Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermocouple”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Summary of Thermocouple Performance During Advanced Gas Reactor Fuel Irradiation Experiments in the Advanced Test Reactor and Out-of-Pile Thermocouple Testing in Support of Such Experiments

High temperature gas reactor experiments create unique challenges for thermocouple based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B); and tungsten-rhenium thermocouples (Types C and W). For lower temperature applications, previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of these Nickel based thermocouples is limited when the temperature exceeds 1000°C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past ten years, three long-term Advanced Gas Reactor (AGR) experiments have been conducted with measured temperatures ranging from 700oC – 1200oC. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out of pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150oC and 1200oC for 2000 hours at each temperature, followed by 200 hours at 1250oC, and 200 hours at 1300oC. The standard Type N design utilizes high purity crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including Haynes 214 alloy sheath, spinel (MgAl2O4) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly thermocouple with hard fired alumina insulation and molybdenum sheath. The most current version of the High Temperature Irradiation Resistant Thermocouple (HTIR-TC) based on molybdenum/niobium alloys, and developed at Idaho National Laboratory, was also tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of thermocouple performance during advanced gas reactor fuel irradiation experiments in the advanced test reactor and out-of-pile thermocouple testing in support of such experiments

High temperature gas reactor experiments create unique challenges for thermocouple-based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time-dependent change in composition and, as a consequence, a time-dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C). For lower temperature applications, previous experiences with Type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly, Type N thermocouples are expected to be only slightly affected by neutron fluence. Currently, the use of these nickel-based thermocouples is limited when the temperature exceeds 1000 deg. C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past 10 years, three long-term Advanced Gas Reactor experiments have been conducted with measured temperatures ranging from 700 deg. C - 1200 deg. C. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out-of-pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150 deg. C and 1200 deg. C for 2,000 hours at each temperature, followed by 200 hours at 1250 deg. C and 200 hours at 1300 deg. C. The standard Type N design utilizes high purity, crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including a Haynes 214 alloy sheath, spinel (MgAl{sub 2}O{sub 4}) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly thermocouple with hard-fired alumina insulation and a molybdenum sheath. The most current version of the High Temperature Irradiation Resistant Thermocouple, based on molybdenum/niobium alloys and developed at Idaho National Laboratory, was also tested. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High Temperature Irradiation Resistant Thermocouple Drift Model Application to Commercial Thermocouples

The Advance Sensors and Instrumentation fiscal year report on the direct application of the HTIR-TC drift model on other commercial thermocouples. The Type N and K thermocouples are useful in irradiation environments up to 1100°C (or 1290°C for short bursts and/or single use), but over temperature and high fluence can cause the TCs to drift. The HTIR-TC drift model predicts the end use environment of temperature and irradiation and the total time scale to show the amount of drift a thermocouple will undergo. The model predicts that HTIR-TCs at full temperature range and fluence of 10^21 N/cm^2 will exhibit a drift of under -1%. The type N and K TCs will see a drift of -0.5% at the same fluence, but temperatures below 1100°C. Above this temperature the Type N and K TCs quickly de-calibrate and will give erroneous temperatures measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-temperature, irradiation-resistant thermocouple, coaxial thermocouple, and related methods

A coaxial thermocouple includes a wire, an insulation layer surrounding the wire, a sheath surrounding the insulation layer, and an electrical junction formed between the wire and the sheath and at one longitudinal end of the coaxial thermocouple, the electrical junction including a swaged end with an outer diameter of the sheath reducing in diameter along a longitudinal length of the coaxial thermocouple until the sheath contacts the wire within the insulation layer. The wire includes a first material and the sheath includes a second material where the first material includes one of molybdenum (Mo) or niobium (Nb) and the second material includes the other of molybdenum (Mo) or niobium (Nb).

Skifton, Richard S.↗

Optimization of heat treatment and calibration procedures for high temperature irradiation resistant thermocouples [The development of calibration procedures for high temperature irradiation resistant thermocouples]

Here, a detailed description is provided for the optimization of heat treatment and calibrating procedure for Idaho National Laboratory’s high temperature irradiation resistant thermocouples (HTIR-TC). Also discussed is the implication of the procedures on the overall performance of the HTIR-TC finished product; in particular, for the case of long lead sections that are typical of sensors deployed in nuclear reactors. The effect on the measurement accuracy of fluctuations of the reference temperature and localized heating along the sensor lead is also investigated. A calibration graphical user interface (GUI) and accompanying script is presented for unifying the calibration process. A fifth-order polynomial function was found to be best for fitting HTIR-TC calibration data. The performance of the HTIR-TCs subject to the optimized heat treatment and calibration procedures is shown to be robust and consistent with other TC industry standards. Electromotive force curves versus length of the TC are presented to clarify positioning of TCs in general and how its effect on the calibrated temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low drift type N thermocouples in out-of-pile advanced gas reactor mock-up test: metallurgical analysis

Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. As part of a collaboration between Idaho National Laboratory (INL) and the University of Cambridge a variety of Type N thermocouples have been exposed at INL in an Advanced Gas Reactor mock-up test at 1150 deg. C for 2000 h, 1200 deg. C for 2000 h, 125 deg. C for 200 h and 1300 deg. C for 200 h, and later analysed metallurgically at the University of Cambridge. The use of electron microscopy allows to identify the metallurgical changes occurring in the thermocouples during high temperature exposure and correlate the time dependent thermocouple drift with the microscopic changes experienced by the thermoelements of different thermocouple designs. In this paper conventional Inconel 600 sheathed type N thermocouples and a type N using a customized sheath developed at the University of Cambridge have been investigated. The rationale for the superior performance of the type N using a customized sheath developed at the University of Cambridge is explained in comparison with the behavior of conventional type N Inconel 600 sheathed thermocouples. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Summary of Thermocouple Performance in the Advanced Gas Reactor Experiment AGR-5/6/7 During Irradiation in the Advanced Test Reactor

The Advanced Gas Reactor -5/6/7 (AGR-5/6/7) experiment was the fourth and final experiment in the AGR experiment series and completed irradiation in July 2020. It serves as the formal fuel qualification test for the TRISO fuels under development by the US Department of Energy. This experiment was designed to irradiate fuel particles at temperatures ranging from 800°C ? 1500°C. The high end of the range created unique challenges for thermocouple-based temperature measurements. Commercially available high-temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C) suffer rapid decalibration due to transmutation of the thermoelements from neutron absorption. A special low neutron cross-section thermocouple system based on molybdenum/niobium thermoelements called High Temperature Irradiation Resistant thermocouple (HTIR-TC) has been under development at INL since circa 2004. Several examples of this thermocouple type were incorporated into regions of the test operating above 1200°C. For regions in the test operating in the 1000°C ? 1200°C range, high-performance versions of Type N thermocouples recently developed at Cambridge University were installed. Standard Type N thermocouples were used in regions of the test operating below 1000°C. A total of 54 thermocouples were incorporated into the test. A report of the performance of this large heterogenous set of thermocouples over the first third of the irradiation was previously provided (ANIMMA 2019). This follow-on paper discusses results from the balance of the experiment (Feb 2019 - July 2020). Special attention is focused on potential drift of thermocouples operating in the higher temperature regions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of Thermocouple Performance in the Advanced Gas Reactor Experiment AGR-5/6/7 During Irradiation in the Advanced Test Reactor

This is a conference presentation ppt file. The following abstract is for the entire conference paper - which will later be the subject of a PRS artifact The Advanced Gas Reactor -5/6/7 (AGR-5/6/7) experiment was the fourth and final experiment in the AGR experiment series and completed irradiation in July 2020. It serves as the formal fuel qualification test for the TRISO fuels under development by the US Department of Energy. This experiment was designed to irradiate fuel particles at temperatures ranging from 800°C ? 1500°C. The high end of the range created unique challenges for thermocouple-based temperature measurements. Commercially available high-temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C) suffer rapid decalibration due to transmutation of the thermoelements from neutron absorption. A special low neutron cross-section thermocouple system based on molybdenum/niobium thermoelements called High Temperature Irradiation Resistant thermocouple (HTIR-TC) has been under development at INL since circa 2004. Several examples of this thermocouple type were incorporated into regions of the test operating above 1200°C. For regions in the test operating in the 1000°C ? 1200°C range, high-performance versions of Type N thermocouples recently developed at Cambridge University were installed. Standard Type N thermocouples were used in regions of the test operating below 1000°C. A total of 54 thermocouples were incorporated into the test. A report of the performance of this large heterogenous set of thermocouples over the first third of the irradiation was previously provided (ANIMMA 2019). This follow-on paper discusses results from the balance of the experiment (Feb 2019 - July 2020). Special attention is focused on potential drift of thermocouples operating in the higher temperature regions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Test Results of Thermocouples Used in the TRISO-Fuel Irradiation Experiment AGR-5/6/7

High-temperature gas reactor irradiation experiments create unique challenges for thermocouple-based temperature measurements. High-temperature industrial thermocouples suffer rapid decalibration due to transmutation of the thermoelements from neutron absorption. For lower-temperature applications, Type K and Type N thermocouples are affected by neutron irradiation only to a limited extent. But until recently, the use of these nickel-based thermocouples was limited when the temperature exceeded 1050°C due to drift related to phenomena other than nuclear irradiation. Certain portions of the AGR-5/6/7 experiment experienced temperatures higher than any of the previous AGR tests, up to 1500°C. Recognizing the limitations of existing thermometry to measure such high temperatures, the sponsor of the AGR-5/6/7 test supported a development and testing program for thermocouples capable of low-drift operation at temperatures above 1100°C. This program included additional development of high-temperature irradiation-resistant thermocouples based on molybdenum/niobium thermoelements, which have been studied at Idaho National Laboratory since circa 2004. A step change in accuracy and long-term stability of this thermocouple type was achieved as part of the AGR-5/6/7 thermometry development program. Additionally, long-term testing (7000+ h) at 1250°C of Type N thermocouples utilizing a customized sheath developed at the University of Cambridge has been completed with excellent low-drift results. The results of this testing as well as testing of the improved high-temperature irradiation-resistant design are reported herein. Both the improved high-temperature irradiation-resistant and the Cambridge Type N thermocouple types were incorporated into the AGR-5/6/7 test, which began irradiation in February 2018 and was completed in July 2020. Finally, a summary of the performance of the thermocouples incorporated into the AGR-5/6/7 test is included herein.

In-pile instrumentation↗

Thermocouple shield

A thermocouple shield for use in radio frequency fields. In some embodiments the shield includes an electrically conductive tube that houses a standard thermocouple having a thermocouple junction. The electrically conductive tube protects the thermocouple from damage by an RF (including microwave) field and mitigates erroneous temperature readings due to the microwave or RF field. The thermocouple may be surrounded by a ceramic sheath to further protect the thermocouple. The ceramic sheath is generally formed from a material that is transparent to the wavelength of the microwave or RF energy. The microwave transparency property precludes heating of the ceramic sheath due to microwave coupling, which could affect the accuracy of temperature measurements. The ceramic sheath material is typically an electrically insulating material. The electrically insulative properties of the ceramic sheath help avert electrical arcing, which could damage the thermocouple junction. The electrically conductive tube is generally disposed around the thermocouple junction and disposed around at least a portion of the ceramic sheath. The concepts of the thermocouple shield may be incorporated into an integrated shielded thermocouple assembly.

42 ENGINEERING↗

Fabrication and Thermoelectric Characterization of Transition Metal Silicide-Based Composite Thermocouples

Metal silicide-based thermocouples were fabricated by screen printing thick films of the powder compositions onto alumina tapes followed by lamination and sintering processes. The legs of the embedded thermocouples were composed of composite compositions consisting of MoSi2, WSi2, ZrSi2, or TaSi2 with an additional 10 vol % Al2O3 to form a silicide–oxide composite. The structural and high-temperature thermoelectric properties of the composite thermocouples were examined using X-ray diffraction, scanning electron microscopy and a typical hot–cold junction measurement technique. MoSi2-Al2O3 and WSi2-Al2O3 composites exhibited higher intrinsic Seebeck coefficients (22.2–30.0 µV/K) at high-temperature gradients, which were calculated from the thermoelectric data of composite//Pt thermocouples. The composite thermocouples generated a thermoelectric voltage up to 16.0 mV at high-temperature gradients. The MoSi2-Al2O3//TaSi2-Al2O3 thermocouple displayed a better performance at high temperatures. The Seebeck coefficients of composite thermocouples were found to range between 20.9 and 73.0 µV/K at a temperature gradient of 1000 °C. There was a significant difference between the calculated and measured Seebeck coefficients of these thermocouples, which indicated the significant influence of secondary silicide phases (e.g., Mo5Si3, Ta5Si3) and possible local compositional changes on the overall thermoelectric response. The thermoelectric performance, high sensitivity, and cost efficiency of metal silicide–alumina ceramic composite thermocouples showed promise for high-temperature and harsh-environment sensing applications.

47 OTHER INSTRUMENTATION↗

Problems Encountered in Fluctuating Flame Temperature Measurements by Thermocouple

Some thermocouple experiments were carried out in order to obtain sensitivity of thermocouple readings to fluctuations in flames and to determine if the average thermocouple reading was representative of the local volume temperature for fluctuating flames. The thermocouples considered were an exposed junction thermocouple and a fully sheathed thermocouple with comparable time constants. Either the voltage signal or indicated temperature for each test was recorded at sampling rates between 300-4,096 Hz. The trace was then plotted with respect to time or sample number so that time variation in voltage or temperature could be visualized and the average indicated temperature could be determined. For experiments where high sampling rates were used, the signal was analyzed using Fast Fourier Transforms (FFT) to determine the frequencies present in the thermocouple signal. This provided a basic observable as to whether or not the probe was able to follow flame oscillations. To enhance oscillations, for some experiments, the flame was forced. An analysis based on thermocouple time constant, coupled with the transfer function for a sinusoidal input was tested against the experimental results.

Thermocouple transfer function↗

Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

During irradiation tests at high temperature, failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. To understand and remedy this problem, out-of-pile tests were performed with thermocouples in carburizing atmospheres which can be assumed to be at least locally representative for High Temperature Reactors. The objective was to screen those thermocouples which would consecutively be used under irradiation. Two such screening tests have been performed with a set of thermocouples embedded in graphite (mainly conventional Type N thermocouples and thermocouples with innovative sheaths) in a dedicated furnace with helium flushing. Performance indicators such as thermal drift, insulation and loop resistance were monitored and compared to those from conventional Type N thermocouples. Several parameters were investigated: niobium sleeves, bending, thickness, sheath composition, temperature as well as the chemical environment. After the tests, Scanning Electron Microscopy (SEM) examinations were performed to analyze possible local damage in wires and in the sheath. The present paper describes the two experiments, summarizes results and outlines further work, in particular to further analyze the findings and to select suitable thermocouples for qualification under irradiation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗