Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal damage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal Damage Potential of Electric Vehicles

The main objective is to assess the risk that electric vehicle (EV) battery fires pose regarding thermal damage to other vehicles involved in a crash and to compare EV and internal combustion engine vehicle (ICEV) fires. A literature review of experimental data and statistics are used to perform the assessment. The findings indicate: (1) the heat flux emitted from an EV and ICEV fire are similar due to cabin materials being the main contributor to heat flux, (2) for ICEVs involved in a crash with fuel tank leakage, the thermal damage is significantly more than from an EV fire for equivalent fire durations, (3) the thermal damage potential from ICEV pool fires is at least 5 times higher than EV fires, and (4) EV and ICEV crashes resulting in a fire is about 0.002% and 0.2%, respectively. Thus, EV battery fires have a lower risk than ICEV fires.

33 ADVANCED PROPULSION SYSTEMS↗

Investigation of thermal damage in explosive bridgewire detonators via discrete element method simulations

Exploding bridgewire (EBW) detonators are used to rapidly and reliably initiate energetic reactions by exploding a bridgewire via Joule heating. While the mechanisms of EBW detonators have been studied extensively in nominal conditions, comparatively few studies have addressed thermally damaged detonator operability. We present a mesoscale simulation study of thermal damage in a representative EBW detonator, using discrete element method (DEM) simulations that explicitly account for individual particles in the pressed explosive powder. We use a simplified model of melting, where solid spherical particles undergo uniform shrinking, and fluid dynamics are ignored. The subsequent settling of particles results in the formation of a gap between the solid powder and the bridgewire, which we study under different conditions. In particular, particle cohesion has a significant effect on gap formation and settling behavior, where sufficiently high cohesion leads to coalescence of particles into a free-standing pellet. This behavior is qualitatively compared to experimental visualization data, and simulations are shown to capture several key changes in pellet shape. We derive a minimum and maximum limit on gap formation during melting using simple geometric arguments. In the absence of cohesion, results agree with the maximum gap size. With increasing cohesion, the gap size decreases, eventually saturating at the minimum limit. In conclusion, we present results for different combinations of interparticle cohesion and detonator orientations with respect to gravity, demonstrating the complex behavior of these systems and the potential for DEM simulations to capture a range of scenarios.

cohesive powders↗

The Influence of Carbon Fiber Composite Specimen Design Parameters on Artificial Lightning Strike Current Dissipation and Material Thermal Damage

Previous artificial lightning strike direct effect research has examined a broad range of specimen design parameters. No works have studied how such specimen design parameters and electrical boundary conditions impact the dissipation of electric current flow through individual plies. This article assesses the influence of carbon fiber composite specimen design parameters (design parameters = specimen size, shape, and stacking sequence) and electrical boundary conditions on the dissipation of current and the spread of damage resulting from Joule heating. Thermal-electric finite element (FE) modelling is used and laboratory scale (<1 m long) and aircraft scale (>1 m long) models are generated in which laminated ply current dissipation is predicted, considering a fixed artificial lightning current waveform. The simulation results establish a positive correlation between the current exiting the specimen from a given ply and the amount of thermal damage in that ply. The results also establish that the distance to ground, from the strike location to the zero potential boundary conditions (ground), is the controlling factor which dictates the electric current dissipation in each ply. Significantly, this distance to ground is dependent on each of the specimen shape, dimensions, stacking sequence, and location of ground boundary conditions. Therefore, it is not possible to decouple current dissipation and damage from specimen design and boundary condition setup. However, it is possible to define a specimen size for a given specimen shape, stacking sequence, and waveform which limit the influence of specimen dimensions on the resulting current distribution and damage. For a rectangular specimen design which appears in literature multiple times, as 100 × 150 mm and with a stacking sequence of [45/0/-45/90] 4s , a specimen design of greater than 300 × 200 mm is required to limit the influence of specimen dimensions on current distribution and damage.

36 MATERIALS SCIENCE↗

Operability thresholds for thermally damaged EBW detonators

Operability thresholds that differentiate between functional RP-87 exploding bridge wire (EBW) detonators and nonfunctional RP-87 EBW detonators (duds) were determined by measuring the time delay between initiation and early wall movement (function time). The detonators were inserted into an externally heated hollow cylinder of aluminum and fired with current flow from a charged capacitor using an exploding bridge wire (EBW initiated). Functioning detonators responded like unheated pristine detonators when the function time was 4 μs or less. The operability thresholds of the detonators were characterized with a simple decomposition cookoff model calibrated using a modified version of the Sandia Instrumented Thermal Ignition (SITI) experiment. These thresholds are based on the calculated state of the PETN when the detonators fire. The operability threshold is proportional to the positive temperature difference (ΔT) between the maximum temperature within the PETN and the onset of decomposition (~406 K). Furthermore, the temperature difference alone was not sufficient to define the operability threshold. The operability threshold was also proportional to the time that the PETN had been at elevated temperatures. That is, failure was proportional to both temperature and reaction rate. The reacted gas fraction is used in the current work for the reaction correlation. Melting of PETN also had a significant effect on the operability threshold. Detonator failure occurred when the maximum temperature exceeded the nominal melting point of PETN (414 K) for 45±5 s or more.

42 ENGINEERING↗

A liquid stratification model to predict failure in thermally damaged EBW detonators

In previous work, commercially available downward facing exploding bridgewire detonators (EBWs) were exposed to elevated temperatures. These detonators were then initiated using a firing set which discharged a high amplitude short duration electrical pulse into a thin gold bridgewire. Responses of the detonators were measured using photonic doppler velocimetry (PDV) and high-speed photography. A time delay of 4 μs between EBW initiation and first movement of an output flyer separated operable detonators from inoperable detonators or duds. Here, we propose a simple method to determine detonator operability from the calculated state of the detonator at the time the firing set is initiated. The failure criterion is based on the gap distance between the exploding bridgewire (EBW) and the adjacent initiating explosive within the detonator which is low-density pentaerythritol tetranitrate (PETN) that melts between 413-415 K (140-142 ºC). The gap forms as PETN melts and flows to the bottom of the input pellet. Melting of PETN is modeled thermodynamically as an energy sink using a normal distribution spread over a temperature range between the onset temperature of 413 K and the ending temperature of 415 K. The extent of the melt is determined from the average temperature of the PETN. The PETN liquid is assumed to occupy the interstitial gas volume in the lower part of the input pellet. The vacated volume from the relocated liquid forms the gap between the EBW and the PETN. The remaining sandwiched layer consists of solid PETN particles and gas filling interstitial volume. We predict that a threshold gap between 17-27 μm separates properly functioning detonators from duds.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Determination of Thermal Damage Threshold in THz Photomixers Using Raman Spectroscopy

The increase of device lifetime and reliability of THz photomixers will play an essential role in their possible future application. Therefore, their optimal work conditions/operation range, i.e., the maximal incident optical power should be experimentally estimated. We fabricated and tested THz photomixer devices based on nitrogen-implanted GaAs integrated with a Bragg reflector. Raman spectroscopy was applied to investigate the material properties and to disclose any reversible or irreversible material changes. The results indicate that degradation effects in the photomixer structures/material could be avoided if the total optical power density does not exceed levels of about 0.7 mW/µm 2 for 100 min of operation. Furthermore, the investigations performed during 1000 min of optical exposure on the photomixer devices’ central region comprising interdigitated metal-semiconductor-metal (MSM) structures suggest a reversible “curing” mechanism if the power density level of ~0.58 mW/µm 2 is not exceeded. Long-term operation (up to 1000 h) reveals that the photomixer structures can withstand an average optical power density of up to ~0.4 mW/µm 2 without degradation when biased at 10 V. Besides the decrease of the position of the A1g (LO) Raman mode from ~291 cm -1 down to ~288 cm -1 with increasing optical power density and operation time, broad Raman modes evolve at about 210 cm -1 , which can be attributed to degradation effects in the active photomixer/MSM area. In addition, the performed carrier lifetime and photomixer experiments demonstrated that these structures generated continuous wave sub-THz radiation efficiently as long as their optimal work conditions/operation range were within the limits established by our Raman studies.

36 MATERIALS SCIENCE↗

Modeling nuclear waste disposal in crystalline rocks at the Forsmark and Olkiluoto repository sites – Evaluation of potential thermal–mechanical damage to repository excavations

We conduct coupled thermo-hydro-mechanical modeling of a KBS-3V repository design in crystalline rocks, using data and conditions from the Forsmark in Olkiluoto repository sites in Sweden and Finland. The study focuses on repository performance related to the impact of thermal and hydraulic evolution on the potential for thermal–mechanical damage to underground repository excavations. For the designs and conditions considered at the Forsmark and Olkiluoto repository sites, the simulations show a peak temperature well under the adopted performance target of a 100°C maximum temperature, whereas there is still a high potential for thermal–mechanical damage to the KBS-3V waste deposition holes. The thermal–mechanical damage is much more likely if rock permeability is so low that it delays saturation and swelling of bentonite-clay-based backfill beyond the time for the thermal–mechanical peak, which occurs 50 to 100 years after nuclear waste deposition. We also found that sidewalls of the KBS-3V emplacement tunnels are vulnerable to tensile fracturing due to the combined effect of thermal stressing and backfill swelling. The study highlights a strong interaction between bentonite-based backfill and host rock through capillary suction along with induced rock desaturation. A careful design and selection of the bentonite-clay-based backfill materials for KBS-3V tunnels and deposition holes can facilitate a timely saturation and backfill swelling that in turn can minimize thermal–mechanical damage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CISME report on experiments with HMX powder, PBX 9501 prills, and heated PBX 9501

The ability to predict post-ignition explosive response is relevant to explosives safety, particularly weapons assembly/disassembly operations that must operate under a sufficiently conservative safety basis to meet risk mitigation criteria for inadvertent nuclear detonation (IND). In particular, hazard determinations hinge on whether the PBX 9501 main charge can ultimately attain detonation from an initial, non-shock, ignition stimulus. The CISME experiment uses a spherical explosive charge, which is thermally ignited in the center using a fiber-delivered infrared laser pulse. This ignition mechanism - i.e. a localized thermal hotspot - is representative of the ignition-causing insults typical in accident scenarios, including low-velocity impact, drop, skid, and punch events. In fiscal year 2018 CISME experiments were conducted with pristine PBX 9501 spheres, confined and unconfined. Sub-detonative, low-violence reactions were observed. Here we report experiments conducted since 2018. The explosive charge was varied: experiments were conducted with room temperature pour-density HMX powder and prills of PBX 9501, and heated, thermally damaged PBX 9501. Experiments were conducted in a confined configuration, with two 4 mm-thick stainless-steel hemispherical shells bolted around the sphere. Detonation, via DDT (deflagration-to-detonation transition) was observed in the 3-inch diameter powdered HMX and the 6-inch diameter heated and thermally-damaged PBX 9501 tests. No transition to DDT was observed in smaller diameters for those configurations, and no DDT was observed for pour-density prills of PBX 9501 of any diameter. The original test series demonstrated that the response of pristine, undamaged PBX 9501 to a central ignition is relatively benign. This new test series shows that increased porosity, lack of polymer binders and thermal damage can greatly increase the violence of the post-ignition response, up to and including detonation. These results bridge the explosive response of PBX 9501 from sub-detonative through detonation as a function of diameter and provide valuable test cases for modeling efforts that strive to capture the DDT threshold. By exploring explosive response in a more representative 3D geometry, we can also benchmark these new results to more plentiful DDT datasets generated from testing in 1D tube confinement (the historical test configuration)–the configuration upon which almost all DDT models were developed.

42 ENGINEERING↗

Thermal stress in degraded forests in the Brazilian Amazon Arc of Deforestation

Understanding thermal stress in tropical forests has taken on new urgency in light of accelerating climate change and expansion of deforestation and forest degradation. Degraded tropical forests in particular may be approaching critical temperature thresholds even more rapidly than intact forests, with implications for tree survival and ecosystem recovery. We investigate thermal stress in degraded tropical forests within the Brazilian Amazon Arc of Deforestation. Using land surface temperature data from the ECOsystem Spaceborne Thermal Radiometer Experiment on the international Space Station (ECOSTRESS), we compared canopy temperatures of intact, selectively logged, and burned forests in Feliz Natal, Mato Grosso, Brazil. Upper canopy temperatures in previously burned forests were 4.1% higher (mean = 36.5 °C) and 50.9% more variable compared to intact and logged forests, which showed remarkably similar temperature distributions (means of 34.9 °C and 35.1 °C, respectively). Modeled leaf temperature distributions based on canopy temperature measurements from one of the warmest days in a 2 year dry season record indicated that 87% of leaves in the warmest burned forest patches exceeded the temperature threshold where respiration surpasses photosynthesis, compared to approximately 72%–74% in intact and logged forests, respectively, in the same time period. After controlling for environmental factors, burned forests were predicted to be 2.6 °C warmer on average [1.39 °C–3.96 °C, 95% credible interval] than intact forests across a 5–40 m canopy height range. Burned forests showed modest thermal recovery over time, with temperatures decreasing by approximately 1.2 °C over a 30 year recovery period. In contrast, logged forests showed minimal thermal differences from intact forests (−0.353 on average, [−1.125–0.274, 95% credible interval]) and negligible change (0.15 °C) over the same timeframe. While the absolute probabilities of exceeding damaging thermal thresholds remain low across all forest types under current climate conditions, the probability of leaves exceeding temperatures that cause permanent leaf damage was ten times higher in burned forests, with implications for the future of burned forest regeneration in water-limited regions of the Amazon basin. In particular, the combination of higher mean temperatures, greater temperature variability, and more frequent exposure to damaging thermal thresholds implies that burned tropical forests will experience substantially higher mortality rates and slower biomass recovery compared to intact and selectively logged forests, especially in water-limited regions where trees cannot rely on evaporative cooling to moderate canopy temperatures.

Brazilian Amazon Arc of Deforestation↗

Integrated Neutronics Modeling for Inertial Fusion Energy Systems: Development and Application to LD-FIRST

Lawrence Livermore National Laboratory (LLNL) is proposing a new Laser Driven Fusion Integration Research and Science Test Facility (LD-FIRST) with the goal of providing an experimental testbed for future Inertial Fusion Energy (IFE) systems. However, IFE systems require detailed and accurate multiphysics modeling to quantify material damage, thermal loading, and tritium breeding within complex chamber environments. This article presents the first step in an integrated multiphysics framework that couples meshed CAD-based geometry within Monte Carlo neutronic simulations to enable high-fidelity analysis of IFE chamber concepts, with future coupling to external codes. The neutronics workflow utilizes OpenMC and its third-party capability to use CAD-based geometries through DAGMC and tally on unstructured meshes with Libmesh to evaluate neutron transport behavior, geometric fidelity, and material performance under reactor-relevant conditions. The use of tailored tallies on unstructured meshes in this framework allows direct transfer without interpolating to CFD simulation tools. Two IFE chambers were evaluated, both conceived by LLNL: HYLIFE-II and Laser IFE (LIFE). This work produced high-fidelity conformal surface and volumetric meshes of the HYLIFE-II and LIFE chambers with mapped spatial insight into material damage, thermal loading, and tritium breeding. The HYLIFE-II model was built utilizing available resources and used as a test case to verify that the neutronics framework can handle complex geometries. The LIFE chamber CAD was provided by LLNL and was the main focus of this work. This work analyzes multiple ternary alloy breeding materials for the LIFE chamber, across different 6 Li enrichments to produce data relevant to the LD-FIRST project. This work also investigates the level of model fidelity for the LIFE chamber, and results show that inclusion of detailed first wall and coolant structures increased the predicted tritium breeding ratio (TBR) by ~30%, highlighting the sensitivity of tritium breeding and the need for a high-fidelity simulation framework for IFE chambers. These developments provide a scalable toolset for the design and optimization of next-generation IFE chambers, forming a solid foundation for future coupled multiphysics analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MORPHOLOGICAL AND RADIATION DAMAGE INFORMED THERMAL PROPERTY PREDICTION IN SCALED GEOMETRIC DOMAINS

This proposed work has the potential to rewrite the way the nuclear industry investigates new fuel and nuclear material designs. The current rubric of nuclear material design has myriad steps in the process, and while certain physics are modeled accurately, each step must be connected in order to obtain an entire description of the process. At present, neutronic, thermal, microstructural, fission product chemistry and migration, and radiation defect analysis (hereafter referred to together as “combined analysis”) are performed, albeit separately. There is no existing method which combines these physics in an attempt to understand the natural interactions between these phenomena. Consequently, the timeline for design, fabrication, experiment, validation, and licensing can take years. A disruptive approach is required to accelerate the development of new technology. This proposed undertaking creates a validated computational framework, generating a new microscopic-to-macroscopic methodology yielding thermal property predictions for nuclear fuels and materials at an engineering spatial scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Supersonic hot jet ablative testing and analysis of boron nitride nanotube hybrid composites

Boron nitride nanotubes (BNNTs) are high-strength, high-modulus nanotubes with high thermal and oxidative stabilities. Two hybrid composites were prepared with satin weave carbon fiber (CF) and resole-type phenolic resin: one with surface layers of BNNTs and one with alternating interlayers of BNNTs. The samples were subjected to hot jet tests that simulate realistic high-pressure-temperature conditions to understand the behavior of BNNTs under high-pressure erosion. Adding BNNTs to CF/phenolic laminates enhanced the ablation resistance by reinforcing the char material and mitigated localized thermal damage. Hybrid laminates exhibited up to 14% lower weight loss, 55% increase in flexural modulus, higher thermal diffusivity, and improved char yield and microstructure compared to CF/phenolic samples. The surface layer hybrid had many surviving nanotubes reinforcing the char and crystalline oxide structures that could mitigate further oxygen diffusion. Further, various characterization methods were used to deduce possible mechanisms and their products, indicating that BNNTs could serve as growth templates for direct crystalline boron oxide formation. Overall, hybrid BNNT/CF/phenolic laminates displayed better ablation resistance and favorable microstructure evolution under high-pressure conditions.

42 ENGINEERING↗

Clinkerless ultra-high strength concrete based on alkali-activated slag at high temperatures

This work investigates the degradation mechanisms of clinkerless alkali-activated slag based ultra-high strength concrete (AAS-UHSC) upon exposure to high temperatures up to 800 °C. The heat-induced mechanical, mineralogical, molecular, microstructural, and pore structure alterations of AAS-UHSC prepared with various activator types, water-to-powder ratios, and fiber incorporation are studied. The results demonstrate the beneficial roles of potassium incorporation on improving the thermal stability and integrity of AAS-UHSC, via suppressing deleterious crystallization and transformation of aluminosilicate phases at high temperature. In contrast to Portland cement clinker-based UHSC, no sign of explosive spalling is observed in AAS-UHSC, likely due to the presence of microcracks that enhance the pore network connectivity. The mechanical degradation of AAS-UHSC at high temperature below 600 °C is resulted from dehydration and decomposition of phases and consecutive thermal cracking, together with enlarged porosity and coarsened pore structure. As the temperature rising to 800 °C, crystallization and transformation of phases, as well as formation of porous microstructure, considerably aggravate the mechanical degradation of AAS-UHSC. In contrast to the thermal damage mitigation by polymeric fibers in conventional UHSC, the fiber incorporation has little positive impact on the thermal resistance of AAS-UHSC.

36 MATERIALS SCIENCE↗

Heavily Confined PBX 9501 Experiment Report FY2020

Most accidental insults to explosives are invariably thermal in nature—either direct thermal via application of heat or indirect thermal when mechanical energy is converted to heat. The key question is whether the initial thermal insult transitions into a violent explosive response. If the ultimate violence attained is moderate, nearby personnel may be harmed or killed, but Inadvertent Nuclear Detonation (IND) will not occur. However, if the explosive ultimately transitions from deflagration to detonation (DDT) then IND becomes a concern. PBX 9501 is not an insensitive high explosive (IHE). It has been conclusively demonstrated that mechanically and thermally damaged PBX 9501 can readily DDT in heavy confinement. However, it is currently unknown whether pristine explosive—i.e. thermally and mechanically undamaged— is capable of DDT. Three experiments were conducted in order to determine whether very heavily confined pristine PBX 9501 is capable of DDT. All experiments used identical 6-inch diameter spherical charges of PBX 9501 confined in a 350 lb. hardened steel vessel with >2.5-inch thick walls. The first, primary experiment tested pristine PBX 9501 and was thermally ignited at the center of using a laser over optical fiber. Two additional baseline experiments were performed for comparison: the second test was initiated at the center using a detonator; the third test was bulk heated until self-ignition (cookoff). Velocimetry data in combination with hydrocode simulations suggest that a classical detonation wave did not develop in the pristine, thermally ignited PBX 9501. Reaction violence was approximately equivalent—in terms of ultimate energy output—as a full detonation, but the acceleration of metal fragments occurred more slowly than in a detonation-driven scenario.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Impact of molten salt inflow on the temperature distribution in thermal energy storage tanks at startup for central receiver concentrating solar power plants

Concentrating Solar Power (CSP) systems with molten salt thermal energy storage (TES) tanks are one of the most promising, renewable-based energy conversion technologies for larger-scale power generation. The TES tank is one of the most critical components in CSP plants due to its high-temperature operation (up to 565 °C), daily thermal cycling, and intermittent solar radiation conditions. The plant startup is one of the most challenging operation conditions that could lead to damaging thermal gradients due to low salt inventory levels. In this study an analytical model for the sparger ring was developed and integrated with a detailed computational fluid dynamics model of a commercial-scaled molten salt tank. The integrated model allows an accurate representation of the tank operation to evaluate the effect of molten salt inflow on the mixing process. The tank filling process during plant startup was analyzed considering sparger rings with variations in design features, including inlet orifice configurations, number of orifices, direction of the inlets, and orifice diameter. The results demonstrated that higher temperature gradients are obtained in the tank floor during the plant startup. A sparger ring configuration with a predetermined orifice inlet inclination (30°, 45° and 60°) leads to significant temperature differences in the floor, between 57 °C and 62 °C, but better homogeneity in the temperature of the salt inventory. Lower salt inflow velocities result in a more homogeneous floor temperature, with maximum temperature differences under 38 °C. The sparger ring configuration with 52 orifices of 1-in. diameter and vertical flow showed better homogeneity in the temperature differences as a function of the salt level and lower temperature gradients in the tank floor. Because large temperature gradients in the tank's floor have been identified as one of the main factors contributing to tank failures, assessing various sparger ring design features is fundamental to determining proper inflow conditions that lead to low-temperature gradients and reducing failure susceptibility.

14 SOLAR ENERGY↗

Pathways towards managing cost and degradation risk of fast charging cells with electrical and thermal controls

The charging rate of Li-ion batteries is limited by the risks of lithium plating and thermal damage, both of which negatively affect lifetime of the batteries. This work analyzes how to minimize charge time and manage the risk of degradation using both electrical and thermal controls. To accomplish this, an electrochemical-thermal model is developed to introduce a constant-risk fast charging protocol which maximizes the charging current while maintaining the cell within pre-defined design limits selected to minimize the risk of degradation. Results indicate 80%-charging of a typical NMC/graphite cell can be achieved within 10 minutes with a cell cost under $100 kW –1 h –1 (corresponding to an 80 μm thick anode) when charged at moderate allowable risks of degradation. Here, we also demonstrate how stretching the allowable risk (i.e., higher temperatures, larger C-rates, and lower anode potential limits) allows affordable design of fast charging cells.

25 ENERGY STORAGE↗