Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TECHNETIUM 86”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A = 86

The experimental nuclear spectroscopic data for known nuclides of mass number 86 (Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo, Tc) have been evaluated and presented together with Adopted properties for levels and γ rays. New high-spin data are available for {sup 86}Se, {sup 86}Br, {sup 86}Kr, {sup 86}Sr, {sup 86}Y, {sup 86}Zr and {sup 86}Mo; and lifetime data for high-spin states in {sup 86}Y and {sup 86}Zr. No significant new data since the 2001 NDS for A=86 have been reported for {sup 86}Rb and {sup 86}Nb. No data are yet available for excited states in {sup 86}Ga and {sup 86}As. The decay scheme of radioactive {sup 86}Ge is unknown, while those for {sup 86}Ga, {sup 86}As, 47.4 min isomer of {sup 86}Y, {sup 86}Nb and {sup 86}Tc are deemed as incomplete. Isomerism in {sup 86}Nb remains unconfirmed. This work supersedes the data presented in the previous NDS evaluation of A=86 published by 2001Si43.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isomeric states in neutron-deficient A{approx}80-90 nuclei populated in the fragmentation of {sup 107}Ag

The relativistic projectile fragmentation of a 750 MeV per nucleon beam of {sup 107}Ag was used to populate isomeric states in neutron-deficient nuclei around A=80-90. Reaction products were separated and unambiguously identified using the GSI FRagment Separator (FRS) and its ancillary detectors. At the final focal plane, the fragments were slowed from relativistic energies by means of an aluminium degrader and implanted in a passive stopper in the center of the high-efficiency, high-granularity Stopped Rare Isotope Spectroscopic INvestigation at GSI (RISING) germanium array. This allowed the identification of excited states in the N=Z nuclei {sub 43}{sup 86}Tc and, for the first time, {sub 41}{sup 82}Nb. Isomeric states have also been identified for the first time in {sup 87,88}Tc, and a previously unreported isomer was observed in {sup 84}Nb. Experimental results are presented along with a discussion on the structure of these nuclei based on interpretations provided by several theoretical models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of isomeric ratios for medium-mass nuclei

Values of the isomeric ratios for product nuclei originating from simple charge-exchange reactions were analyzed. The cross sections for the formation of product nuclei in ground and isomeric states were calculated with the aid of the TALYS 1.4 and EMPIRE 3.2 codes. The calculated values of the isomeric ratios were compared with their experimental counterparts taken from the EXFOR database. For the {sup 86,87}Y, {sup 94,95,96,99}Tc, and {sup 44}Sc nuclei, the experimental values of the isomeric ratios exceed the respective calculated values. The nuclei in question feature weak deformations and have high-spin yrast lines and rotational bands. The possible reason behind the discrepancy between theoretical and experimental isomeric ratios is that the decay of yrast states leads with a high probability to the formation of isomeric states of detected product nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radioguided localisation of impalpable breast lesions using 99m-Technetium macroaggregated albumin: Lessons learnt during introduction of a new technique to guide preoperative localisation

Preoperative wire-guided localisation (WGL) of impalpable breast lesions is widely used but can be technically difficult. Risks include wire migration, inaccurate placement, and inadequate surgical margins. Research shows that radioguided occult lesion localisation (ROLL) is quicker, easier, and can improve surgical and cosmetic outcomes. An audited introduction of ROLL was conducted to validate the technique as a feasible alternative to WGL. Fifty patients with single impalpable lesions and biopsy proven malignancy or indeterminate histology underwent WGL followed by intralesional radiopharmaceutical injection of 99m-Technetium macroaggregated albumin. Postprocedural mammography was performed to demonstrate wire position, and scintigraphy to evaluate radiopharmaceutical migration. Lymphoscintigraphy and intraoperative sentinel node biopsy were performed if indicated, followed by lesion localisation and excision using a gamma probe. Specimen imaging was performed, with immediate reexcision for visibly inadequate margins. Accurate localisation was achieved in 86% of patients with ROLL compared to 72% with WGL. All lesions were successfully removed, with clear margins in 71.8% of malignant lesions. Reexcision and intraoperative sentinel node localisation rates were equivalent to preaudit figures for WGL. ROLL was easy to perform and problems were infrequent. Inaccurate radiopharmaceutical placement necessitating WGL occurred in four patients. Minor radiopharmaceutical migration was common, but precluded using ROLL in only two cases. ROLL is effective, simple, inexpensive, and easily learnt; however, preoperative confirmation of correct radiopharmaceutical placement using mammography and the gamma probe is important to help ensure successful lesion removal. Insertion of a backup hookwire is recommended during the initial introduction of ROLL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Durable Tellurite Glasses for Vitrification of Technetium Wastes - 18270

Technetium-99 (Tc-99) can bring a significant environmental risk because it has a long half-life and high fission yield. The present work has developed alumino tellurite glass to immobilize Tc wastes generated by the pyrochemical processing technology. Rhenium (Re) was used as a non-radioactive surrogate for Tc. The Re{sub 2}O{sub 7} concentration in the tellurite glasses was as high as 9.11 mass% with retention of 86% on average. X-ray absorption spectroscopy analysis revealed that Re exists as Re{sup 7+} and is surrounded by 4 oxygen atoms. The 7-day PCT results were satisfied with the immobilized low-activity waste regulatory limit with Ca(ReO{sub 4}){sub 2} content less than 12 mass%. The long-term dissolution test was conducted for 256 days and a rate drop has occurred in which the rate of leaching gradually decreased. An alteration layer depleted soluble element was observed on the leached glass surface. These results suggest that tellurite glass can be a good candidate as a matrix for immobilizing Tc. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance characteristics of dedicated molecular breast imaging systems at low doses

Purpose: The purpose of this study was to compare the system performance characteristics and lesion detection capability of two molecular breast imaging (MBI) systems: a multicrystal sodium iodide (NaI)-based single-head system and a cadmium zinc telluride (CZT)-based dual-head system at low administered doses (150–300 MBq) of Tc-99m sestamibi. Methods: System performance characteristics including count sensitivity, uniformity, energy resolution, and spatial resolution were measured using standard NEMA methods, or a modified version thereof in cases where the standard NEMA protocol could not be applied. A contrast-detail phantom with 48 lesions at varying depths from the collimator surface was used to assess lesion contrast-to-noise-ratio (CNR) using background count densities comparable to those observed in patient studies performed with administered doses of 150 MBq Tc-99m sestamibi. Lesions with CNR >3 were deemed to be detectable. Thirty patients undergoing MBI examinations with administered doses of 150–300 MBq were scanned for an additional view on the pixelated NaI system. CNR was calculated for lesions observed on patient images. Background count densities of patient images were measured and compared between the two systems. Results: Over the central field of view, integral and differential uniformity were 6.1% and 4.2%, respectively, for the pixelated NaI system, and 3.8% and 2.7%, respectively, for the CZT system. Count sensitivity was 10.8 kcts/min/MBq for the NaI system and 32.9 kcts/min/MBq for the CZT system. Energy resolution was 13.5% on the pixelated NaI system and 4.5% on the CZT system. Spatial resolution (full-width at half-maximum) for the pixelated NaI detector was 4.2 mm at a distance of 1.2 cm from the collimator and 5.2 mm at 3.1 cm. Spatial resolution of a single CZT detector was 2.9 mm at a distance of 1.2 cm from the collimator and 4.7 mm at 3.1 cm. Effective spatial resolution obtained with dual-head CZT was below 4.7 mm throughout a simulated breast thickness of 6 cm. From contrast-detail phantom images of lesions at distances of 1.5–4.5 cm from the collimator face, the CZT system detected 124 of 144 (86%) of lesions compared to 97 of 144 (67%) with the NaI system. In patient studies, from comparison of the same view with both systems, a total of 7 breast lesions were identified on CZT system in seven patients, and 4 of 7 (57%) were detected on NaI system. Patient image background count densities on the CZT system were on average 3.4 times higher than those on the NaI system. Conclusions: The CZT system demonstrated better uniformity, count sensitivity, spatial resolution, energy resolution, and lesion detection in phantom and patient studies compared to the NaI system. At administered doses of 150–300 MBq Tc-99m sestamibi, patient results obtained with CZT systems may not be directly translatable to NaI systems.

60 APPLIED LIFE SCIENCES↗

Iron Phosphate Glass for Vitrifying Hanford AZ102 LAW in Joule Heated and Cold Crucible Induction Melters - 12240

An iron phosphate composition for vitrifying a high sulfate (∼17 wt%) and high alkali (∼80 wt%) Hanford low activity waste (LAW), known as AZ-102 LAW, has been developed for processing in a Joule Heated Melter (JHM) or a Cold Crucible Induction Melter (CCIM). This composition produced a glass waste form, designated as MS26AZ102F-2, with a waste loading of 26 wt% of the AZ-102 which corresponded to a total alkali and sulfate (represented as SO{sub 3}) content of 21 and 4.4 wt%, respectively. A slurry (7 M Na{sup +}) of MS26AZ102F-2 simulant was melted continuously at temperatures between 1030 and 1090 deg. C for 10 days in a small JHM at PNNL and for 70 hours in a CCIM at INL. The as-cast glasses produced in both melters and in trial laboratory experiments along with their canister centerline cooled (CCC) counterparts met the requirements for the Product Consistency Test (PCT) and the Vapor Hydration Test (VHT) responses in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Contract. These glass waste forms retained up to 77 % of the SO{sub 3} (3.3 wt%), 100% of the Cesium, and 33 to 44% of the rhenium (used as a surrogate for Tc) all of which either exceeded or were comparable to the retention limit for these species in borosilicate glass nuclear waste form. Analyses of commercial K-3 refractory lining and the Inconel 693 metal electrodes used in JHM indicated only minimum corrosion of these components by the iron phosphate glass. This is the first time that an iron phosphate composition was melted continuously in a slurry fed JHM and in the US, thereby, demonstrating that iron phosphate glasses can be used as alternative hosts for vitrifying nuclear waste. The following conclusions are drawn from the results of the present work. (1) An iron phosphate composition, designated as MS26AZ102F-2, containing 26 wt% of the simulated high sulfate (17 wt%), high alkali (80 wt%) Hanford AZ-102 LAW meets all the criteria for processing in a JHM and CCIM. This composition produces a homogeneous glass with a density of 2.80 ± 0.04 g/cm{sup 3} after melting between 1000 and 1050 deg. C for 3 to 5 h. (2) This is the first time that an iron phosphate glass was melted in the JHM continuously for 10 days achieving a specific melting rate of 1010 kg/m2/day and in the CCIM for 70 hrs with a melting rate of 664 kg/m{sup 2}/day. (3) The analyzed (ICP-AES) compositions for all the glasses prepared under several melting conditions are in excellent agreement with the target composition. The variation of melting conditions include: (i) use of small scale/short melting time to large scale/long melting time (300 g to 80 kg, 4 h to 10 days) operations including melting in the JHM and CCIM, (ii) use of dry or wet (slurry) melter feed, (iii) addition of reductant (sugar) in the batch, and (iv) bubbling the melt with air. (4) The chemical durability as measured by PCT and VHT for the quenched and CCC-treated waste forms prepared from laboratory, JHM or CCIM melting exceeds the DOE requirements for LAW. (5) Depending upon the melting time (4 h to 10 days), the average concentration of SO{sub 3} in the MS26AZ102F-2 iron phosphate glass waste form varies from about 1.78 (RSM) to 3.74 (laboratory melt) wt% which corresponds to an SO{sub 3} retention of 41 to 86% when melted between 1030 at 1050 deg. C in air. (6) The retention of SO{sub 3} in the glass was reduced when a reductant (sugar) was added to the slurry. (7) The retention of other problem components like Cesium and Rhenium/Tc-99 is also high; from 92 to 100% for Cs{sub 2}O under different melting conditions, and from 66 to 33% for Re{sub 2}O{sub 7} for melts processed from 3 to 5 hours and up to 10 days. (8) Corrosion tests on Inconel 693 and K-3 refractory at temperatures between 1000 and 1050 deg. C indicate that both materials should be suitable for melting iron phosphate glasses. (9) The viscosity and electrical conductivity of the MS26AZ102F-2 melt are within the acceptable limits for RSM and CCIM processing. (10)This work has shown that iron phosphate compositions are a potential alternative to borosilicate glasses for vitrifying problematic wastes such as Hanford AZ-102 LAW that contains high amounts sulfate and alkali oxides, and that iron phosphate melts such as MS26AZ102F-2 can be processed in the JHM or CCIM. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗