Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TBS POPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Quantitative insights into the dislocation source behavior of twin boundaries suggest a new dislocation source mechanism

Pop-in statistics from nanoindentation with spherical indenters are used to determine the stress required to activate dislocation sources in twin boundaries (TBs) in copper and its alloys. The TB source activation stress is smaller than that needed for bulk single crystals, irrespective of the indenter size, dislocation density and stacking fault energy. Because an array of pre-existing Frank partial dislocations is present at a TB, we propose that dislocation emission from the TB occurs by the Frank partials splitting into Shockley partials moving along the TB plane and perfect lattice dislocations, both of which are mobile. The proposed mechanism is supported by recent high resolution transmission electron microscopy images in deformed nanotwinned (NT) metals and may help to explain some of the superior properties of nanotwinned metals (e.g. high strength and good ductility), as well as the process of detwinning by the collective formation and motion of Shockley partial dislocations along TBs.

36 MATERIALS SCIENCE↗

Portable Optical Particle Spectrometer aboard an Airborne Platform (POPS_AIR) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility portable optical particle spectrometer (POPS) is a lightweight particle spectrometer designed for aerosol particle size distribution measurement. Several POPS of different versions have been procured to serve as routine instruments for the ARM Aerial Facility (AAF) unmanned aerial systems (UAS) and tethered balloon system (TBS) deployment since 2018. POPS measures the aerosol particle size distribution approximately between 0.13 and 3 μm.

54 ENVIRONMENTAL SCIENCES↗

Fluorescent Particle Vertical Profiles (Counts and Fractions) at SAIL

This dataset contains vertically resolved fluorescent aerosol number concentrations and fluorescent fractions of total aerosol number concentrations measured with the ARM Tethered Balloon System during the Surface Atmosphere Integrated Field Laboratory campaign near Gothic, Colorado. Measurements were collected during April and June 2023 as part of the ARM–EMSL FICUS project “Characterization of the Aerobiome during the ARM Surface-Atmosphere Integrated Laboratory Campaign,” which was designed to characterize the vertical distribution of bioaerosol-relevant particles in the Colorado River Basin. The dataset includes profiles of fluorescent particle concentrations measured with a Fluorescent Portable Optical Particle Sizer (FPOPS) in the approximately 0.5–3 µm diameter range. For fluorescent fractions of total aerosol number concentrations, we compare FPOPS measurements to POPS on the same TBS flight.

Fluorescent particle concentration↗

Performance Assessment of Portable Optical Particle Spectrometer (POPS)

Accurate representation of atmospheric aerosol properties is a long-standing problem in atmospheric research. Modern pilotless aerial systems provide a new platform for atmospheric in situ measurement. However, small airborne platforms require miniaturized instrumentation due to apparent size, power, and weight limitations. A Portable Optical Particle Spectrometer (POPS) is an emerged instrument to measure ambient aerosol size distribution with high time and size resolution, designed for deployment on a small unmanned aerial system (UAS) or tethered balloon system (TBS) platforms. This study evaluates the performance of a POPS with an upgraded laser heater and additional temperature sensors in the aerosol pathway. POPS maintains its performance under different environmental conditions as long as the laser temperature remains above 25 °C and the aerosol flow temperature inside the optical chamber is 15 °C higher than the ambient temperature. The comparison between POPS and an Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) suggests that the coincidence error is less than 25% when the number concentration is less than 4000 cm –3 . The size distributions measured by both of them remained unaffected up to 15,000 cm –3 . While both instruments’ sizing accuracy is affected by the aerosol chemical composition and morphology, the influence is more profound on the POPS.

47 OTHER INSTRUMENTATION↗