Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature Stratification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Temperature stratification from thermal diodes in solar hot water storage tank

In this brief note, we have experimentally measured the temperature stratification in a solar hot water storage tank resulting from a simulated solar heating load. Various modifications using a double chimney device that acts as a thermal diode were examined with the intent of maximizing temperature stratification. The greatest stratification was seen with a unique thermal diode arrangement named the express-elevator design, so-called for the direct hot water path from the bottom third of the tank to the top third. (author)

14 SOLAR ENERGY↗

Considerations for the temperature stratification in a pre-burn constant-volume combustion chamber

In recent years, the Engine Combustion Network (ECN) has developed as a worldwide reference for understanding and describing engine combustion processes, successfully bringing together experimental and numerical efforts. Since experiments and numerical simulations both target the same boundary conditions, an accurate characterization of the stratified environment that is inevitably present in experimental facilities is required. The difference between the core-, and pressure-derived bulk-temperature of pre-burn combustion vessels has been addressed in various previous publications. Additionally, thermocouple measurements have provided initial data on the boundary layer close to the injector nozzle, showing a transition to reduced ambient temperatures. The conditions at the start of fuel injection influence physicochemical properties of a fuel spray, including near nozzle mixing, heat release computations, and combustion parameters. To address the temperature stratification in more detail, thermocouple measurements at larger distances from the spray axis have been conducted. Both the temperature field prior to the pre-combustion event that preconditions the high-temperature, high-pressure ambient, as well as the stratification at the moment of fuel injection were studied. To reveal the cold boundary layer near the injector with a better spatial resolution, Rayleigh scattering experiments and thermocouple measurements at various distances close to the nozzle have been carried out. The impact of the boundary layers and temperature stratification are illustrated and quantified using numerical simulations at Spray A conditions. Next to a reference simulation with a uniform temperature field, six different stratified temperature distributions have been generated. These distributions were based on the mean experimental temperature superimposed by a randomized variance, again derived from the experiments. The results showed that an asymmetric flame structure arises in the computed results when the temperature stratification input is used. In these predictions, first-stage ignition is advanced by 24 $\mu$s , while second-stage ignition is delayed by 11 $\mu$s. At the same time a lift-off length difference between the top and the bottom of up to 1.1 mm is observed. Furthermore, the lift-off length is less stable over time. Given the shown dependency, the temperature data is made available along with the vessel geometry data as a recommended basis for future numerical simulations.

42 ENGINEERING↗

Impact on Water Heater Performance of Heating Methods that Promote Tank Temperature Stratification

During heating of a water heater tank, the vertical temperature stratification of the water can be increased or decreased, depending on the method of heating. Methods that increase stratification during heating include (1) removing cold water from the tank bottom, heating it, and re-introducing it to the tank top at relatively low flow rate, (2) using a heat exchanger wrapped around the tank, through which heating fluid (with finite specific heat) flows from top to bottom, and (3) using an immersed heat element that is relatively high in the tank. Using such methods allows for improved heat pump water heater (HPWH) cycle efficiencies when the heat pump can take advantage of the lower temperatures that exist lower in the tank, and accommodate the resulting glide. Transcritical cycles are especially well-suited to capitalize on this opportunity, and other HPWH configurations (that have been proposed elsewhere) may benefit as well. This work provides several stratification categories of heat pump water heater tank configurations relevant to their stratification potential. To illustrate key differences among categories, it also compiles available experimental data for (a) single pass pumped flow, (b) multi-pass pumped flow, and (c) top-down wrapped tank with transcritical refrigerant.

Gluesenkamp, Kyle R↗

Sensible-Enthalpy-Based Conditional Moment Closure Model for Homogeneous Charge Compression Ignition with Temperature Inhomogeneity

Abstract This paper presents a sensible-enthalpy-based conditional moment closure (CMC) model for homogeneous charge compression ignition (HCCI) with temperature inhomogeneity. The focus of study is placed on the effects of a conditioning variable on the prediction of heat release rates and developing the mixing models for sensible enthalpy, a reacting scalar. The sensible-enthalpy-based CMC model is validated a priori with 2-D direct numerical simulation (DNS) data for HCCI, and compared with the total-enthalpy-based formulation. Sensible enthalpy is shown to be strongly correlated with temperature, which makes sensible enthalpy well suited for a conditioning variable in CMC for HCCI. Results show that sensible-enthalpy-based CMC performs well for the prediction of heat release rates for all temperature stratification levels investigated in this study, while total-enthalpy-based CMC leads to the overprediction of heat release rates when the temperature stratification level is high. While conditional fluctuations of species mass fractions are substantial, sensible-enthalpy-based CMC is found to accurately estimate heat release rates during ignition, as well as reaction rates of key species, due to substantially suppressed conditional temperature fluctuations. The mapping closure models for the probability density function (PDF) and conditional dissipation rates of sensible enthalpy are proposed. The proposed models are found to capture the characteristics of reactive scalar mixing.

42 ENGINEERING↗

Spectroscopic Inversions of the Ca ii 8542 Å Line in a C-class Solar Flare

We study the C8.4-class solar flare SOL2016-05-14T11:34 UT using high-resolution spectral imaging in the Ca ii 8542 Å line obtained with the CRISP imaging spectropolarimeter on the Swedish 1 m Solar Telescope. Spectroscopic inversions of the Ca ii 8542 Å line using the non-LTE code NICOLE are used to investigate the evolution of the temperature and velocity structure in the flaring chromosphere. A comparison of the temperature stratification in flaring and non-flaring areas reveals strong footpoint heating during the flare peak in the lower atmosphere. The temperature of the flaring footpoints between log τ{sub 500} ≈−2.5 and −3.5, where τ {sub 500} is the continuum optical depth at 500 nm, is ∼5--6.5 kK close to the flare peak, reducing gradually to ∼5 kK. The temperature in the middle and upper chromosphere, between log τ{sub 500}≈−3.5 and −5.5, is estimated to be ∼6.5–20 kK, decreasing to preflare temperatures, ∼5–10 kK, after approximately 15 minutes. However, the temperature stratification of the non-flaring areas is unchanged. The inverted velocity fields show that the flaring chromosphere is dominated by weak downflowing condensations at the formation height of Ca ii 8542 Å.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Mesoscale Model Setups for Offshore Wind Resource Assessment: A New Jersey Case Study

As the offshore wind energy industry begins to emerge on the U.S. northeast coast, there is an urgent need for an accurate characterization of the offshore wind resource. The offshore regime features various resource characteristics not seen onshore, including frequent coastal low-level jets, non-steady surface conditions (e.g. waves), complex air-sea and land-sea interactions, and coastal mesoscale circulations (e.g. sea breeze). An accurate characterization of these phenomena in mesoscale models is critical to support accurate energy production estimates and forecasting for future offshore wind farms. However, a robust validation of mesoscale model performance in the offshore U.S. has been limited due to sparse data and difficulty obtaining offshore measurements. Consequently, it is unclear how mesoscale models perform offshore and which suite of parameterizations and input data are best suited for accurate resource characterization. To begin addressing this knowledge gap, the National Renewable Energy Laboratory, in collaboration with the Rutgers Center for Ocean Observing Leadership, conducted a mesoscale model validation campaign in the offshore environment. The Weather Research and Forecasting (WRF) model was assessed and the New Jersey offshore coastal area served as the validation domain. An ensemble of WRF simulations conducted over a one-year period sampled from a range of model setups, including different reanalysis and forecast data inputs, sea surface temperature data inputs, planetary boundary layer parameterizations, and WRF versions. The performance of each ensemble member was validated against a network of observations including offshore floating lidars, coastal met towers, offshore platform measurements, and offshore buoys. Model performance was assessed on annual, seasonal, and diurnal scales with particular emphasis on the vertical wind speed profile and temperature stratification. Preliminary results from this validation work will be presented here. The key WRF inputs and parameters driving changes in the modeled wind resource will be discussed and preliminary recommendations on WRF setups for offshore wind resource modeling will be proposed. The application of this validation exercise to other proposed offshore wind energy areas in the U.S. will also be discussed. mesoscale circulations (e.g. sea breeze). An accurate characterization of these phenomena in mesoscale models is critical to support accurate energy production estimates and forecasting for future offshore wind farms. However, a robust validation of mesoscale model performance in the offshore U.S. has been limited due to sparse data and difficulty obtaining offshore measurements. Consequently, it is unclear how mesoscale models perform offshore and which suite of parameterizations and input data are best suited for accurate resource characterization. To begin addressing this knowledge gap, the National Renewable Energy Laboratory, in collaboration with the Rutgers Center for Ocean Observing Leadership, conducted a mesoscale model validation campaign in the offshore environment. The Weather Research and Forecasting (WRF) model was assessed and the New Jersey offshore coastal area served as the validation domain. An ensemble of WRF simulations conducted over a one-year period sampled from a range of model setups, including different reanalysis and forecast data inputs, sea surface temperature data inputs, planetary boundary layer parameterizations, and WRF versions. The performance of each ensemble member was validated against a network of observations including offshore floating lidars, coastal met towers, offshore platform measurements, and offshore buoys. Model performance was assessed on annual, seasonal, and diurnal scales with particular emphasis on the vertical wind speed profile and temperature stratification. Preliminary results from this validation work will be presented here. The key WRF inputs and parameters driving changes in the modeled wind resource will be discussed and preliminary recommendations on WRF setups for offshore wind resource modeling will be proposed. The application of this validation exercise to other proposed offshore wind energy areas in the U.S. will also be discussed.

17 WIND ENERGY↗

Experimentally-determined characteristics of radiant systems for office buildings

Radiant heating and cooling systems have significant energy-saving potential and are gaining popularity in commercial buildings. The main aim of the experimental study reported here was to characterize the behavior of radiant cooling systems in a typical office environment, including the effect of ceiling fans on stratification, the variation in comfort conditions from perimeter to core, control on operative temperature vs. air temperature and the effect of carpet on cooling capacity. The goal was to limit both the first cost and the perceived risk associated with such systems. Two types of radiant systems, the radiant ceiling panel (RCP) system and the radiant slab (RS) system, were investigated. The experiments were carried out in one of the test cells that constitute the FLEXLAB test facility at the Lawrence Berkeley National Laboratory in March and April 2016. In total, ten test cases (five for RCP and five for RS) were performed, covering a range of operational conditions. In cooling mode, the air temperature stratification is relatively small in the RCP, with a maximum value of 1.6 K. The observed stratification effect was significantly greater in the RS, twice as much as that in the RCP. The maximum increase in dry bulb temperature in the perimeter zone due to solar radiation was 1.2 K for RCP and 0.9 K for RS – too small to have a significant impact on thermal comfort. The use of ceiling fans was able to reduce any excess stratification and provide better indoor comfort, if required. The use of thin carpet requires a 1 K lower supply chilled water temperature to compensate for the added thermal resistance, somewhat reducing the opportunities for water-side free cooling and increasing the risk of condensation. In both systems, the difference between the room operative temperature and the room air temperature is small when the cooling loads are met by the radiant systems. In conclusion, this makes it possible to use the air temperature to control the radiant systems in lieu of the operative temperature, reducing both first cost and maintenance costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical investigation of spontaneous flame propagation under RCCI conditions

This paper presents results from one and two-dimensional direct numerical simulations under Reactivity Controlled Compression Ignition (RCCI) conditions of a primary reference fuel (PRF) mixture consisting of n-heptane and iso-octane. RCCI uses in-cylinder blending of two fuels with different autoignition characteristics to control combustion phasing and the rate of heat release. These simulations employ an improved model of compression heating through mass source/sink terms developed in a previous work by Bhagatwala et al. (2014), which incorporates feedback from the flow to follow a predetermined experimental pressure trace. Two-dimensional simulations explored parametric variations with respect to temperature stratification, pressure profiles and n-heptane concentration. Furthermore, statistics derived from analysis of diffusion/reaction balances locally normal to the flame surface were used to elucidate combustion characteristics for the different cases. Both deflagration and spontaneous ignition fronts were observed to co-exist, however it was found that higher n-heptane concentration provided a greater degree of flame propagation, whereas lower n-heptane concentration (higher fraction of iso-octane) resulted in more spontaneous ignition fronts. A significant finding was that simulations initialized with a uniform initial temperature and a stratified n-heptane concentration field, resulted in a large fraction of combustion occurring through flame propagation. The proportion of spontaneous ignition fronts increased at higher pressures due to shorter ignition delay when other factors were held constant. For the same pressure and fuel concentration, the contribution of flame propagation to the overall combustion was found to depend on the level of thermal stratification, with higher initial temperature gradients resulting in more deflagration and lower gradients generating more ignition fronts. Statistics of ignition delay are computed to assess the Zel’dovich (1980) theory for the mode of combustion propagation based on ignition delay gradients.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solving the excitation and chemical abundances in shocks: The case of HH 1

We present deep spectroscopic (3600–24700 Å ) X-shooter observations of the bright Herbig–Haro object HH 1, one of the best laboratories to study the chemical and physical modifications caused by protostellar shocks on the natal cloud. We observe atomic fine structure lines, H i and He i recombination lines and H{sub 2} ro-vibrational lines (more than 500 detections in total). Line emission was analyzed by means of Non-local Thermal Equilibiurm codes to derive the electron temperature and density, and for the first time we are able to accurately probe different physical regimes behind a dissociative shock. We find a temperature stratification in the range 4000 K ÷ 80,000 K, and a significant correlation between temperature and ionization energy. Two density regimes are identified for the ionized gas, a more tenuous, spatially broad component (density ∼10{sup 3} cm{sup −3}), and a more compact component (density ⩾ 10{sup 5} cm{sup −3}) likely associated with the hottest gas. A further neutral component is also evidenced, having a temperature ≲10,000 K and a density >10{sup 4} cm{sup −3}. The gas fractional ionization was estimated by solving the ionization equilibrium equations of atoms detected in different ionization stages. We find that neutral and fully ionized regions co-exist inside the shock. Also, indications in favor of at least partially dissociative shock as the main mechanism for molecular excitation are derived. Chemical abundances are estimated for the majority of the detected species. On average, abundances of non-refractory/refractory elements are lower than solar of about 0.15/0.5 dex. This indicates the presence of dust inside the medium, with a depletion factor of iron of ∼40%.

79 ASTRONOMY AND ASTROPHYSICS↗

IRIS Burst Spectra Co-spatial to a Quiet-Sun Ellerman-like Brightening

Ellerman bombs (EBs) have been widely studied over the past two decades; however, only recently have the counterparts of these events been observed in the quiet-Sun. The aim of this article is to further understand small-scale quiet-Sun Ellerman-like brightenings (QSEBs) through research into their spectral signatures, including investigating whether the hot signatures associated with some EBs are also visible co-spatial to any QSEBs. We combine H α and Ca ii 8542 Å line scans at the solar limb with spectral and imaging data sampled by the Interface Region Imaging Spectrograph ( IRIS ). Twenty-one QSEBs were identified with average lifetimes, lengths, and widths measured to be around 120 s, 0.″63, and 0.″35, respectively. Three of these QSEBs displayed clear repetitive flaring through their lifetimes, comparable to the behavior of EBs in active regions. Two QSEBs in this sample occurred co-spatial to increased emission in SDO /AIA 1600 Å and IRIS slit-jaw imager 1400 Å data; however, these intensity increases were smaller than those reported co-spatially with EBs. One QSEB was also sampled by the IRIS slit during its lifetime, displaying increases in intensity in the Si iv 1393 Å and Si iv 1403 Å cores, as well as the C ii and Mg ii line wings, analogous to IRIS bursts (IBs). Using RADYN simulations, we are unable to reproduce the observed QSEB H α and Ca ii 8542 Å line profiles, leaving the question of the temperature stratification of QSEBs open. Our results imply that some QSEBs could be heated to transition region temperatures, suggesting that IB profiles should be observed throughout the quiet-Sun.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating temperature and fuel stratification for heat-release rate control in a reactivity-controlled compression-ignition engine using optical diagnostics and chemical kinetics modeling

We investigated the combustion process in a dual-fuel, reactivity-controlled compression-ignition (RCCI) engine using a combination of optical diagnostics and chemical kinetics modeling to explain the role of equivalence ratio, temperature, and fuel reactivity stratification for heat-release rate control. An optically accessible engine is operated in the RCCI combustion mode using gasoline primary reference fuels (PRF). A well-mixed charge of iso-octane (PRF = 100) is created by injecting fuel into the engine cylinder during the intake stroke using a gasoline-type direct injector. Later in the cycle, n-heptane (PRF = 0) is delivered through a centrally mounted diesel-type common-rail injector. This injection strategy generates stratification in equivalence ratio, fuel blend, and temperature. The first part of this study uses a high-speed camera to image the injection events and record high-temperature combustion chemiluminescence. Moreover, the chemiluminescence imaging showed that, at the operating condition studied in the present work, mixtures in the squish region ignite first, and the reaction zone proceeds inward toward the center of the combustion chamber. The second part of this study investigates the charge preparation of the RCCI strategy using planar laser-induced fluorescence (PLIF) of a fuel tracer under non-reacting conditions to quantify fuel concentration distributions prior to ignition. The fuel-tracer PLIF data show that the combustion event proceeds down gradients in the n-heptane distribution. The third part of the study uses chemical kinetics modeling over a range of mixtures spanning the distributions observed from the fuel-tracer fluorescence imaging to isolate the roles of temperature, equivalence ratio, and PRF number stratification. The simulations predict that PRF number stratification is the dominant factor controlling the ignition location and growth rate of the reaction zone. Equivalence ratio has a smaller, but still significant, influence. Lastly, temperature stratification had a negligible influence due to the NTC behavior of the PRF mixtures.

42 ENGINEERING↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FULLY RESOLVED QUIET-SUN MAGNETIC FLUX TUBE OBSERVED WITH THE SUNRISE/IMAX INSTRUMENT

Until today, the small size of magnetic elements in quiet-Sun areas has required the application of indirect methods, such as the line-ratio technique or multi-component inversions, to infer their physical properties. A consistent match to the observed Stokes profiles could only be obtained by introducing a magnetic filling factor that specifies the fraction of the observed pixel filled with magnetic field. Here, we investigate the properties of a small magnetic patch in the quiet Sun observed with the IMaX magnetograph on board the balloon-borne telescope SUNRISE with unprecedented spatial resolution and low instrumental stray light. We apply an inversion technique based on the numerical solution of the radiative transfer equation to retrieve the temperature stratification and the field strength in the magnetic patch. The observations can be well reproduced with a one-component, fully magnetized atmosphere with a field strength exceeding 1 kG and a significantly enhanced temperature in the mid to upper photosphere with respect to its surroundings, consistent with semi-empirical flux tube models for plage regions. We therefore conclude that, within the framework of a simple atmospheric model, the IMaX measurements resolve the observed quiet-Sun flux tube.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY EMISSION FROM MAGNETIC MASSIVE STARS

Magnetically confined winds of early-type stars are expected to be sources of bright and hard X-rays. To clarify the systematics of the observed X-ray properties, we have analyzed a large series of Chandra and XMM-Newton observations, corresponding to all available exposures of known massive magnetic stars (over 100 exposures covering ∼60% of stars compiled in the catalog of Petit et al.). We show that the X-ray luminosity is strongly correlated with the stellar wind mass-loss rate, with a power-law form that is slightly steeper than linear for the majority of the less luminous, lower- M-dot B stars and flattens for the more luminous, higher- M-dot O stars. As the winds are radiatively driven, these scalings can be equivalently written as relations with the bolometric luminosity. The observed X-ray luminosities, and their trend with mass-loss rates, are well reproduced by new MHD models, although a few overluminous stars (mostly rapidly rotating objects) exist. No relation is found between other X-ray properties (plasma temperature, absorption) and stellar or magnetic parameters, contrary to expectations (e.g., higher temperature for stronger mass-loss rate). This suggests that the main driver for the plasma properties is different from the main determinant of the X-ray luminosity. Finally, variations of the X-ray hardnesses and luminosities, in phase with the stellar rotation period, are detected for some objects and they suggest that some temperature stratification exists in massive stars' magnetospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

OPTICALLY THICK H I DOMINANT IN THE LOCAL INTERSTELLAR MEDIUM: AN ALTERNATIVE INTERPRETATION TO ''DARK GAS''

Dark gas in the interstellar medium (ISM) is believed to not be detectable either in CO or H I radio emission, but it is detectable by other means including γ rays, dust emission, and extinction traced outside the Galactic plane at |b| > 5°. In these analyses, the 21 cm H I emission is usually assumed to be completely optically thin. We have reanalyzed the H I emission from the whole sky at |b| > 15° by considering temperature stratification in the ISM inferred from the Planck/IRAS analysis of the dust properties. The results indicate that the H I emission is saturated with an optical depth ranging from 0.5 to 3 for 85% of the local H I gas. This optically thick H I is characterized by spin temperature in the range 10 K-60 K, significantly lower than previously postulated in the literature, whereas such low temperature is consistent with emission/absorption measurements of the cool H I toward radio continuum sources. The distribution and the column density of the H I are consistent with those of the dark gas suggested by γ rays, and it is possible that the dark gas in the Galaxy is dominated by optically thick cold H I gas. This result implies that the average density of H I is 2-2.5 times higher than that derived on the optically thin assumption in the local ISM.

79 ASTRONOMY AND ASTROPHYSICS↗

A three-dimensional view of the thermal structure in a super-penumbral canopy

We investigate the three-dimensional (3D) thermal topology in a super-penumbral canopy of an active region (AR). We derive temperature stratifications in the AR by an inversion of the Ca II IR line at 854.2 nm, assuming local thermal equilibrium. We find that about half of the radially oriented fibrils in the super-penumbral canopy form short, low-lying (h < 1 Mm) loops in the 3D temperature cube. These closed loops connect from bright grains in or close to the penumbra to the photosphere a few Mms away from the sunspot. The other half of the fibrils monotonically rise with distance from the sunspot. Many of the fibrils show a central dark core and two lateral brightenings in line-core intensity images. The corresponding velocity image shows fibrils that are as wide as the fibrils seen in intensity without a lateral substructure. Additionally, we study a feature from a different class of structures without prominent mass flows. Its 3D topology is formed by two parallel, closed loops that connect patches of opposite polarity. We present evidence that the inverse Evershed flow into the sunspot in the lower chromosphere is the consequence of siphon flows along short loops that connect photospheric foot points. The dark-cored structure of the chromospheric fibrils cannot have a convective origin because of their location above regular granulation. The dark core most likely results from an opacity difference between the central axis and the lateral edges caused by the significant flow speed along the fibrils.

79 ASTRONOMY AND ASTROPHYSICS↗

NEW SCALING FOR THE ALPHA EFFECT IN SLOWLY ROTATING TURBULENCE

Using simulations of slowly rotating stratified turbulence, we show that the {alpha} effect responsible for the generation of astrophysical magnetic fields is proportional to the logarithmic gradient of kinetic energy density rather than that of momentum, as was previously thought. This result is in agreement with a new analytic theory developed in this paper for large Reynolds numbers and slow rotation. Thus, the contribution of density stratification is less important than that of turbulent velocity. The {alpha} effect and other turbulent transport coefficients are determined by means of the test-field method. In addition to forced turbulence, we also investigate supernova-driven turbulence and stellar convection. In some cases (intermediate rotation rate for forced turbulence, convection with intermediate temperature stratification, and supernova-driven turbulence), we find that the contribution of density stratification might be even less important than suggested by the analytic theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Stronger Tropical Cyclone–Induced Ocean Cooling in Near-Coastal Regions Compared to the Open Ocean

Abstract Tropical cyclones (TC) often induce strong mixing in the upper ocean that generates a trail of cooler sea surface temperature (Twake) in their wakes. The Twake can affect TC intensity, so its prediction is important, especially in coastal regions where TCs can make landfall. Coastal Twakes are often more complex than those in the open ocean due to the influences of coastline geometry, highly variable water depth, continental runoff, and shelf processes. Using observational data since 2002, here we show a significantly stronger global mean Twake in coastal regions compared to offshore regions. Temperature stratification is the main driver of stronger coastal Twakes in the North Atlantic and east Pacific. In the northwest Pacific and north Indian Ocean, the differences between coastal and offshore Twakes are smaller due to compensation between TC forcings and ocean stratification. The north Indian Ocean is unique in the Northern Hemisphere because salinity stratification plays a major role on the spatial distribution of Twake. In the South Pacific Ocean, TC intensity and translation speed are crucial for explaining coastal–offshore Twake differences, while ocean stratification and mixed layer depth are more important for the coastal–offshore Twake differences in the south Indian Ocean. These findings suggest that coastal–offshore differences in ocean stratification need to be properly represented in models in order to capture changes in TC-induced ocean cooling as storms approach landfall. Significance Statement Landfalling tropical cyclones (TCs) often cause considerable damage in coastal regions with dense human populations. Understanding TC–ocean interaction and how it differs between coastal and offshore regions can help predict TC intensity prior to landfall. Sea surface cooling after TC passage is an important proxy for TC–ocean interaction. A global evaluation of coastal TC-induced cooling has not been conducted. Using data covering two decades, we show significantly stronger TC-induced surface cooling in coastal regions compared to offshore regions at the global scale and in all basins except the northwest Pacific and north Indian Ocean. The difference is driven mainly by upper-ocean conditions in the North Atlantic, east Pacific, and south Indian Ocean, and by TC characteristics in the South Pacific.

54 ENVIRONMENTAL SCIENCES↗