intensive periodontal therapy, or acute exercise; during acute coronary syndrome or Staphylococcus aureus bacteremia; or in patients with chronic rheumatoid arthritis, diabetes, peripheral arterial disease, ankylosing spondylitis, obesity or inflammatory bowel disease or who smoke.

59 BASIC BIOLOGICAL SCIENCES↗

Tests of low background photo conductors

In support of two infrared astronomy space projects, the IRAS satellite and the IRT on Spacelab 2, low-background tests were carried out on the performance and characterization of Si:Ga, Si:As, Si:Sb and Ge:Ga photoconductive detectors. These test results represent a useful appraisal of this family of detectors when operated at 1.8-4.2 K and at background power levels of 10 to the -14th to 10 to the -13th W. In addition to detector performance data, results are also presented on cryogenically cooled MOSFET amplifiers operated in the source follower and in the balanced-dc-TIA configurations.

Young, E. T.↗

Characterization of feedback resistors for cryogenic applications

Results are presented on the testing of feedback resistors selected for use in the transimpedance amplifiers (TIAs) in the Diffuse Infrared Background Experiment (DIRBE) to be flown on the NASA's Cosmic Background Explorer satellite planned for a launch in 1989. The resistors without encapsulation were found to be reliable as cryogenic circuit elements. Their resistance is sufficiently high (so that their Johnson noise does not dominate amplifier noise at the signal frequency), and they are sufficiently linear; no correction need to be made for signals up to 1.5 V, the 100,000 signal-to-noise level for the DIRBE, which covers most of the signals expected to be seen on the sky.

Lakew, B.↗

Issues in PCS interoperability and Internetworking

This paper is an expansion of an earlier paper on Satellite/Terrestrial PCS which addressed issues for interoperability that included Networks, Services, Voice Coders and Mobility/Security. This paper focuses on the narrower topic of Network Reference Models and associated interfaces and protocols. The network reference models are addressed from the perspective of the User, the Cellular Carrier, the PSN Carrier, and the Radio Vendor. Each perspective is presented in the way these systems have evolved. The TIA TR46/GSM reference model will be reviewed. Variations in the use of this model that are prevalent in the industry will be discussed. These are the North American Cellular networks, the GSM networks, and the North American Carriers/Bellcore perspective. The paper concludes with the presentation of issues that develop from looking at merging satellite service into a world of many different networks.

Dean, Richard A.↗