Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

DESIGN OF LABORATORY EXPERIMENTS TO STUDY PHOTOIONIZATION FRONTS DRIVEN BY THERMAL SOURCES

This paper analyzes the requirements of a photoionization-front experiment that could be driven in the laboratory, using thermal sources to produce the necessary flux of ionizing photons. It reports several associated conclusions. Such experiments will need to employ the largest available facilities, capable of delivering many kJ to MJ of energy to an X-ray source. They will use this source to irradiate a volume of neutral gas, likely of N, on a scale of a few mm to a few cm, increasing with source energy. For a gas pressure of several to ten atmospheres at room temperature, and a source temperature near 100 eV, one will be able to drive a photoionization front through a system of tens to hundreds of photon mean free paths. The front should make the familiar transition from the so-called R-Type to D-Type as the radiation flux diminishes with distance. The N is likely to reach the He-like state. Preheating from the energetic photons appears unlikely to become large enough to alter the essential dynamics of the front beyond some layer near the surface. For well-chosen experimental conditions, competing energy transport mechanisms are small.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrical power generation from moderate-temperature radiative thermal sources

Moderate-temperature thermal sources (100° to 400°C) which radiate waste heat are often the by-product of mechanical work, chemical or nuclear reactions, or information processing. We demonstrate conversion of thermal radiation into electrical power using a bipolar grating-coupled complementary metal-oxide-silicon (CMOS) tunnel diode. A two-step photon-assisted tunneling charge pumping mechanism results in separation of charge carriers in pn-junction wells leading to a large open-circuit voltage developed across a load. Electrical power generation from a broadband blackbody thermal source has been experimentally demonstrated with converted power densities of 27 to 61 microwatts per square centimeter for thermal sources between 250° and 400°C. Scalable, efficient conversion of radiated waste heat into electrical power can be used to reduce energy consumption or to power electronics and sensors.

30 DIRECT ENERGY CONVERSION↗

Power Generation from a Radiative Thermal Source Using a Large-Area Infrared Rectenna

Electrical power generation from a moderate-temperature thermal source by means of direct conversion of infrared radiation is important and highly desirable for energy harvesting from waste heat and micropower applications. Here, we demonstrate direct rectified power generation from an unbiased large-area nanoantenna-coupled tunnel diode rectifier called a rectenna. Using a vacuum radiometric measurement technique with irradiation from a temperature-stabilized thermal source, a generated power density of 8 nW / cm 2 is observed at a source temperature of 450°C for the unbiased rectenna across an optimized load resistance. The optimized load resistance for the peak power generation for each temperature coincides with the tunnel diode resistance at zero bias and corresponds to the impedance matching condition for a rectifying antenna. Current-voltage measurements of a thermally illuminated large-area rectenna show current zero crossing shifts into the second quadrant indicating rectification. Photon-assisted tunneling in the unbiased rectenna is modeled as the mechanism for the large short-circuit photocurrents observed where the photon energy serves as an effective bias across the tunnel junction. Furthermore, the measured current and voltage across the load resistor as a function of the thermal source temperature represents direct current electrical power generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nuclear thermal source transfer unit, post-blast soil sample drying system

Los Alamos National Laboratory states that its mission is “To solve national security challenges through scientific excellence.” The Science Undergraduate Laboratory Internship (SULI) programs exists to engage undergraduate students in STEM work by providing opportunity to work at DOE facilities. As an undergraduate mechanical engineering intern under the SULI program at Los Alamos during the fall semester of 2016, I had the opportunity to contribute to the mission of the Laboratory while developing skills in a STEM discipline. I worked with Technology Applications, an engineering group that supports non-proliferation, counter terrorism, and emergency response missions. This group specializes in tool design, weapons engineering, rapid prototyping, and mission training. I assisted with two major projects during my appointment Los Alamos. The first was a thermal source transportation unit, intended to safely contain a nuclear thermal source during transit. The second was a soil drying unit for use in nuclear postblast field sample collection. These projects have given me invaluable experience working alongside a team of professional engineers. Skills developed include modeling, simulation, group design, product and system design, and product testing.

42 ENGINEERING↗

Passive continuous variable quantum key distribution scheme using a thermal source

A passive continuous variable quantum key distribution scheme, where Alice splits the output of a thermal source into two beams, measures one locally and transmits the other mode to Bob after applying attenuation. A secure key can be established based on measurements of the two beams without the use of a random number generator or an optical modulator.

Qi, Bing↗

Quantum key distribution using a thermal source

A passive continuous-variable quantum key distribution scheme, where Alice splits the output of a thermal source into two spatial modes, measures one locally and transmits the other mode to Bob after applying attenuation. A secure key can be established based on measurements of the two modes without the use of a random number generator or an optical modulator.

97 MATHEMATICS AND COMPUTING↗

Planck intermediate results: LIV. The Planck multi-frequency catalogue of non-thermal sources$^\star$

This paper presents the Planck Multi-frequency Catalogue of Non-thermal (i.e. synchrotron-dominated) Sources (PCNT) observed between 30 and 857 GHz by the ESA Planck mission. This catalogue was constructed by selecting objects detected in the full mission all-sky temperature maps at 30 and 143 GHz, with a signal-to-noise ratio (S/N)> 3 in at least one of the two channels after filtering with a particular Mexican hat wavelet. As a result, 29 400 source candidates were selected. Then, a multi-frequency analysis was performed using the Matrix Filters methodology at the position of these objects, and flux densities and errors were calculated for all of them in the nine Planck channels. This catalogue was built using a different methodology than the one adopted for the Planck Catalogue of Compact Sources (PCCS) and the Second Planck Catalogue of Compact Sources (PCCS2), although the initial detection was done with the same pipeline that was used to produce them. The present catalogue is the first unbiased, full-sky catalogue of synchrotron-dominated sources published at millimetre and submillimetre wavelengths and constitutes a powerful database for statistical studies of non-thermal extragalactic sources, whose emission is dominated by the central active galactic nucleus. Together with the full multi-frequency catalogue, we also define the Bright Planck Multi-frequency Catalogue of Non-thermal Sources (PCNTb), where only those objects with a S/N > 4 at both 30 and 143 GHz were selected. In this catalogue 1146 compact sources are detected outside the adopted Planck GAL070 mask; thus, these sources constitute a highly reliable sample of extragalactic radio sources. We also flag the high-significance subsample (PCNThs), a subset of 151 sources that are detected with S/N > 4 in all nine Planck channels, 75 of which are found outside the Planck mask adopted here. The remaining 76 sources inside the Galactic mask are very likely Galactic objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Code Development Supporting a Non-Thermal Source of High Fluence Warm X-Ray

A six-month research effort has advanced the hybrid kinetic-fluid modeling capability required for developing non-thermal warm x-ray sources on Z. The three particle treatments of quasi-neutral, multi-fluid, and kinetic are demonstrated in 1D simulations of an Ar gas puff. The simulations determine required resolutions for the advanced implicit solution techniques and debug hybrid particle treatments with equation-of-state and radiation transport. The kinetic treatment is used in preliminary analysis of the non-Maxwellian nature of a gas target. It is also demonstrates the sensitivity of the cyclotron and collision frequencies in determining the transition from thermal to non-thermal particle populations. Finally, a 2D Ar gas puff simulation of a Z shot demonstrates the readiness to proceed with realistic target configurations. The results put us on a very firm footing to proceed to a full LDRD which includes continued development transition criteria and x-ray yield calculation.

36 MATERIALS SCIENCE↗

Using facility-level emissions data to estimate the technical potential of alternative thermal sources to meet industrial heat demand

Industry is frequently highlighted as the world's largest energy-using end-use sector. More specifically, the demand for heat drives much of the demand for energy and fossil fuels in the industrial sector. We conduct a top-down analysis to characterize historical energy and fossil fuel use in 14 top-GHG-emitting industries in the United States, their heat demand requirements, and the potential to substitute heat from geothermal, solar thermal (including concentrating technologies), and small modular nuclear reactors to meet these needs while reducing fossil-fuel use and greenhouse gas (GHG) emissions. We base this analysis on publicly-available facility-level GHG emissions and fuel-combustion data, in addition to assumed requirements for process temperature, to demonstrate the potential value to industry energy analysts of the U.S. Environmental Protection Agency's Greenhouse Gas Reporting Program data. We estimate on a county level that the adoption of these alternative heat sources could have reduced 2015 fossil-fuel use by approximately 31% and combustion GHG emissions by approximately 24%. The most extensive substitution opportunities are in the ethyl alcohol manufacturing and wet corn-milling industries; petroleum refining represents the largest absolute emissions mitigation potential. This initial top-down analysis of substitution potential does not consider more detailed technical factors, including resource availability that will influence the actual deployment of alternative energy technologies. The analysis also does not consider the economic or market factors, including the expected cost to build and operate these generators. We do assume process byproducts that are extensively used for combustion fuels would not be good candidates for substitution for alternative energy generators. Based on these caveats, our analysis could be considered a top-range estimate for this mix of heat generators and industry heat demands. Any subsequent analysis of these alternate energy sources should increase the level of technical, economic, and policy detail.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

INGENIOUS Thermal Conductivity Measurement Source Categorization

Thermal conductivity (TC) data taken for different wells at a specified drill depth. This is an abridged version of the complete SMU heat flow database, downloaded from the SMU node of the NGDS at the beginning of INGENIOUS (approximately April 2021), and filtered to the INGENIOUS study area. This National Geothermal Data System (NGDS) project aggregates geothermal data collected and curated by the SMU Geothermal Laboratory and its partner organizations. All columns in this database are the same as the SMU database, except for 2 additions associated with this project. Repeated columns are for data correlation purposes. Column descriptions and data types are the same as previous iterations of the SMU database. The new values that are the addition are two new columns developed as part of the INGENIOUS project: INGENIOUS TC Value | INGENIOUS notes INGENIOUS notes are individual notes that were written for specific data points during the analysis process. There are not always notes associated with each input value. INGENIOUS TC Value includes 4 values: 1. Assumed Measured These are values that are assumed to be measured thermal conductivity values, either within a specific well or within the same study region. Many of these have either a published reference, a reported standard deviation, or a unique thermal conductivity value. 2. Data release - assumed measured These are values in the SMU database that are from proprietary data that were added to the SMU database and are labeled as data release for their reference. These values were searched for in person at the SMU Geothermal Laboratory as well as virtual examination of data available on the NGDS. For many of these, there are reported thermal conductivity values associated with the heat flow data in the database, but no specific table or reference to measurements in the original data release files. 3. Known measured These are values that have a reported measurement, either as an original file in the SMU data files on the NGDS or a reported table in a publication. In the rare circumstances, Maria Richards or David Blackwell confirmed measurement. Confirmation of measurement would be written in the INGENIOUS notes column. 4. Unmeasured Unmeasured values are those that are known to be unmeasured, either estimated from another report or no information given. In the SMU database, there are wells that have a heat flow but no thermal conductivity. These are categorized as unmeasured. There are also heat flow values that are stated to have estimated or generalized average thermal conductivity values for the region and rock type. Because these are known to be unmeasured, they are categorized as such. 5. Blank Blank values are either A quality or X quality. These quality values are stated in the INGENIOUS notes. These values were not going to change associated with the heat flow analysis, so these were not examined.

15 GEOTHERMAL ENERGY↗

Demonstration of non-destructive and isotope-sensitive material analysis using a short-pulsed laser-driven epi-thermal neutron source

Neutrons are a valuable tool for non-destructive material investigation as their interaction cross sections with matter are isotope sensitive and can be used complementary to x-rays. So far, most neutron applications have been limited to large-scale facilities such as nuclear research reactors, spallation sources, and accelerator-driven neutron sources. Here we show the design and optimization of a laser-driven neutron source in the epi-thermal and thermal energy range, which is used for non-invasive material analysis. Neutron resonance spectroscopy, neutron radiography, and neutron resonance imaging with moderated neutrons are demonstrated for investigating samples in terms of isotope composition and thickness. The experimental results encourage applications in non-destructive and isotope-sensitive material analysis and pave the way for compact laser-driven neutron sources with high application potential.

36 MATERIALS SCIENCE↗

Radiological Characterization of Selected Thermal Centres Based on Indoor Radon Dosimetry - 17507

In countries with long historical tradition in thermal water therapy and with several mineral-medicinal thermal sources, workplaces within thermal centers may be a source of radon exposure which may be intensified if these are located in regions of high level of natural radiation. According to the EU Directive 96/29/Euratom (repealed by the Directive 2013/59/EURATOM) each Member State shall identify, by means of survey or any other adequate mean, the work activities where a significant increase in the exposure from natural radiation sources may occur, including thermal centers where the exposure to thoron/radon daughters or gamma radiation may occur. The purpose of this work was to perform a radiological characterization of selected thermal centers based on indoor dosimetry. The effective doses received by workers due to radon inhalation were estimated and gamma dose rates were measured through continuous periods. The radon risk for indoor exposure was assessed on a probabilistic basis both on thermal centers and workers' dwellings. Radon levels within the thermal centers ranged from 73 to 4335 Bq/m{sup 3} and the values within the workers dwellings are of the same order of magnitude, 68-4051 Bq/m{sup 3}. Approximately 66 % of indoor radon concentration values are above the maximum EU reference (300 Bq/m{sup 3}) and 94 % of the effective dose is higher than 1 mSv/year. In some situations, radon levels at residential environments are much higher than at workplaces and effective doses are higher than 6 mSv/year, both at residential and work environments. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Passive state preparation in the Gaussian-modulated coherent-states quantum key distribution

In the Gaussian-modulated coherent-states (GMCS) quantum key distribution (QKD) protocol, Alice prepares quantum states actively: For each transmission, Alice generates a pair of Gaussian-distributed random numbers, encodes them on a weak coherent pulse using optical amplitude and phase modulators, and then transmits the Gaussian-modulated weak coherent pulse to Bob. Here we propose a passive state preparation scheme using a thermal source. In our scheme, Alice splits the output of a thermal source into two spatial modes using a beam splitter. She measures one mode locally using conjugate optical homodyne detectors, and transmits the other mode to Bob after applying appropriate optical attenuation. Under normal conditions, Alice's measurement results are correlated to Bob's, and they can work out a secure key, as in the active state preparation scheme. Given the initial thermal state generated by the source is strong enough, this scheme can tolerate high detector noise at Alice's side. Furthermore, the output of the source does not need to be single mode, since an optical homodyne detector can selectively measure a single mode determined by the local oscillator. Preliminary experimental results suggest that the proposed scheme could be implemented using an off-the-shelf amplified spontaneous emission source.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗