Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Microporous metal organic framework [M{sub 2}(hfipbb){sub 2}(ted)] (M=Zn, Co; H{sub 2}hfipbb=4,4-(hexafluoroisopropylidene)-bis(benzoic acid); ted=triethylenediamine): Synthesis, structure analysis, pore characterization, small gas adsorption and CO{sub 2}/N{sub 2} separation properties

Carbon dioxide is a greenhouse gas that is a major contributor to global warming. Developing methods that can effectively capture CO{sub 2} is the key to reduce its emission to the atmosphere. Recent research shows that microporous metal organic frameworks (MOFs) are emerging as a promising family of adsorbents that may be promising for use in adsorption based capture and separation of CO{sub 2} from power plant waste gases. In this work we report the synthesis, crystal structure analysis and pore characterization of two microporous MOF structures, [M{sub 2}(hfipbb){sub 2}(ted)] (M=Zn (1), Co (2); H{sub 2}hfipbb=4,4-(hexafluoroisopropylidene)-bis(benzoic acid); ted=triethylenediamine). The CO{sub 2} and N{sub 2} adsorption experiments and IAST calculations are carried out on [Zn{sub 2}(hfipbb){sub 2}(ted)] under conditions that mimic post-combustion flue gas mixtures emitted from power plants. The results show that the framework interacts with CO{sub 2} strongly, giving rise to relatively high isosteric heats of adsorption (up to 28 kJ/mol), and high adsorption selectivity for CO{sub 2} over N{sub 2}, making it promising for capturing and separating CO{sub 2} from CO{sub 2}/N{sub 2} mixtures. - Graphical abstract: Microporous [Zn{sub 2}(hfipbb){sub 2}(ted)] demonstrates high adsorption selectivity for CO{sub 2} over N{sub 2} under conditions that mimic flue gas mixtures. Highlights: ► Two new porous MOFs were synthesized and characterized by rational design. ► The small pore size leads to greatly enhanced CO{sub 2}–MOF interaction. ► High adsorption selectivity of the Zn–MOF for CO{sub 2} over N{sub 2} is achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the INL Thermal Energy Distribution System (TEDS) in the Modelica Eco-System for Validation and Verification

This report provides an overview on the development of the Thermal Energy Distribution System (TEDS) in the Modelica process model eco-system at Idaho National Laboratory as part of the integrated energy system initiative. Model development has led to the creation of a dynamic process model of the experimental TEDS facility housed within the Engineering Science Laboratory (ESL) at INL. The model was then used during the pre-construction phase of the experimental effort to inform experimental design (insulation requirements, bypass line placement, expected performance of components) and to test innovative control schemes prior to the initial operation. The TEDS model developed in Modelica includes the primary components of the TEDS experimental unit including: a 200kW Chromalox heater, a single-tank packed bed thermal energy storage system filled with 0.125 inch Alumina (Al 2 O 3 ), an ethylene-glycol to Therminol-66 heat exchanger, system piping, six control valves, and all associated temperature, pressure, and mass flow sensors. The model does not include nitrogen fill gas tanks, or associated overfill tanks, as these are not part of standard system control. Two simulation sets were run. The first is a five-hour test that operates as a shakedown test for the facility. This simulation puts the facility through all five potential operating modes and showcases the ability of valving, control sensors, and component controllers to meet the system demands. The second case imposes a typical summer day demand on the system from a region with mixed commercial and residential electrical needs where the generator alone cannot meet peak demand but instead requires the thermal storage unit to act as a peaking unit. Over the course of the fifteen-hour discharge cycle heat losses account for a heat loss of approximately 15°C in outlet temperature. Such heat losses would lead to a decrease in overall system efficiency and may lead to additional design changes for such designs in the future that may include a topping heater. Through commencement of this work, a systems level model of TEDS with associated control systems, sensors, piping diameters, and component capabilities has been created. This model has been utilized in the pre-experimental phase to inform system design, insulation thicknesses, and potential control schemes to operate the system effectively and safely. Once TEDS begins operation, this model will be refined, tuned, and used for validation and verification purposes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation and Verification for INL Modelica-based TEDS models Via Experimental Results

This report provides an overview on the verification and validation (V&V) of the Thermal Energy Distribution System (TEDS) model developed in the Modelica process modeling ecosystem using experimental data. Model development has led to the creation of a dynamic process model of the experimental TEDS facility housed within the Energy Systems Laboratory (ESL) at Idaho National Laboratory (INL). The model was then used during the preconstruction phase of the experimental effort to inform experimental design (e.g., insulation requirements, bypass line placement, expected performance of components) and to test innovative control schemes prior to the initial operation. The TEDS model developed in Modelica includes the primary components of the TEDS experimental unit: a 200kW Chromalox heater; a single-tank packed-bed thermal energy storage system filled with 0.125-inch alumina (Al2O3) beads; an ethylene-glycol-to-Therminol-66 heat exchanger; system piping; five control valves; and all associated temperature, pressure, and volumetric flow sensors. Using the Institute of Electrical and Electronics Engineers (IEEE) V&V methodologies, considered the gold standard in the engineering field, the model was verified using a combination of static analysis, spatial convergence, and regression tests. Then using dynamic time warping (DTW) initial runs to validate and tune the TEDS model versus the experiment were conducted. This tuning method was accomplished using the INL Risk Analysis Virtual ENvironment (RAVEN) software package. Tuning is required to account for physical phenomena that are less understood within the empirical heat transfer correlations. Through the commencement of this work, a systems-level model of TEDS with associated control systems, sensors, piping diameters, and component capabilities has been created. This model was utilized in the pre-experimental phase to inform system design, insulation thicknesses, and potential control schemes to operate the system effectively and safely. Then, initial experimental startup and operational data were used to demonstrate the validation and tuning methodology. This process demonstrates the classical two-step approach of a model informing experimental design followed by the experiment validation and tuning the model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TEDS Test Plan for Performance Characterization of Packed-bed Thermal Energy Storage Unit

This report proposes a set of test plans for performance measurement and characterization of the packed-bed thermal energy storage (TES) unit for TEDS. The main goals of this test plan are three-fold: (i) support the high-fidelity data measurement for TEDS, (ii) characterize thermal and structural performance of the TEDS TES unit, and (iii) produce high quality validation-oriented data. To achieve the goals, it is first suggested to revisit the instrument calibration and data sampling protocols applied during the startup and commissioning tests of TEDS, based on the observation from the recent CFD validation study using the TEDS TES operational data. The uncertainty quantification of the thermal and hydraulic measurements is also suggested. Lastly, test matrices are provided for charge, discharge, and standby modes of the packed-bed TES unit, respectively, to characterize the thermal and structural performances during the envisioned TEDS operations.

25 ENERGY STORAGE↗

Thermal Ratcheting Analysis of TEDS Packed-bed Thermocline Energy Storage Tank - Modeling Methodology and Data Validation

This report investigates numerical modeling methods for thermal ratcheting analysis of packed-bed thermal energy storage (TES) tank and discusses the validation results via comparison with experimental data. The experimental data obtained from various design characteristics of packed-bed thermocline tanks, including the Thermal Energy Distribution System (TEDS) TES tank at Idaho National Laboratory (INL), were used to validate thermal and mechanical models developed in this study to evaluate the thermal ratcheting potential. The thermal model was shown to predict the transient thermal propagation through the packed-bed thermocline tanks generally well. However, a larger discrepancy was observed during the comparison with the data from TEDS, presumably due to the uncertainty of boundary conditions given from the experiment. Based on the comparative study between the thermal model predictions and experimental data of various packed-bed thermocline tanks, potential improvements were suggested for the future TEDS experiments for more precise validation study. For mechanical (thermally induced stress) analysis, two different modeling approaches were tested to evaluate hoop stress applied to the packed-bed TES tank wall, which is a major cause of thermal ratcheting process: (i) infinite rigidity model and (ii) Drucker-Prager (DP) model. The ‘model (i)’ is a conservative method with infinite rigidity assumption of granular filler inside a TES tank, whereas the ‘model (ii)’ is a method that takes into account more realistic processes such as thermal expansion of filler and tank wall as well as inter-particle interactions during the cyclic operation of a packed-bed TES tank. The validity of each modeling method was examined by comparing the numerical simulation with the experimental data obtained from the packed-bed TES tank for Solar One pilot plant. Then, the effects of various model parameters were discussed to evaluate the thermal ratcheting potential of the TEDS TES tank. The preliminary thermal ratcheting analysis implies that the TEDS TES tank will hold its structural integrity during the normal operation cycles.

25 ENERGY STORAGE↗

Thermal Stress Modeling and Analysis of Packed-bed Thermocline Energy Storage Tank for INL Thermal Energy Distribution System (TEDS)

The Thermal Energy Distribution System (TEDS) at Idaho National Laboratory (INL) is a thermal-hydraulic flow loop to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit for TEDS. The packed-bed TES is adopted in TEDS because of its benefit as a low-cost single-tank storage option compared to the traditional two-tank storage. However, thermal ratcheting is one potential design concern which is caused by the rearrangement of granular filler inside a packed-bed tank during continuous thermal cycling operation of the packed-bed TES tank. If the thermally induced stress exceeds yield strength of the tank wall, it may cause catastrophic consequences like rupture of the thermal storage tank. Thus, it is crucial to understand the phenomenon to ensure the robust operation. Based on the temperature boundary conditions given by transient thermal analyses with computational fluid dynamics (CFD) simulations, the thermal ratcheting analysis is then conducted to evaluate the hoop stress and resultant thermal ratcheting potential of the TES tanks with two different modeling approaches: (1) infinite rigidity model and (2) Drucker-Prager (DP) model. The validity of each modeling method was examined by comparing the numerical simulation with the experimental data obtained from the packed-bed TES tank for Solar One Plant and evaluate the thermal ratcheting potential of the TEDS TES tank.

25 ENERGY STORAGE↗

Mechanism of Preferential Adsorption of SO 2 into Two Microporous Paddle Wheel Frameworks M(bdc)(ted) 0.5

The adsorption of a corrosive gas, SO 2 , into microporous pillared paddle-wheel frameworks M(bdc)(ted) 0.5 [M = Ni, , Zn; bdc = 1,4-benzenedicarboxylate; ted=triethylenediamine] is studied by volumetric adsorption measurements and a combination of in-situ infrared spectroscopy and ab initio density functional theory (DFT) calculations. The uptake of SO 2 in M(bdc)(ted) 0.5 at room temperature is quite significant, 9.966 mol kg -1 (63.8%) at room temperature/1.132 bar, which represents the highest SO 2 uptake so far observed. Two different adsorption species are identified by infrared spectroscopy: one is typical physisorbed SO 2 species, characterized by a modest red shift of S-O stretching bands (36 cm -1 for νas and 7 cm -1 for νs); the other characterized by adsorption bands at 1242 and 1105cm -1 and by a much higher (~150°C) temperature to completely remove. Theoretical calculations including van der Waals interactions (based on vdW-DF) indicate that the adsorption geometry of SO 2 involves one molecule bonding of its sulfur atom to the oxygen atom of the paddle-wheel building unit and its two oxygen atoms to the C-H groups of the organic linkers by formation of hydrogen bonds. Such a configuration results in a large distortion of benzene rings, which is consistent with the experimentally observed shift of the ring deformation mode. The simulated frequency shift of the SO 2 stretching bands by vdW-DF is in excellent agreement with spectroscopically measured value of physisorbed SO 2 . The IR absorptions at 1242 and 1105 cm -1 also suggest a stronger adsorption configuration, previously observed in SO 4 -like species involving two oxygen atoms of the paddle wheel building units. The adsorption configurations of SO 2 into M(bdc)(ted) 0.5 derived by infrared spectroscopy and vdW-DF calculations provide the understanding necessary to develop industrial processes for SO 2 removal using microporous paddle-wheel frameworks materials.

Tan, Kui↗

Validation and Verification of TEDS Facility HYBRID Modeling

The HYBRID modeling repository is an in-house developed library of models for selected integrated energy systems (IES) modelling. HYBRID models have been developed since 2015 to describe the physical operation of tightly coupled thermal systems including power generators, thermal transport systems, thermal storage, thermal-to-electric conversion systems, and other thermal applications. Here, validation and verification (V&V) capabilities are demonstrated using the Thermal Energy Distribution System (TEDS) at INL. Building upon prior work, the TEDS model has been updated and verified so that it better represents the installed system configuration and the operating control system. The model control system was changed to allow replication of actual experimental procedures. Experimental operations focusing primarily on thermocline tank performance were devised and performed. Several anomalies were found in the operation data of the experiment facility. V&V activities calibrating a selected input parameter are demonstrated on a single component as well as with a single parameter within the thermocline. Calibrating is then demonstrated on multiple components and a multi-parameter metric for the entire system. The validation methodology is successfully applied to validate the model with experimental data. It is also used to confirm a hypothesis behind one of the anomalies in experimental performance.

25 ENERGY STORAGE↗

Modifications to the Thermal Energy Distribution System (TEDS)

INL installed a new controls system and a flame detection system on TEDS as part of upgrades that will eventually allow unattended operation and integration with accessory systems, such as digital twins, or facilities in other locations. These upgrades resolve some corrective actions that came about when oil was spilled from a high-point vent during system startup testing.

42 ENGINEERING↗

Special Issue in Honor of Professor S. Ted Oyama: 2014 ACS Distinguished Researcher Award in Petroleum Chemistry and Storch Award in Fuel Science

This special issue of Topics in Catalysis honors Professor S. Ted Oyama for his Awards in Petroleum Chemistry and Fuel Science Research. These awards were celebrated at two American Chemical Society (ACS) symposia in 2014. First, the ACS’s Distinguished Research Award in Petroleum Chemistry Symposium, took place at the 247th ACS National Meeting in Dallas, TX, during March 17-19, 2014 and the second one, the ACS’s Storch Award in Fuel Science Symposium, took place at the 248th ACS National Meeting in San Francisco, CA, during August 10-12, 2014. Professor Oyama received the 2014 ACS Distinguished Research Award in Petroleum Chemistry ‘‘for his substantial contributions to the field of heterogeneous catalysis’’ including the discovery of highly active transition metal phosphide catalysts for hydrotreatment of petroleum and coal-derived feedstocks and biomass refining, the development of new compositions, and the understanding of their reaction mechanisms by in situ spectroscopic techniques at high temperatures and pressures of reaction. In light of this recognition, Professor Oyama was also awarded the 2014 ACS Storch Award in Fuel Science ‘‘for his broad contributions to the field of fuel science’’ including the production of hydrogen by catalytic reforming, selective oxidation of hydrocarbons, biomass conversion, their reaction kinetics and mechanisms, and spectrokinetic methods to study catalysts in situ at reaction conditions and theory and application of inorganic membranes for separation of hydrogen and fuel-relevant gases. Finally, this special issue consists of contributions by catalysis researchers who participated in the two ACS symposia honoring Professor Oyama’s Awards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Reduction of TED in Ion Implanted Silicon

The leading challenge in the continued scaling of junctions made by ion implantation and annealing is the control of the undesired transient enhanced diffusion (TED) effect. Spike annealing has been used as a means to reduce this effect and has proven successful in previous nodes. The peak temperature in this process is typically 1050 deg. C and the time spent within 50 deg. C of the peak is of the order of 1.5 seconds. As technology advances along the future scaling roadmap, further reduction or elimination of the enhanced diffusion effect is necessary. We have shown that raising the peak temperature to 1175 deg. C or more and reduction of the anneal time at peak temperature to less than a millisecond is effective in eliminating enhanced diffusion. We show that it is possible to employ a sequence of millisecond anneal followed by spike anneal to obtain profiles that do not exhibit gradient degradation at the junction and have junction depth and sheet resistance appropriate to the needs of future technology nodes. We have implemented millisecond annealing using a carbon dioxide laser to support high-volume manufacturing of 65 nm microprocessors and system-on-chip products. We further show how the use of molecular ion implantation to produce amorphousness followed by laser annealing to produce solid phase epitaxial regrowth results in junctions that meet the shallow depth and abruptness requirements of the 32 nm node.

36 MATERIALS SCIENCE↗

TEDS-SOEC Non-Fired Boiler Repurpose

A brief presentation of the project to re-purpose the non-fired boiler that was previously installed in the TEDS-SOEC connection—the slides outline the project timeline and technical steps required to finish this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pico-second laser materials interactions: mechanisms, material lifetime and performance optimization Ted Laurence(14-ERD-014)

Laser-induced damage with ps pulse widths straddles the transition from intrinsic, multiphoton ionization- and avalanche ionization-based ablation with fs pulses to defectdominated, thermal-based damage with ns pulses. We investigated the morphology and scaling of damage for commonly used silica and hafnia coatings as well as fused silica. Using carefully calibrated laser-induced damage experiments, in situ imaging, and high-resolution optical microscopy, atomic force microscopy, and scanning electron microscopy, we showed that defects play an important role in laser-induced damage for pulse durations as short as 1 ps. Three damage morphologies were observed: standard material ablation, ultra-high density pits, and isolated absorbers. For 10 ps and longer, the isolated absorbers limited the damage performance of the coating materials. We showed that damage resulting from the isolated absorbers grows dramatically with subsequent pulses for sufficient fluences. For hafnia coatings, we used electric field modeling and experiments to show that isolated absorbers near the surface were affected by the chemical environment (vacuum vs. air) for pulses as short as 10 ps. Coupled with the silica results, these results suggested that improvements in the performance in the 10 -60 ps range have not reached fundamental limits. These findings motivate new efforts, including a new SI LDRD in improving the laser-damage performance of multi-layer dielectric coatings. A damage test facility for ps pulses was developed and automated, and was used for testing production optics for ARC. The resulting software was transferred to other laser test facilities for fs pulses and multiple wavelengths with 30 ps pulses. Additionally, the LDRD supported the retention and promotion of an important staff scientist in high-resolution dynamic microscopy and laser-damage testing.

36 MATERIALS SCIENCE↗

Thermal Energy Distribution System (TEDS) Startup

The thermal energy distribution system was started to demonstrate preliminary system operability. Some construction and warranty repairs remain before the system can be fully tested and certified for operation.

25 ENERGY STORAGE↗

Message-Based SPDK Transport Utility (TED Report) [Slides]

The driving goal is to investigate the feasibility of a message-based data transport for SPDK. All of SPDK’s existing data transport protocols are “connection-based”, requiring a target to hold state for each connected client / initiator. At extreme scale, juggling these connections from a large number of initiators creates a performance bottleneck. Under a message-based paradigm, we can bypass this behavior, as all initiators share a global communication channel, held open for the entire run. In theory, this approach should minimize connection management overhead at extreme scale.

97 MATHEMATICS AND COMPUTING↗