Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Collar Properties and Measurement Time Confer Minimal Bias Overall on Annual Soil Respiration Estimates in a Global Database

Abstract Measuring the soil‐to‐atmosphere carbon dioxide (CO 2 ) flux (soil respiration, R S ) is important to understanding terrestrial carbon balance and to forecasting climate change. Such measurements are frequently made using measurement collars permanently inserted into the soil surface. However, differences in measurement duration and frequency, as well as collar properties, may lead to biases in the estimation of annual R S . Using a newly updated global R S database (SRDB‐V5), we investigated the annual R S bias associated with five methodological factors: collar height, collar coverage area, collar insertion depth, measurement duration, and measurement frequency. We found that annual R S was negatively correlated with collar insertion depth, consistent with the idea that collar insertion cuts roots and thus reduces R S . Annual R S was also negatively related with collar height and collar coverage area, perhaps because uniform head‐space mixing is difficult to achieve in larger volume chambers; however, these effects were quantitatively small (bias of ~2% to 10% of mean R S ). We found no correlation of measurement duration or measurement frequency with annual R S . These findings suggest that variation in R S methodology generally introduces minimal bias overall. Therefore, compilations of minimally adjusted annual R S measurements provide a reliable resource for synthesis studies, global annual R S modeling, and investigation of how soil carbon responds to climate change.

Jian, Jinshi↗

Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector

Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ∼15% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels with counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector–TCSPC board.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Relaxation-time measurement via a time-dependent helicity balance model

A time-dependent helicity balance model applied to a spheromak helicity-injection experiment enables the measurement of the relaxation time during the sustainment phase of the spheromak. The experiment, the Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI), studies spheromak formation and sustainment through inductive helicity injection. The model captures the dominant plasma behavior seen during helicity injection in HIT-SI by using an empirical helicity-decay rate, a time-dependent helicity-injection rate, and a composite Taylor state to model both the helicity content of the system and to calculate the resulting spheromak current. During single-injector operations, both the amplitude and the phase of the periodic rise and fall of the toroidal current are predicted by this model, with an exchange of helicity between the injector states and the spheromak state proposed as the causal mechanism. This phenomenon allows for the comparison of the delay between the current rises in the experiment and the numerical model, enabling a measurement of the relaxation time. The measured relaxation time of 4.8 {mu}s {+-} 2.8 {mu}s is shorter than the toroidal Alfven timescale. These results validate Hall MHD calculations of the Geospace Environmental Modeling challenge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of spin diffusion on electron spin relaxation time measured with a time-resolved microscopic photoluminescence technique

We performed measurements at room temperature for a GaAs/AlGaAs multiple quantum well grown on GaAs(110) using a time-resolved microscopic photoluminescence (micro-PL) technique to find what effects spin diffusion had on the measured electron spin relaxation time, τ{sub s}, and developed a method of estimating the spin diffusion coefficient, D{sub s}, using the measured data and the coupled drift-diffusion equations for spin polarized electrons. The spatial nonuniformities of τ{sub s} and the initial degree of electron spin polarization caused by the pump intensity distribution inside the focal spot were taken into account to explain the dependence of τ{sub s} on the measured spot size, i.e., a longer τ{sub s} for a smaller spot size. We estimated D{sub s} as ∼100 cm{sup 2}/s, which is similar to a value reported in the literature. We also provided a qualitative understanding on how spin diffusion lengthens τ{sub s} in micro-PL measurements.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Catalog of Temporally Localized Systematic Deviations in Global Body Wave Travel-Time Measurements

Accurate measurements of the arrival times of seismic waves are crucial for seismological analyses such as robust locations of earthquakes, characterization of seismic sources, and high-fidelity imaging of the Earth’s interior. However, these travel-time measurements can sometimes be contaminated by timing errors at the stations which record this data. In this study, we apply a classical approach, based on identifying time-dependence in measured body wave arrival times, to identify these timing errors in a dataset on the order of 107 individual measurements. We find timing deviations at a subset of the stations in our dataset and document the temporal location, extent, and severity of these errors, finding errors at 83 stations, and impacting ~100,000 measurements. This catalog of deviations may enable future investigators to obtain a more accurate dataset through the implementation of quality control measures to eliminate the contaminated data we have identified.

58 GEOSCIENCES↗

Considerations for in situ, real time measurement of plasma-material interactions using Digital Holographic imaging

Digital Holographic (DH) imaging is a laser-based measurement technique, which can be used to monitor a material surface as it is being exposed to fusion-relevant plasmas. Both single-laser and dual-laser DH measurements have been demonstrated ex situ at Oak Ridge National Laboratory (ORNL). A DH diagnostic system is being assessed for deployment at ORNL to make in situ, real-time measurements of plasma erosion/redeposition in the Prototype Material Plasma Exposure eXperiment (Proto-MPEX). In situ, real time measurements pose unique challenges to diagnostic systems, which are not encountered by ex situ analysis techniques. The absolute surface height (tracked at the nm to μm position) during plasma exposure can be modified by: 1) surface movement due to vibration or thrust exerted by the plasma device, 2) surface growth due to the thermal expansion of the material under steady MW/m2 or transient GW/m2 plasma heat loads, and 3) surface modification due to plasma erosion/redeposition of the material substrate. To assess these effects, 1) the vibration spectrum of the diagnostic and the pulsed plasma device have been measured, 2) the thermal growth of the surface has been measured for an applied heat flux, and 3) the surface modification has been measured ex situ post plasma exposure, and ex situ post laser ablation as a proxy for the plasma. This paper will provide an overview of the results that have been achieved in the development of a DH diagnostic for in situ real-time measurements of plasma exposed surfaces in the Proto-MPEX device.

Biewer, Theodore↗

Model-Free Building Temperature Control and Power Allocation Under Measurement Time Delays

Taking a step towards a greener planet has created an increased need for a higher integration of renewable energy resources into the electric grid. Nonetheless, the intermittency and uncertainty associated with renewable generation have slowed down this integration. Demand response (DR) has been recently adopted to address this challenge by utilizing demand side flexibility and enabling the participation of many grid-interactive efficient buildings (GEBs). However, existing DR methods require significant modeling and/or training efforts and are computationally expensive. To address the aforementioned issues, we propose a model-free control (MFC)-based strategy that is robust to the time delays in the temperature measurements of the thermostatically controlled loads (TCLs). It assigns to each GEB a local controller to maintain the TCLs’ temperatures within desired comfort levels, while the load aggregator (LA) allocates the assigned reference power provided by the distribution system operator (DSO) to support a specific grid service, such as demand peak reduction, load shifting, balancing supply and demand, and consuming the solar photovoltaic power locally. We investigate the effects of such loss of information on the local control action as well as on meeting the power allocation constraint. We conclude that, for an appropriate choice of design parameters, the proposed MFC controller is satisfactorily robust to measurement time delays.

Telsang, Bhagyashri↗

Autoignition delay times measurements of linear unsaturated jet fuel compounds inside a shock tube

Autoignition delay times measurements and CO time histories were studied for 2-pentene, a hydrocarbon in aviation fuel and an important species in the development of aviation fuel surrogates. Three mechanisms from the literature were compared against the measured data, and a sensitivity analysis for CO was performed for all mechanisms. Shock tube experiments were performed between 1246 K – 1372 K and 8.8 atm – 9.3 atm at an equivalence ratio of 1, a fuel loading of 0.25% was used and was balanced in oxygen and argon. Discrepancies between the available literature mechanisms exist, the measured data herein is essential for validation of these mechanisms and the reduction of validated mechanisms for coupling into CFD.

09 BIOMASS FUELS↗

A simulation model of front-end electronics for high-precision timing measurements with low-gain avalanche detectors

Here, we report simulation results of a study aiming to optimize parameters of a detector that uses low-gain avalanche detectors (LGAD) for high-precision timing measurements. The detector is assumed to be composed of a 50μm LGAD sensor coupled to front-end readout electronics which is used to measure the time of arrival of minimum ionizing particles. The simulation includes modeling of signal fluctuations in the LGAD sensor, variations of the analog bandwidth and signal-to-noise ratio (SNR) of the front-end electronics, time bin quantization, and radiation damage of the LGAD sensors. Two approaches to measure the timestamp are considered: leading edge and constant fraction. Simulated LGAD pulses before irradiation, and after irradiation with neutron fluences of 5×10 14 n/cm 2 and 1×10 15 n/cm 2 , are studied. The time resolution for a 50μm LGADs was found to be 35 ps for front-end electronics bandwidths larger than 350 MHz and SNRs larger than 30. The time resolution at SNR of 30 for fluences of 5×10 14 n/cm 2 and 1×10 15 n/cm 2 were found to be 31 ps and 37 ps, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

10 ps resolution, 160 ns full scale range and less than 1.5% differential non-linearity time-to-digital converter module for high performance timing measurements

We present a compact high performance time-to-digital converter (TDC) module that provides 10 ps timing resolution, 160 ns dynamic range and a differential non-linearity better than 1.5% LSB{sub rms}. The TDC can be operated either as a general-purpose time-interval measurement device, when receiving external START and STOP pulses, or in photon-timing mode, when employing the on-chip SPAD (single photon avalanche diode) detector for detecting photons and time-tagging them. The instrument precision is 15 ps{sub rms} (i.e., 36 ps{sub FWHM}) and in photon timing mode it is still better than 70 ps{sub FWHM}. The USB link to the remote PC allows the easy setting of measurement parameters, the fast download of acquired data, and their visualization and storing via an user-friendly software interface. The module proves to be the best candidate for a wide variety of applications such as: fluorescence lifetime imaging, time-of-flight ranging measurements, time-resolved positron emission tomography, single-molecule spectroscopy, fluorescence correlation spectroscopy, diffuse optical tomography, optical time-domain reflectometry, quantum optics, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early-time measure in eternal inflation

In a situation like eternal inflation, where our data is replicated at infinitely-many other space-time events, it is necessary to make a prior assumption about our location to extract predictions. The principle of mediocrity entails that we live at asymptotic late times, when the occupational probabilities of vacua has settled to a near-equilibrium distribution. In this paper we further develop the idea that we instead exist during the approach to equilibrium, much earlier than the exponentially-long mixing time. In this case we are most likely to reside in vacua that are easily accessed dynamically. Using first-passage statistics, we prove that vacua that maximize their space-time volume at early times have: 1. maximal ever-hitting probability; 2. minimal mean first-passage time; and 3. minimal decay rate. These requirements are succinctly captured by an early-time measure. The idea that we live at early times is a predictive guiding principle, with many phenomenological implications. First, our vacuum should lie deep in a funneled region, akin to folding energy landscapes of proteins. Second, optimal landscape regions are characterized by relatively short-lived vacua, with lifetime of order the de Sitter Page time. For our vacuum, this lifetime is ~ 10 130 years, which is consistent with the Standard Model estimate due to Higgs metastability. Third, the measure favors vacua with small, positive vacuum energy. This can address the cosmological constant problem, provided there are sufficiently many vacua in the entire ensemble of funnels. As a concrete example, we study the Bousso-Polchinski lattice of flux vacua, and find that the early-time measure favors lattices with the fewest number of flux dimensions. This favors compactifications with a large hierarchy between the lightest modulus and all other Kähler and complex structure moduli.

79 ASTRONOMY AND ASTROPHYSICS↗

In-beam fast-timing measurements in {sup 103,105,107}Cd

Fast-timing measurements were performed in the region of the medium-mass {sup 103,105,107}Cd isotopes, produced in fusion evaporation reactions. Results on new and reevaluated half-lives are analyzed within a systematic study of transition rates. The 7/2{sub 1}{sup +} states in {sup 103,105,107}Cd are interpreted as arising from a single-particle excitation. The 9/2{sup +} states configuration assignment is based on the observed decay branches.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision timing measurements for high energy photons

Particle colliders operating at high luminosities present challenging environments for high energy physics event reconstruction and analysis. We discuss how timing information, with a precision on the order of 10 ps, can aid in the reconstruction of physics events under such conditions. We present calorimeter based timing measurements from test beam experiments in which we explore the ultimate timing precision achievable for high energy photons or electrons of 10 GeV and above. Using a prototype calorimeter consisting of a 1.7×1.7×1.7 cm 3 lutetium–yttrium oxyortho-silicate (LYSO) crystal cube, read out by micro-channel plate photomultipliers, we demonstrate a time resolution of 33.5±2.1 ps for an incoming beam energy of 32 GeV. In a second measurement, using a 2.5×2.5×20 cm 3 LYSO crystal placed perpendicularly to the electron beam, we achieve a time resolution of 59±11 ps using a beam energy of 4 GeV. We also present timing measurements made using a shashlik-style calorimeter cell made of LYSO and tungsten plates, and demonstrate that the apparatus achieves a time resolution of 54±5 ps for an incoming beam energy of 32 GeV.

43 PARTICLE ACCELERATORS↗