Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ultrasonic Measurements of Temperature Distribution and Heat Fluxes Across Containments of Extreme Environments

Extreme conditions are common in energy conversion, material processing, nuclear, airspace, and military applications. In such environments, the most hardened insertion sensors do not perform reliably for long. Ultrasonic measurements, on the other hand, can be acquired noninvasively, with sensitive components kept away from the damaging environment. We have previously developed the ultrasonic method for measuring the spatial distribution of temperatures in solid materials applicable in the cases when large thermal gradients are present. In the developed approach, we use the echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features, to produce a train of echoes in response to an external pulse of ultrasonic excitation. The delays between the echoes, which encode the information on the temperature distribution in the corresponding segments, is used to reconstruct unknown temperature profile. In this paper, we outline the results of pilot-scale testing of the developed approach and demonstrate its application to the measurements of the temperature distribution across the containment of a high-temperature combustion process. The validation results show that the estimated temperature profile is correctly captured, and the measurement accuracy can be comparable with traditional insertion sensors, such as thermocouples. Overall, the testing has confirmed that the developed approach has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term temperature measurements in extreme environments. Heat fluxes and thermal stresses in the structure can then be characterized noninvasively using the measured temperature distribution as the basis.

Jia, Yunlu↗

SECARB Distributed Temperature Sensing Data

Distributed Temperature Sensing data files collected during the SECARB project from Detailed Area of Study wells (CFU F-1, F-2, F-3) at Cranfield oil site in Mississippi. Associated Publications: Nuñez-López, V., Muñoz-Torres, J., and Zeidouni, M., 2014, Temperature monitoring using distributed temperature sensing (DTS) technology: Energy Procedia, v. 63, p. 3984–3991, doi:10.1016/j.egypro.2014.11.428.

CCS↗

Use of Electrical Imaging and Distributed Temperature Sensing Methods to Characterize Surface Water-Groundwater Exchange Regulating Uranium Transport at the Hanford 300 Area, Washington

A critical challenge in advancing prediction of solute transport between contaminated aquifers and rivers is improving understanding of how fluctuations in river stage, combined with subsurface heterogeneity, impart spatiotemporal complexity to solute exchange along river corridors. Here, we explored the use of waterborne geoelectrical imaging, in conjunction with fiber-optic distributed temperature sensor (DTS) monitoring, to improve the conceptual model for uranium transport within the hyporheic corridor at the Hanford 300 Area. We first inverted waterborne geoelectrical (resistivity and induced polarization) datasets for distributions of electrical resistivity and polarizability, from which the spatial complexity of the primary hydrogeologic units was reconstructed. Variations in the depth to the interface between the overlying coarse-grained, high permeability Hanford formation and the underlying finer-grained, less permeable Ringold formation, an important contact that limits vertical migration of contaminants, were resolved along ~3 km of the river corridor centered on the 300 Area. Polarizability images were translated into lithologic images using established relationships between polarizability and surface area normalized to pore volume (Spor). The spatial variability captured in the geoelectrical datasets indicates that previous studies based on borehole projections and point probing overestimate the contributing area for uranium exchange within the Columbia River at the Hanford 300 Area. The DTS data recorded on 1. 5 km of cable with a 1 m spatial resolution and 5 minute sampling interval revealed sub-reaches showing (1) high temperature anomalies and, (2) a strong negative correlation between temperature and river stage, both indicative of groundwater influxes during winter months. The DTS datasets confirm the hydrologic significance of the variability identified in the geoelectrical imaging and reveal a pattern of highly focused hyporheic exchange, with exchange concentrated at springs where the Hanford formation is thick, and coinciding with a paleochannel identified in ground penetrating radar surveys at one location. No evidence for focused hyporheic exchange is observed in the DTS data where the Ringold unit is in contact with the riverbed. Our findings illustrate how the combination of waterborne geoelectrical imaging and DTS technologies can characterize hyporheic exchange in a complex, coupled river-aquifer system.

300 area↗

Power Plant Testing of Ultrasonic Measurements of Temperature Distributions and Heat Fluxes to Heat Exchange Surfaces

Extreme environmental conditions are common in energy conversion applications, in which the most hardened insertion sensors often do not perform reliably for long. On the other hand, ultrasonic measurements can be acquired noninvasively, with sensitive components kept away from the damaging environment. We have previously developed the ultrasonic method for measuring the spatial distribution of temperatures in solid materials applicable when large thermal gradients are present. In the developed approach, we use the echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features, to produce a train of echoes in response to an external pulse of ultrasonic excitation. This paper outlines the testing results of this approach applied to the temperature distribution measurements to a waterwall of a 500 MW power-plant utility boiler. The validation results obtained over the prolonged power plant test show that the estimated temperature profile is correctly captured, and the measurement accuracy can be comparable with traditional insertion sensors, such as thermocouples. Overall, the testing has confirmed that the developed approach has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term temperature measurements in extreme environments. Heat fluxes and thermal stresses in the structure can then be characterized noninvasively using the measured temperature distribution as the basis.

Walton, Kenneth↗

Completion Effects on Diagnosing Multistage Facture Treatments with Distributed Temperature Sensing

Summary Distributed temperature sensing (DTS) is a valuable tool to diagnose multistage hydraulic fracture treatments. When a stage interval is shut in, the clusters that take more fluid during pumping warm up more slowly. Therefore, the fluid volume injected into each cluster can be quantitatively interpreted by numerical inversion of the warm-back temperature behavior. This general concept assumes that the different warm-back behavior is controlled by only the injected fluid volume; however, recent observations of DTS data indicate that completion configurations significantly influence the warm-back behavior. This paper investigates the completion effects on the DTS interpretation. In ideal conditions, when a stage is fractured, the upstream stage intervals should show an almost uniform temperature that is close to the injected fluid temperature. This is due to the high fluid velocity of injected fluid in the wellbore, and the upstream intervals have not been perforated (noncommunicating intervals), so the only heat transfer is heat conduction between the wellbore fluid and the surrounding reservoir. But the field DTS data show considerably irregular variations in temperature along the upstream stage intervals. These variations are caused by the completion effects. The nonuniform temperature profile is caused by different heat transfer behavior induced by completion hardware along the production casing string, such as joints, clamps, and blast protectors, and by the sensing cable location in the cement, as well as the cement quality. Because the varying heat transfer behavior impacts the warm-back behavior as well as the temperature profile, the completion effects need to be considered in DTS interpretation. A method of DTS interpretation considering the completion effects to diagnose multistage fracture treatments was developed. Because the heat transfer between a wellbore and a reservoir depends on the overall heat transfer coefficient describing heat conduction through the completion in a forward model, this parameter needs to be tuned all along the wellbore. To calibrate the completion effect, the temperature inversion is conducted using the temperature measured at a stage interval that is upstream of a stage interval currently being treated. Because the interpreted stage interval is not perforated at that time, the thermal behavior at the noncommunicating interval is governed by only the heat conduction through the completion environment. Once the effective values of the overall heat transfer coefficient are estimated along the interpreted stage interval, they can be assumed to be constant physical parameters. Then, the fluid volume distribution is interpreted by using the effective overall heat transfer coefficient profile along each interval. This study provides a field application of the developed interpretation method. The new interpretation method provides more accurate diagnosis of fracture treatments by DTS interpretation.

Engineering↗

Large Language Model for Validation, Optical Calibration, and Learning (VOCAL) Distributed Temperature Sensing Interface

Distributed temperature sensing (DTS) using fiber optic sensors (FOS) offers a promising method for temperature measurements in advanced reactors, such as sodium fast reactors and molten salt cooled reactors. To support the calibration and validation of DTS measurements, Argonne National Laboratory developed the Validation, Optical Calibration, and Learning (VOCAL) software package. This report describes the integration of a local large language model (LLM) with a retrieval-augmented generation (RAG) system into the VOCAL interface to serve as an interactive user assistant. The LLM framework enhances the VOCAL platform’s accessibility to users by explaining interface components, clarifying inputs and outputs, and answering user queries dynamically in real-time. The accuracy of the LLM assistant performance was evaluated with 20 queries regarding the interface and its parameters using experimental data from the Thermal Hydraulic Experimental Test Article (THETA) facility. Results demonstrate that the LLM achieved a 95% accuracy rate, with a BERTScore of 0.8816 and SBERT value of 0.7417. Furthermore, validation of the RAG system within the LLM framework showed optimal accuracy with k-values between 1 and 2 using the k-refinement convergence test. The prompt perturbation analysis demonstrated good initial consistency for the RAG system, exhibiting the highest accuracy under punctuation variations and the greatest sensitivity under query reordering. Notably, the model’s errors were limited to data retrieval failures rather than factual hallucinations, reinforcing its baseline reliability. The integration of LLM provides a highly accurate, userfriendly enhancement to the VOCAL platform without disrupting its core computational capabilities for FOS calibration and validation.

Hong, Evan↗

Simulation of effects of direction and air flow speed on temperature distribution in the room covered by various roof materials

The objective of this research is to get a comparison of the distribution of the room temperature by using three materials, namely plastic-rubber composite, clay, and asbestos. The simulation used Ansys Fluent to get the temperature distribution. There were two conditions in this simulations, first the air passing beside the room and second the air passing in front of the room. Each condition will be varied with the air speed of 1 m/s, 2 m/s, 3 m/s, 4 m/s, 5 m/s for each material used. There are three heat transfers in this simulation, namely radiation, convection, and conduction. Based on the ANSI/ ASHRAE Standard 55-2004, the results of the simulation showed that the best temperature distribution was the roof of plastic-rubber composites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CHARACTERIZATION OF INTRACLUSTER MEDIUM TEMPERATURE DISTRIBUTIONS OF 62 GALAXY CLUSTERS WITH XMM-NEWTON

We measure the intracluster medium (ICM) temperature distributions for 62 galaxy clusters in the HIFLUGCS, an X-ray flux-limited sample, with available X-ray data from XMM-Newton. We search for correlations between the width of the temperature distributions and other cluster properties, including median cluster temperature, luminosity, size, presence of a cool core, active galactic nucleus (AGN) activity, and dynamical state. We use a Markov Chain Monte Carlo analysis, which models the ICM as a collection of X-ray emitting smoothed particles of plasma. Each smoothed particle is given its own set of parameters, including temperature, spatial position, redshift, size, and emission measure. This allows us to measure the width of the temperature distribution, median temperature, and total emission measure of each cluster. We find that none of the clusters have a temperature width consistent with isothermality. Counterintuitively, we also find that the temperature distribution widths of disturbed, non-cool-core, and AGN-free clusters tend to be wider than in other clusters. A linear fit to {sigma} {sub kT}-kT {sub med} finds {sigma} {sub kT} {approx} 0.20kT {sub med} + 1.08, with an estimated intrinsic scatter of {approx}0.55 keV, demonstrating a large range in ICM thermal histories.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal regimes and limiting pump intensities of a disk laser with the one-dimensional temperature distribution inside the disk

Analytic expressions are derived for one-dimensional distributions of temperature and thermoelastic stresses in an active element (AE) upon stationary multipass pumping equal to or exceeding the threshold. Three events caused by the AE heating are considered, each of the events damaging the laser: a decrease in the efficiency due to the change in the spectral and luminescent properties of the active media, violation of the normal regime of the AE cooling, and destruction of the AE due to the increase in the thermo-mechanical stresses. The domains of the parameters (such as the AE absorption coefficient, the AE thickness, etc.) are determined at which one of the above events first occurs as the pump intensity and correspondingly the AE temperature are increased. Expressions for estimating the limiting pump intensities for each set of the parameters are obtained. (active media)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Continuous snow depth and temperature measurements from dense network of above-ground distributed temperature profiling systems from 2021-09-23 to 2024-08-23, Seward Peninsula, Alaska

The dataset contains temperature measurements from distributed temperature profiling (DTP) systems (Dafflon et al., 2022; Wielandt et al., 2022; Wang et al., 2024a; Fiolleau et al., 2024) deployed vertically above the ground surface at a large number of locations from 2021 to 2024. The research is designed to improve understanding of the local heterogeneity in snow depth and snow thermal insulation dynamics, as well as their interactions in a discontinuous permafrost region (Wang et al., 2025). The DTP systems were deployed at 96 locations in a watershed along the Nome-Teller road at mile marker 27 (T27) and at 54 locations on a hillslope along the Kougarok road at mile marker 64 (K64) in the Seward Peninsula, Alaska. The probe location information is stored in Probe_locations_T27.csv and Probe_locations_K64.csv. Temperature measurements were recorded at 15-minute intervals using high-precision digital sensors (accuracy: ±0.1°C, resolution: 0.0078°C). The temperature probes, either 1.4 m or 1.6 m long, contain sensors spaced every 5 cm or 10 cm along their length. The temperature data are stored in compressed files following the format: DTP_snow_air_temperature_(site)_(start)_(end).zip, where site is either T27 or K64, and start and end represent the time series period. Within each ZIP file, individual CSV files are named by probe ID and contain temperature records at different heights above the ground surface.This dataset also includes derived snow depth time series over three snow seasons, estimated from temperature measurements. Snow depth was estimated by identifying the consecutive sensor pair that exhibited the largest drop in high-frequency temperature fluctuations (detailed in the methods). These data are stored in: Snow_depths_flags_(site)_(start)_(end).csv, which includes snow depth time series and corresponding quality flags (defined in the methods) from different probes. Additionally, the dataset includes derived metrics and supporting measurements at selected locations over two snow seasons, contributing to the manuscript of Wang et al., 2025. These locations were chosen based on the availability of high-quality snow depth time series during both seasons. The additional data include: (1) Air temperature proxies measured from the top sensors on the pole when they were not buried by snow, stored in Air_temperature_proxies_(site)_(start)_(end).csv (2) Ground interface temperature, recorded at 3 cm above the ground, stored in Ground_interface_temperature_(site)_(start)_(end).csv (3) Site characteristics, including vegetation height, elevation, and the topographic position index (TPI) within a 50 m radius, stored in Selected_probe_locations_gps_vegheight_tpi_elevation_(site).csv. These metrics were derived from 1 m resolution summer LiDAR-based digital elevation models and digital surface models from Singhania et al., 2023, DOI:10.5440/1832016. Metadata files include data descriptions (_dd.csv) for tabular data. All included files are listed and described in xxxx_flmd.csv.This dataset is an updated version of a previous archive (Wang et al., 2024b, DOI: 10.15485/2475020), incorporating multiple seasons and improved snow depth estimation. Please note that due to large amount of information present in this dataset, many specificities associated with the acquisition of snow temperature, air temperature proxy and estimation of snow depth, and the future archiving of additional datasets on the soil temperature, thaw depth and soil characteristics at these locations, the author would welcome being contacted by people planning to use this dataset.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Analytical Model for the Higher Order Moments of Midlatitude Atmospheric Temperature Distributions

Observed distributions of atmospheric temperature are non-Gaussian. Therefore, moments beyond variance are necessary in determining the frequency of extreme temperature events. Here we propose a simple kinematic model for atmospheric mid-latitude temperature variability based on symmetric advection from a non-symmetric background temperature profile. We then use this model to derive analytical expressions for the higher order moments of temperature distributions. Our results show that nonzero skewness and kurtosis arise due to the nonlinearity of the time-mean meridional temperature profile. The analytical model matches an idealized Held-Suarez atmospheric model, indicating nonlinearity of time-mean temperature in latitude is the dominant contribution to nonzero skewness and kurtosis in synoptic temperature variations. Model analysis further shows decrease in higher order moments due to climate change come roughly equally from changes in mixing length and changes in the background temperature profiles.

54 ENVIRONMENTAL SCIENCES↗

Theoretical and Experimental Temperature Distribution along a Plate

Existing equations for the temperature distribution along a plate produced by a point heat source are analyzed. Experimental values are compared with theoretical results from a formula employed in the development of a thermoelectric element for borehole use. On that basis, the influence of the heat-transfer coefficient on the calculated temperature distribution is established. In order to ensure agreement between the distribution calculated by the proposed formula and the experimental distribution, the value of the heat-transfer must be corrected.

42 ENGINEERING↗

Temperature distributions in the laser-heated diamond anvil cell from 3-D numerical modeling

We present TempDAC, a 3-D numerical model for calculating the steady-state temperature distribution for continuous wave laser-heated experiments in the diamond anvil cell. TempDAC solves the steady heat conduction equation in three dimensions over the sample chamber, gasket, and diamond anvils and includes material-, temperature-, and direction-dependent thermal conductivity, while allowing for flexible sample geometries, laser beam intensity profile, and laser absorption properties. The model has been validated against an axisymmetric analytic solution for the temperature distribution within a laser-heated sample. Example calculations illustrate the importance of considering heat flow in three dimensions for the laser-heated diamond anvil cell. In particular, we show that a “flat top” input laser beam profile does not lead to a more uniform temperature distribution or flatter temperature gradients than a wide Gaussian laser beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing soil water content variability across spatial scales from optimized high-resolution distributed temperature sensing technique

Fiber-optic Distributed Temperature Sensing, when combined with the Single-probe Heat-pulse technique can measure soil moisture (θ) across spatial scales. The key limitation of this system is in obtaining the relationship between soil thermal conductivity (λ) and θ for a specific field. Using the Department of Energy Atmospheric Radiation Measurement (ARM) site, this study tested a new methodology to account for the spatial variability in the λ-θ relationship using a Gaussian processes model. The resulting accurate θ measurements (RMSE = 0.03 m 3 m –3 ) were used to characterize the spatial variability of θ across scales and to develop an empirical equation that can correct for the changes in the θ spatial variability observed at different spatial resolutions. In addition, the number of required samples to accurately characterize θ and its variability over scales ranging from 5 m and 350 m were estimated. Finally, these findings provide key information to scale soil moisture from centimeters to hundreds of meters for process understanding.

54 ENVIRONMENTAL SCIENCES↗

Estimating Changes in Temperature Distributions in a Large Ensemble of Climate Simulations Using Quantile Regression

Understanding future changes in extreme temperature events in a transient climate is inherently challenging. A single model simulation is generally insufficient to characterize the statistical properties of the evolving climate, but ensembles of repeated simulations with different initial conditions greatly expand the amount of data available. In this paper, we present a new approach for using ensembles to characterize changes in temperature distributions based on quantile regression that more flexibly characterizes seasonal changes. Specifically, our approach uses a continuous representation of seasonality rather than breaking the dataset into seasonal blocks; that is, we assume that temperature distributions evolve smoothly both day to day over an annual cycle and year to year over longer secular trends. To demonstrate our method’s utility, we analyze an ensemble of 50 simulations of the Community Earth System Model (CESM) under a scenario of increasing radiative forcing to 2100, focusing on North America. As previous studies have found, we see that daily temperature bulk variability generally decreases in wintertime in the continental mid- and high latitudes (>40°). A more subtle result that our approach uncovers is that differences in two low quantiles of wintertime temperatures do not shrink as much as the rest of the temperature distribution, producing a more negative skew in the overall distribution. Although the examples above concern temperature only, the technique is sufficiently general that it can be used to generate precise estimates of distributional changes in a broad range of climate variables by exploiting the power of ensembles.

54 ENVIRONMENTAL SCIENCES↗

Simple method for highlighting the temperature distribution into a liquid sample heated by microwave power field

Microwave induced heating is widely used in medical treatments, scientific and industrial applications. The temperature field inside a microwave heated sample is often inhomogenous, therefore multiple temperature sensors are required for an accurate result. Nowadays, non-contact (Infra Red thermography or microwave radiometry) or direct contact temperature measurement methods (expensive and sophisticated fiber optic temperature sensors transparent to microwave radiation) are mainly used. IR thermography gives only the surface temperature and can not be used for measuring temperature distributions in cross sections of a sample. In this paper we present a very simple experimental method for temperature distribution highlighting inside a cross section of a liquid sample, heated by a microwave radiation through a coaxial applicator. The method proposed is able to offer qualitative information about the heating distribution, using a temperature sensitive liquid crystal sheet. Inhomogeneities as smaller as 1°-2°C produced by the symmetry irregularities of the microwave applicator can be easily detected by visual inspection or by computer assisted color to temperature conversion. Therefore, the microwave applicator is tuned and verified with described method until the temperature inhomogeneities are solved.

36 MATERIALS SCIENCE↗