Engineering PapersSearch

SEARCH · Engineering Papers

Results for “TEST STAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A High-Voltage High-Current Benchtop Test Stand for Solid-State Switch Testing at the SNS

Solid-state switches already replaced thyratrons in the SNS extraction kicker power supplies, offering improved efficiency and reliability. However, recent supply chain disruptions, combined with a self-firing issue, led us to explore alternative solutions. A vendor-developed MOS-Gated Thyristor switch was introduced but ultimately failed during testing. To investigate the failure and assess possible improvements, a benchtop test stand was constructed to evaluate the performance of a single stage board. This test stand features a Pulse Forming Network (PFN) that operates at 6 kV and 6 kA, with a repetition rate exceeding 60 Hz, simulating real operational conditions. By utilizing this setup, we seek to gain a better understanding of the failure mechanisms, refine the switch designs, and ultimately develop a more reliable alternative for the extraction kicker power supplies.

Bullman, Austin [ORNL]

Operational Experience of a Cryomodule Test Stand for LCLS-II Cryomodules

CMTS1 (cryomodule test stand 1) at Fermilab was built to test cryomodules built for the LCLS-II beamline at SLAC and is currently testing cryomodules for LCLS-II-HE, the high energy upgrade to LCLS-II. The first cryomodule test was in 2016 and to date over 30 cryomodules have been tested here. This talk will highlight operational experience of the vacuum systems including insulating, coupler, and a low particulate beamline vacuum system. It will focus on the problems that have come up over the years, their solutions, and mitigations put in place to prevent further issues.

43 PARTICLE ACCELERATORS

On High-Temperature Dynamometer Test Stand Development

RePED is a novel prototype alternator that has been designed and built to operate at 35 kW under 250 degrees C ambient temperature conditions. The operating efficiency will be measured using a 225-kW motor to drive the machine in a back-to-back configuration. The goal is to determine if the RePED alternator can deliver 35 kW at a rotational speed of 1,000 rpm while operating in 250 degrees C ambient temperature and have a minimum efficiency of 60%. Dynamometer testing of a high-temperature alternator for geothermal drilling presents several unique challenges, especially around maintaining and managing the various sources and types of energy passing through the system without impacting data quality. The objectives of this report are to (1) describe the test stand in detail, the relative orientation of each major component, and the data acquisition system and (2) discuss the behavior of the test stand components such that this report can serve as a reference document for future projects.

15 GEOTHERMAL ENERGY

Developing a GUI for the Robotic Test Stand

The introduction of this poster explains the technology behind DUNE’s far and near detectors and how passing neutrinos generate electrons that drift into a wire grid. I then explain how 3 ASICs manage signals received from electron interception. Next, the poster states how COLDATA chips are undergoing quality control by a Robotic Test Stand using a state machine. I further explained how earlier tests were done via a command line script and the necessity to implement a user-friendly Graphical User Interface with new features a command line can’t implement. For the implementation section, tools and methods for implementation are listed such as Python, tkinter, and GitHub as well as how multithreading and queue implementation was necessary for GUI functionality. Then, I elaborated on the GUIs new features. Finally, I explain how the GUI will be distributed across multiple institutions and future changes planned for the GUI. Photos of the RTS, far detector cave, diagram of anode assembly plane, COLDATA chips, set up tab, result tab, and legacy command line interface are shown.

Gutierrez Villanueva, Jaziel [DuPage Coll.]

Optimizing TinyTPC Test Stand for Low Energy Event Reconstruction

Introducing dopants into liquid argon offers a promising avenue to enhance the sensitivity and performance of LAr detectors such as DUNE. To explore this opportunity, we are optimizing and deploying the TinyTPC test stand, a compact time projection chamber with LArPix readout to study the effects of photosensitive dopants on the charge detected. TinyTPC enables comparative measurements of low-energy responses under various operational configurations and provides a platform to study the behavior of pixel readouts at low energy. We ensured system reliability through continuous current and voltage monitoring, modeling the detector's electrical behavior, and indirectly estimating total resistance under testing conditions. We ran the Blanche cryostat under various thresholds and gain configurations to evaluate their potential impact to low-energy event reconstruction and advancing R&D efforts for dopant integration in neutrino detectors

Van Loenen, Drew [Franciscan U. Steubenville]

TinyTPC - A Test Stand for Photosensitive Dopants

Liquid argon time projection chambers (LArTPCs) are widely used to study accelerator neutrinos. Since LArTPCs are sensitive down to 10– 100 keV, neutrino experiments' physics programs could be extended to lower energies. However, in this scale, LArTPCs' energy resolution is significantly degraded because only charge is collected efficiently. One solution is the introduction of photosensitive dopants, which convert scintillation light to ionization yield. We have built a test stand (TinyTPC) with a LArPix pixelated anode plane and an active mass of 2.1 kg to study these charge enhancements. Our plan is to measure TinyTPC’s energy resolution with and without dopants using radioactive sources. This poster presentation will discuss TinyTPC's status and goals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Integrated Test Stand

Explore the source record for details and available documents.

43 PARTICLE ACCELERATORS

A Graphical User Interface for the Deep Underground Neutrino Experiment Robotic Test Stand

In preparation for DUNE, Fermilab along with six other institutions are testing cold electronics for quality control before components placed in the far detector. We test them by using a robotic arm that places these chips into sockets on a computer board that will test their functionality. Up until now, the chips have been tested using a command line script that drives a state machine to conduct tests step-by-step. In order to lower the skill barrier to conduct tests and to speed up the quality control process, I was tasked to create a graphical user interface that would allow users to use buttons, text boxes, and drop-down menus to input information and tell the testing state machine how to operate. I had to learn about the Python package Tkinter to start the process of widget placement. I further developed a pause feature unused in the previous command line script that would allow the user to shut down testing gracefully, bring the robotic arm to go back to ground state, and go forward or backward a step in the testing process. After completing the basic functionality of the GUI, I started testing production chips with the GUI to debug. Some issues were found, which required me to further develop parts of the inherited state machine code. The code for the GUI has now been pushed into the copy the DUNE/FD_CE git repository and will soon be merged with the official DUNE/FD_CE repository so that the other institutions testing DUNE cold electronics can use and expand upon it.

Gutierrez Villanueva, Jaziel [Fermilab]

The ICEBERG Test Stand for DUNE Cold Electronics Development

ICEBERG is a liquid argon time projection chamber at Fermilab for the purpose of testing detector components and software for the Deep Underground Neutrino Experiment (DUNE). The detector features a 1.15m x 1m anode plane following the specifications of the DUNE horizontal drift far detector and a newly installed X-ARAPUCA photodetector. The status of ICEBERG is reported along with analysis of noise, pulser, and cosmic ray data from the ninth run beginning May 2024 with the goal of advising the DUNE collaboration on the optimal wire readout electronics configuration. In addition, development of an absolute energy scale calibration method is currently underway using known sources such as cosmic ray muon Michel electrons at the ~10 MeV scale and $^{39}$Ar decay electrons at the ~100keV scale. Research into AI-based identification of such events at the data acquisition level is introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

TinyTPC: A TEST STAND FOR LAr DOPING

TinyTPC is a small scale liquid-argon time projection chamber (LArTPC) that studies how photosensitive dopants can improve the energy resolution of low energy events in LArTPCs. Bench tests to resolve high voltage breakdown issues and to improve the low voltage system readout are described. Experimental data with a radioactive source of Th-228 for the calibration of the pixelated readout and the characterization of TinyTPC's energy resolution is explained. Provisional results from the addition of isobutylene (photosensitive dopant) and xenon (wavelength shifter) to liquid-argon (LAr) are also presented. Further steps to improve voltage system and enhance the data collection are discussed.

Rodriguez Thorne, Paloma

TinyTPC: A Test Stand for LAr Doping

TinyTPC is a small scale liquid-argon time projection chamber (LArTPC) featuring a pixelated readout system (LArPix) designed to improve the detection of charged particles. To enhance energy measurements at MeV scales, TinyTPC will study the impact of isobutylene, a photosensitive dopant that converts light to charge, and xenon, a wavelength shifter. This presentation will detail TinyTPC's commissioning, operation, data collection methodologies, noise levels, and upcoming tests involving isobutylene, xenon, and radioactive sources.

43 PARTICLE ACCELERATORS

TinyTPC: A Test Stand for LAr Doping

LArTPCs are widely used in neutrino experiments at the GeV scale. They measure the charge and light produced by interactions between charged particles and argon atoms. While charge is collected efficiently, light is not. TinyTPC is a small scale LArTPC with a pixelated readout for R&D with photosensitive dopants, which convert light into charge. TinyTPC studies the effects of adding photosensitive dopants and xenon to liquid argon to enhance charge signals of events in the MeV scale.

Rodriguez Thorne, Paloma

Monitoring Helium Cryogen Usage with iFix Software at IB1 Test Facility

At the IB1 facility of the Applied Physics and Superconducting Technology Directorate within the Cryogenic Division at Fermilab, Liquid Helium is essential to the testing activities. The test stands require large amounts of Helium to test the thermal and superconducting cavities and magnets. The Liquid Helium that enters the test stand is monitored through a series of valves and controls to determine the start and stop for monitoring time. There are 3 phases of cryogen usage that must be considered for each stand, cooldown, warming and overnight mode. With a new system in place, cold hour tracking will be more objective and precise within each test stand ensuring better calculations for User s fees which are charged to various groups that employ the facility and aid replenishment of Helium and continual operation at IB1.

Trillo, Angelica

Monitoring Helium Cryogen Usage with iFix Software at IB1 Test Facility

At the IB1 facility of the Applied Physics and Superconducting Technology Directorate within the Cryogenic Division at Fermilab, liquid helium is essential to the testing activities. The test stands used require large amounts of Helium to test the thermal and superconducting cavities and magnets. The liquid helium that enters the test stand is monitored through a series of valves and controls to determine the start and stop for monitoring time. There are 3 phases of cryogen usage that must be considered for each stand, cooldown, warming and overnight mode. With a new system in place, cold hour tracking will be more objective and precise within each test stand ensuring better calculations for user s fees that will provide funding for the replenishment of helium and continual operation at IB1.

Trillo, Angelica

Complete the Design, Cost Estimate, Assembly Plan, and Operating Instructions for a Bench-Scale Packed-Bed Tubular Methanol Catalyst Testing System

This report details the design of a test stand that converts carbon dioxide and hydrogen into methanol via a two-step process. The first step is a reverse water-gas shift reaction, carried out at 600°C and 25 bar to reduce carbon dioxide to carbon monoxide, and the second is a synthesis reaction that forms methanol at 260°C and 75 bar. The purpose of the system is to test catalysts for each of these steps. The test stand produces approximately 1.5 gallons of crude methanol (methanol mixed with water) per day, and recycles unreacted syngas for increased efficiency. At peak recycle, the stand is expected to consume 0.29 cylinders per day of carbon dioxide and 1.43 cylinders per day of hydrogen. It is planned to be built next to the Blue Star electrolysis unit in the Energy Systems Laboratory (ESL) and includes future plans of acquiring hydrogen from that stand rather than gas cylinders. At this phase of research, three key documents have been produced, as summarized in Table 1. These documents are primarily intended to describe the system and its operation, demonstrate that selected components are appropriate for the intended application, identify potential hazards, safeguards, and mitigation strategies, and ensure that the system is designed to appropriate standards. The body of the report and its appendices provide a narrative of the work completed in FY25. The parts required to build the test stand will be procured and assembled in FY26. Testing will be conducted in the final quarter.

10 - SYNTHETIC FUELS

US HL-LHC cryo-assemblies at FNAL - testing and lessons learned

The U.S. High-Luminosity LHC Accelerator Upgrade Project (AUP) is fabricating ten cryogenic assemblies for the HL-LHC Q1/Q3 quadrupole optics at CERN, each integrating two Nb_{3}Sn-based magnets. Fermilab has tested three assemblies (LQXFA/B01–03) at its upgraded horizontal test stand under 1.9 K conditions. Overview of the test stand and the cryo-assembly tests is given along with main results. Challenges met and lessons learned are discussed. Successful testing validates the design and integration of U.S.-produced cryo-assemblies, keeping the project on track for timely delivery to CERN.

Stoynev, Stoyan [Fermilab] (ORCID:0000000345637702

Noble Liquid Test Facility at Fermilab

The Noble Liquid Test Facility (NLTF) at Fermilab is a liquid argon detector R\&D facility open to the national and international HEP community. The facility consists of 4 permanent cryostats, ranging from 250L up to 3000L, open space for small open dewar testing, and an optical test stand facility capable of measuring the optical properties of materials and characterizing photon detectors. NLTF’s strongest advantage is its capability to provide ultra-pure LAr in a reliable manner. Its inline filters are capable of filtering all of the three biggest contaminants for standard LAr detectors, O$_2$ and H$_2$O down to $< 1$ppb and N$_2$ $< 1$ppm. This is critical for the users of the test stands as small levels of impurities can dramatically change the efficiency of LArTPCs for the collection of charge and light. The smallest cryostat is mainly used for material testing, a service provided to the international HEP community interested in understanding how the introduction of a specific material might affect the electron lifetime in LAr. The test stands can be equipped with a purity monitor, which allows measuring the electron lifetime in real time, as well as gas sampling and analyzing, and in the near future, local recirculation and filtering. The facility has hosted many successful R\&D projects, which have published their results in well-known journals and talks. A few examples of such projects are: NIR light production in LAr and GAr, the characterization of VUV metalenses, the testing of new filter media capable of filtering N$_2$ from LAr, high voltage studies and direct charge amplification in LAr, and various doping studies.

Blaszczyk, Flor María [Fermilab]