Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TELLURIUM 130”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Potential neutron-induced γ-ray background on natural tellurium relevant to 130 Te 0 ν ββ decay searches at the CUORE and SNO+ detectors

Gamma-ray production cross-section data have been obtained for the inelastic neutron scattering reactions 126,128,130 Te(n,n'γ) at five neutron energies between 3.6 and 10 MeV. We report data for the γ-ray energy region relevant to 0ν ββ decay of 130 Te with a Q ββ value of 2527.515 keV, assuming natural-abundance tellurium, as used at CUORE and SNO+. The natural abundance of 130 Te, 128 Te, and 126 Te is 34%, 32%, and 19%, respectively. For CUORE the γ-ray cascades from the excited state in 130 Te at 2527.06 keV and in 126 Te at 2533.85 keV are of concern. For SNO+, accounting for its inferior energy resolution, an additional four levels are important in 130 Te, an additional nine levels in 128 Te, and an additional eight levels in 126 Te. Of these, we report neutron-induced γ-ray production cross sections for the strongest transitions: the 2581.15 keV level in 130 Te, the 2494.20, 2508.06, and 2630.14 keV levels in 128 Te, and the 2496.83 and 2585.46 keV level in 126 Te. Here, the largest cross-section values were found for cascade γ-ray transitions to the ground state, while direct transitions to the ground state are very weak and were not observed in the present work. Both the CUORE and SNO+ detectors, however, may not be able to distinguish between cascade transitions and direct transitions to the ground state, making the neutron-induced excitation of the 2527.06 keV state of 130 Te in particular a potential problem for 0νββ decay searches of 130Te, because it matches its Q ββ value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CUORE-0 results and prospects for the CUORE experiment

With 741 kg of TeO{sub 2} crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory for Rare Events) experiment aims at searching for neutrinoless double beta decay of {sup 130}Te with unprecedented sensitivity. Expected to start data taking in 2015, CUORE is currently in an advanced construction phase at LNGS. CUORE projected neutrinoless double beta decay half-life sensitivity is 1.6 × 10{sup 26} y at 1σ (9.5 × 10{sup 25} y at the 90 % confidence level), in five years of live time, corresponding to an upper limit on the effective Majorana mass in the range 40–100 meV (50–130 meV). Further background rejection with auxiliary bolometric detectors could improve CUORE sensitivity and competitiveness of bolometric detectors towards a full analysis of the inverted neutrino mass hierarchy. CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE experiment. It consists of a single CUORE tower (52 TeO{sub 2} bolometers of 750 g each, arranged in a 13 floor structure) constructed strictly following CUORE recipes both for materials and assembly procedures. An experiment its own, CUORE-0 is expected to reach a sensitivity to the ββ(0ν) half-life of {sup 130}Te around 3×10{sup 24} y in one year of live time. We present an update of the data, corresponding to an exposure of 18.1 kg y. An analysis of the background indicates that the CUORE performance goal is satisfied while the sensitivity goal is within reach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Search for Neutrinoless Double Beta Decay with 130 Te with CUORE-0

This thesis describes the design, operation and results of an experimental search for neutrinoless double beta decay (0$\nu\beta\beta$) of $^{130}$Te using the CUORE-0 detector. The discovery of 0$\nu\beta\beta$ would have profound implications for particle physics and our understanding of the Universe. Its discovery would demonstrate the violation of lepton number and imply that neutrinos are Majorana fermions and therefore their own anti-particles. Combined with other experimental results, the discovery of 0$\nu\beta\beta$ could also have implications for understanding the absolute neutrino mass scale as well as the presently unknown neutrino mass hierarchy. The CUORE experiment is a ton-scale search for 0$\nu\beta\beta$ in $^{130}$Te expected to begin operation in late 2015. The first stage of this experiment is a smaller 39-kg active-mass detector called CUORE-0. This detector contains 11 kg of $^{130}$Te and operates in the Laboratori Nazionali del Gran Sasso lab in Italy from 2013 -- 2015. The results presented here are based on a $^\text{nat}$TeO$_2$ exposure of 35.2 kg$\cdot$yr, or 9.8 kg$\cdot$yr exposure of $^{130}$Te collected between 2013 -- 2015. We see no evidence of 0$\nu\beta\beta$ and place an upper limit on the 0$\nu\beta\beta$ decay rate of $\Gamma_\text{0$\nu\beta\beta$}<0.25\times10^{-24}$ yr$^{-1}$ (90 % C.L.), corresponding to a lower limit on the half-life of $T^{0\nu}_{1/2}>2.8\times10^{24}$ yr (90 % C.L.). We combine the present result with the results of previous searches in $^{130}$Te. Combining it with the 1.2 kg$\cdot$yr $^{130}$Te exposure from the Three Towers Test run we place a half-life limit of $T_{1/2}^{0\nu}>3.3\times10^{24}$ yr (90 % C.L.). And combining these results with the 19.75 kg$\cdot$yr $^{130}$Te exposure from CUORE-0ino, we place the strongest limit on the 0$\nu\beta\beta$ half-life of $^{130}$Te to date, at $T^{0\nu}_{1/2}>4.5\times10^{24}$ yr (90 % C.L.). Using the present nuclear matrix element calculations for $^{130}$Te, this result corresponds to a 90 % upper limit range on the effective Majorana mass of $m_{\beta\beta}<250-710$ meV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematics of Evaluated Half-lives of Double-beta Decay

A new evaluation of 2β-decay half lives and their systematics is presented. These data extend the previous evaluation and include the analysis of all recent measurements. The nuclear matrix elements for 2β-decay transitions in 12 nuclei have been extracted. The recommended values are compared with the large-scale shell-model, QRPA calculations, and experimental data. A T{sub 1/2}{sup 2ν}∼1/E{sup 8} systematic trend has been observed for recommended {sup 128,130}Te values. This trend indicates similarities for nuclear matrix elements in Te nuclei and was predicted for 2β(2ν)-decay mode. The complete list of results is available online at (http://www.nndc.bnl.gov/bbdecay/)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Background reduction in the SNO+ experiment

SNO+ is a large multi-purpose liquid scintillator experiment, which first aim is to detect the neutrinoless double beta decay of {sup 130}Te. It is placed at SNOLAB, at 6000 m.w.e. and it is based on the SNO infrastructure. SNO+ will contain approximately 780 tonnes of liquid scintillator, loaded with {sup 130}Te inside an acrylic vessel (AV) with an external volume of ultra pure water to reduce the external backgrounds. Light produced in the scintillator by the interaction of particles will be detected with about 9,000 photomultiplier’s. For the neutrinoless double beta decay phase, due to its the extremely low rate expected, the control, knowledge and reduction of the background is essential. Moreover, it will also benefit other phases of the experiment focused on the study of solar neutrinos, nucleon decay, geoneutrinos and supernovae. In order to reduce the internal background level, a novel purification technique for tellurium loaded scintillators has been developed by the collaboration that reduces the U/Th concentration and several cosmic-activated isotopes by at least a factor 10{sup 2} -10{sup 3} in a single pass. In addition, different rejection techniques have been developed for the remaining internal backgrounds based on Monte-Carlo simulations. In this work, the scintillator purification technique and the levels obtained with it will be discussed. Furthermore, an overview of the different backgrounds for the double-beta phase will be presented, highlighting some of the techniques developed to reject the remained decays based on their expected timing differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNO+: Physics program and status update

Joining the current generation of neutrinoless double beta decay experiments, SNO+ is a kilotonne-scale liquid scintillator neutrino detector housed 2 km underground in Vale Canada Ltd’s Creighton Mine near Sudbury, Ontario, Canada. Through re-purposing existing hardware in place for the now decommissioned Sudbury Neutrino Observatory (SNO), and employing a rigourous materials purification and selection program, SNO+ will investigate neutrinoless double beta decay of {sup 130}Te. Owing to its size, SNO+ expects a sensitivity to the effective Majorana neutrino mass near 100 meV with a 0.3% loading of natural Te and several years of data collection. Designed as a general purpose detector, SNO+ also has a robust physics program that includes investigations of solar and supernova neutrinos, and reactor and geo anti-neutrinos. Construction of the detector is nearly complete, with the first water-fill commissioning phase set to begin at the end of this year and the neutrinoless double beta decay phase following in late 2014.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrinoless double-β decay and nuclear transition matrix elements

Within mechanisms involving the light Majorana neutrinos, squark-neutrino, Majorons, sterile neutrinos and heavy Majorana neutrino, nuclear transition matrix elements for the neutrinoless (β{sup −}β{sup −}){sub 0ν} decay of {sup 96}Zr, {sup 100}Mo, {sup 128,130}Te and {sup 150}Nd nuclei are calculated by employing the PHFB approach. Effects due to finite size of nucleons, higher order currents, short range correlations, and deformations of parent as well as daughter nuclei on the calculated matrix elements are estimated. Uncertainties in nuclear transition matrix elements within long-ranged mechanisms but for double Majoron accompanied (β{sup −}β{sup −}ϕϕ){sub 0ν} decay modes are 9%–15%. In the case of short ranged heavy Majorona neutrino exchange mechanism, the maximum uncertainty is about 35%. The maximum systematic error within the mechanism involving the exchange of light Majorana neutrino is about 46%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First neutrinoless double beta decay results from CUORE-0

The CUORE-0 experiment, a 52 bolometer array searching for neutrinoless double beta decay from {sup 130}Te, has started taking data in spring 2013 underground at the Laboratori Nazionali del Gran Sasso (LNGS). The excellent results obtained in terms of energy resolution and background level allowed this experiment to reach the sensitivity of Cuoricino in approximately half the runtime. Combining CUORE-0 data (9.8 kg·yr exposure of {sup 130}Te) with the 19.75 kg·yr exposure of the Cuoricino experiment, we obtain the most stringent limit to date on the half-life of this isotope (T{sub 1/2} > 4.0 × 10{sup 24} yr). In this article, we review the results from CUORE-0 and discuss the status and the physics potential of CUORE, a 19 times larger bolometer array that plans to begin operations by end of this year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy-element production in a compact object merger observed by JWST

The mergers of binary compact objects such as neutron stars and black holes are of central interest to several areas of astrophysics, including as the progenitors of gamma-ray bursts (GRBs), sources of high-frequency gravitational waves (GWs) and likely production sites for heavy-element nucleosynthesis by means of rapid neutron capture (the r -process). Here we present observations of the exceptionally bright GRB 230307A. We show that GRB 230307A belongs to the class of long-duration GRBs associated with compact object mergers and contains a kilonova similar to AT2017gfo, associated with the GW merger GW170817. We obtained James Webb Space Telescope (JWST) mid-infrared imaging and spectroscopy 29 and 61 days after the burst. The spectroscopy shows an emission line at 2.15 microns, which we interpret as tellurium (atomic mass A = 130) and a very red source, emitting most of its light in the mid-infrared owing to the production of lanthanides. These observations demonstrate that nucleosynthesis in GRBs can create r -process elements across a broad atomic mass range and play a central role in heavy-element nucleosynthesis across the Universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Current Status and Future Prospects of the SNO+ Experiment

SNO+ is a large liquid scintillator-based experiment located 2 km underground at SNOLAB, Sudbury, Canada. It reuses the Sudbury Neutrino Observatory detector, consisting of a 12 m diameter acrylic vessel which will be filled with about 780 tonnes of ultra-pure liquid scintillator. Designed as a multipurpose neutrino experiment, the primary goal of SNO+ is a search for the neutrinoless double-beta decay (0 ν β β ) of 130 Te. In Phase I, the detector will be loaded with 0.3% natural tellurium, corresponding to nearly 800 kg of 130 Te, with an expected effective Majorana neutrino mass sensitivity in the region of 55–133 meV, just above the inverted mass hierarchy. Recently, the possibility of deploying up to ten times more natural tellurium has been investigated, which would enable SNO+ to achieve sensitivity deep into the parameter space for the inverted neutrino mass hierarchy in the future. Additionally, SNO+ aims to measure reactor antineutrino oscillations, low energy solar neutrinos, and geoneutrinos, to be sensitive to supernova neutrinos, and to search for exotic physics. A first phase with the detector filled with water will begin soon, with the scintillator phase expected to start after a few months of water data taking. The 0 ν β β Phase I is foreseen for 2017.

36 MATERIALS SCIENCE↗

A scintillator purification plant and fluid handling system for SNO+

A large capacity purification plant and fluid handling system has been constructed for the SNO+ neutrino and double-beta decay experiment, located 6800 feet underground at SNOLAB, Canada. SNO+ is a refurbishment of the SNO detector to fill the acrylic vessel with liquid scintillator based on Linear Alkylbenzene (LAB) and 2 g/L PPO, and also has a phase to load natural tellurium into the scintillator for a double-beta decay experiment with {sup 130}Te. The plant includes processes multi-stage dual-stream distillation, column water extraction, steam stripping, and functionalized silica gel adsorption columns. The plant also includes systems for preparing the scintillator with PPO and metal-loading the scintillator for double-beta decay exposure. We review the basis of design, the purification principles, specifications for the plant, and the construction and installations. The construction and commissioning status is updated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for neutrinoless β-plus-EC decay of 120 Te with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale cryogenic experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than 130 Te. In this work we describe a search for neutrinoless positron-emitting electron capture (β + EC ) decay in 120 Te with a total TeO 2 exposure of 355.7 kg yr, corresponding to 0.2405 kg yr of 120 Te. Albeit 0νββ with two final-state electrons represents the most promising channel, the emission of a positron and two 511-keV γ 's make 0νβ + EC decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of 3.4 × 10 22 yr at 90% credibility interval (C.I.). After unblinding we find no evidence of 0νβ + EC signal and set a 90% C.I. Bayesian lower limit of 2.9 × 10 22 yr on 120 Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Results from the CUORE-0 experiment

The CUORE-0 experiment searched for neutrinoless double beta decay in 130 Te using an array of 52 tellurium dioxide crystals, operated as bolometers at a temperature of 10 mK. It took data in the Gran Sasso National Laboratory (Italy) since March 2013 to March 2015. We present the results of a search for neutrinoless double beta decay in 9.8 kg-years 130 Te exposure that allowed us to set the most stringent limit to date on this half-life. The performance of the detector in terms of background and energy resolution is also reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Initial performance of the CUORE-0 experiment

CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130 Te. We present the first data analysis with 7.1kg • y of total TeO 2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57MeV) and in the α background-dominated region (2.70 to 3.90MeV) have been measured to be 0.071±0.011 and 0.019±0.002counts/(keV • kg • y), respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural changes across thermodynamic maxima in supercooled liquid tellurium: a water-like scenario

Liquid polymorphism is an intriguing phenomenon which has been found in a few single-component systems, the most famous being water. By supercooling liquid Te to more than 130 K below its melting point and performing simultaneous small-angle and wide-angle X-ray scattering measurements, we observe clear maxima in its thermodynamic response functions around 615 K, suggesting the possible existence of liquid polymorphism. A close look at the underlying structural evolution shows the development of intermediate-range order upon cooling, most strongly around the thermodynamic maxima, which we attribute to bond-orientational ordering. The striking similarities between our results and those of water, despite the lack of hydrogen-bonding and tetrahedrality in tellurium, indicate that water-like anomalies may be a general phenomenon among liquid systems with competing bond- and density-ordering.

36 MATERIALS SCIENCE↗

Expected sensitivity to 128 Te neutrinoless double beta decay with the CUORE TeO 2 cryogenic bolometers

The CUORE experiment is a ton-scale array of TeO 2 cryogenic bolometers located at the underground Laboratori Nazionali del Gran Sasso of Istituto Nazionale di Fisica Nucleare (INFN), in Italy. The CUORE detector consists of 988 crystals operated as source and detector at a base temperature of ~ 10 mK. Such cryogenic temperature is reached and maintained by means of a custom built cryogen-free dilution cryostat, designed with the aim of minimizing the vibrational noise and the environmental radioactivity. The primary goal of CUORE is the search for neutrinoless double beta decay of 130 Te , but thanks to its large target mass and ultra-low background it is suitable for the study of other rare processes as well, such as the neutrinoless double beta decay of 128 Te. This tellurium isotope is an attractive candidate for the search of this process, due to its high natural isotopic abundance of 31.75%. The transition energy at (866.7 ± 0.7) keV lies in a highly populated region of the energy spectrum, dominated by the contribution of the two-neutrino double beta decay of 130 Te. As the first ton-scale infrastructure operating cryogenic TeO 2 bolometers in stable conditions, CUORE is able to achieve a factor > 10 higher sensitivity to the neutrinoless double beta decay of this isotope with respect to past direct experiments.

128-Te↗

Cosmogenic-neutron activation of TeO 2 and implications for neutrinoless double- β decay experiments

Flux-averaged cross sections for cosmogenic-neutron activation of natural tellurium were measured using a neutron beam containing neutrons of kinetic energies up to ~800 MeV, and having an energy spectrum similar to that of cosmic-ray neutrons at sea-level. Analysis of the radioisotopes produced reveals that 110m Ag will be a dominant contributor to the cosmogenic-activation background in experiments searching for neutrinoless double-beta decay of 130 Te, such as CUORE and SNO+. Here, an estimate of the cosmogenic-activation background in the CUORE experiment has been obtained using the results of this measurement and cross-section measurements of proton activation of tellurium. Additionally, the measured cross sections in this work are also compared with results from semi-empirical cross-section calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Te(IV) immobilization by siderite: Reaction kinetics, mechanism, and Te isotopic fractionation

Mining and industrial use over recent decades have released tellurium (Te) into the environment where it potentially contaminates soils, water supplies and food sources. Therefore, it is important to find ways of removing mobile and bioavailable Te from aqueous environments. Here, we report aqueous Te(IV) removal by siderite at varying Te concentrations (2, 6 and 10 mg mL –1 Te(IV)) and pH values (7, 7.9 and 9), together with associated isotope fractionation (ε 130 Te/ 125 Te). Our results show effective immobilization of Te(IV) that follows pseudo-first order rate kinetics. Formation of magnetite indicates reduction of Te(IV) on siderite surfaces and the formation of Te(0). The overall isotope fractionation (ε) is small (–0.23 ± 0.06‰) providing evidence that it is primarily controlled by adsorption of Te(IV) occurring simultaneously with reduction of Te(IV). Therefore, Te(IV) removal by siderite under mildly reducing ferruginous conditions may be identifiable by the characteristically small isotopic fractionation during both natural attenuation and active remediation. To our knowledge, this is the first study reporting reaction mechanisms of Te(IV) immobilization by an environmentally relevant Fe(II) mineral.

58 GEOSCIENCES↗