Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Thermal protection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Flight set 360L007 (STS-33R) field joint protection system, thermal protection system, and systems tunnel components, volume 7

The performance of the thermal protection system, field joint protection system, and systems tunnel components of flight set 360L007 is presented as evaluated by postflight hardware inspection. The condition of both motors was similar to previous flights. Four aft edge strikes were noted on the ground environment instrumentation thermal protection system. The hits all left a clean substrate, indicating that the damage was caused by nozzle severance debris and/or water impact. No National Space Transportation System debris criteria for missing thermal protection system were violated. Two problem reports were written against the field joint protection system. The first concerned two cracks in the K5NA closeout over the trunnion/vent valve location on the left-hand aft field joint. A similar condition was observed on Flight 5 (360H005). The second problem report referred to a number of small surface cracks between two impact marks on the left-hand forward field joint. Neither area exhibited loose material or any abnormal heat effects, and they have no impact on flight safety.

Source record

Flight Set 360L006 STS-34 field joint protection system, thermal protection system, and systems tunnel components, volume 4

The performance of the thermal protection system, field joint protection system, and systems tunnel components of Flight Set 360L006, are documented, as evaluated by postflight hardware inspection. The condition of both motors was similar to previous flights. Sixteen aft edge hits were noted on the ground environment instrumentation thermal protection system. Each hit left a clean substrate, indicating that the damage was caused by nozzle severance debris and/or water impact. No National Space and Transporation System debris criteria for missing thermal protection system were violated. One 5.0 by 1.0 in. unbond was observed on the left hand center field joint K5NA closeout and was elevated to an in-flight anomaly (STS-34-M-4) by the NASA Ice/Debris team. Aft edge damage to the K5NA and an associated black streak indicate that burning debris from the nozzle severance system was the likely cause of the damage. Minor divots caused by debris were seen on previous flights, but this is the first occurrence of a K5NA unbond. Since the unbond occurred after booster separation there is no impact on flight safety and no corrective actions was taken. The right hand center field joint primary heater failed the dielectric withstanding voltage test after joint closeout. The heater was then disabled by opening the circuit breaker, and the redundant heater was used. The redundant heater performed nominally during the launch countdown. A similar condition occurred on Flight 4 when a secondary joint heater failed the dielectric withstanding voltage test.

Wilkinson, J. P.

Feasibility of Additive Manufacturing for Thermal Protection Systems

Thermal Protection Systems (TPS) use advanced materials to protect vehicles from aerodynamic heating during atmospheric entry. Manufacturing of these composite materials is often very time consuming and labor-intensive. Leveraging the additive manufacturing FDM (Fused Deposition Modeling) process enables NASA to design and manufacture advanced ablative TPS materials while reducing manufacturing time and cost. Since additive manufacturing is an automated process, it ensures part consistency over the entire heat shield area. The purpose for this presentation will be three-fold. 1) Introduce novel low-density ablative materials capable of utilizing additive manufacturing capabilities 2) show feasibility of additively manufacturing TPS coupons using the downselected TPS materials 3) Side by side comparison of high temperature test results for printable paste and state of the art low-density ablators

T. Boghozian

Estimates Of The Orbiter RSI Thermal Protection System Thermal Reliability

In support of the Space Shuttle Orbiter post-flight inspection, structure temperatures are recorded at selected positions on the windward, leeward, starboard and port surfaces. Statistical analysis of this flight data and a non-dimensional load interference (NDLI) method are used to estimate the thermal reliability at positions were reusable surface insulation (RSI) is installed. In this analysis, structure temperatures that exceed the design limit define the critical failure mode. At thirty-three positions the RSI thermal reliability is greater than 0.999999 for the missions studied. This is not the overall system level reliability of the thermal protection system installed on an Orbiter. The results from two Orbiters, OV-102 and OV-105, are in good agreement. The original RSI designs on the OV-102 Orbital Maneuvering System pods, which had low reliability, were significantly improved on OV-105. The NDLI method was also used to estimate thermal reliability from an assessment of TPS uncertainties that was completed shortly before the first Orbiter flight. Results fiom the flight data analysis and the pre-flight assessment agree at several positions near each other. The NDLI method is also effective for optimizing RSI designs to provide uniform thermal reliability on the acreage surface of reusable launch vehicles.

Kolodziej, P.

Design, development and test of shuttle/Centaur G-prime cryogenic tankage thermal protection systems

The thermal protection systems for the shuttle/Centaur would have had to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort. The thermal protection systems selected used a helium-purged polyimide foam beneath three rediation shields for the liquid-hydrogen tank and radiation shields only for the liquid-oxygen tank (three shields on the tank sidewall and four on the aft bulkhead). A double-walled vacuum bulkhead separated the two tanks. The liquid-hydrogen tank had one 0.75-in-thick layer of foam on the forward bulkhead and two layers on the larger area sidewall. Full scale tests of the flight vehicle in a simulated shuttle cargo bay that was purged with gaseous nitrogen gave total prelaunch heating rates of 88,500 Btu/hr and 44,000 Btu/hr for the liquid-hydrogen and -oxygen tanks, respectively. Calorimeter tests on a representative sample of the liquid-hydrogen tank sidewall thermal protection system indicated that the measured unit heating rate would rapidly decrease from the prelaunch rate of approx 100 Btu/hr/sq ft to a desired rate of less than 1.3 Btu/hr/sq ft once on orbit.

Knoll, Richard H.

Ablation Modeling of Ares-I Upper State Thermal Protection System Using Thermal Desktop

The thermal protection system (TPS) for the Ares-I Upper Stage will be based on Space Transportation System External Tank (ET) and Solid Rocket Booster (SRB) heritage materials. These TPS materials were qualified via hot gas testing that simulated ascent and re-entry aerothermodynamic convective heating environments. From this data, the recession rates due to ablation were characterized and used in thermal modeling for sizing the thickness required to maintain structural substrate temperatures. At Marshall Space Flight Center (MSFC), the in-house code ABL is currently used to predict TPS ablation and substrate temperatures as a FORTRAN application integrated within SINDA/G. This paper describes a comparison of the new ablation utility in Thermal Desktop and SINDA/FLUINT with the heritage ABL code and empirical test data which serves as the validation of the Thermal Desktop software for use on the design of the Ares-I Upper Stage project.

Sharp, John R.

Structural characteristics of the shuttle orbiter ceramic thermal protection system

The thermal protection system (TPS) of the Space Shuttle Orbiter is described as well as the results of dynamic reponse studies conducted in support of the efforts to certify the TPS for flight. The ceramic Thermal Protection System consists of ceramic tiles bonded to felt pads which are in turn bonded to the Orbiter substructure to protect the aluminum substructure from the heat of reentry.

Cooper, P. A.

Alternative High Performance Polymers for Ablative Thermal Protection Systems

Ablative thermal protection systems are commonly used as protection from the intense heat during re-entry of a space vehicle and have been used successfully on many missions including Stardust and Mars Science Laboratory both of which used PICA - a phenolic based ablator. Historically, phenolic resin has served as the ablative polymer for many TPS systems. However, it has limitations in both processing and properties such as char yield, glass transition temperature and char stability. Therefore alternative high performance polymers are being considered including cyanate ester resin, polyimide, and polybenzoxazine. Thermal and mechanical properties of these resin systems were characterized and compared with phenolic resin.

Ablator

Development and test of the Shuttle/Centaur cryogenic tankage thermal protection system

The Thermal Protection System (TPS) for the Shuttle/Centaur had to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort where the Shuttle and Centaur would return to earth. The TPS selected used a helium-purged polyimide foam beneath three radiation shields for the liquid hydrogen (LH2) tank and radiation shields only for the liquid oxygen (LO2) tank (three shields on the tank sidewall and four on the aft bulkhead). An evacuated common intermediate bulkhead separated the two tanks. The LH2 tank had one 1.9-cm thick layer of foam on the forward bulkhead and two layers on the larger area side-wall. Full scale tests of the flight vehicle in a simulated Shuttle cargo bay, that was purged with gaseous nitrogen, gave total prelaunch heating rates of 25.9 kW and 12.9 kW for LH2 and LO2 tanks, respectively. Calorimeter tests on a representative LH2 tank sidewall TPS sample indicated that the measured unit heating rate would rapidly decrease from the prelaunch rate of 300 W/sq m to a desired rate of less than 4 W/sq m once on-orbit.

Knoll, R. H.

Design, development, and test of Shuttle/Centaur G-prime cryogenic tankage thermal protection systems

The thermal protection systems (TPS) for the Shuttle/Centaur were designed to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort, where the Shuttle and Centaur would return to earth. The TPS selected used a helium-purged polyimide foam beneath three radiation shields for the liquid-hydrogen (LH2) tank and radiation shields only for the liquid-oxygen (LO2) tank. A double-walled vacuum bulkhead separated the two tanks. The LH2 tank had one 1.9 cm-thick layer of foam on the forward bulkhead and two layers on the larger-area sidewall. Full scale tests of the flight vehicle in a simulated Shuttle cargo bay gave total prelaunch heating rates of 29.5 and 12.9 kW for the LH2 and LO2 tanks, respectively. Calorimeter tests on a representative sample of the LH2 tank sidewall TPS indicated that the measured unit heating one would rapidly decrease from the prelaunch rate of about 300 W/sq m to a desired rate less than 4 W/sq m once on-orbit.

Macneil, Peter N.

Modernization of Insulative Reusable Thermal Protection Systems (IRTPS)

Insulative thermal protection systems, such as Flexible Reusable Surface Insulation blankets and High Temperature Reusable Surface Insulation tiles, were developed for the Shuttle Orbiter to enable reuse of the vehicle for low-earth orbit missions. Since reusability is essential to many new industry launch and space vehicles, Shuttle-derived thermal protection materials (TPMs) are being sought for their flight proven performance. Alumina Enhanced Thermal Barrier (AETB) is the state-of-the-art tile material that was developed in the 90’s. AETB along with associated coatings, reaction cured glass (RCG) and Toughened Unipiece Fibrous Insulation (TUFI), are currently made by NASA using heritage raw materials derived from lifetime purchases. Finding viable replacements for raw materials that have changed in nature or are obsolete is important for continuation of these TPMs. In some cases, the use of modern raw materials has been shown to yield tile with reduced performance, most notably in mechanical properties. ​ In this work, the production of AETB will be discussed to better understand the process-structure-property relationships and for allowing use of these modern alternatives. A small-scale tile casting system was developed for rapid and efficient exploration of the manufacturing variables such raw material selection and pre-processing, casting process parameters, and billet firing protocols. An optical transmission defect characterization technique was implemented to correlate process variables to structure. Comparisons between TUFI/RCG coated AETB derived from heritage and modern raw materials will be shown including AHF arc jet test results completed under a collaboration with Stratolaunch.

thermal protection materials

Heat flux instrumentation for Hyflite thermal protection system

Using Thermal Protection Tile core samples supplied by NASA, the surface characteristics of the FRCI, TUFI, and RCG coatings were evaluated. Based on these results, appropriate methods of surface preparation were determined and tested for the required sputtering processes. Sample sensors were fabricated on the RCG coating and adhesion was acceptable. Based on these encouraging results, complete Heat Flux Microsensors were fabricated on the RCG coating. The issue of lead attachment was addressed with the annnealing and welding methods developed at NASA Lewis. Parallel gap welding appears to be the best method of lead attachment with prior heat treatment of the sputtered pads. Sample Heat Flux Microsensors were submitted for testing in the NASA Ames arc jet facility. Details of the project are contained in two attached reports. One additional item of interest is contained in the attached AIAA paper, which gives details of the transient response of a Heat Flux Microsensors in a shock tube facility at Virginia Tech. The response of the heat flux sensor was measured to be faster than 10 micro-s.

Diller, T. E.

Current Technology for Thermal Protection Systems

Interest in thermal protection systems for high-speed vehicles is increasing because of the stringent requirements of such new projects as the Space Exploration Initiative, the National Aero-Space Plane, and the High-Speed Civil Transport, as well as the needs for improved capabilities in existing thermal protection systems in the Space Shuttle and in turbojet engines. This selection of 13 papers from NASA and industry summarizes the history and operational experience of thermal protection systems utilized in the national space program to date, and also covers recent development efforts in thermal insulation, refractory materials and coatings, actively cooled structures, and two-phase thermal control systems.

Scotti, Stephen J.

Thermal and aerothermal performance of a titanium multiwall thermal protection system

A metallic thermal protection system (TPS) concept the multiwall designed for temperature and pressure at Shuttle body point 3140 where the maximum surface temperature is approximately 811 K was tested to evaluate thermal performance and structural integrity. A two tile model of titanium multiwall and a model consisting of a low temperature reusable surface insulation (LRSI) tiles were exposed to 25 simulated thermal and pressure Shuttle entry missions. The two systems performed the same, and neither system deteriorated during the tests. It is indicated that redesign of the multiwall tiles reduces tile thickness and/or weight. A nine tile model of titanium multiwal was tested for radiant heating and aerothermodynamics. Minor design changes that improve structural integrity without having a significant impact on the thermal protection ability of the titanium multiwall TPS are identified. The capability of a titanium multiwall thermal protection system to protect an aluminum surface during a Shuttle type entry trajectory at locations on the vehicle where the maximum surface temperature is below 811 K is demonstrated.

Avery, D. E.

Thermal Protection Systems and Materials

Thermal protection systems protect space vehicles from aerodynamic heating during entry into planetary atmospheres. The Thermal Protection Materials Branch combines experiment, fabrication, characterization, evaluation, analysis and modeling to support NASA missions and collaborates externally to technology transfer thermal protection materials and tools to commercial or other agency partners.

Modeling

TPS Certification by Analysis: Model-Driven Characterization of Properties and Failure in Woven Thermal Protection Systems

Woven, ablative thermal protection system (TPS) materials provide a robust option for aggressive (re)entries and thus have been baselined for the upcoming Mars Sample Return (MSR) mission's Earth Entry System (EES). The reliability requirements for MSR-EES necessitate understanding of material property variability, which could be significant given the complex structure and anisotropic nature of properties in TPS weaves, as well as the response to potential impact with micrometeoroids or orbital debris during the EES re-entry. The TPS Certification by Analysis effort within the Entry Systems Modeling project seeks to provide computational models and analyses that support the certification against such material-based risks. For the present talk, focus will be given to the characterization of baseline woven TPS material properties and mechanical failure limits, which entails (1) use of computational techniques (e.g., machine learning) to interpret computed tomography images of the weave to generate representative structural models and (2) application of multiscale material modeling approaches to characterize thermomechanical and failure properties.

thermal protection systems