Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRACHEA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The normal trachea is cleaned by MUC5B mucin bundles from the submucosal glands coated with the MUC5AC mucin

To understand the mucociliary clearance system, mucins were visualized by light, confocal and electron microscopy, and mucus was stained by Alcian blue and tracked by video microscopy on tracheal explants of newborn piglets. We observed long linear mucus bundles that appeared at the submucosal gland openings and were transported cephalically. The mucus bundles were shown by mass spectrometry and immunostaining to have a core made of MUC5B mucin and were coated with MUC5AC mucin produced by surface goblet cells. The transport speed of the bundles was slower than the airway surface liquid flow. We suggest that the goblet cell MUC5AC mucin anchors the mucus bundles and thus controls their transport. Normal clearance of the respiratory tree of pigs and humans, both rich in submucosal glands, is performed by thick and long mucus bundles. - Highlights: • Submucosal glands in the piglet trachea form bundles of MUC5B mucin. • The mucus bundles are coated with MUC5AC mucin produced by surface goblet cells. • The mucus bundles are transported 10-times slower than the airway surface liquid. • The surface goblet cells are suggested to control the mucus bundle movement.

60 APPLIED LIFE SCIENCES↗

Absence of clinical disease and contact transmission of HPAI H5NX clade 2.3.4.4 from North America in experimentally infected pigs

Background In the fall of 2014, highly pathogenic avian influenza (HPAI) subtype H5N8 clade 2.3.4.4 was introduced into North America by migrating waterfowl from Asia where, through reassortment, novel HPAI H5N2 and H5N1 viruses emerged. Objectives Assess the susceptibility of pigs to HPAI H5N1, H5N2, and H5N8 clade 2.3.3.3 from North America. Methods Pigs and trachea explants were inoculated with a representative panel of H5NX clade 2.3.4.4 HPAI viruses from North America. Nasal swabs, BALF, and sera were collected to assess replication and transmission in challenged and direct contact pigs by RRT‐PCR, virus isolation, hemagglutination inhibition, and ELISA. Results Limited virus replication was restricted to the lower respiratory tract of challenged pigs, though absent in the nasal passages and trachea cultures, as determined by RRT‐PCR in all samples. Seroconversion of inoculated pigs was detected by NP ELISA but was not reliably detected by antigen‐specific hemagglutination inhibition. Boost with adjuvanted virus was required for the production of neutralizing antibodies to assess cross‐reactivity between wild‐type avian strains. All RRT‐PCR and serology tests were negative for contact animals indicating a failure of transmission from primary inoculated pigs. Conclusions H5NX clade 2.3.4.4 strains can replicate in the lower respiratory tract of swine upon high titer inoculation, though appear to be incapable of replication in swine nasal epithelium in vivo or ex vivo in trachea explants in culture. Infected pigs did not produce high levels of serum antibodies following infection. Collectively, our data show HPAI H5NX clade 2.3.4.4 viruses to be poorly adapted for replication and transmission in swine.

H5↗

Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams

Purpose: In this report the authors present the validation of a Monte Carlo dose calculation algorithm (XiO EMC from Elekta Software) for electron beams. Methods: Calculated and measured dose distributions were compared for homogeneous water phantoms and for a 3D heterogeneous phantom meant to approximate the geometry of a trachea and spine. Comparisons of measurements and calculated data were performed using 2D and 3D gamma index dose comparison metrics. Results: Measured outputs agree with calculated values within estimated uncertainties for standard and extended SSDs for open applicators, and for cutouts, with the exception of the 17 MeV electron beam at extended SSD for cutout sizes smaller than 5 × 5 cm{sup 2}. Good agreement was obtained between calculated and experimental depth dose curves and dose profiles (minimum number of measurements that pass a 2%/2 mm agreement 2D gamma index criteria for any applicator or energy was 97%). Dose calculations in a heterogeneous phantom agree with radiochromic film measurements (>98% of pixels pass a 3 dimensional 3%/2 mm γ-criteria) provided that the steep dose gradient in the depth direction is considered. Conclusions: Clinically acceptable agreement (at the 2%/2 mm level) between the measurements and calculated data for measurements in water are obtained for this dose calculation algorithm. Radiochromic film is a useful tool to evaluate the accuracy of electron MC treatment planning systems in heterogeneous media.

61 RADIATION PROTECTION AND DOSIMETRY↗

Novel utilization of 3D technology and the hybrid operating theatre: Peri-operative assessment of posterior sterno-clavicular dislocation using cone beam CT

A patient with a medial and posterior dislocation of the right sterno-clavicular (SC) joint and displacement of the trachea and brachiocephalic artery by the medial head of the clavicle underwent general anaesthetic in the operating theatre for an open reduction procedure. The surgeon initially attempted a closed reduction, but this required imaging to check SC alignment. The patient was transferred to an adjacent hybrid operating theatre for imaging. Cone beam computed tomography (CBCT) was performed, which successfully demonstrated a significant reduction in the dislocation of the SC joint. The trachea and brachiocephalic artery were no longer compressed or displaced. This case study demonstrates an alternative to the patient being transferred to the medical imaging department for multi-slice CT. It also describes a novel use of the hybrid operating theatre and its CBCT capabilities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cancer incidence among residents of the Three Mile Island accident area: 1982-1995

Background: The Pennsylvania Department of Health established a registry of the Three Mile Island (TMI) nuclear power plant accident in 1979. Over 93% of the population present on the day of the accident within a 5-mile radius was enrolled and interviewed. We used the registry to investigate the potential cancer risk from low-dose radiation exposure among the TMI population. Methods: Cancer incidence data among the TMI cohort were available from 1982 to 1995. Because more than 97% of the population were white and few cancer cases were reported for those younger than 18 years of age, we included whites of age 18 years and older (10,446 men and 11,048 women) for further analyses. Cox regression models were used to estimate the relative risk (RR) per 0.1 m Sv and 95% confident interval (CI) of cancer by radiation-related exposures. The cancers of interest were all malignant neoplasms, cancer of bronchus, trachea, and lung, cancer of lymphatic and hematopoietic tissues, leukemia, and female breast. Results: Among men and women, there was no evidence of an increased risk for all malignant neoplasms among the TMI cohort exposed to higher maximum and likely {gamma} radiation (RR=1.00, 95% CI=0.97, 1.01 and RR=0.99, 95% CI=0.94, 1.03, respectively) after adjusting for age, gender, education, smoking, and background radiation. Elevation in risk was noted for cancer of the bronchus, trachea, and lung in relation to higher background radiation exposure (RR=1.45, 95% CI=1.02-2.05 at 8.0-8.8 {mu}R/h compared to 5.2-7.2 {mu}R/h). An increased risk of leukemia was found among men exposed to higher maximum and likely {gamma} radiation related to TMI exposure during the ten days following the accident (RR=1.15, 95% CI=1.04, 1.29 and RR=1.36, 95% CI=1.08, 1.71, respectively). This relationship was not found in women. Conclusion: Increased cancer risks from low-level radiation exposure within the TMI cohort were small and mostly statistically non-significant. However, additional follow-up on this population is warranted, especially to explore the increased risk of leukemia found in men.

60 APPLIED LIFE SCIENCES↗

Spine Radiosurgery: A Dosimetric Analysis in 124 Patients Who Received 18 Gy

Purpose: To define the safely tolerated doses to organs at risk (OARs) adjacent to the target volume (TV) of spine radiosurgery (SRS) with 18-Gy in a single fraction. Methods and Materials: A total of 124 patient cases with 165 spine metastases were reviewed. An 18-Gy single-fraction regimen was prescribed to the 90% isodose line encompassing the TV. A constraint of 10 Gy to 10% of the spinal cord outlined 6 mm above and below the TV was used. Dosimetric data to OARs were analyzed. Results: A total of 124 patients (100%) were followed-up, and median follow-up time was 7 months (1-50 months). Symptoms and local control were achieved in 114 patients (92%). Acute Radiation Therapy Oncology Group (RTOG) grade 1 oral mucositis occurred in 11 of 11 (100%) patients at risk for oropharyngeal toxicity after cervical spine treatment. There were no RTOG grade 2-4 acute or late complications. Median TV was 43.2 cc (5.3-175.4 cc) and 90% of the TV received median dose of 19 Gy (17-19.8 Gy). Median (range) of spinal cord maximum dose (Dmax), dose to spinal cord 0.35 cc (Dsc0.35), and cord volume receiving 10 Gy (Vsc10) were 13.8 Gy (5.4-21 Gy), 8.9 Gy (2.6-11.4 Gy) and 0.33 cc (0-1.6 cc), respectively. Other OARs were evaluated when in proximity to the TV. Esophagus (n=58), trachea (n=28), oropharynx (n=11), and kidneys (n=34) received median (range) V10 and V15 of 3.1 cc (0-5.8 cc) and 1.2 cc (0-2.9 cc), 2.8 cc (0-4.9 cc), and 0.8 cc (0-2.1 cc), 3.4 cc (0-6.2 cc) and 1.6 cc (0-3.2 cc), 0.3 cc (0-0.8 cc) and 0.08 cc (0-0.1 cc), respectively. Conclusions: Cord Dmax of 14 Gy and D0.35 of 10 Gy are safe dose constraints for 18-Gy single-fraction SRS. Esophagus V10 of 3 cc and V15 of 1 cc, trachea V10 of 3 cc, and V15 of 1 cc, oropharynx V10 of 3.5 cc and V15 of 1.5 cc, kidney V10 of 0.3 cc, and V15 of 0.1 cc are planning guidelines when these OARs are in proximity to the TV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A single mutation in Taiwanese H6N1 influenza hemagglutinin switches binding to human‐type receptors

Abstract In June 2013, the first case of human infection with an avian H6N1 virus was reported in a Taiwanese woman. Although this was a single non‐fatal case, the virus continues to circulate in Taiwanese poultry. As with any emerging avian virus that infects humans, there is concern that acquisition of human‐type receptor specificity could enable transmission in the human population. Despite mutations in the receptor‐binding pocket of the human H6N1 isolate, it has retained avian‐type (NeuAcα2‐3Gal) receptor specificity. However, we show here that a single nucleotide substitution, resulting in a change from Gly to Asp at position 225 (G225D), completely switches specificity to human‐type (NeuAcα2‐6Gal) receptors. Significantly, G225D H6 loses binding to chicken trachea epithelium and is now able to bind to human tracheal tissue. Structural analysis reveals that Asp225 directly interacts with the penultimate Gal of the human‐type receptor, stabilizing human receptor binding.

de Vries, Robert P.↗

Particle deposition due to turbulent diffusion in the upper respiratory system

Aerosol deposition in the upper respiratory system (trachea to segmental bronchi) is considered and the importance of turbulent diffusion as a deposition mechanism is evaluated. It is demonstrated that for large particles (diameter greater than about 5 microns), turbulent diffusion is the dominant deposition mechanism in the trachea. Conditions under which turbulent diffusion may be important in successive generations of the pulmonary system are determined. The probability of particle deposition is compared with probabilities of deposition, as determined by the equations generally used in regional deposition models. The analysis is theoretical; no new experimental data is presented.

Hamill, P.↗

Metallic Stents for Tracheobronchial Pathology Treatment

Purpose: To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. Patients and Methods: One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. Results: The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 {+-} 1.2 months in patients with malignant lesions and 76.2 {+-} 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Conclusion: Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Image-Guided Cryoablation of Challenging Mediastinal Lesions Using Large-Volume Hydrodissection: Technical Considerations and Outcomes

ObjectiveThis study was designed to describe the technique of percutaneous image-guided cryoablation with large-volume hydrodissection for the treatment of challenging mediastinal lesions.MethodsBetween March 2014 and June 2015, three patients (mean age 62.7 years) with four neoplastic anterior mediastinal lesions underwent five cryoablation procedures using large-volume hydrodissection. Procedures were performed under general anaesthesia using CT guidance. Lesion characteristics, hydrodissection and cryoablation data, technical success, complications, and clinical outcomes were assessed using retrospective chart review.ResultsLesions (mean size 2.7 cm; range 2–4.3 cm) were in contact with great vessels (n = 13), trachea (n = 3), and mediastinal nerves (n = 6). Hydrodissection was performed intercostally (n = 4), suprasternally (n = 2), transsternally (n = 1), or via the sternoclavicular joint (n = 1) using 1–3 spinal needles over 13.4 (range 7–26) minutes; 450 ml of dilute contrast was injected (range 300–600 ml) and increased mean lesion-collateral structure distance from 1.9 to 7.7 mm. Vulnerable mediastinal nerves were identified in four of five procedures. Technical success was 100 %, with one immediate complication (recurrent laryngeal nerve injury). Mean follow-up period was 15 months. One lesion demonstrated residual disease on restaging PET-CT and was retreated to achieve complete ablation. At last follow-up, two patients remained disease-free, and one patient developed distant disease after 1 year without local recurrence.ConclusionsCryoablation using large-volume hydrodissection is a feasible technique, enabling safe and effective treatment of challenging mediastinal lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Self-Expandable, Radioactive Airway Stent Loaded with {sup 125}I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog

PurposeAirway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with {sup 125}I seeds in healthy beagle dog.Materials and MethodsUnder fluoroscopic guidance, forty-eight self-expandable airway stents loaded with {sup 125}I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting.ResultsAll stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of {sup 125}I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope.ConclusionsThis study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with {sup 125}I seeds in healthy beagle dog.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of Radiation Therapy Appears to Improve Outcome in Patients With Malignant Primary Tracheal Tumors: A SEER-Based Analysis

Purpose: To conduct a matched pair analysis assessing the impact of radiotherapy (RT) in patients with resectable and unresectable primary malignant tracheal tumors using Surveillance, Epidemiology and End Results (SEER) database. Patients and Methods: The SEER registry was used to identify every patient (or 'case') who received RT between 1988 and 2007 for primary malignant tracheal tumors, and to search for corresponding 'controls' (not treated with RT), with the same prognostic and treatment factors (surgery on the trachea, disease extension, histology, and gender). Overall survival (OS) was calculated with the Kaplan-Meier methods. Results of OS and cumulative incidence of death from tracheal cancer in the cases and controls, and in various subsets, were compared using log-rank and Gray's tests. Results: Two hundred fifty-eight patients who received RT were identified, and 78 of these had appropriate matched controls identified, forming the basis of this analysis. In the 78 (+RT) cases, the median follow-up was 60 months (range, 10-192) in the survivors vs. 55 months (range, 2-187) in the controls (no-RT group). Patients in RT group had significantly better OS, and a lower cumulative incidence of death from tracheal cancer than no-RT patients (p < 0.05). Treatment with radiation was associated with improved survival in patients with squamous cell histology [p < 0.0001], regional disease extension [p = 0.030], or those that did not undergo resection [p = 0.038]. There were four deaths in RT group and three in no-RT group attributed to cardiac and respiratory causes. Conclusion: Our data suggest a survival benefit for the use of RT broadly for all patients with tracheal cancer. Nevertheless, the retrospective nature of this observational study limits its interpretation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R{sub 50} was reduced by more than 50%. Lung V{sub 20}, V{sub 10}, and V{sub 5} were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor coverage and critical organ sparing. Given the known challenges in central structure dose constraints in stereotactic body radiation therapy to the lung, 4π planning may increase efficacy and reduce toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Ablative Radiation Therapy for Centrally Located Early Stage or Isolated Parenchymal Recurrences of Non-Small Cell Lung Cancer: How to Fly in a “No Fly Zone”

Purpose: We extended our previous experience with stereotactic ablative radiation therapy (SABR; 50 Gy in 4 fractions) for centrally located non-small cell lung cancer (NSCLC); explored the use of 70 Gy in 10 fractions for cases in which dose-volume constraints could not be met with the previous regimen; and suggested modified dose-volume constraints. Methods and Materials: Four-dimensional computed tomography (4DCT)-based volumetric image-guided SABR was used for 100 patients with biopsy-proven, central T1-T2N0M0 (n=81) or isolated parenchymal recurrence of NSCLC (n=19). All disease was staged with positron emission tomography/CT; all tumors were within 2 cm of the bronchial tree, trachea, major vessels, esophagus, heart, pericardium, brachial plexus, or vertebral body. Endpoints were toxicity, overall survival (OS), local and regional control, and distant metastasis. Results: At a median follow-up time of 30.6 months, median OS time was 55.6 months, and the 3-year OS rate was 70.5%. Three-year cumulative actuarial local, regional, and distant control rates were 96.5%, 87.9%, and 77.2%, respectively. The most common toxicities were chest-wall pain (18% grade 1, 13% grade 2) and radiation pneumonitis (11% grade 2 and 1% grade 3). No patient experienced grade 4 or 5 toxicity. Among the 82 patients receiving 50 Gy in 4 fractions, multivariate analyses showed mean total lung dose >6 Gy, V{sub 20} >12%, or ipsilateral lung V{sub 30} >15% to independently predict radiation pneumonitis; and 3 of 9 patients with brachial plexus D{sub max} >35 Gy experienced brachial neuropathy versus none of 73 patients with brachial D{sub max} <35 Gy (P=.001). Other toxicities were analyzed and new dose-volume constraints are proposed. Conclusions: SABR for centrally located lesions produces clinical outcomes similar to those for peripheral lesions when normal tissue constraints are respected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

30 Gy or 34 Gy? Comparing 2 Single-Fraction SBRT Dose Schedules for Stage I Medically Inoperable Non-Small Cell Lung Cancer

Purpose: To review outcomes of 2 single-fraction lung stereotactic body radiation therapy (SBRT) schedules used for medically inoperable early stage lung cancer. Methods and Materials: Patients in our institution have been treated on and off protocols using single-fraction SBRT (30 Gy and 34 Gy, respectively). All patients had node-negative lung cancer measuring ≤5 cm and lying ≥2 cm beyond the trachea-bronchial tree and were treated on a Novalis/BrainLAB system with the ExactTrac positioning system for daily image guidance. Results: For the interval from 2009 to 2012, 80 patients with 82 lesions were treated with single-fraction lung SBRT. Fifty-five patients (69%) and 25 patients (31%) received 30 Gy and 34 Gy, respectively. In a comparison of 30 Gy and 34 Gy cohorts, patient and tumor characteristics were balanced and median follow-up in months was 18.7 and 17.8, respectively. The average heterogeneity-corrected mean doses to the target were 33.75 Gy and 37.94 Gy for the 30-Gy and 34-Gy prescriptions, respectively. Comparing 30-Gy and 34-Gy cohorts, 92.7% and 84.0% of patients, respectively, experienced no toxicity (P was not significant), and had neither grade 3 nor higher toxicities. For the 30-Gy and 34-Gy patients, rates of 1-year local failure, overall survival, and lung cancer-specific mortality were 2.0% versus 13.8%, 75.0% versus 64.0%, and 2. 1% versus 16.0%, respectively (P values for differences were not significant). Conclusions: This is the largest single-fraction lung SBRT series yet reported. and it confirms the safety, efficacy, and minimal toxicity of this schedule for inoperable early stage lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal beam design on intensity-modulated radiation therapy with simultaneous integrated boost in nasopharyngeal cancer

This study aims to determine the optimal beam design among various combinations of field numbers and beam trajectories for intensity-modulated radiation therapy (IMRT) with simultaneous integrated boost (SIB) technique for the treatment of nasopharyngeal cancer (NPC). We used 10 fields with gantry angles of 155°, 130°, 75°, 25°, 0° L, 0° R, 335°, 285°, 230°, and 205° denoted as F10. To decrease doses in the spinal cord, the F10 technique was designed by featuring 2 pairs of split-opposed beam fields at 155° to 335° and 205° to 25°, as well as one pair of manually split beam fields at 0°. The F10 technique was compared with 4 other common field arrangements: F7E, 7 fields with 50° equally spaced gantry angles; F7, the basis of F10 with 155°, 130°, 75°, 0°, 285°, 230°, and 205°; F9E, 9 fields with 40° equally spaced gantry angles; and FP, 7 posterior fields with 180°, 150°, 120°, 90°, 270°, 240°, and 210°. For each individual case of 10 patients, the customized constraints derived after optimization with the standard F10 technique were applied to 4 other field arrangements. The 4 new optimized plans of each individual case were normalized to achieve the same coverage of planning target volume (PTV){sub 63} {sub Gy} as that of the standard F10 technique. The F10 field arrangement exhibited the best coverage in PTV{sub 70} {sub Gy} and the least mean dose in the trachea-esophagus region. Furthermore, the F10 field arrangement demonstrated the highest level of conformity in the low-dose region and the least monitor unit. The F10 field arrangement performed more outstandingly than the other field arrangements in PTV{sub 70} {sub Gy} coverage and spared the central organ. This arrangement also exhibited the highest conformity and delivery efficiency. The F10 technique is recommended as the standard beam geometry for the SIB-IMRT of NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of two arc-based stereotactic body radiotherapy techniques for early-stage lung cancer

To compare the dosimetric and delivery characteristics of two arc-based stereotactic body radiotherapy (SBRT) techniques for early-stage lung cancer treatment. SBRT treatment plans for lung tumors of different sizes and locations were designed using a single-isocenter multisegment dynamic conformal arc technique (SiMs-arc) and a volumetric modulated arc therapy technique (RapidArc) for 5 representative patients treated previously with lung SBRT. The SiMs-arc plans were generated with the isocenter located in the geometric center of patient's axial plane (which allows for collision-free gantry rotation around the patient) and 6 contiguous 60° arc segments spanning from 1° to 359°. 2 RapidArc plans, one using the same arc geometry as the SiMs-arc and the other using typical partial arcs (210°) with the isocenter inside planning target volume (PTV), were generated for each corresponding SiMs-arc plan. All plans were generated using the Varian Eclipse treatment planning system (V10.0) and were normalized with PTV V{sub 100} to 95%. PTV coverage, dose to organs at risk, and total monitor units (MUs) were then compared and analyzed. For PTV coverage, the RapidArc plans generally produced higher PTV D{sub 99} (by 1.0% to 3.3%) and higher minimum dose (by 2.7% to 12.7%), better PTV conformality index (by 1% to 8%), and less volume of 50% dose outside 2 cm from PTV (by 0 to 20.8 cm{sup 3}) than the corresponding SiMs-arc plans. For normal tissues, no significant dose differences were observed for the lungs, trachea, chest wall, and heart; RapidArc using partial arcs produced lowest maximum dose to spinal cord. For dose delivery, the RapidArc plans typically required 50% to 90% more MUs than SiMs-arc plans to deliver the same prescribed dose. The additional intensity modulation afforded by variable gantry speed and dose rate and by overlapping arcs enabled RapidArc plans to produce dosimetrically improved plans for lung SBRT, but required more MUs (by a factor > 1.5) to deliver. The dosimetric improvements, most notably in PTV minimum dose and in dose conformality for irregularly shaped PTVs, may outweigh the increased MUs in using RapidArc. For small and peripherally located tumors, SiMs-arc produces comparable dosimetric quality and could be more efficient in both treatment planning and dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗