Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TURBIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Combined Raman and Turbidity Probe for Real-Time Analysis of Variable Turbidity Streams

We know that real-time and in situ process monitoring is a powerful tool that can empower operators of hazardous processes to better understand and control their chemical systems without increased risk to themselves. However, applying monitoring techniques to complex chemical processes can face challenges. An example of this is the application of optical spectroscopy, otherwise capable of providing detailed chemical composition information, to processes exhibiting variable turbidity. Here, details on a novel combined Raman spectroscopy and turbidimetry probe are discussed. Furthermore, the analytical approach to accurately account for both Raman signal and turbidity while quantifying chemical targets is detailed. Through leveraging Raman and turbidity data simultaneously collected from the combined probe within chemometric models, accurate quantification of multiple chemical targets can be achieved under conditions of variable concentrations and turbidity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Opto-acoustic measurement of the local light absorption coefficient in turbid media: 2. On the possibility of light absorption coefficient measurement in a turbid medium from the amplitude of the opto-acoustic signal

The second part of this work describes the experimental technique of measuring the local light absorption in turbid media. The technique is based on the measurement of the amplitude of an opto-acoustic (OA) signal excited in a turbid medium under the condition of one-sided access to the object under study. An OA transducer is developed to perform the proposed measurement procedure. Experiments are conducted for the turbid media with different optical properties (light absorption and reduced scattering coefficients) and for different diameters of the incident laser beam. It is found that the laser beam diameter can be chosen so that the dependences of the measured OA signal amplitude on the light absorption coefficient coincide upon varying the reduced scattering coefficient by more than twice. The obtained numerical and experimental results demonstrate that the OA method is applicable for measuring the local light absorption coefficient in turbid media, for example, in biological tissues. (measurement of parametrs of laser radiation)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opto-acoustic measurement of the local light absorption coefficient in turbid media: 1. Monte-Carlo simulation of laser fluence distribution at the beam axis beneath the surface of a turbid medium

A new method for measuring the local light absorption coefficient in turbid media, for example, biological tissues, is proposed. The method is based on the fact that the amplitude of the excited opto-acoustic (OA) signal is proportional to the absorbed laser power density (the product of the light absorption coefficient and the laser fluence) at the medium interface. In the first part of the paper, the influence of the laser beam diameter, the light absorption and reduced scattering coefficients on the maximal amplitude of the laser fluence at the laser beam axis in the near-surface layer of the turbid medium is studied by using the Monte-Carlo simulation. The conditions are predicted under which the amplitude of the OA signal detected in a transparent medium in contact with the scattering medium should remain proportional to the light absorption coefficient of the medium under study, when the scattering coefficient in it changes more than twice. The results of the numerical simulation are used for the theoretical substantiation of the OA method being proposed. (measurement of parametrs of laser radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predicting river turbidity in Pine Island Bayou using machine learning techniques coupled with variational mode decomposition

Elevated turbidity levels pose significant public health risks by facilitating the transport of harmful pollutants, including metals, organic compounds, and pathogenic microorganisms into the surface water. These conditions create serious challenges for public recreational water use and drinking water treatment, leading to economic losses and health risks. This study utilizes water monitoring data in Pine Island Bayou, Texas, and develops a Sequence-to-Sequence (S2S) model to predict turbidity using Attention-based Gated Recurrent Units with Encoder-Decoder (AT-GRU-ED) and Long Short-Term Memory (LSTM), coupled with Variational Mode Decomposition (VMD). Compared to the model without VMD, the model demonstrates satisfactory 72-hour turbidity prediction performance, achieving MAEs of 2.60 and 3.29 NTU (reductions of 53% and 58%), RMSEs of 21.08 and 31.49 NTU (reductions of 82% and 80%), and R² values of 0.96 and 0.84 on the validation and test sets, respectively. Feature importance analysis reveals that water temperature is the dominant factor influencing seasonal turbidity patterns, while real-time hourly rainfall significantly contributes to short-term variability. Turbidity typically peaks within 48 hours after rainfall events due to lagged effects from surface runoff and upstream flow. Findings suggest suspending recreational water use and water supply pumping for three days after heavy rainfall can benefit public health and improve water treatment processes. Discharges above 100 m3/s are found to accelerate sediment dilution and transport, reducing turbidity levels more quickly after the peak. In conclusion, the proposed model demonstrates reliable 72-hour turbidity prediction, supporting decision-making for water treatment plant operations and providing early warning for public recreational water use.

Deep learning↗

Radiometry of water turbidity measurements

An examination of a number of measurements of turbidity reported in the literature reveals considerable variability in the definitions, units, and measurement techniques used. Many of these measurements differ radically in the optical quantity measured. The radiometric basis of each of the most common definitions of turbidity is examined. Several commercially available turbidimeters are described and their principles of operation are evaluated radiometrically. It is recommended that the term turbidity be restricted to measurements based upon the light scattered by the sample with that scattered by standard suspensions of known turbidity. It is also recommended that the measurement procedure be standardized by requiring the use of Formazin as the turbidity standardizing material and that the Formazin Turbidity Unit (FTU) be adopted as the standard unit of turbidity.

Mccluney, W. R.↗

Turbidity study of solar ponds utilizing seawater as salt source

A series of experiments were conducted to study the turbidity reduction in solar ponds utilizing seawater as salt source. The experiment on the turbidity reduction efficiency with chemicals indicates that alum (KAl(SO{sub 4}){sub 2}.12H{sub 2}O) has a better turbidity control property because of its strongly flocculating and also well depressing the growing of algae and bacteria in the seawater. In comparison with bittern and seawater, our experiment shows that the residual brine after desalination can keep limpidity for a long time even without any chemical in it. Experiments were also conducted on the diffusion of turbidity and salinity, which show that the turbidity did not diffuse upwards in the solution. In the experiment on subsidence of soil in the bittern and saline with the same salinity, it was found that soil subsided quite quickly in the pure saline water, but very slowly in the bittern. In this paper we also proposed an economical method to protect the solar pond from the damage of rain. Finally, thermal performance of a solar pond was simulated in the conditions of different turbidities using a thermal diffusion model. (author)

14 SOLAR ENERGY↗

Application of MODIS Products to Infer Possible Relationships Between Basin Land Cover and Coastal Waters Turbidity Using the Magdalena River, Colombia, as a Case Study

Basin development and consequent change in basin land cover have been often associated with an increased turbidity in coastal waters because of sediment yield and nutrients loading. The later leads to phytoplankton abundance further exacerbating water turbidity. This subsequently affects biological and physical processes in coastal estuaries by interfering with sun light penetration to coral reefs and sea grass, and even affecting public health. Therefore, consistent estimation of land cover changes and turbidity trend lines is crucial to design environmental and restoration management plans, to predict fate of possible pollutants, and to estimate sedimentary fluxes into the ocean. Ground solely methods to estimate land cover change would be unpractical and traditional methods of monitoring in situ water turbidity can be very expensive and time consuming. Accurate monitoring on the status and trends of basin land cover as well as the water quality of the receiving water bodies are required for analysis of relationships between the two variables. Use of remote sensing (RS) technology provides a great benefit for both fields of study, facilitating monitoring of changes in a timely and cost effective manner and covering wide areas with long term measurements. In this study, the Magdalena River basin and fixed geographical locations in the estuarine waters of its delta are used as a case to study the temporal trend lines of both, land cover change and the reflectance of the water turbidity using satellite technology. Land cover data from a combined product between sensors Terra and Aqua (MCD12Q1) from MODIS will be adapted to the conditions in the Magdalena basin to estimate changes in land cover since year 2000 to 2009. Surface reflectance data from a MODIS, Terra (MOD09GQ), band 1, will be used in lieu of in situ water turbidity for the time period between 2000 and present. Results will be compared with available existing data.

Madrinan, Max Jacobo Moreno↗

Remote measurement of turbidity and chlorophyll through aerial photography

Studies were conducted utilizing six different film and filter combinations to quantitatively detect chlorophyll and turbidity in six farm ponds. The low range of turbidity from 0-35 JTU correlated well with the density readings from the green band of normal color film and the high range above 35 JTU was found to correlate with density readings in the red band of color infrared film. The effect of many of the significant variables can be reduced by using standardized procedures in taking the photography. Attempts to detect chlorophyll were masked by the turbidity. The ponds which were highly turbid also had high chlorophyll concentrations; whereas, the ponds with low turbidity also had low chlorophyll concentrations. This prevented a direct correlation for this parameter. Several suggested approaches are cited for possible future investigations.

Schwebel, M. D.↗

SeaDAS Tutorial: Applying Color Ramps to ACOLITE Turbidity Products

This tutorial provides step-by-step instructions for applying color ramps and legends to ACOLITE turbidity products derived from the Dogliotti turbidity equation. The user inputs their own image and the resulting product is a colorized visualization of turbidity. This visualization provides the user with a better understanding of turbidity in their image and can be used to support further analysis of turbidity patterns.

Kelly Young↗

Interrelation of surface tension, optical turbidity, and color of operational transformer oils

Measurements of the acidity, optical turbidity, surface tension, and color of transformer oil from 54 power transformers, autotransformers, and shunt reactors are reported. Changes in surface tension, optical turbidity, and color are found to obey adequate linear correlations, while the acidity has no correlation with any of these properties. Numerical criteria for the maximum permissible state (quality) of the oil with respect to optical turbidity and color are obtained. Recommendations to operating staff are provided for cases in which the criteria for optical turbidity and color are exceeded.

42 ENGINEERING↗

Dynamics of turbidity plumes in Lake Ontario

The author has identified the following significant results. Large turbidity features along the 275 km south shore of Lake Ontario were analyzed using LANDSAT-1 images. The Niagara River plume, ranging from 30 to 500 sq km in area is, by far, the largest turbidity feature in the lake. Based on image tonal comparisons, turbidity in the Welland Canal is usually higher than that in any other water course discharging into the lake during the shipping season. Less turbid water enters the lake from the Port Dalhousie diversion channel and the Genesee River. Relatively clear water resulting from the deposition of suspended matter in numerous upstream lakes is discharged by the Niagara and Oswego Rivers. Plume analysis corroborates the presence of a prevailing eastward flowing longshore current along the entire south shore. Plumes resulting from beach erosion were detected in the images. Extensive areas of the south shore are subject to erosion but the most severely affected beaches are situated between Fifty Mile Point, Ontario and Thirty Mile Point, New York along the Rochester embayment, and between Sodus Bay and Nine Mile Point.

Pluhowski, E. J.↗

General pattern of the turbid water in the Seto-inland sea extracted from multispectral imageries by the LANDSAT-1 and 2

The author has identified the following significant results. Each distribution pattern of turbid water changes with the time in accordance with daily tides, seasonal variation of tides, and occasional rainfall. Two cases of successfully repeated LANDSAT observations for the same sea regions suggested a general pattern of turbid water could be extracted for each region. Photographic and digital processes were used to extract patterns of turbid water separately from the cloud and smog-layer in MSS 4, 5, and 7 imageries. A mosaic of image-masked imageries displays a general pattern of turbid water for almost the entire Seto Inland Sea. No such pattern was extracted for the Aki-Nada south of Hiroshima City where the water is fairly polluted, nor for the Iyo-Nada where the water is generally clearer than in other regions of the Seto Inland Sea.

Maruyasu, T.↗

Precision Cleaning Verification of Nonvolatile Residues by Using Water, Ultrasonics, and Turbidity Analyses

Chlorofluorocarbons (CFC's) in the atmosphere are believed to present a major environmental problem because they are able to interact with and deplete the ozone layer. NASA has been mandated to replace chlorinated solvents in precision cleaning, cleanliness verification, and degreasing of aerospace fluid systems hardware and ground support equipment. KSC has a CFC phase-out plan which provides for the elimination of over 90 percent of the CFC and halon use by 1995. The Materials Science Laboratory and KSC is evaluating four analytical methods for the determination of nonvolatile residues removal by water: (1) infrared analyses using an attenuated total reflectance; (2) surface tension analyses, (3) total organic content analyses, and (4) turbidity analyses. This research project examined the ultrasonic-turbidity responses for 22 hydrocarbons in an effect to determine: (1) if ultrasonics in heated water (70 C) will clean hydrocarbons (oils, greases, gels, and fluids) from aerospace hardware; (2) if the cleaning process by ultrasonics will simultaneously emulsify the removed hydrocarbons in the water; and (3) if a turbidimeter can be used successfully as an analytical instrument for quantifying the removal of hydrocarbons. Sixteen of the 22 hydrocarbons tested showed that ultrasonics would remove it at least 90 percent of the contaminated hydrocarbon from the hardware in 10 minutes or less giving a good ultrasonic-turbidity response. Six hydrocarbons had a lower percentage removal, a slower removal rate, and a marginal ultrasonic-turbidity response.

Skinner, S. Ballou↗

Turbidity of a binary fluid mixture: Determining eta

A ground based (1-g) experiment is in progress that will measure the turbidity of a density-matched, binary fluid mixture extremely close to the critical point. By covering the range of reduced temperatures t is equivalent to (T-T(sub c))/T(sub c) from 10(exp -8) to 10(exp -2), the turbidity measurements will allow the critical exponent eta to be determined. No experiment has determined a value of the critical exponent eta, yet its value is significant to theorists in critical phenomena. Interpreting the turbidity correctly is important if future NASA flight experiments use turbidity as an indirect measurement of relative temperature in shuttle experiments on critical phenomena in fluids.

Jacobs, Donald T.↗

MODIS Retrieval of Aerosol Optical Depth over Turbid Coastal Water

We present a new approach to retrieve Aerosol Optical Depth (AOD) using the Moderate Resolution Imaging Spectroradiometer (MODIS) over the turbid coastal water. This approach supplements the operational Dark Target (DT) aerosol retrieval algorithm that currently does not conduct AOD retrieval in shallow waters that have visible sediments or sea-floor (i.e., Class 2 waters). Over the global coastal water regions in cloud-free conditions, coastal screening leads to approx. 20% unavailability of AOD retrievals. Here, we refine the MODIS DT algorithm by considering that water-leaving radiance at 2.1 microns to be negligible regardless of water turbidity, and therefore the 2.1 microns reflectance at the top of the atmosphere is sensitive to both change of fine-mode and coarse-mode AODs. By assuming that the aerosol single scattering properties over coastal turbid water are similar to those over the adjacent open-ocean pixels, the new algorithm can derive AOD over these shallow waters. The test algorithm yields approx. 18% more MODIS-AERONET collocated pairs for six AERONET stations in the coastal water regions. Furthermore, comparison of the new retrieval with these AERONET observations show that the new AOD retrievals have equivalent or better accuracy than those retrieved by the MODIS operational algorithm's over coastal land and non-turbid coastal water product. Combining the new retrievals with the existing MODIS operational retrievals yields an overall improvement of AOD over those coastal water regions. Most importantly, this refinement extends the spatial and temporal coverage of MODIS AOD retrievals over the coastal regions where 60% of human population resides. This expanded coverage is crucial for better understanding of impact of anthropogenic aerosol particles on coastal air quality and climate.

Retrieval↗

Updated MISR Over-Water Research Aerosol Retrieval Algorithm - Part 2: A Multi-Angle Aerosol Retrieval Algorithm for Shallow, Turbid, Oligotrophic, and Eutrophic Waters

Coastal waters serve as transport pathways to the ocean for all agricultural and other runoff from terrestrial sources, and many are the sites for upwelling of nutrient rich, deep water; they are also some of the most biologically productive on Earth. Estimating the impact coastal waters have on the global carbon budget requires relating satellite-based remote-sensing retrievals of biological productivity (e.g., chlorophyll alpha concentration) to in situ measurements taken in near-surface waters. The Multi-angle Imaging SpectroRadiometer (MISR) can uniquely constrain the "atmospheric correction" needed to derive ocean color from remote-sensing imagers. Here, we retrieve aerosol amount and type from MISR over all types of water. The primary limitation is an upper bound on aerosol optical depth (AOD), as the algorithm must be able to distinguish the surface. This updated MISR research aerosol retrieval algorithm (RA) also assumes that light reflection by the underlying ocean surface is Lambertian. The RA computes the ocean surface reflectance (R (sub rs)) analytically for a given AOD, aerosol optical model, and wind speed. We provide retrieval examples over shallow, turbid, and eutrophic waters and introduce a productivity and turbidity index (PTI), calculated from retrieved spectral R (sub rs), that distinguished water types (similar to the the normalized difference vegetation index, NDVI, over land). We also validate the new algorithm by comparing spectral AOD and Angstrom exponent (ANG) results with 2419 collocated AErosol RObotic NETwork (AERONET) observations. For AERONET 558 nanometer-interpolated AOD less than 1.0, the root-mean square error (RMSE) is 0.04 and linear correlation coefficient is 0.95. For the 502 cloud-free MISR and AERONET collocations with an AERONET AOD greater than 0.20, the ANG RMSE is 0.25 and r is 0.89. Although MISR RA AOD retrieval quality does not appear to be substantially impacted by the presence of turbid water, the MISR-RA-retrieved Angstrom exponent seems to suffer from increased uncertainty under such conditions. MISR supplements current ocean color sources in regions where sunglint precludes retrievals from single-view-angle instruments. MISR atmospheric correction should also be more robust than that derived from single-view instruments such as the Moderate Resolution Imaging Spectroradiometer (MODIS). This is especially true in regions of shallow, turbid, and eutrophic waters, locations where biological productivity can be high, and single-view-angle retrieval algorithms struggle to separate atmospheric from oceanic features.

Satellite Remote Sensing↗

Remotely Estimating Total Suspended Solids Concentration in Clear to Extremely Turbid Waters Using a Novel Semi-Analytical Method

Total suspended solids (TSS) concentration is an important biogeochemical parameter for water quality management and sediment-transport studies. In this study, we propose a novel semi-analytical method for estimating TSS in clear to extremely turbid waters from remote-sensing reflectance (Rrs). The proposed method includes three sub-algorithms used sequentially. First, the remotely sensed waters are classified into clear (Type I), moderately turbid (Type II), highly turbid (Type III), and extremely turbid (Type IV) water types by comparing the values of Rrs at 490, 560, 620, and 754 nm. Second, semi-analytical models specific to each water type are used to determine the particulate backscattering coefficients (bbp) at a corresponding single wavelength (i.e., 560 nm for Type I, 665 nm for Type II, 754 nm for Type III, and 865 nm for Type IV). Third, a specific relationship between TSS and bbp at the corresponding wavelength is used in each water type. Unlike other existing approaches, this method is strictly semi-analytical and its sub-algorithms were developed using synthetic datasets only. The performance of the proposed method was compared to that of three other state-of-the-art methods using simulated (N = 1000, TSS ranging from 0.01 to 1100 g/m3) and in situ measured (N = 3421, TSS ranging from 0.09 to 2627 g/m3) pairs of Rrs and TSS. Results showed a significant improvement with a Median Absolute Percentage Error (MAPE) of 16.0% versus 30.2–90.3% for simulated data and 39.7% versus 45.9–58.1% for in situ data, respectively. The new method was subsequently applied to 175 MEdium Resolution Imaging Spectrometer (MERIS) and 498 Ocean and Land Colour Instrument (OLCI) images acquired in the 2003–2020 timeframe to produce long-term TSS time-series for Lake Suwa and Lake Kasumigaura, Japan. Performance assessments using MERIS and OLCI matchups showed good agreements with in situ TSS measurements.

Mulit-Wavelength↗

Observation Technology for Remote Operation in Contaminated Turbid Water - 16113

Remote underwater work in contaminated tanks and pools is one of major decontamination and decommissioning works under high-dose radiation environment. Generally, in this kind of work, visual information obtained by a camera (an optical camera) is limited due to turbid water caused by suspended sludge particles in the water and it makes remote underwater work difficult to be performed safely and efficiently. Therefore, some alternative observation methods to optical cameras have been required. In order to satisfy this requirement, the alternative observation technology which can obtain visual information in contaminated turbid water has been developed since 2014. It is a technology using an acoustic imaging system in a designated airtight container. It provides the visual information in real time regardless of turbidity without significant contamination of any parts of the system. Also, it is able to provide the location information of underwater objects with contactless. This paper will present development details of this innovative observation technology and its effectiveness to various remote works in contaminated turbid water. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗