Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TENSILE STRESS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A silicon microwire under a three-dimensional anisotropic tensile stress

Three-dimensional tensile stress, or triaxial tensile stress, is difficult to achieve in a material. We present the investigation of an unusual three-dimensional anisotropic tensile stress field and its influence on the electronic properties of a single crystal silicon microwire. The microwire was created by laser heating an amorphous silicon wire deposited in a 1.7 μm silica glass capillary by high pressure chemical vapor deposition. Tensile strain arises due to the thermal expansion mismatch between silicon and silica. Synchrotron X-ray micro-beam Laue diffraction (μ-Laue) microscopy reveals that the three principal strain components are +0.47% (corresponding to a tensile stress of +0.7 GPa) along the fiber axis and nearly isotropic +0.02% (corresponding to a tensile stress of +0.3 GPa) in the cross-sectional plane. This effect was accompanied with a reduction of 30 meV in the band gap energy of silicon, as predicted by the density-functional theory calculations and in close agreement with energy-dependent photoconductivity measurements. While silicon has been explored under many stress states, this study explores a stress state where all three principal stress components are tensile. Given the technological importance of silicon, the influence of such an unusual stress state on its electronic properties is of fundamental interest.

36 MATERIALS SCIENCE↗

Tensile stress induced depolarization in [001]-poled transverse mode Pb(Zn{sub 1/3}Nb{sub 2/3})O{sub 3} -(6-7)%PbTiO{sub 3} single crystals

This paper investigates the effects of electrically induced and direct tensile stress on the deformation and dielectric properties of Pb(Zn{sub 1/3}Nb{sub 2/3})O{sub 3}-(6-7)%PbTiO{sub 3} single crystals of [110]{sup L}x[001]{sup T} cut by using a unimorph sample and a four-point-bend (FPB) sample, respectively. The results show a dip in tip displacement for the unimorph sample at sufficiently high electric field parallel to the poling field direction and a sudden rise in capacitance for the FPB sample at sufficiently high tensile stress in the [110] crystal direction, respectively. These phenomena are attributed to the tensile stress induced rhombohedral-to-orthorhombic phase transition and associated depolarization events in the crystal. For the said crystal cut, the obtained tensile depoling stress is in the range of 15-20 MPa. The present work furthermore shows that the occurrence of tensile stress-induced depolarization is possible even when the direction of the applied electric field is parallel to the poling field direction, as in the unimorph sample examined.

36 MATERIALS SCIENCE↗

Shutdown-induced tensile stress in monolithic miniplates as a possible cause of plate pillowing at very high burnup

Post-irradiation examination of Reduced Enrichment for Research and Test Reactors (RERTR)-12 miniplates showed that in-reactor pillowing occurred in at least 4 plates, rendering performance of these plates unacceptable. To address in-reactor failures, efforts are underway to define the mechanisms responsible for in-reactor pillowing, and to suggest improvements to the fuel plate design and operational conditions. To achieve these objectives, the mechanical response of monolithic fuel to fission and thermally-induced stresses was modeled using a commercial finite element analysis code. Calculations of stresses and deformations in monolithic miniplates during irradiation and after the shutdown revealed that the tensile stress generated in the fuel increased from 2 MPa to 100 MPa at shutdown. The increase in tensile stress at shutdown possibly explains in-reactor pillowing of several RERTR-12 miniplates irradiated to the peak local burnup of up to 1.11x1022 fissions/cm3 . This paper presents the modeling approach and calculation results, and compares results with post-irradiation examinations and mechanical testing of irradiated fuel. The implications for the safe use of the monolithic fuel in research reactors are discussed, including the influence of fuel burnup and power on the magnitude of the shutdown-induced tensile stress.

rertr↗

Tensile-stressed microelectromechanical apparatus and microelectromechanical relay formed therefrom

A microelectromechanical (MEM) apparatus is disclosed which includes a shuttle suspended above a substrate by two or more sets of tensile-stressed beams which are operatively connected to the shuttle and which can comprise tungsten or a silicon nitride/polysilicon composite structure. Initially, the tensile stress in each set of beams is balanced. However, the tensile stress can be unbalanced by heating one or more of the sets of beams; and this can be used to move the shuttle over a distance of up to several tens of microns. The MEM apparatus can be used to form a MEM relay having relatively high contact and opening forces, and with or without a latching capability.

47 OTHER INSTRUMENTATION↗

Tensile-stress effect on ferroelectric Barkhausen noise

Here, this study examines the effect of tensile stress on the ferroelectric properties of Pb(Zr 0.4 Ti 0.6 )O 3 thin film, with a focus on Barkhausen noise, observed for the first time under such conditions. Tensile stress significantly alters domain wall motions, affecting Barkhausen noise more than average polarization. Frequency analysis identifies grain boundaries as primary pinning sites, consistent across stress levels. A nonlinear relationship between stress, domain wall mobility, and polarization is found, where increased stress initially enhances pinning and polarization changes, but this effect diminishes at higher stress levels, indicating a shift in behavior.

36 MATERIALS SCIENCE↗

Improved experimental and diagnostic techniques for dynamic tensile stress–strain measurement with a Kolsky tension bar

Kolsky tension bar experiments were improved for dynamic tensile stress–strain measurements with higher fidelity and minimal uncertainties. The difficulties associated with specimen gripping, relatively short gage section, and geometric discontinuity at the bar ends all compromise the accuracy of the traditional strain measurement method in a Kolsky tension bar experiment. Here in this study, an improved three-channel splitting-beam laser extensometer technique was developed to directly and independently track the displacement of the incident and transmission bar interfaces. By adopting a dual-channel configuration on the incident bar side, the resolution and measurement range of this laser extensometer were coordinated between the two channels to provide highly precise measurement at both small and large strains under high strain-rate loading condition. On the transmission bar side an amplified channel, similar to that used on the incident bar side, was adopted to measure the transmission bar displacement with high resolution. With this novel design, a maximum resolution of approximately 500 nm can be obtained for the bar displacement measurement, which corresponds to a strain of 0.0079% for a specimen with 6.35 mm gage length. To further improve the accuracy, a pair of lock nuts were used to tighten the tensile specimen to the bars in an effort not only to prevent the specimen from potential pre-torsional deformation and damage during installation, but also to provide better thread engagement between the specimen and the bar ends. As a demonstration of this technique, dynamic tensile stress–strain response of a 304L stainless steel was characterized with high resolution in both elastic and plastic deformations.

42 ENGINEERING↗

Residual tensile stress in robust insulating rhombohedral Bi{sub 1−x}La{sub x}Fe{sub 1−y}Ti{sub y}O{sub 3} multiferroic ceramics and its ability to pin ferroelectric polarization switching

Robust insulating rhombohedral Bi{sub 1−x}La{sub x}Fe{sub 1−y}Ti{sub y}O{sub 3} multiferroic ceramics with 0.02 ≤ x ≤ 0.12 and 0.01 ≤ y ≤ 0.08 are prepared by a refined solid-state reaction electroceramic processing. Residual internal tensile stresses existed in the ceramics according to unit cell volume enlargement observed by X-ray diffraction and frequency redshifts of Raman modes related to Bi motion and oxygen octahedral rotation detected by Raman scattering measurements. Residual internal tensile stresses in the ceramics are believed to originate from structural phase transitions through an intermediate paraelectric rhombohedral phase with a negative thermal expansion coefficient in the transformation from paraelectric cubic to ferroelectric rhombohedral phases. All of the rhombohedral Bi{sub 1−x}La{sub x}Fe{sub 1−y}Ti{sub y}O{sub 3} ceramics exhibited a pinched polarization versus electric field hysteresis loop indicative of ferroelectric subswitching. We argue that the residual internal tensile stresses are responsible for such ferroelectric polarization subswitching behavior in the Bi{sub 1−x}La{sub x}Fe{sub 1−y}Ti{sub y}O{sub 3} ceramics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of Tensile Stress in DNA Nanoresonators for Epigenetic Studies

The evaluation of epigenetic features such as DNA methylation is becoming increasingly important in many biochemical processes like gene expression and transcription as well as in several diseases like schizophrenia or diabetes. Here, in this work, we report that self-assembled nanomechanical resonators entirely composed of DNA molecules can be used to explore gross changes in DNA methylation levels (0–25–50%), while careful control of tensile stress is needed to reduce the variability of resonance frequency for rigorous quantification. The effect of the tensile stress retained by the suspended DNA nanoresonators on the application of the technique is extensively explored using a combination of laser Doppler vibrometry and atomic force spectroscopy. DNA nanoresonators are real-time, label-free sensors and could avoid chemical functionalization and sample amplification. Therefore, they may represent in the future a key complementary routine tool for global DNA methylation analysis needed to evaluate the consequences of environmental stresses on the human genome.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tensile stress effect on epitaxial BiFeO 3 thin film grown on KTaO 3

Comprehensive crystal structural study is performed for BiFeO 3 (BFO) film grown on KTaO 3 (KTO) substrate using transmission electron microscopy (TEM) and x-ray diffraction (XRD). Nano beam electron diffraction (NBED) combined with structure factor calculation and high resolution TEM images clearly reveal that the crystal structure within BFO thin film is rhombohedral BFO, i.e., bulk BFO phase. Epitaxial relationship found by NBED indicates the BFO film grows in a manner that minimizes lattice mismatch with KTO. It further suggests BFO film is under slight biaxial tensile stress (~0.35%) along in-plane direction. XRD reveals BFO lattice is under compressive stress (~1.6%), along out-of-plane direction as a result of the biaxial tensile stress applied along in-plane direction. This leads to Poisson’s ratio of ~0.68. In addition, we demonstrate (1) why hexagonal notation rather than pseudocubic one is required for accurate BFO phase evaluation and (2) a new XRD method that shows how rhombohedral BFO can readily be identified among other phases by measuring a rhombohedral specific Bragg’s peak.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Relating Hydro–Mechanical and Elastodynamic Properties of Dynamically Stressed Tensile–Fractured Rock in Relation to Applied Normal Stress, Fracture Aperture, and Contact Area

We exploit nonlinear elastodynamic properties of fractured rock to probe the micro-scale mechanics of fractures and understand the relation between fluid transport and fracture aperture under dynamic stressing. Experiments were conducted on rough, tensile-fractured Westerly granite subject to triaxial stresses. We measure fracture permeability for steady-state fluid flow with deionized water. Pore pressure oscillations are applied at amplitudes ranging from 0.2 to 1 MPa at 1 Hz frequency. During dynamic stressing we transmit ultrasonic signals through the fracture using an array of piezoelectric transducers (PZTs) to monitor evolution of interface properties. We examine the influence of fracture aperture and contact area by conducting measurements at effective normal stresses of 10–20 MPa. Additionally, the evolution of contact area with stress is characterized using pressure sensitive film. These experiments are conducted separately with the same fracture and map contact area at stresses from 9 to 21 MPa. The measurements are a proxy for “true” contact area for the fracture surface and we relate them to elastic properties using the calculated PZT sensor footprints via numerical modeling of Fresnel zones. We compare the elastodynamic response of the fracture using the stress-induced changes in ultrasonic wave velocities for transmitter-receiver pairs to image spatial variations in contact properties. We show that nonlinear elasticity and permeability enhancement decrease with increasing normal stress. Additionally, post-oscillation wave velocity and permeability exhibit quick recoveries toward pre-oscillation values. Estimates of fracture contact area (global and local) demonstrate that the elastodynamic and permeability responses are dominated by fracture topology.

58 GEOSCIENCES↗

Anisotropy of tensile stresses and cracking in nonbasal plane Al{sub x}Ga{sub 1-x}N/GaN heterostructures

Al{sub x}Ga{sub 1-x}N films grown on nonpolar m (1100) and (1122) semipolar orientations of freestanding GaN substrates were investigated over a range of stress states (x<=0.17). Cracking on the (0001) plane was observed beyond a critical thickness in the (1100) oriented films, while no cracking was observed for (1122) films. Theoretical analysis of tensile stresses in Al{sub x}Ga{sub 1-x}N for the relevant planes revealed that anisotropy of in-plane biaxial stress for the nonpolar (1100) planes results in the highest normal stresses on the c-planes, consistent with experimental observations. Shear stresses are significant in the semipolar case, suggesting that misfit dislocation formation provides an alternative mechanism for stress relief.

36 MATERIALS SCIENCE↗

Identification of Post-necking Tensile Stress–Strain Behavior of Steel Sheet: An Experimental Investigation Using Digital Image Correlation Technique

The stress–strain behavior of sheet metal is commonly evaluated by tensile test. However, the true stress–strain curve is restricted up to uniform elongation of the material. Usually, after the uniform elongation of the material the true stress–strain is obtained by extrapolation. The present work demonstrates a procedure to find out the true tensile stress–strain curve of the steel sheet after necking using digital image correlation (DIC) technique. Hill’s normal anisotropic yield criteria and local strains measured by DIC technique are used to correct the local stress and strain states at the diffuse necked area. The proposed procedure is shown to successfully determine the true tensile stress–strain curve of ferritic and dual-phase steel sheets after necking/uniform elongation.

36 MATERIALS SCIENCE↗

Effect of tensile stress on the in-plane resistivity anisotropy in BaFe[subscript 2]As[subscript 2]

The effect of uniaxial tensile stress and the resultant strain on the structural/magnetic transition in the parent compound of the iron arsenide superconductor BaFe{sub 2}As{sub 2} is characterized by temperature-dependent electrical resistivity, x-ray diffraction, and quantitative polarized light imaging. We show that strain induces a measurable uniaxial structural distortion above the first-order magnetic transition and significantly smears the structural transition. This response is different from that found in another parent compound, SrFe{sub 2}As{sub 2}, where the coupled structural and magnetic transitions are strongly first order. This difference in the structural responses explains the in-plane resistivity anisotropy above the transition in BaFe{sub 2}As{sub 2}. This conclusion is supported by the Ginzburg-Landau-type phenomenological model for the effect of the uniaxial strain on the resistivity anisotropy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of mechanical loads in inducing in-cycle tensile stress in thermally grown oxide

Experimental in situ synchrotron x-ray diffraction results tracking the strain behavior of the various layers during a cycle, under thermo-mechanical conditions are presented in this work. The quantitative strain measurements here show that the thermally grown oxide briefly experiences in-plane tensile stress ({sigma}{sub 22} = +36.4 MPa) with increased mechanical loading during ramp-up in the thermal cycle. These findings are the first in situ experimental observations of these strains under thermo-mechanical conditions, envisaged to serve as a catalyst for crack initiation. The depth resolved measurements of strain taken during applied thermal and mechanical load in this work are a significant step towards achieving realistic testing conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FEM Modeling of In-Plane Stress Distribution in Thick Brittle Coatings/Films on Ductile Substrates Subjected to Tensile Stress to Determine Interfacial Strength

The ceramic-metal interface is present in various material structures and devices that are vulnerable to failures, like cracking, which are typically due to their incompatible properties, e.g., thermal expansion mismatch. In failure of these multilayer systems, interfacial shear strength is a good measure of the robustness of interfaces, especially for planar films. There is a widely-used shear lag model and method by Agrawal and Raj to analyse and measure the interfacial shear strength of thin brittle film on ductile substrates. The use of this classical model for a type of polymer derived ceramic coatings (thickness ~18 μm) on steel substrate leads to high values of interfacial shear strength. Here, we present finite element simulations for such a coating system when it is subjected to in-plane tension. Results show that the in-plane stresses in the coating are non-uniform, i.e., varying across the thickness of the film. Therefore, they do not meet one of the basic assumptions of the classical model: uniform in-plane stress. Furthermore, effects of three significant parameters, film thickness, crack spacing, and Young’s modulus, on the in-plane stress distribution have also been investigated. ‘Thickness-averaged In-plane Stress’ (TIS), a new failure criterion, is proposed for estimating the interfacial shear strength, which leads to a more realistic estimation of the tensile strength and interfacial shear strength of thick brittle films/coatings on ductile substrates.

36 MATERIALS SCIENCE↗

Capillary flow in UHPFRC with synthetic fibers, under high tensile stresses

A novel Ultra High-Performance Fiber Reinforced Concrete (UHPFRC) mix with synthetic fibers and a low clinker matrix, henceforth referred to as PE-UHPFRC, has been developed for structural applications. It exhibits a high tensile elastic limit above 7 MPa, a tensile strength of more than 10 MPa, and a very high tensile hardening domain of above 3.5%. In order to effectively use this material, its protective properties have been investigated on the basis of the effect of tensile deformation and subsequent cracking on water transport properties, for a wide range of tensile strain. A special setup was developed to measure the capillary absorption of liquids while the specimen is under tension. The results show a considerable reduction in capillary absorption in case of PE-UHPFRC compared with Strain Hardening Cement-based Composites (SHCC). Moreover, the results highlight the considerable effect of the onset of cracking on capillary absorption.

36 MATERIALS SCIENCE↗