Singular Extremals for the Time-Optimal Control of Dissipative Spin (1/2) Particles

We consider the time-optimal control by magnetic fields of a spin (1/2) particle in a dissipative environment. This system is used as an illustrative example to show the role of singular extremals in the control of quantum systems. We analyze a simple case where the control law is explicitly determined. We experimentally implement the optimal control using techniques of nuclear magnetic resonance. To our knowledge, this is the first experimental demonstration of singular extremals in quantum systems with bounded control amplitudes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RECOVERY ACT: DYNAMIC ENERGY CONSUMPTION MANAGEMENT OF ROUTING TELECOM AND DATA CENTERS THROUGH REAL-TIME OPTIMAL CONTROL (RTOC): Final Scientific/Technical Report

This final scientific report documents the Industrial Technology Program (ITP) Stage 2 Concept Development effort on Data Center Energy Reduction and Management Through Real-Time Optimal Control (RTOC). Society is becoming increasingly dependent on information technology systems, driving exponential growth in demand for data center processing and an insatiable appetite for energy. David Raths noted, 'A 50,000-square-foot data center uses approximately 4 megawatts of power, or the equivalent of 57 barrels of oil a day1.' The problem has become so severe that in some cases, users are giving up raw performance for a better balance between performance and energy efficiency. Historically, power systems for data centers were crudely sized to meet maximum demand. Since many servers operate at 60%-90% of maximum power while only utilizing an average of 5% to 15% of their capability, there are huge inefficiencies in the consumption and delivery of power in these data centers. The goal of the 'Recovery Act: Decreasing Data Center Energy Use through Network and Infrastructure Control' is to develop a state of the art approach for autonomously and intelligently reducing and managing data center power through real-time optimal control. Advances in microelectronics and software are enabling the opportunity to realize significant data center power savings through the implementation of autonomous power management control algorithms. The first step to realizing these savings was addressed in this study through the successful creation of a flexible and scalable mathematical model (equation) for data center behavior and the formulation of an acceptable low technical risk market introduction strategy leveraging commercial hardware and software familiar to the data center market. Follow-on Stage 3 Concept Development efforts include predictive modeling and simulation of algorithm performance, prototype demonstrations with representative data center equipment to verify requisite performance and continued commercial partnering agreement formation to ensure uninterrupted development, and deployment of the real-time optimal control algorithm. As a software implementable technique for reducing power consumption, the RTOC has two very desirable traits supporting rapid prototyping and ultimately widespread dissemination. First, very little capital is required for implementation. No major infrastructure modifications are required and there is no need to purchase expensive capital equipment. Second, the RTOC can be rolled out incrementally. Therefore, the effectiveness can be proven without a large scale initial roll out. Through the use of the Impact Projections Model provided by the DOE, monetary savings in excess of $100M in 2020 and billions by 2040 are predicted. In terms of energy savings, the model predicts a primary energy displacement of 260 trillion BTUs (33 trillion kWh), or a 50% reduction in server power consumption. The model also predicts a corresponding reduction of pollutants such as SO2 and NOx in excess of 100,000 metric tonnes assuming the RTOC is fully deployed. While additional development and prototyping is required to validate these predictions, the relative low cost and ease of implementation compared to large capital projects makes it an ideal candidate for further investigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strong stability of linear parabolic time-optimal control problems

Sufficient conditions for strong stability of a class of linear time-optimal control problems with general convex terminal set are derived. Strong stability in turn guarantees qualified optimality conditions. The theory is based on a characterization of weak invariance of the target set under the controlled equation. An appropriate strengthening of the resulting Hamiltonian condition ensures strong stability and yields a priori bounds on the size of multipliers, independent of, e.g. , the initial point or the running cost. In particular, the results are applied to the control of the heat equation into an L 2 -ball around a desired state.

Automation & Control Systems↗

Simultaneous time-optimal control of the inversion of two spin-(1/2) particles

We analyze the simultaneous time-optimal control of two-spin systems. The two noncoupled spins, which differ in the value of their chemical offsets, are controlled by the same magnetic fields. Using an appropriate rotating frame, we restrict the study to the case of opposite shifts. We then show that the optimal solution of the inversion problem in a rotating frame is composed of a pulse sequence of maximum intensity and is similar to the optimal solution for inverting only one spin by using a nonresonant control field in the laboratory frame. An example is implemented experimentally using nuclear magnetic resonance techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real Time Optimal Control of Supercapacitor Operation for Frequency Response

Supercapacitors are gaining wider applications in power systems due to fast dynamic response. Utilizing supercapacitors by means of power electronics interfaces for power compensation is a proven effective technique. For applications such as requency restoration if the cost of supercapacitors maintenance as well as the energy loss on the power electronics interfaces are addressed. It is infeasible to use traditional optimization control methods to mitigate the impacts of frequent cycling. This paper proposes a Front End Controller (FEC) using Generalized Predictive Control featuring real time receding optimization. The optimization constraints are based on cost and thermal management to enhance to the utilization efficiency of supercapacitors. A rigorous mathematical derivation is conducted and test results acquired from Digital Real Time Simulator are provided to demonstrate effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Minimal Time Problem with Impulsive Controls

Time optimal control problems for systems with impulsive controls are investigated. Sufficient conditions for the existence of time optimal controls are given. A dynamical programming principle is derived and Lipschitz continuity of an appropriately defined value functional is established. The value functional satisfies a Hamilton–Jacobi–Bellman equation in the viscosity sense. A numerical example for a rider-swing system is presented and it is shown that the reachable set is enlargered by allowing for impulsive controls, when compared to nonimpulsive controls.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On a Time-Optimal Control Problem Associated with the Heat Exchange Process

The initial-boundary problem for the heat conduction equation inside a bounded domain is considered. It is supposed that on the boundary of this domain the heat exchange according to Newton's law takes place. The control parameter is equal to the magnitude of output of hot or cold air and is defined on a given part of the boundary. An estimate of the minimal time for achieving the given average temperature is found.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient Optimization of Large Wind Farms for Real-Time Control: Preprint

Wind turbines in a wind farm typically operate individually to maximize their own performance regardless of the impact of aerodynamic interactions on neighboring turbines. Properly coordinating turbines, by operating some turbines suboptimally, within a wind farm has the potential to improve overall wind farm performance. Computing the optimal control strategy under varying atmospheric conditions can be computationally intense for large wind farms. As wind power farms increase in size and related models become more complex, computationally efficient algorithms are needed to perform real-time optimization and control. This study proposes a distributed optimization framework and computationally efficient wake steering wind farm control strategy that uses the yaw angle of a turbine to alter the behavior of a turbine wake and minimize turbine interactions. This computational efficiency allows the strategy to be feasible for real-time control.

17 WIND ENERGY↗

Frictionless atom cooling in harmonic traps: A time-optimal approach

In this article we formulate frictionless atom cooling in harmonic traps as a time-optimal control problem, permitting imaginary values of the trap frequency for transient time intervals during which the trap becomes an expulsive parabolic potential. We show that the minimum time solution has a ''bang-bang'' form, where the frequency jumps suddenly at certain instants and then remains constant, and calculate estimates of the minimum cooling time for various numbers of such jumps. A numerical optimization method based on pseudospectral approximations is used to obtain suboptimal realistic solutions without discontinuities, which may be implemented experimentally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FORCE Update 2024

The Framework for Optimization of Resources and Economics (FORCE) tool suite is the U.S. Department of Energy’s Nuclear Integrated Energy Systems (IES) Program flagship tool suite for technoeconomic IES analysis of IES. This tool suite is useful for analysis designed to evaluate and improve the technoeconomics of energy production systems, particularly for systems including nuclear technology. In this report, we document the development activity for the FORCE tool suite to extend its capabilities as performed during fiscal year 2024. In addition to reliability and accessibility, capability is one of the three standards guiding the development of the FORCE tool suite and the software codes that are its constituent parts. Extending the capabilities of the FORCE tool suite allows analysis both within the IES program as well as industry, university, and laboratory partners to perform analysis with more accuracy, insight, and impactful narrative. Four areas of capability development were the focus of activity this year: economic parameter uncertainty quantification, multiresolution analysis, components-to-optimization workflow automation, and statespace construction workflows for real-time optimal control. In economic parameter uncertainty quantification, the ability of HERON to capture risk due to scenarios (weather and energy demand uncertainty) was expanded to also include uncertainties in financial parameters such as capital cost or operation and maintenance costs. By including these sources of uncertainty, which are sometimes very large compared with scenario uncertainty, HERON is better able to capture the risk posed by investment in various IES technology. Because of this, analysts can also consider the reduction in risks that can be realized by choice of some technologies. In multiresolution analysis, development activity extended on work completed previously. In fiscal year 2023, methods for decomposing time series signals, such as demand, solar and wind availability, and price profiles, were analyzed and down-selected to those most effective at splitting signals into different resolutions. These resolutions allow considering the influence of different energy demand and supply behaviors across different time scales. For example, energy demand might be divided into seasonal, weekly, and hourly profiles. In fiscal year 2024, this preliminary work was extended and implemented within the Risk Analysis Virtual Environment (RAVEN) risk and uncertainty analysis platform, which is used throughout the FORCE framework. This development of the “multi-resolution time series analysis” (MR-TSA) module in RAVEN allows training synthetic history generators on complex time series. These synthetic history generators can then be used in HERON for generating scenarios that represent possible market and weather scenarios that can be analyzed on different time scales. We envision completing this work in the future, implementing multiresolution dispatch optimization strategies that can make the most beneficial use of these stratified time histories. In components-to-optimization workflow development, workflows for translating user inputs of components into algorithms for algebraic optimization were selected and implemented. Similar algorithms within the Holistic Energy Resource Optimization Network (HERON) were separated from the main code base of HERON and gathered with the components-to-optimization workflows in the new Dispatch Optimization Variable Engine (DOVE) software library. This modularization allows FORCE users to analyze dispatch optimization and energy system duty cycles independently of HERON, which previously was a burdensome task. Additionally, these dispatch optimization algorithms, set up in an independent library, can now be used across all software applications within FORCE, especially including the real-time optimal control software Optimization of Real-time Capacity Allocation (ORCA). Allowing FORCE software to share dispatch optimization algorithms within a single library allows for improved software maintenance and reliability. In statespace characterization workflow development, alternative workflows for optimizing dispatch with additional technical accuracy was the focus, particularly to improve the real-time optimization decision making in ORCA. Using algorithms and workflows initially developed for the Feasible Actuator Range Modifier (FARM), workflows for determining the statespace representation of IES were identified and demonstrated. The resulting dispatch optimization required a more robust optimization algorithm than that originally used in HERON (and moved to DOVE), which required adding an alternate workflow to DOVE that can more accurately match the behavior of physical systems using a partial differential equation representation. In conclusion, capability developments in the FORCE tool suite in fiscal year 2024 have improved the ability of the FORCE tool suite to perform

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Real-Time On-Ramp Merging Control of Connected and Automated Vehicles using Pseudospectral Convex Optimization

Highway on-ramp merging can be a challenging task for human drivers due to the complex vehicle negotiations and interactions in limited time and space. Connected and automated vehicles (CAVs) have great potential to address the problem and offer many benefits in terms of safety, traffic efficiency, and fuel economy. However, real-time optimal control of CAVs still faces many challenges, including nonlinear dynamics, complex inter-vehicle interactions, and a highly dynamic and uncertain traffic environment. To address these challenges, we develop a novel control approach that balances the solution optimality and computational efficiency to determine optimal merging speed profiles in real time. Specifically, by employing a pseudospectral method and a sequential convex programming approach, two algorithms are proposed and implemented within the model predictive control (MPC) framework to enable real-time generation of optimal solutions for potential on-vehicle applications. The convergence and optimality of the proposed algorithms are validated by comparing with a general-purpose solver under different traffic scenarios.

Shi, Yang↗

Pseudospectral convex optimization for on-ramp merging control of connected vehicles

It can be a daunting task for human drivers to merge into highways because of the intricate vehicle negotiations and potential risk within limited time and space. Connected vehicle (CV) technologies could be a solution to this problem and offer many benefits to the road safety, traffic mobility, and energy efficiency. However, real-time optimal control of CVs is still an open challenge, due to the nonlinear vehicle dynamics, non-convex fuel consumption model, and highly dynamic uncertain inter-vehicle interactions. To tackle these issues, a novel real-time optimal control approach that balances the computational efficiency and solution optimality is proposed for the purpose of onboard application. To this end, the pseudospectral collocation method is integrated with a sequential convex programming approach to develop two new optimization algorithms, which are implemented within a model predictive control (MPC) framework to allow for real-time generation of optimal merging speed profiles. One algorithm leverages the line search technique to improve convergence, and the other benefits from the trust region method for better computational efficiency. The optimality and convergence process of both proposed algorithms are investigated by comparing their solutions with a popular non-linear solver. Furthermore, simulation results show that the proposed methods outperform the benchmark in terms of computational cost, fuel consumption, and traffic efficiency. In particular, the proposed fuel-economy merging rule can save 57.1% fuel consumption on average on four different traffic volumes. Meanwhile, the proposed optimal control algorithms can reduce 2.2% travel time on average comparing to the “first-in-first-out” merging rule.