Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System dependency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Beam-energy and collision-system dependence of the linear and mode-coupled flow harmonics from STAR

Recent measurements and hydrodynamic model calculations suggest that the higher-order flow coefficients ν 4 and ν 5 have two contributions: a linear contribution driven by the initial-state eccentricities, εn, and a mode-coupled contribution derived from the lower-order eccentricity coefficients ε 2 and ε 3 . Measurements of these two contributions to ν 4 and ν 5 provide crucial insights to discern initial-state models and to constrain the temperature-dependent specific shear viscosity, η/s, of the plasma produced in heavy-ion collisions. In this work, we have employed the two-subevents cumulant technique to provide the first beam-energy and collision-system dependence of the linear and mode-coupled contributions to the higher-order flow harmonics. Furthermore, our results are shown and discussed for several centrality intervals for U+U collisions at √s NN = 193GeV, Au+Au collisions at √s NN = 200 ,and 54.4GeV and Cu+Au collisions at √s NN = 200GeV. The results are compared with similar studies performed by the ALICE experiment at LHC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resiliency-based restoration optimization for dependent network systems against cascading failures

Due to the increasing importance of large-scale and complex network systems and the potential for massive cascading failures in these real-world systems, modeling of system resiliency and optimization of restoration strategies to mitigate system performance loss caused by diverse disruptions is of significant interest among researchers and practitioners. Although society has experienced many incidents that demonstrate the influence of cascading failures aggravated by dependencies inside network systems, existing resiliency-based restoration optimization research rarely if ever jointly considers the impact of system dependencies on cascading failures. In this paper, different restoration prioritization strategies are applied to network systems subject to cascading failures that take into account system dependencies. By conducting case studies on synthetic networks and the U.S. airport network system, the effects of restoration strategies are evaluated using a system resiliency metric and two system performance measurements. Furthermore, the influence of system dependency characteristics and the interplay between them and restoration strategies on system resiliency regarding cascading failures are also investigated. This work demonstrates the distinct effects of restoration prioritization actions against cascading failures to mitigate the performance loss in network systems with different properties. It also provides insights about restoration improvement by considering dependency impacts to effectively reduce the intensity and extent of cascading failures.

42 ENGINEERING↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM's existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

batteries↗

Bayesian learning with Gaussian processes for low-dimensional representations of time-dependent nonlinear systems

This work presents a data-driven method for learning low-dimensional time-dependent physics-based surrogate models whose predictions are endowed with uncertainty estimates. We use the operator inference approach to model reduction that poses the problem of learning low-dimensional model terms as a regression of state space data and corresponding time derivatives by minimizing the residual of reduced system equations. Standard operator inference models perform well with accurate training data that are dense in time, but producing stable and accurate models when the state data are noisy and/or sparse in time remains a challenge. Another challenge is the lack of uncertainty estimation for the predictions from the operator inference models. Our approach addresses these challenges by incorporating Gaussian process surrogates into the operator inference framework to (1) probabilistically describe uncertainties in the state predictions and (2) procure analytical time derivative estimates with quantified uncertainties. The formulation leads to a generalized least-squares regression and, ultimately, reduced-order models that are described probabilistically with a closed-form expression for the posterior distribution of the operators. The resulting probabilistic surrogate model propagates uncertainties from the observed state data to reduced-order predictions. Furthermore, we demonstrate the method is effective for constructing low-dimensional models of two nonlinear partial differential equations representing a compressible flow and a nonlinear diffusion–reaction process, as well as for estimating the parameters of a low-dimensional system of nonlinear ordinary differential equations representing compartmental models in epidemiology.

Data-driven model reduction↗

System-size dependence of charged-particle suppression in ultrarelativistic nucleus-nucleus collisions

High-energy partons lose energy while propagating through the hot, strongly interacting medium produced in ultrarelativistic nucleus-nucleus collisions, leading to a suppression of particle production at high transverse momentum (p T ). The dependence of this energy loss on the size of the colliding nuclear system has yet to be firmly established experimentally. This Letter presents a systematic study of charged-particle suppression across four different nucleus-nucleus collision systems using nuclear modification factors (R AA ) measured by the CMS Collaboration at the CERN LHC. Previous CMS measurements of R AA in oxygen-oxygen, xenon-xenon, and lead-lead collisions are recast with identical p T intervals and are complemented by the first measurement of the charged-particle R AA in neon-neon collisions at $\sqrt{S_{NN}}$ = 5.36 Te V . The neon-neon data correspond to an integrated luminosity of 0.76 nb −1 . The R AA in all collision systems examined show similar qualitative trends as a function of p T , but have a magnitude which is ordered with the nucleon number A. The R AA feature a downward slope at low p T , a local minimum at around 5–7 Ge V , and an upward slope with increasing p T . The R AA are also compared in terms of A 1/3 , which is proportional to the nuclear radius. Models including only initial-state nuclear effects fail to reproduce the observed trends, whereas energy loss models reproduce the trends in the region p T > 9.6 Ge V .

CMS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System-size dependence of the hadronic rescattering effect at energies available at the CERN Large Hadron Collider

The first measurements of K * ( 892 ) 0 resonance production as a function of charged-particle multiplicity in Xe-Xe collisions at s N N = 5.44 TeV and p p collisions at s = 5.02 TeV using the ALICE detector are presented. The resonance is reconstructed at midrapidity ( | y | < 0.5) using the hadronic decay channel K * 0 → K ± π ∓ . Measurements of transverse-momentum integrated yield, mean transverse-momentum, nuclear modification factor of K * 0 , and yield ratios of resonance to stable hadron ( K * 0 / K ) are compared across different collision systems ( p p , p -Pb, Xe-Xe, and Pb-Pb) at similar collision energies to investigate how the production of K * 0 resonances depends on the size of the system formed in these collisions. The hadronic rescattering effect is found to be independent of the size of colliding systems and mainly driven by the produced charged-particle multiplicity, which is a proxy of the volume of produced matter at the chemical freeze-out. In addition, the production yields of K * 0 in Xe-Xe collisions are utilized to constrain the dependence of the kinetic freeze-out temperature on the system size using the hadron resonance gas–partial chemical equilibrium model. ©2024 CERN, for the ALICE Collaboration 2024 CERN

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System-size dependence of the charged-particle pseudorapidity density at $\sqrt{s_{NN}}$ = 5.02 TeV for pp, p–Pb, and Pb–Pb collisions

We present the first systematic comparison of the charged-particle pseudorapidity densities for three widely different collision systems, pp, p–Pb, and Pb–Pb, at the top energy of the Large Hadron Collider ($\sqrt{s_{NN}}$ = 5.02 TeV) measured over a wide pseudorapidity range (-3.5 < η < 5), the widest possible among the four experiments at that facility. The systematic uncertainties are minimised since the measurements are recorded by the same experimental apparatus (ALICE). The distributions for p–Pb and Pb–Pb collisions are determined as a function of the centrality of the collisions, while results from pp collisions are reported for inelastic events with at least one charged particle at midrapidity. The charged-particle pseudorapidity densities are, under simple and robust assumptions, transformed to charged-particle rapidity densities. This allows for the calculation and the presentation of the evolution of the width of the rapidity distributions and of a lower bound on the Bjorken energy density, as a function of the number of participants in all three collision systems. We find a decreasing width of the particle production, and roughly a smooth ten fold increase in the energy density, as the system size grows, which is consistent with a gradually higher dense phase of matter

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generative learning for slow manifolds and bifurcation diagrams

In dynamical systems characterized by separation of time scales, the approximation of so called “slow manifolds”, on which the long term dynamics lie, is a useful step for model reduction. Initializing on such slow manifolds is a useful step in modeling, since it circumvents fast transients, and is crucial in multiscale algorithms (like the equation-free approach) alternating between fine scale (fast) and coarser scale (slow) simulations. In a similar spirit, when one studies the infinite time dynamics of systems depending on parameters, the system attractors (e.g., its steady states) lie on bifurcation diagrams (curves for one-parameter continuation, and more generally, on manifolds in state parameter space. Sampling these manifolds gives us representative attractors (here, steady states of ODEs or PDEs) at different parameter values. Algorithms for the systematic construction of these manifolds (slow manifolds, bifurcation diagrams) are required parts of the “traditional” numerical nonlinear dynamics toolkit. In more recent years, as the field of Machine Learning develops, conditional score-based generative models (cSGMs) have been demonstrated to exhibit remarkable capabilities in generating plausible data from target distributions that are conditioned on some given label. It is tempting to exploit such generative models to produce samples of data distributions (points on a slow manifold, steady states on a bifurcation surface) conditioned on (consistent with) some quantity of interest (QoI, observable). In this work, we present a framework for using cSGMs to quickly (a) initialize on a low-dimensional (reduced-order) slow manifold of a multi-time-scale system consistent with desired value(s) of a QoI (a “label”) on the manifold, and (b) approximate steady states in a bifurcation diagram consistent with a (new, out-of-sample) parameter value. This conditional sampling can help uncover the geometry of the reduced slow-manifold and/or approximately “fill in” missing segments of steady states in a bifurcation diagram. Finally, the quantity of interest, which determines how the sampling is conditioned, is either known a priori or identified using manifold learning-based dimensionality reduction techniques applied to the training data.

Dynamical systems↗

Protection of Inverter-Dependent Transmission Systems (PROTECT-IT)

This presentation highlights the overall objectives of the SETO funded protection project. The main technical approaches are also highlighted. This high impact project produces multiple innovative outcomes, including comprehensive impact study of how IBR affects protection elements, simplified low-order IBR model for protection engineers, enhanced and data-driven protection design, co-design concept for coordination protection and IBRs.

14 SOLAR ENERGY↗

Performance Analysis of Speculative Parallel Adaptive Local Timestepping for Conservation Laws

Stable simulation of conservation laws, such as those used to model fluid dynamics and plasma physics applications, requires the satisfaction of the so-called Courant-Friedrichs-Lewy condition. By allowing regions of the mesh to advance with different timesteps that locally satisfy this stability constraint, significant work reduction can be attained when compared to a time integration scheme using a single timestep size. However, parallelizing this algorithm presents considerable difficulty. Since the stability condition depends on the state of the system, dependencies become dynamic and potentially non-local. In this article, we present an adaptive local timestepping algorithm using an optimistic (Timewarp-based) parallel discrete event simulation. We introduce waiting heuristics to limit misspeculation and a semi-static load balancing scheme to eliminate load imbalance as parts of the mesh require finer or coarser timesteps. Last, we outline an interface for separating the physics of the specific conservation law from the temporal integration allowing for productive adoption of our proposed algorithm. We present a misspeculation study for three conservation laws, demonstrating both the productivity of the local timestepping API, for which 74% of the lines of code are reused across different conservation laws, and the robustness of the waiting heuristics—at most 1.5% of element updates are rolled back. Our performance studies demonstrate up to a 2.8× speedup versus a baseline unoptimized local timestepping approach, a 4x improvement in per-node throughput compared to an MPI parallelization of synchronous timestepping, and scalability up to 3,072 cores on NERSC’s Cori Haswell partition.

97 MATHEMATICS AND COMPUTING↗

Resilient U.S. Land Ports of Entry

The continued operation of Land Ports of Entry (LPOE), managed by the Customs and Border Protection (CBP) and General Services Administration% is vital to the U.S. economy and security. Border faculties are included in the Department of Homeland Security (DHS) Government Facilities Sector2, one of the 16 critical infrastructures "whose assets, systems, and networks, whether physical or virtual, are considered so vital to the United States that their incapacitation or destruction would have a debilitating effect on security, national economic security, national public health or safety, or any combination thereof.'" Specifically, disruptions to the flow of border crossing traffic, in the form of closures or increased border crossing wait times, impact the economy and security of all countries involved. This paper describes a process for analyzing and improving the resilience of U.S. Land Ports of Entry. For LPOE, the team believes that energy resilience is the primary objective due to the complete reliance on the e-manifest system and the increasing use of Multi-Energy Portals (MEPs). Emanifests are part of CPB's Automated Commercial Environment (ACE). They document several key pieces of information about cargo vehicles wishing to cross the border into the United States and are submitted before arriving at the port. Vehicles can be flagged for more invasive inspection based on the content of the e-manifest. MEPs are a non-intrusive inspection (NII) technology used to scan the contents of the cargo. Together MEPs and ACE serve an important role in aiding CBP with their mission to protect "the public from dangerous people and materials", and "enabling legitimate trade and travel.'" To analyze resilience of a port, the team would need to understand the port's current energy usage, which systems depend on energy and what backup systems exist, and any emergency operation plans that dictate how systems are operated in the event of a power outage. The team would also need to determine the design basis threats (DBTs) for the LPOE which could include natural disasters, manmade events, and accidents. The magnitudes of the DBTs are calculated and are then translated to expected impacts on the infrastructure and systems at the port. With this information gathered, existing LPOE models developed here at Sandia National Laboratories could be extended to support decisions about resilience. Current models are implemented in FlexSim, a 3rd party discrete event simulator. FlexSim provides 3-D visuals of physical layout that can reveal valuable insights, allows input to be variable (e.g. time it takes to interact with the CBP officer at primary inspection can vary) so that a whole range of possibilities can be captured in the results, and can be used to collect user-defined output metrics. Current LPOE models focus on cargo vehicle traffic, and process changes caused by the installation of new drive-through MEPs. Extending them to address resilience questions would require the addition of key pieces of information learned during the resilience analysis including critical systems, failure rates, and process changes for when failures occur. The primary output metric for current models is border crossing wait time. Additional metrics would also be added to the model to gain a more complete understanding of impacts related to resilience, for example, MEP scan rate. Once complete, the model could be used to analyze the effectiveness of mitigation strategies representing some future state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessment of the High Flux Isotope Reactor Cybersecurity Initiative

Recent cyber-attacks on industrial control systems, and inadvertent exposure of nuclear plant systems to cyber-exploits underscore the need for plant operators to adopt and deploy cyber-security defense solutions made for industrial control systems. Of increasing concern is the fact that international cyber hackers are beginning to target critical infrastructure, and because these more modern controls systems depend on advanced use of digital systems, they are more vulnerable than ever before to cyber-attacks. Traditional cyber defense strategies and products that have been available for decades are tailored for use on IT or corporate networks but can cause interruptions and catastrophic damage when deployed on industrial control system networks. The Department of Energy (DOE) Office of Nuclear Energy established the Gateway for Accelerated Innovation in Nuclear (GAIN) program to provide private companies pursuing innovative nuclear energy technologies with access to the technical support necessary to move toward commercialization. One of these GAIN small business vouchers was awarded to Dragos, Inc. to enable collaboration with Oak Ridge National Laboratory (ORNL) to evaluate the Dragos Platform on a production nuclear reactor test bed, hence laying the path for future commercial adoption. The vision was to provide a guide for industrial operators on implementing an industrial monitoring solution and to show how these solutions can be deployed without causing safety and reliability issues. This report documents the results of the collaboration between ORNL and Dragos, Inc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hybrid quantum-classical approach for coupled-cluster Green's function theory

The three key elements of a quantum simulation are state preparation, time evolution, and measurement. While the complexity scaling of time evolution and measurements are well known, many state preparation methods are strongly system-dependent and require prior knowledge of the system's eigenvalue spectrum. Here, we report on a quantum-classical implementation of the coupled-cluster Green's function (CCGF) method, which replaces explicit ground state preparation with the task of applying unitary operators to a simple product state. While our approach is broadly applicable to many models, we demonstrate it here for the Anderson impurity model (AIM). The method requires a number of T gates that grows as O ( N 5 ) per time step to calculate the impurity Green's function in the time domain, where N is the total number of energy levels in the AIM. Since the number of T gates is analogous to the computational time complexity of a classical simulation, we achieve an order of magnitude improvement over a classical CCGF calculation of the same order, which requires O ( N 6 ) computational resources per time step.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysing a multi‐stage cyber threat and its impact on the power system

Abstract Electric power systems are composed of physical and cyber sub‐systems. The sub‐systems depend on each other. If the cyber sub‐system is compromised by a cyber threat, what is the impact on the physical system? This paper presents a case study that shows the steps of a multi‐stage cyber threat involving a database injection attack, and what happens to the power system if this threat is not detected in its early stages. The threat first affects one utility but it can spread to the balancing authority, which is responsible for keeping the voltage and frequency stable in the power grid. During the cyber threat, the authors also show defence tools, such as a cyber‐physical data fusion tool that displays and analyses power and cyber telemetry.

Al Homoud, Leen [Texas A&amp,M University College ↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report: FY19-FY22)

This is the final technical report for the FY19-FY21 research program "R&D to Ensure a Scientific Basis for Qualification Tests and Standards." This research was performed because project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. This program advances PV module reliability of commercial products through identification of reliability needs, characterization that provides scientific understanding of targeted degradation mechanisms, and translation of those data into practical and predictive test protocols and standards. This report describes program scope, results, milestones, and accomplishments over the three-year period of performance.

14 SOLAR ENERGY↗