Results for “Tcl”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

New Software Architecture Options for the TCL Data Acquisition System

The Turbulent Combustion Laboratory (TCL) conducts research on combustion in turbulent flow environments. To conduct this research, the TCL utilizes several pulse lasers, a traversable wind tunnel, flow controllers, scientific grade CCD cameras, and numerous other components. Responsible for managing these different data-acquiring instruments and data processing components is the Data Acquisition (DAQ) software. However, the current system is constrained to running through VXI hardware—an instrument-computer interface—that is several years old, requiring the use of an outdated version of the visual programming language, LabVIEW. A new Acquisition System is being programmed which will borrow heavily from either a programming model known as the Current Value Table (CVT) System or another model known as the Server-Client System. The CVT System model is in essence, a giant spread sheet from which data or commands may be retrieved or written to, and the Server-Client System is based on network connections between a server and a client, very much like the Server-Client model of the Internet. Currently, the bare elements of a CVT DAQ Software have been implemented, consisting of client programs in addition to a server program that the CVT will run on. This system is being rigorously tested to evaluate the merits of pursuing the CVT System model and to uncover any potential flaws which may result in further implementation. If the CVT System is chosen, which is likely, then future work will consist of build up the system until enough client programs have been created to run the individual components of the lab. The advantages of such a System will be flexibility, portability, and polymorphism. Additionally, the new DAQ software will allow the Lab to replace the VXI with a newer instrument interface—the PXI—and take advantage of the capabilities of current and future versions of LabVIEW.

97 MATHEMATICS AND COMPUTING↗

COHORT: Coordination of Heterogeneous Thermostatically Controlled Loads for Demand Flexibility

Demand flexibility is increasingly important for power grids. Careful coordination of thermostatically controlled loads (TCLs) can modulate energy demand, decrease operating costs, and increase grid resiliency. We propose a novel distributed control framework for the Coordination Of HeterOgeneous Residential Thermostatically controlled loads (COHORT). COHORT is a practical, scalable, and versatile solution that coordinates a population of TCLs to jointly optimize a grid-level objective, while satisfying each TCL’s end-use requirements and operational constraints. To achieve that, we decompose the grid-scale problem into subproblems and coordi- nate their solutions to find the global optimum using the alternating direction method of multipliers (ADMM). The TCLs’ local problems are distributed to and computed in parallel at each TCL, making COHORT highly scalable and privacy-preserving. While each TCL poses combinatorial and non-convex constraints, we characterize these constraints as a convex set through relaxation, thereby making COHORT computationally viable over long planning horizons. After coordination, each TCL is responsible for its own control and tracks the agreed-upon power trajectory with its preferred strategy. In this work, we translate continuous power back to discrete on/off actuation, using pulse width modulation. COHORT is generalizable to a wide range of grid objectives, which we demonstrate through three distinct use cases: generation following, minimizing ramping, and peak load curtailment. In a notable experiment, we validated our approach through a hardware-in-the-loop simulation, including a real-world air conditioner (AC) controlled via a smart thermostat, and simulated instances of ACs modeled after real-world data traces. During the 15-day experimental period, COHORT reduced daily peak loads by an average of 12.5% and maintained comfortable temperatures.

demand response↗

Corrosion of 316H stainless steel in flowing FLiNaK salt

In this report type 316H stainless steel samples were exposed to flowing FLiNaK salt for 1000 h in a monometallic thermal convection loop (TCL) with a maximum temperature of 650 °C and a minimum of 540 °C. Samples in the hottest part of the TCL lost mass, with a maximum mass loss of 1.4 mg/cm 2 , while samples in the coldest parts of the TCL gained mass, with a maximum mass gain of 1.0 mg/cm 2 . Analysis of the samples that gained mass showed an Fe-rich layer on the sample surfaces, indicating that Fe, not Cr, was the primary deposition product in the TCL. Cr loss was apparent to a depth of ~5 µm in the hot leg. Post-exposure analysis of the salt showed major increases in the Cr, Fe, and Mn contents. The TCL was modeled using the TRANSFORM code. Modeled values matched the experimental temperature measurements showing that TRANSFORM is capable of accurately simulating the TCL conditions.

36 MATERIALS SCIENCE↗

Exact calculation of the time convolutionless master equation generator: Application to the nonequilibrium resonant level model

The generalized quantum master equation provides a powerful tool to describe the dynamics in quantum impurity models driven away from equilibrium. Two complementary approaches, one based on Nakajima–Zwanzig–Mori time-convolution (TC) and the other on the Tokuyama–Mori time-convolutionless (TCL) formulations provide a starting point to describe the time-evolution of the reduced density matrix. A key in both approaches is to obtain the so called “memory kernel” or “generator,” going beyond second or fourth order perturbation techniques. While numerically converged techniques are available for the TC memory kernel, the canonical approach to obtain the TCL generator is based on inverting a super-operator in the full Hilbert space, which is difficult to perform and thus, nearly all applications of the TCL approach rely on a perturbative scheme of some sort. Here, the TCL generator is expressed using a reduced system propagator which can be obtained from system observables alone and requires the calculation of super-operators and their inverse in the reduced Hilbert space rather than the full one. This makes the formulation amenable to quantum impurity solvers or to diagrammatic techniques, such as the nonequilibrium Green’s function. We implement the TCL approach for the resonant level model driven away from equilibrium and compare the time scales for the decay of the generator with that of the memory kernel in the TC approach. Furthermore, the effects of temperature, source-drain bias, and gate potential on the TCL/TC generators are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progression to Compatibility Evaluations in Flowing Molten Salts

Molten salt compatibility with structural alloys has been identified as a key issue for the development of Generation 3 concentrating solar power (CSP) systems with thermal storage. To accelerate this evaluation to pumped systems, the goal of this project was to conduct thermal convection loop (TCL) experiments with a peak temperature of ≥700°C and a typical temperature gradient of ~100°C. The experiments indicated that conventional ~16wt.%Cr Ni-based alloys are compatible up to 700°C with purified (i.e. low O) or dried (low H₂O) industrial-sourced Mg-K-Na chloride salt with <10 μm/yr loss. This two-year project was conducted based on the experimental and mechanistic understanding developed more than 60 years ago at Oak Ridge National Laboratory (ORNL). The first TCL experiment met the <15 μm/yr corrosion metric for this project with specimens of Ni-based alloy 600 exposed at 580°-700°C for 1000 h and post-exposure room temperature tensile tests showed minimal degradation. The second TCL experiment successfully deployed an electrochemical sensor from Argonne National Laboratory and had a peak temperature of 750°C but only ran for ~110 h due to a furnace failure. Both experiments used highly purified industrial-sourced salt with an O content of ~3 μg O/g salt and a Mg addition of 0.04 wt.%. In the second year, the Chloride Collective developed a more economical drying procedure such that the O content was much higher (>20,000 μg O/g salt). A third TCL experiment was conducted with a sensor and a peak temperature of 700°C using dried salt from the same industrial source and increased NaCl content (~20 wt.%). In addition to a 0.05% Mg addition to the salt, a Mg coupon was added in the coldest part of the loop which dissolved during the experiment. Again, small mass changes were noted for specimens of alloys 600 and C276 but the values were slightly higher than those measured in purified salt with Mg. A thin non-continuous and non-adherent oxide layer was deposited on most specimens containing Mg, Si and Al but Cr depletion also was observed. Both years included facilities qualification crucible experiments and then capsule experiments to confirm a baseline isothermal reaction rate. The first year capsule experiment led to the conclusion that the two-stage ORNL purification process using NH₄Cl and CCl₄ left the salt with a high Cl potential and a Mg addition (~0.05wt.%) was needed to lower the potential. The second year capsule experiments at 600° and 700°C found little difference in depth of attack for 0-0.25%Mg additions. In general, the complex reactions where salt can be trapped in the porous surface layer of metal indicated that mass change is an unreliable metric and average depth of Cr depletion is a better metric for assessing the extent of attack. These results have created a new baseline that is contrary to the recent published literature for chloride salts where mass losses have been reported that can be extrapolated to very significant annual metal loss rates. Chloride salt corrosion can be controlled and the results also indicate that salt purification to low O levels may not be necessary. However, additional TCL experiments are needed at different times and temperatures to generate important engineering information such as temperature dependent corrosion rates and reaction rate laws for extrapolation to long-term behavior and isolate the effect of salt additives and impurities.

36 MATERIALS SCIENCE↗

Improving Miscibility of Polymer Donor and Polymer Acceptor by Reducing Chain Entanglement for Realizing 18.64 % Efficiency All Polymer Solar Cells

All-polymer solar cells have experienced rapid development in recent years by the emergence of polymerized small molecular acceptors (PSMAs). However, the strong chain entanglements of polymer donors (P D s) and polymer acceptors (P A s) decrease the miscibility of the resulting polymer mixtures, making it challenging to optimize the blend morphology. Herein, we designed three P A s, namely PBTPICm-BDD, PBTPICγ-BDD and PBTPICF-BDD, by smartly using a BDD unit as the polymerized unit to copolymerize with different Y-typed non-fullerene small molecular acceptors (NF-SMAs), thus achieving a certain degree of distortion and giving the polymer system enough internal space to reduce the entanglements of the polymer chains. Such effects increase the chances of the P D being interspersed into the acceptor material, which improve the solubility between the P D and P A . The PBTPICγ-BDD and PBTPICF-BDD displayed better miscibility with PBQx-TCl, leading to a well optimized morphology. As a result, high power conversion efficiencies (PCEs) of 17.50 % and 17.17 % were achieved for PBQx-TCl : PBTPICγ-BDD and PBQx-TCl : PBTPICF-BDD devices, respectively. In conclusion, with the addition of PYFT-o as the third component into PBQx-TCl : PBTPICγ-BDD blend to further extend the absorption spectral coverage and finely tune microstructures of the blend morphology, a remarkable PCE of 18.64 % was realized finally.

36 MATERIALS SCIENCE↗

Evaluation of the interaction between SiC, pre-oxidized FeCrAlMo with aluminized and pre-oxidized Fe-8Cr-2W in flowing PbLi

We report dissimilar materials interactions are a major concern when liquid metals are used as a working fluid. To simulate a dual-coolant PbLi blanket, chemical vapor deposited (CVD) SiC, pre-oxidized FeCrAlMo (APMT) and pre-oxidized aluminized coating on Fe-8Cr-2 W (F82H) specimens were exposed to flowing commercial Pb-17at.%Li with a peak temperature of 650 °C in a pre-oxidized APMT thermal convection loop (TCL) for 1000 h. Similar to prior results in static PbLi, the coated F82H showed small mass changes and limited degradation of room-temperature tensile properties. After exposure, the α-Al 2 O 3 on the surface coated F82H reacted with the PbLi to form LiAlO 2 . However, no significant Al coating loss or interdiffusion was observed. Mass transfer was observed between the APMT, TCL and the SiC specimens. Fe, Cr and Ni were dissolved into the molten flowing PbLi and transported through the TCL to react with the SiC specimens. Compared to a prior experiment with a majority of bare FeCrAl specimens that were exposed in a TCL with a peak temperature of 700 °C for 1000 h, the SiC reaction was reduced to only a few microns of carbides and silicides. Oxygen dissolved in the molten PbLi sustained the formation of an Al 2 O 3 scale on the surface of the coating and induced the formation of a thin surface SiO 2 layer on the surface of the SiC.

36 MATERIALS SCIENCE↗

Percutaneous Ultrasound-Guided Carpal Tunnel Release: Study Upon Clinical Efficacy and Safety

ObjectivesTo evaluate the feasibility and 6 months clinical result of sectioning of the transverse carpal ligament (TCL) and median nerve decompression after ultra-minimally invasive, ultrasound-guided percutaneous carpal tunnel release (PCTR) surgery.MethodsConsecutive patients with carpal tunnel syndrome were enrolled in this descriptive, open-label study. The procedure was performed in the interventional radiology room. Magnetic resonance imaging was performed at baseline and 1 month. The Boston Carpal Tunnel Questionnaire was administered at baseline, 1, and 6 months.Results129 patients were enrolled. Significant decreases in mean symptom severity scores (3.3 ± 0.7 at baseline, 1.7 ± 0.4 at Month 1, 1.3 ± 0.3 at Month 6) and mean functional status scores (2.6 ± 1.1 at baseline, 1.6 ± 0.4 at Month 1, 1.3 ± 0.5 at Month 6) were noted. Magnetic resonance imaging showed a complete section of all TCL and nerve decompression in 100% of patients. No complications were identified.ConclusionsUltrasound-guided PCTR was used successfully to section the TCL, decompress the median nerve, and reduce self-reported symptoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A phase model approach for thermostatically controlled load demand response

A significant portion of electricity consumed worldwide is used to power thermostatically controlled loads (TCLs) such as air conditioners, refrigerators, and water heaters. Because the short-term timing of operation of such systems is inconsequential as long as their long-run average power consumption is maintained, they are increasingly used in demand response (DR) programs to balance supply and demand on the power grid. Here, we present an ab initio phase model for general TCLs, and use the concept to develop a continuous oscillator model of a TCL and compute its phase response to changes in temperature and applied power. This yields a simple control system model that can be used to evaluate control policies for modulating the power consumption of aggregated loads with parameter heterogeneity and stochastic drift. We demonstrate this concept by comparing simulations of ensembles of heterogeneous loads using the continuous state model and an established hybrid state model. The developed phase model approach is a novel means of evaluating DR provision using TCLs, and is instrumental in estimating the capacity of ancillary services or DR on different time scales. We further propose a novel phase response based open-loop control policy that effectively modulates the aggregate power of a heterogeneous TCL population while maintaining load diversity and minimizing power overshoots. This is demonstrated by low-error tracking of a regulation signal by filtering it into frequency bands and using TCL sub-ensembles with duty cycles in corresponding ranges. As a result, control policies that can maintain a uniform distribution of power consumption by aggregated heterogeneous loads will enable distribution system management (DSM) approaches that maintain stability as well as power quality, and further allow more integration of renewable energy sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Compatibility of SiC with ODS FeCrAl in flowing Pb-Li at 600° - 700°C

To establish the maximum operating temperature for the dual coolant lead lithium (DCLL) blanket concept, thermal convection loop (TCL) experiments were conducted for 1000 h with a peak temperature of 700 °C to determine compatibility with commercial eutectic Pb~17at.%Li. Two TCLs were fabricated from alloy APMT (FeCrAlMo) and the baseline TCL experiment contained only APMT specimens. The second TCL experiment exposed more fusion relevant CVD SiC and ODS Fe-10Cr-6Al specimens in the hot and cold legs. In the second experiment, the mass losses were much larger for the ODS FeCrAl specimens and most of the CVD SiC specimens experienced a mass gain as SiC reacted to form an Fe- and Cr-rich carbide reaction product. Dissolved Fe and Cr reacted with the SiC and removing Fe and Cr from the liquid appeared to increase ODS FeCrAl dissolution. Such a dissimilar material interaction appears consistent with thermodynamic calculations. Significant attack at the top of the hot leg in both experiments suggests that the Pb-Li compatibility of FeCrAl alloys is inadequate at 700 °C in a flowing environment and the maximum PbLi temperature is < 675 °C.

36 MATERIALS SCIENCE↗

Compatibility of an FeCrAl alloy with flowing Pb-Li in a thermal convection loop

A mono-metallic thermal convection loop (TCL) fabricated from alloy APMT (Fe21Cr5Al3Mo) tubing and filled with 0.025 m long tensile specimens of the same alloy was operated continuously for 1000 h with commercially pure Pb-17 at.%Li (Pb-Li) at a peak temperature of 550 ± 1.5 °C and a temperature gradient of ~116 °C. The resulting Pb-Li flow rate was ~0.0067 m/s. A 1050 °C pre-oxidation treatment (to form an external alumina scale) given to most specimens exposed within the TCL decreased total mass loss by a factor of 3–30 compared to adjacent specimens that were not pre-oxidized. However, all specimens exposed above 500 °C lost mass suggesting that the alumina scale was not entirely stable in flowing Pb-Li at these temperatures. Post-exposure room temperature tensile tests indicated that the mechanical properties of APMT were substantially influenced by extended exposures in the range of 435–490 °C, which caused an increase in yield strength (~65%) and a corresponding decrease in ductility associated with α' embrittlement. Specimens annealed in argon at the same temperature exhibited identical changes without exposure to Pb-Li. In conclusion, scanning transmission electron microscopy revealed Cr-clusters within the microstructure in specimens exposed in the low temperature regions (<490 °C) of the TCL, indicating the formation of α' consistent with the mechanism of α' embrittlement.

36 MATERIALS SCIENCE↗

Psychrophilic dry anaerobic digestion of dairy cow feces: Long-term operation

Highlights: • Psychrophilic dry anaerobic digestion (PDAD) of cow feces (CF) is feasible. • PDAD of CF is as efficient as mesophilic and thermophilic AD at TCL 21 days. • CF (13–16% TS at OLR 5.0 g TCOD{sub fed} kg{sup −1} inoculum d{sup −1}) yielded 222 ± 27 {sub N}L CH{sub 4} kg{sup −1} VS fed. - Abstract: This paper reports experimental results which demonstrate psychrophilic dry anaerobic digestion of cow feces during long-term operation in sequence batch reactor. Cow feces (13–16% total solids) has been anaerobically digested in 12 successive cycles (252 days) at 21 days treatment cycle length (TCL) and temperature of 20 °C using psychrotrophic anaerobic mixed culture. An average specific methane yield (SMY) of 184.9 ± 24.0, 189.9 ± 27.3, and 222 ± 27.7 {sub N}L CH{sub 4} kg{sup −1} of VS fed has been achieved at an organic loading rate of 3.0, 4.0, and 5.0 g TCOD kg{sup −1} inoculum d{sup −1} and TCL of 21 days, respectively. The corresponding substrate to inoculum ratio (SIR) was 0.39 ± 0.06, 0.48 ± .02, 0.53 ± 0.05, respectively. Average methane production rate of 10 ± 1.4 {sub N}L CH{sub 4} kg{sup −1} VS fed d{sup −1} has been obtained. The low concentration of volatile fatty acids indicated that hydrolysis was the reaction limiting step.

09 BIOMASS FUELS↗

The Importance of Capturing Topographic Features for Modeling Groundwater Flow and Transport in Mountainous Watersheds

Abstract Physics‐based distributed hydrological models that include groundwater are widely used to understand and predict physical and biogeochemical processes within watersheds. Typically, due to computational limitations, watershed modelers minimize the number of elements used in domain discretization, smoothing or even ignoring critical topographic features. We use an idealized model to investigate the implications of mesh refinement along streams and ridges for modeling three‐dimensional groundwater flow and transport in mountainous watersheds. For varying degrees of topographic complexity level (TCL), which increases with the level of mesh refinement, and geological heterogeneity, we estimate and compare steady state baseflow discharge, mean age, and concentration of subsurface weathering products. Results show that ignoring lower‐order streams or ridges diminishes flow through local flow paths and biases higher the contribution of intermediate and regional flow paths, and biases baseflow older. The magnitude of the bias increases for systems where permeability rapidly decreases with depth and is dominated by shallow flow paths. Based on a simple geochemical model, the concentration of weathering products is less sensitive to the TCL, partially due to the thermodynamic constraints on chemical reactions. Our idealized model also reproduces the observed emergent scaling relationship between the groundwater contribution to streamflow and drainage area, and finds that this scaling relationship is not sensitive to mesh TCL. The bias effects have important implications for the use of hydrological models in the interpretation of environmental tracer data and the prediction of biogeochemical evolution of stream water in mountainous watersheds.

Wang, Chao↗

Mitigated Dissimilar Mass Transfer with Aluminized RAFM Steels in Flowing PbLi at 650°C

To evaluate dissimilar material interactions in flowing eutectic Pb-16at. %Li between fusion-relevant materials and to establish a maximum operating temperature of future blanket designs, a series of thermal convection loop (TCL) experiments with flowing PbLi have been conducted. Following a 1000-h, 550°C to 650°C TCL experiment, a thin reaction product was observed on the surface of monolithic, high-purity SiC. To identify the source of the observed dissimilar material interaction and to understand the reaction kinetics, an identical 2000-h TCL exposure was conducted, but less reaction of the SiC specimen was observed. Characterization of the FeCrAlMo (alloy APMT) loop tubing and the PbLi-exposed austenitic stainless steel (SS) assembly parts suggested that the formation of the reaction layer on the surface of the PbLi-exposed SiC did not originate from the coated reduced activation ferritic martensitic (RAFM) steel, but from the dissolved loop materials (liquid metal exposed APMT tubing and type 316 SS fittings). Here, the results, after 2000 h, suggest that the dissimilar material reaction between the Al-coated RAFM steel and the SiC has very slow reaction kinetics within a temperature gradient of 550°C to 650°C.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of a Zirconium Recycle Scrubber System

A hot-cell demonstration of the zirconium recycle process is planned as part of the Materials Recovery and Waste Forms Development (MRWFD) campaign. The process treats Zircaloy® cladding recovered from used nuclear fuel with chlorine gas to recover the zirconium as volatile ZrCl4. This releases radioactive tritium trapped in the alloy, converting it to volatile tritium chloride (TCl). To meet regulatory requirements governing radioactive emissions from nuclear fuel treatment operations, the capture and retention of a portion of this TCl may be required prior to discharge of the off-gas stream to the environment. In addition to demonstrating tritium removal from a synthetic zirconium recycle off-gas stream, the recovery and quantification of tritium may refine estimates of the amount of tritium present in the Zircaloy cladding of used nuclear fuel. To support these objectives, a bubbler-type scrubber was fabricated to remove the TCl from the zirconium recycle off-gas stream. The scrubber was fabricated from glass and polymer components that are resistant to chlorine and hydrochloric acid solutions. Because of concerns that the scrubber efficiency is not quantitative, tests were performed using DCl as a stand-in to experimentally measure the scrubbing efficiency of this unit. Scrubbing efficiency was ~108% ± 3% with water as the scrubber solution. Variations were noted when 1 M NaOH scrub solution was used, values ranged from 64% to 130%. The reason for the variations is not known. It is recommended that the equipment be operated with water as the scrubbing solution. Scrubbing efficiency is estimated at 100%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AlphaBuilding ResCommunity: A multi-agent virtual testbed for community-level load coordination

Training and validating algorithms in a simulation testbed can accelerate research and applications of optimal control of residential loads to improve energy flexibility and grid resilience. We developed an open-source simulation environment, AlphaBuilding ResCommunity, that can be used to train and validate algorithms to control a single thermostatically controlled load (TCL) or coordinate a group of TCLs. We used reduced-order models to simulate the thermodynamics of TCLs, and the parameter values were determined from the connected smart thermostat data of real households. The environment was built upon the standardized OpenAI Gym interface. Ancillary functions, such as retrieving the parameters and weather forecasts, are provided to facilitate control strategies that require predictive information. Compared with existing efforts, AlphaBuilding ResCommunity has three advantages: (1) more realistic model settings because the parameter values are identified from actual household operating data, and modelling and measurement uncertainty are considered; (2) passive thermal storage control; and (3) ease of use due to a simple software dependency and standardized interface. We demonstrated the applications of the environment by implementing a Kalman Filter and Model Predictive Control on a single TCL and a Priority-Stack-Based Control and Alternating Direction Method of Multipliers to coordinate multiple TCLs for load tracking.

Wang, Z↗

Simultaneously improved J sc and V oc achieving 19.15% efficiency in ternary blend polymer solar cell containing a Y-type acceptor with thiophene based end groups

Simultaneously enhancing the short-circuit current density (J sc ) and open-circuit voltage (V oc ) of current state-of-the-art polymer solar cells (PSCs) containing wide bandgap polymers as donors and Y6 derivatives as acceptors is of great challenge but essential for further improvement of the photovoltaic performances. Here, in this work, two Y-type non-fullerene acceptors of BTP-T and BTP-TCl were designed and successfully synthesized with relatively weak electron-accepting thiophene based end groups, where blue-shifted absorption and upshifted LUMO energy levels were achieved to fill the well-known absorption gap at 700 nm of typical binary devices based Y-type molecules and rise the output voltage, respectively. Simultaneously increased J sc and V oc were achieved in ternary blend devices containing D18:BTP-eC9:BTP-TCl with a significantly improved PCE up to 19.15 %, which is over 7 % increase compared to the binary device. Our results illustrated the great potential of rational design of Y6 derivatives for constructing ternary PSCs to improve their performances.

36 MATERIALS SCIENCE↗