Impact of GPS Signal Loss and Its Mitigation in Power System Synchronized Measurement Devices

With the aid of global positioning system (GPS), synchronized measurement devices (SMDs) are increasingly deployed across power systems to monitor the status of electric grids by providing accurate measurement data along with unified time stamps. Unfortunately, GPS receivers tend to lose signal lock when certain uncontrollable and unpredictable factors arise. In order to investigate the presence of GPS signal loss (GSL) issues on measurement devices, analysis is performed on historical data from both phasor data concentrators and FNET/GridEye servers. Meanwhile, the impact of GSL on field measurement accuracy has not been previously explored in depth. Through analysis and experimental tests, this paper discovers angle drift caused by GSL, which consequently leads to the total vector error exceeding the IEEE standard C37.118.1-2011. Furthermore, a compensation method is proposed to rectify the angle drift and laboratory experiments demonstrate that the proposed method does effectively reduce angle drift and mitigate the impact of GSL in SMDs.

47 OTHER INSTRUMENTATION↗

Pioneer Design of Non-contact Synchronized Measurement Devices Using Electric and Magnetic Field Sensors

Here, traditional synchrophasors rely on CTs and PTs physically connected to transmission lines or buses to acquire input signals for phasor measurement. However, it is challenging to install and maintain traditional phasor measurement units in some remote areas due to lack of facilities. Since transmission lines naturally generate alternating electrical and magnetic fields in the surrounding atmosphere, this paper presents two innovative designs for non-contact synchronized measurement devices (NCSMD), including an electric field sensor based non-contact SMD (E-NCSMD) and a magnetic field sensor based non-contact SMD (M-NCSMD). Compared with conventional synchrophasors, E-NCSMD and M-NCSMD are much more flexible to be deployed and have much lower costs, making E-NCSMDs and M-NCSMD highly accessible and useful for a wide array of phasor measurement applications. Laboratory and field experiment results verified the effectiveness of the designs of both E-NCSMD and M-NCSMD.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precise ROCOF estimation algorithm for low inertia power grids

The precise estimation of Rate Of Change Of Frequencies (ROCOFs) in a generation trip event can be helpful on power system inertia estimation, fast system response, and accurate event capturing. However, the ROCOF estimations from the existing Synchronized Measurement Devices (SMDs) are usually simply calculated by the finite difference between two adjacent frequency measurement points. The ineluctable noises, disturbances, and spikes from real-world frequency measurements can bring large dynamics to the ROCOF estimation and thus can result in an inaccurate estimation of the initial ROCOF. This issue becomes more serious when the target power grid has low inertia, and a large amount of distributed energy sources are deployed. To address this issue, a precise ROCOF estimation algorithm is designed based on least square method with flexible window size. In addition, a median filter is also designed and applied on the frequency measurements before using the proposed algorithm. The window size and thresholds in the proposed algorithm are determined with historical event data analysis. The proposed algorithm is deployed in a low cost, flexible, and distribution level universal grid analyzer (UGA) platform. In conclusion, multiple experiments are conducted in both a laboratory and the Hawaiian Islands to verify the effectiveness of the proposed algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Synchrophasor-based Application for Potential Distributed Energy Resources Management: Key Technology, Challenge and Vision

With an increasing number of distributed energy resources (DERs) integrating into the power system, the power grid is becoming more complex and uncertain. Owing to most of DERs are through grid-connected converters to integrate into the power system, the intermittent nature and resource-depended characteristic of the DERs are challenging their monitoring and control. Conventional synchronized measurement devices (SMDs) may be difficult to provide qualified data for DERs management for its accuracy and reporting-rate limitation. The monitoring systems developed basing on SMDs may be insufficient for depicting detailed dynamic manifestations of power systems with a high proportion integration of DERs. This paper shares some advanced synchrophasor-based applications developed in FNET/GridEye, which have a broad prospect for assisting system operator on the control and integration of the DERs.

Wang, Weikang↗

Synchronized Wireless Measurement of High-Voltage Power System Frequency Using Mobile Embedded Systems

This paper focuses on synchronized wireless measurement of high-voltage (HV) power system frequency using mobile embedded systems (MESs) integrated with a wireless electric field sensor (WEFS). Unlike traditional synchronized frequency measurement devices, which rely on potential transformers and current transformers physically connected to system elements, a WEFS is used to realize wireless signal acquisition in the vicinity of any HV apparatus. The MES performs real-time frequency estimation using a recursive discrete Fourier transform based algorithm. Network time protocol (NTP) is used for time synchronization, increasing the system flexibility by eliminating global positioning system reliance. An NTP-based synchronized sampling control method is proposed and implemented in MES to compensate the sampling time error caused by local time drift and division residue. The proposed system has the advantages of portability and lower cost, making it highly accessible and useful for a wide array of synchronized frequency measurement applications. Experiment results verify the accuracy and effectiveness of the proposed system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Alignment Method for Synchronized Phase Angle Measurement With Presence of Practical Time Shift

Synchronized Phase Angle Measurements (SPAMs) are widely used in power systems in the applications of situational awareness. However, the practical time shifts can lead to unexpected angle differences among Phasor Measurement Units (PMUs) manufactured from various vendors. Moreover, since most of PMUs calculate phase angle via Discrete Fourier Transform based approaches, this issue becomes even worse under the off-nominal frequency condition. To mitigate the impact of practical timing shift, this letter presents a fast method to rectify the SPAM for appropriate alignment. To verify the performance of the proposed method, laboratory and field tests have been conducted by implementing the method in PMUs and phasor data concentrators, respectively. The results demonstrate that the standard deviations of the phase angle differences have significantly decreased to 0.1$^{\circ }$ order with the adoption of the proposed method.

42 ENGINEERING↗

Synchrophasor measurement method for power systems

A synchrophasor measurement method for a device configured to take synchronized measurements in a power system is provided. The synchrophasor measurement method includes receiving global positioning system (GPS)-synchronized samples of a signal sensed by the device from the power system; determining a level of distortion of the signal; selecting, based on the level of distortion, a computation method, the computation method being one of an improved zero-crossing (IZC) method and an enhanced phase-lock-loop (EPLL) method; performing the selected computation method to determine at least one parameter of the signal at a reporting frequency, which is at least twice a line frequency of the power system; and outputting, at the reporting frequency, the at least one parameter to an operator of the power system to allow the operator to perform at least one of a monitoring and a controlling of at least one element of the power system.

Yao, Wenxuan↗

Performance Testing and Assessment of Protection Scheme Using Real-Time Hardware-in-the-Loop and IEC 61850 Standard

The main challenge of the microgrid is to design a suitable protection scheme due to the complexity of the architecture of the microgrid. The importance of the proposed protection technique is threefold. First, it presents a co-simulation platform to integrate between a simulated model on power system computer aided design (PSCAD)/real time digital simulator computer aided design (RSCAD) software’s and physical devices schweitzer engineering laboratories (SEL) 421-7 relays to protect the microgrid that includes different resources connected based on inverter interface. Second, it presents a comprehensive hardware/software setup to test the protective relays in a closed loop system and shows how to configure the protective relay’s International Electrotechnical Commission 61850 communications. Third, IEEE 1588 standard is used to provide sub nanoseconds latency between the simulated model that emulated on real time digital simulator (RTDS) and the external devices. Also, the measurement signals are synchronized between RTDS and the external devices using giga-transceiver synchronization card (GTSYNC) interface card and SEL-2488 satellite-synchronized network clock. The results showed that the co-simulation infrastructure introduces a highly dependable design, analysis, and testing environment for cyber and physical data flow in the system. Besides that, the voltages at ac/dc sides and frequency at fault condition were maintained due to the energy storage device contributions at different modes of operation.

42 ENGINEERING↗

Synchronized Waveforms – A Frontier of Data-Based Power System and Apparatus Monitoring, Protection, and Control

Voltage and current waveforms contain the most authentic and granular information on the behaviors of power systems. In recent years, it has become possible to synchronize waveform data measured from different locations. Thus large-scale coordinated analyses of multiple waveforms over a wide area are within our reach. This development could unleash a set of new concepts, strategies, and tools for monitoring, protecting, and controlling power systems and apparatuses. This paper presents an in-depth review and analysis of the advancements in synchronized waveform data, including measurement devices, data characteristics, use cases, and comparisons with synchrophasor data. Based on the findings, five strategies are proposed to discover and develop synchronized waveform based applications over multiple application areas. The paper also presents three complementary measurement platforms and two data screening algorithms for application implementation. It further discusses committee activities and standard developments useful to explore the full potential of the data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rapid Impedance Spectrum Measurements for State-of-Health Assessment of Energy Storage Devices

Harmonic compensated synchronous detection (HCSD) is a technique that can be used to measure wideband impedance spectra within seconds based on an input sum-of-sines signal having a frequency spread separated by harmonics. The battery (or other energy storage device) is excited with a sum-of-sines current signal that has a duration of at least one period of the lowest frequency. The voltage response is then captured and synchronously detected at each frequency of interest to determine the impedance spectra. This technique was successfully simulated using a simplified battery model and then verified with commercially available Sanyo lithium-ion cells. Simulations revealed the presence of a start-up transient effect when only one period of the lowest frequency is included in the excitation signal. This transient effect appears to only influence the low-frequency impedance measurements and can be reduced when a longer input signal is used. Furthermore, lithium-ion cell testing has indicated that the transient effect does not seem to impact the charge transfer resistance in the mid-frequency region. The degradation rates for the charge transfer resistance measured from the HCSD technique were very similar to the changes observed from standardized impedance spectroscopy methods. Results from these studies, therefore, indicate that HCSD is a viable, rapid alternative approach to acquiring impedance spectra.

25 ENERGY STORAGE↗

Practical Event Location Estimation Algorithm for Power Transmission System Based on Triangulation and Oscillation Intensity

Event location in power systems is quite essential information for system operators to enhance control-room situational awareness capability. Therefore, it is of great importance to develop an event location estimation algorithm for transmission systems with high accuracy. With the development of wide-area measurement system (WAMS) such as FNET/GridEye, and the synchrophasor measurement devices (SMDs) such as frequency disturbance recorders (FDRs), the synchronous measurement data including frequency, voltage amplitude and phase angle can be collected and used for event location estimation. First, the phase angle and rate of change of frequency (RoCoF) trajectories are respectively used for determining two sets of wave arrival time associated with each FDR. Then, a convolutional neural network (CNN) is utilized to determine the wave arrival order to select the more suitable set of wave arrival times for a given case and to perform corresponding modifications. Next, the oscillation intensity associated with each FDR is determined based on phase angle trajectories in the center of inertia (COI) coordinate system. Finally, the multiple criteria for event location estimation are represented. In conclusion, case studies and comparisons between the proposed and previous algorithms using actual and confirmed cases in U.S. power systems are performed to demonstrate the effectiveness and improvement of the proposed algorithm in practical applications.

frequency disturbance recorder (FDR)↗

Synchronized circuit improves accuracy of fluid transfer measurements

Shut-off valve at the destination of a transferred fluid, improves the accuracy of measurements determining the quantity of liquid transferred from a storage source to a remote location. By synchronizing this valve with the measuring device /totalizer/, the inaccuracies resulting from unfilled transfer lines can be reduced.

Vendl, C. J.↗

1 ns time to digital converters for the KM3NeT data readout system

The KM3NeT collaboration aims at the construction of a multi-km3 high-energy neutrino telescope in the Mediterranean Sea consisting of thousands of glass spheres (nodes), each of them containing 31 photomultiplier (PMT) of small photocathode area. The readout and data acquisition system of KM3NeT has to collect, treat and send to shore, in an economic way, the enormous amount of data produced by the photomultipliers. For this purpose, 31 high-resolution time-interval measuring channels are implemented on the Field-Programmable Gate Arrays (FPGA) based on Time to Digital Converter (TDC). TDC are very common devices in particles physics experiments. Architectures with low resources occupancy are desirable allowing the implementation of other instrumentation, communication and synchronization systems on the same device. The required resolution to measure both, time of flight and timestamp must be 1 ns. A 4-Oversampling technique with two high frequency clocks is used to achieve this resolution. The proposed TDC firmware is developed using very few resources in Xilinx Kintex-7.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-based irradiation apparatus and method to measure the functional dose-rate response of semiconductor devices

A broad-beam laser irradiation apparatus can measure the parametric or functional response of a semiconductor device to exposure to dose-rate equivalent infrared laser light. Comparisons of dose-rate response from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems can determine if aging has affected the device's overall functionality. The dependence of these changes on equivalent dose-rate pulse intensity and/or duration can be measured with the apparatus. The synchronized introduction of external electrical transients into the device under test can be used to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure while exposing the device to dose-rate equivalent infrared laser light.

47 OTHER INSTRUMENTATION↗

Synchronized Stress-strain Measurements in Dynamic Loading at High Pressure using D-DIA

A new data collection protocol for forced oscillation experiments using a multianvil high pressure device is reported. We derive the stress of the sample at high pressure and temperature from synchrotron x-ray diffraction that is synchronized with sample strain measurements from x-ray radiographs. This method yields stress directly from the sample rather than a stress proxy. Furthermore, the diffraction pattern yields useful information concerning time evolution of structurally related phenomena. Here we illustrate some of these possibilities with high pressure experimental data.

99 GENERAL AND MISCELLANEOUS↗

Interferometric system for precision imaging of vibrating structures

An optical profiler is modified in a way which allows it to image a MEMS device at various points during the movement of the MEMS device. The light source is synchronized with a desired movement of the MEMS device. The light source produces pulse at each synchronization period. During each pulse, an interferometric measurement is carried out. So long as the pulse is short enough such that the device does not move significantly, a detection of the position of the device can be accurately obtained.

Gutierrez, Roman C.↗

Use of a synchronization card for XMCD measurements at the XMaS Beamline

X-ray Magnetic Circular Dichroism (XMCD) spectra from a 5 {mu}m polycrystalline Gd foil were measured in transmission across the Gd L{sub 2,3} edges using the Multipurpose Unit for Synchronisation, Sequencing and Triggering (MUSST) card developed at the European Synchrotron Radiation Facility (ESRF). The circularly polarized x-rays were produced by a diamond phase-plate and their helicity was rapidly reversed through the use of a piezo driven device. The signal measured for each helicity was recorded by the MUSST card synchronized to the helicity reversal. The results are compared to those obtained using an analogue lock-in technique.

43 PARTICLE ACCELERATORS↗

Distributed Dynamic State Estimator, Generator Parameter Estimation and Stability Monitoring Demonstration

This is the final report for this project that was performed in the period: October1, 2009 to June 30, 2013. In this project, a fully distributed high-fidelity dynamic state estimator (DSE) that continuously tracks the real time dynamic model of a wide area system with update rates better than 60 times per second is achieved. The proposed technology is based on GPS-synchronized measurements but also utilizes data from all available Intelligent Electronic Devices in the system (numerical relays, digital fault recorders, digital meters, etc.). The distributed state estimator provides the real time model of the system not only the voltage phasors. The proposed system provides the infrastructure for a variety of applications and two very important applications (a) a high fidelity generating unit parameters estimation and (b) an energy function based transient stability monitoring of a wide area electric power system with predictive capability. Also the dynamic distributed state estimation results are stored (the storage scheme includes data and coincidental model) enabling an automatic reconstruction and “play back” of a system wide disturbance. This approach enables complete play back capability with fidelity equal to that of real time with the advantage of “playing back” at a user selected speed. The proposed technologies were developed and tested in the lab during the first 18 months of the project and then demonstrated on two actual systems, the USVI Water and Power Administration system and the New York Power Authority’s Blenheim-Gilboa pumped hydro plant in the last 18 months of the project. The four main thrusts of this project, mentioned above, are extremely important to the industry. The DSE with the achieved update rates (more than 60 times per second) provides a superior solution to the “grid visibility” question. The generator parameter identification method fills an important and practical need of the industry. The “energy function” based transient stability monitoring opens up new ways to protect the power grid, better manage disturbances, confine their impact and in general improve the reliability and security of the system. Finally, as a by-product of the proposed research project, the developed system is able to “play back” disturbances by a click of a mouse. The importance of this by-product is evident by considering the tremendous effort exerted after the August 2003 blackout to piece together all the disturbance recordings, align them and recreate the sequence of events. This project has moved the state of art from fault recording by individual devices to system wide disturbance recording with “play back” capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗