Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Monitoring and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Grid Modernization of Cooperatives and Municipal Utilities via Breakthrough System Monitoring, Control and Optimization

Develop and validate new grid visualization, control paradigms, and business models for Holy Cross Energy (HCE) through integration of grid-friendly intelligent DER assets. Project Impact: Enable cooperatives and municipally-owned utilities to fully leverage DERs as part of their strategies for providing safe, reliable, and affordable electric services. Meets U.S. Department of Energy (DOE) grid modernization goal of achieving at least 10% active devices to provide grid flexibility by 2035.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Modernization of Cooperatives and Municipal Utilities via Breakthrough System Monitoring, Control and Optimization (CRADA Final Report)

This project aims at developing and demonstrating successful implementation of breakthrough approaches in real-time data visualization as well as real-time distributed DER control and optimization to provide ample benefits to both utilities and end users. The National Renewable Energy Laboratory (NREL), Holy Cross Energy (HCE), National Rural Electric Cooperative Association (NRECA) and Survalent are collaborating to enable Cooperative and Municipal utilities to fully leverage DERs as part of their strategies for providing safe, reliable, and affordable electric services to their customers and help meet DOE Grid modernization goal of achieving at least 10% active devices to provide grid flexibility by 2035. This project will use novel real-time control algorithms and approaches for distributed control recently developed under DOE-funded projects, using the date from the Survalent’s basic SCADA engine, GIS and AMI engines deployed at HCE combined with NRECA’s globally-used MultiSpeak(R) software interoperability specification for seamless and real-time communications between electric utility enterprise software to embrace DER as part of their strategies for providing safe, reliable and affordable electric service to their customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Validation of a Resilient Monitoring and Control System

Complex, high performance, engineering systems have to be closely monitored and controlled to ensure safe operation and protect public from potential hazards. One of the main challenges in designing monitoring and control algorithms for these systems is that sensors and actuators may be malfunctioning due to malicious or natural causes. To address this challenge, this paper addresses a resilient monitoring and control (ReMAC) system by expanding previously developed resilient condition assessment monitoring systems and Kalman filter-based diagnostic methods and integrating them with a supervisory controller developed here. While the monitoring and diagnostic algorithms assess plant cyber and physical health conditions, the supervisory controller selects, from a set of candidates, the best controller based on the current plant health assessments. To experimentally demonstrate its enhanced performance, the developed ReMAC system is then used for monitoring and control of a chemical reactor with a water cooling system in a hardware-in-the-loop setting, where the reactor is computer simulated and the water cooling system is implemented by a machine condition monitoring testbed at Idaho National Laboratory. Results show that the ReMAC system is able to make correct plant health assessments despite sensor malfunctioning due to cyber attacks and make decisions that achieve best control actions despite possible actuator malfunctioning. Monitoring challenges caused by mismatches between assumed system component models and actual measurements are also identified for future work.

97 MATHEMATICS AND COMPUTING↗

Cybersecurity of Wide Area Monitoring, Protection and Control Systems for HVDC Applications

The flexibility provided by High Voltage Direct Current (HVDC) systems can be further extended by Wide Area Monitoring, Protection, and Control (WAMAPC) systems. WAMPAC systems enable many HVDC applications and, on the other hand, inevitably introduce cybersecurity concerns that need to be addressed. In this work, a security domain layer and decision framework is reported to detect and mitigate the impact of false data injection (FDI) attacks targeting HVDC stations. Specifically, a rule-based cyber-attack detection method is introduced and implemented on Raspberry Pi and tested on the real-time HVDC simulation facility on the real-time digital simulator (RTDS) platform at ABB U.S. Corporate Research Center.

cybersecurity↗

Control system backplane monitoring with FPGA

Described herein are various technologies for monitoring the backplane of a control system and detecting modifications of the control system (e.g., removal of modules, firmware updates, etc.). A monitoring device includes a field programmable gate array (FPGA), and is connected to the backplane of the control system. The monitoring device receives signals, by way of the backplane, that are communicated among modules connected to the backplane. The monitoring device detects a modification to the control system based upon the received signals.

97 MATHEMATICS AND COMPUTING↗

System and method for in situ volumetric sensing of 3D cure state of resin being used in an additive manufacturing system

An in situ cure monitoring control system for use with a volumetric three dimensional (3D) printing system, wherein the volumetric 3D system includes a container defining a build volume, the container includes a photocurable resist used for making a 3D part, and the resist is responsive to an optical curing beam from a light source, which is controlled by a controller, and which is passed through the resist. The cure monitoring control system includes an optical signal source which generates optical signals having a wavelength selected in relation to a characteristic of the resist, and directed to pass through the build volume. A detector detects the optical signals and generates output signals in accordance therewith. Software monitors the output signals and uses the output signals to modify the curing beam to help optimize curing of the resist.

Panas, Robert Matthew↗

GEECS (Generalized Equipment and Experiment Control System)

GEECS (Generalized Equipment and Experiment Control System) monitors and controls equipment distributed across a network, performs experiments by scanning input variables, and collects and stores various types of data synchronously from devices. Examples of devices include cameras, motors and pressure gauges. GEEKS is based upon LabView graphical object oriented programming (GOOP), allowing for a modular and scalable framework. Data is published for subscription of an arbitrary number of variables over TCP. A secondary framework allows easy development of graphical user interfaces for a combined control of any available devices on the control system without the need of programming knowledge. This allows for rapid integration of GEECS into a wide variety of systems. A database interface provides for devise and process configuration while allowing the user to save large quantities of data to local or network drives.

Gonsalves, Anthony↗

Loss Control and Monitoring Systems for NSLS-Ii

The tunnel shielding design for the NSLS-II will provide adequate protection for beam losses up to 13nC/min or 100% of the maximum top-off injection beam current to be lost in the two periods of the ring around the injection point, while the remainder of the ring is shielded for lower losses of 1.1nC/min or ≤10% of the maximum top-off injected beam current. Additional local shielding of potential loss points in the injection region (e.g. injection septum) will be used to increase the level of loss allowed at these location during 1 Hz injection (i.e. nonTop-off injection). This shielding design will require a system to insure that beam losses don’t exceed these levels for a period of time that could potentially cause levels of radiation outside the shield walls to exceed administrative levels. This Loss Control and Monitoring (LCM) system will provide a level of loss control, loss location measurements and provide alarm indication of the level of beam power losses along the beam path from the source (e-gun, linac) thru the injection system and the storage ring. This system will consist of collimators and scrapers that will provide limits to the beam miss-steering and control the loss points of the charge, and monitors that will measure the average beam current losses along the beam path and alarm when this beam power loss exceeds the level set by the shielding specifications or administrative levels. This will require some new ideas in beam loss detection capability and collimation. The system is not intended to trip interlocks (dumping beam or terminating injection) but only to alarm that higher than normal beam power losses are observed and report where it is occurring. If the alarms conditions are not corrected within a time limit, top-off injection could be slowed down, thereby reducing the beam loss and the radiation it may be producing.

36 MATERIALS SCIENCE↗

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NSLS-II Beam Loss Control and Monitoring System

One of the most challenging issues for accelerator operations deals with why and where the beam was lost. This is a major concern for radiation protection at facilities with a large user base, since uncontrolled beam losses could result in high radiation levels to occupied areas. For NSLS-II the tunnel radiation shield wall has increased attenuation over two lattice cells after the injection region, to shield for the possibility of higher injection losses during injection. This raised the concern over exceeding the radiation exposure limits in the lesser shielded region, if similar losses could occur elsewhere. To address this issue a beam loss control system was designed to capture most beam losses in the more heavily shielded (injection) region. A beam loss monitor system was designed to verify the fraction of the beam lost in that region, in order to insure lower levels of exposure around the rest of the ring. The design of these beam loss control and monitoring systems and their operational experience are presented here.

43 PARTICLE ACCELERATORS↗

Applying Service-Oriented Architecture to Archiving Data in Control and Monitoring Systems

Current trends in the architecture of software systems focus our attention on building systems using a set of loosely coupled components, each providing a specific functionality known as service. It is not much different in control and monitoring systems, where a functionally distinct sub-system can be identified and independently designed, implemented, deployed and maintained. One functionality that renders itself perfectly to becoming a service is archiving the history of the system state. The design of such a service and our experience of using it are the topic of this article. The service is built with responsibility segregation in mind, therefore, it provides for reducing data processing on the data viewer side and separation of data access and modification operations. The service architecture and the details concerning its data store design are discussed. An implementation of a service client capable of archiving EPICS process variables (PV) and LabVIEW shared variables is presented. Data access tools, including a browser-based data viewer and a mobile viewer, are also presented.

Nogiec, J. M.↗

Tritium Breeding Blanket for a Commercial Fusion Power Plant - A System Engineering Assessment

The goal of developing a new source of electric power based on fusion has been pursued for decades. If successful, future fusion power plants will help meet growing world-wide demand for electric power. A key feature and selling point for fusion is that its fuel supply is widely distributed globally and virtually inexhaustible. Current world-wide research on fusion energy is focused on the deuterium-tritium (DT for short) fusion reaction since it will be the easiest to achieve in terms of the conditions (e.g., temperature, density and confinement time of the DT fuel) required to produce net energy. Over the past decades countless studies have examined various concepts for TBBs for both magnetic fusion energy (MFE) and inertial fusion energy (IFE). At this time, the key organizations involved are government sponsored research organizations world-wide. The near-term focus of the MFE community is on the development of TBB mock-ups to be tested on the ITER tokamak currently under construction in Caderache France. TBB concepts for IFE tend to be different from MFE primarily due to significantly different operating conditions and constraints. This report focuses on longer-term commercial power plants where the key stakeholders include: electric utilities, plant owner and operator, manufacturer, regulators, utility customers, and in-plant subsystems including the heat transfer and conversion systems, fuel processing system, plant safety systems, and the monitoring control systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Opdefender Network Monitoring And Control System

OpDefender is a new system designed to enhance the cyber security of control system networks. It accomplishes this by inspecting each network packet using a novel, patent-pending method that extends software defined networking into the application/ICS protocol layer. OpDefender consists of two key components: 1. Smart, “ICS-aware” network switches that analyze and filter network traffic in real time. 2. A network management human machine interface (HMI) that allows an operator to monitor and control network traffic in real time. The “ICS-aware” switches can serve as a drop-in replacement for typical network switches, or they can be used in conjunction with existing network switches. OpDefender is configured and controlled in real time via a custom-built, web-based HMI designed with the operator in mind.

Johnson, BriamE.↗

Wireless battery management control and monitoring system

A battery management system using a sensor inside of the battery that sensor enables monitoring and detection of various events in the battery and transmission of a signal from the sensor through the battery casing to a control and data acquisition module by wireless transmission. The detection of threshold events in the battery enables remedial action to be taken to avoid catastrophic events.

25 ENERGY STORAGE↗