Results for “Surface Analysis”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Synthesis, characterization and crystal structure determination of Mn (II) ion based 1D polymer constructed from 2, 2′ bipyridyl and azide group, its thermal stability, magnetic properties and Hirshfeld surface analysis
The 1-D polymeric complex (I) is having formula [Mn(2,2′-BP).(N{sub 3}){sub 2}]{sub n}, which has been crystallized in distilled water and characterized by elemental analyses, FT-IR spectrum, powder X-ray diffraction analyses and single-crystal diffraction analysis. This polymer possesses 1D helical chains or coils where Mn–azide–Mn forms the base of the coil which is alternatively garlanded by rigid bi-pyridine rings, where coordinates are in anti-fashion. The Mn (II) ions in the repeating units are linked by two end-on azide groups which extend through the two end-to-end azide ligands to the next unit forming a 1-D polymeric chain. The present study suggests that the use of this rigid and neutral building block leads to give better arrangement of the polymeric motif with [010] chains in 2-c uninodal net. During investigation of strong or weak intermolecular interactions, X-ray diffraction analysis and Hirshfeld surface analysis give rise to comparable results but in Hirshfeld surface analysis, two-third times more results of close contacts are obtained. The fingerprint plots demonstrate that these weak non-bonding interactions are important for stabilizing the crystal packing. Magnetic properties of the complex (I) were analyzed on the basis of an alternating ferro- and antiferromagnetic Heisenberg chain of Mn (II) ions. The J-exchange parameters found are J{sub 1}=64.3 K (45.3 cm{sup −1}), and J{sub 2}=−75.7 K (−53.3 cm{sup −1}). Magnetic properties are discussed in comparison with those of other similar molecular magnets of [Mn(L–L)(N{sub 3}){sub 2}]{sub n} type. - - Highlights: • Synthesized 1-D polymeric complex of Mn (II) ions with 2, 2′ bipyridyl and azide group. • X-ray data of complex (I) is in a good agreement with TGA and other spectroscopic techniques. • DFT calculations were done and compared with the parameter of experimental and theoretical data. • Intermolecular interactions calculated by Hirshfeld surface analysis compared with X-ray data.
Application of Surface Analysis Methods to Nanomaterials: Summaryof ISO/TC 201 Technical Report: ISO 14187:2011 -Surface Chemical Analysis- Characterization of Nanomaterials
ISO Technical Report (TR) 14187 provides an introduction to (and examples of) the information that can be obtained about nanostructured materials using surface-analysis tools. In addition, both general issues and challenges associated with characterising nanostructured materials and the specific opportunities and challenges associated with individual analytical methods are identified. As the size of objects or components of materials approaches a few nanometres, the distinctions among 'bulk', 'surface' and 'particle' analysis blur. This Technical Report focuses on issues specifically relevant to surface chemical analysis of nanostructured materials. The report considers a variety of analysis methods but focuses on techniques that are in the domain of ISO/TC 201 including Auger electron spectroscopy, X-ray photoelectron spectroscopy, secondary ion mass spectrometry, and scanning probe microscopy. Measurements of nanoparticle surface properties such as surface potential that are often made in a solution are not discussed.
Importance of Sample Handling and Preparation for Surface Analysis: A Summary of ISO Standard 20579 Part 1, Documenting and Reporting the Handling of Specimens Prior to Analysis
Reliable and reproducible analysis of surfaces is critically dependent on how samples have been collected, handled, and prepared before analysis. Although there are important, well-established general guidelines to minimize unintended alteration of the surfaces to be analyzed, specific handling steps depend on the nature of the samples and information desired. Assessments of the validity and reliability of the results require adequate information about sampling, handling, and processing. ISO standard 20579 part 1 describes the information to be recorded and reported for samples that are prepared or submitted for surface analysis. This paper summarizes elements of the standard, which includes annexes that justify and inform the sample handling processes. Also included is a checklist of information that needs to be recorded and reported and an appendix containing an example of a form that might be used to report the information.
Advanced Multivariate Analysis Tools Applied to Surface Analysis.
No abstract prepared.
Direct Sampling and Analysis from Solid Phase Extraction Cards using an Automated Liquid Extraction Surface Analysis Nanoelectrospray Mass Spectrometry System
Direct liquid extraction based surface sampling, a technique previously demonstrated with continuous flow and autonomous pipette liquid microjunction surface sampling probes, has recently been implemented as the Liquid Extraction Surface Analysis (LESA) mode on the commercially available Advion NanoMate chip-based infusion nanoelectrospray ionization system. In the present paper, the LESA mode was applied to the analysis of 96-well format custom solid phase extraction (SPE) cards, with each well consisting of either a 1 or 2 mm diameter monolithic hydrophobic stationary phase. These substrate wells were conditioned, loaded with either single or multi-component aqueous mixtures, and read out using the LESA mode of a TriVersa NanoMate or a Nanomate 100 coupled to an ABI/Sciex 4000QTRAPTM hybrid triple quadrupole/linear ion trap mass spectrometer and a Thermo LTQ XL linear ion trap mass spectrometer. Extraction conditions, including extraction/nanoESI solvent composition, volume, and dwell times, were optimized in the analysis of targeted compounds. Limit of detection and quantitation as well as analysis reproducibility figures of merit were measured. Calibration data was obtained for propranolol using a deuterated internal standard which demonstrated linearity and reproducibility. A 10x increase in signal and cleanup of micromolar Angiotensin II from a concentrated salt solution was demonstrated. Additionally, a multicomponent herbicide mixture at ppb concentration levels was analyzed using MS3 spectra for compound identification in the presence of isobaric interferences.
Dual analyzer system for surface analysis dedicated for angle-resolved photoelectron spectroscopy at liquid surfaces and interfaces
The investigation of liquid surfaces and interfaces with the powerful toolbox of ultra-high vacuum (UHV)-based surface science techniques generally has to overcome the issue of liquid evaporation within the vacuum system. In the last decade, however, new classes of liquids with negligible vapor pressure at room temperature—in particular, ionic liquids (ILs)—have emerged for surface science studies. It has been demonstrated that particularly angle-resolved X-ray Photoelectron Spectroscopy (ARXPS) allows for investigating phenomena that occur at gas-liquid and liquid-solid interfaces on the molecular level. The results are not only relevant for IL systems but also for liquids in general. In all of these previous ARXPS studies, the sample holder had to be tilted in order to change the polar detection angle of emitted photoelectrons, which restricted the liquid systems to very thin viscous IL films coating a flat solid support. We now report on the concept and realization of a new and unique laboratory “Dual Analyzer System for Surface Analysis (DASSA)” which enables fast ARXPS, UV photoelectron spectroscopy, imaging XPS, and low-energy ion scattering at the horizontal surface plane of macroscopically thick non-volatile liquid samples. It comprises a UHV chamber equipped with two electron analyzers mounted for simultaneous measurements in 0° and 80° emission relative to the surface normal. The performance of DASSA on a first macroscopic liquid system will be demonstrated.
Effects of Thiocyanate on Anodic Dissolution of Iron, Chromium, Nickel and Type 304 Stainless Steel. II. Surface Analysis by XPS
As proposed in Part I of this paper, the accelerating effect of thiocyanate on active dissolution of stainless steel in acid sulfate solution occurs by adsorption of sulfur on the steel surface, causing accelerated dissolution of chromium from the steel surface. Surface analysis (X-ray photoelectron spectroscopy) was performed on pure chromium and nickel, a high-purity Fe-20wt% Cr alloy and Type 430 and Type 304 stainless steel to test the proposed mechanism. Surface analysis of the Fe 20wt% Cr alloy and stainless steels (Types 430 and 304) confirmed that chromium enriched on the metal surface during anodic dissolution in thiocyanate-free solution and that the surface enrichment of chromium was smaller in thiocyanate-containing solution. Surface analysis also confirmed the formation of sulfide or adsorbed sulfur on the Fe-20wt% Cr alloy in thiocyanate-containing solution. Surface restructuring of sulfide-covered electrode (Type 304 stainless steel and nickel) was the possible reason why increased anodic current density was observed immediately following interruption of anodic polarization for periods of 5s to 120s.
Chapter 4.2 - Preparation of nanoparticles for surface analysis
A variety of methods used to prepare nano-objects for surface analysis are described along with information about when they might be best applied. Intrinsic properties of NPs that complicate their characterization and need to be considered when planning for surface or other analyses of NPs are identified, including challenges associated with reproducible synthesis and functionalization of the particles as well as their dynamic nature. Information about the sample preparation processes, along with analysis data, that need to be added to the collection of material provenance information is identified and examples of protocols that have been successfully used for preparation of nano-objects for surface analysis are included in an annex.
Introduction to Special Issue on Advances and Applications of Surface Analysis Methods
Abstract: Introduction to the special issue on surface analysis, providing thumbnail sketches of several popular techniques. A table gives the capabilities of each technique.
Synthesis, structural characterization, Hirshfeld surface analysis and spectroscopic studies of cadmium (II) chloride complex with 4-hydroxy-1-methylpiperidine
The chemical preparation, crystal structure, Hirshfeld surface analysis and spectroscopic characterization of the novel cadmium (II) 4-hydroxy-1-methylpiperidine complex, Cd{sub 4}Cl{sub 10}(C{sub 6}H{sub 14}NO){sub 2}·2H{sub 2}O, have been reported. The atomic arrangement can be described as built up by an anionic framework, formed by edge sharing CdCl{sub 6} and CdCl{sub 5}O octahedral linear chains spreading along the a-axis. These chains are interconnected by water molecules via O–H⋯Cl and O–H⋯O hydrogen bonds to form layers parallel to (011) plane. The organic cations are inserted between layers through C–H⋯Cl hydrogen bonds. Investigation of intermolecular interactions and crystal packing via Hirshfeld surface analysis reveals that the H{sub C}⋯Cl and H{sub C}⋯H{sub C} intermolecular interactions are the most abundant contacts of the organic cation in the crystal packing. The statistical analysis of crystal contacts reveals the driving forces in the packing formation. The {sup 13}C and {sup 15}N CP-MAS NMR spectra are in agreement with the X-ray structure. The vibrational absorption bands were identified by infrared spectroscopy. DFT calculations allowed the attribution of the NMR peaks and of the IR bands.
PHELIX Liner Surface Analysis
This report provides results for liner profilometry surface analysis at the sub-micron level.
Detailed surface analysis of incremental Centrifugal Barrel Polishing (CBP) and EP of single-crystal niobium samples.
Detailed surface analysis of incremental Centrifugal Barrel Polishing (CBP) and EP of single-crystal niobium samples. Ari Palczewski, Hui Tian, Olga Trofimova, Charles Reece Jefferson Lab, Newport News, VA 23606 We performed Centrifugal Barrel Polishing (CBP) on single crystal niobium samples housed in a stainless steel sample holder following a polishing recipe recently developed at FNAL [1]. We were able to obtain a mirror-like finish after the final stage of tumbling, although some defects and imbedded particles remain. Our presentation will discuss the initial results from the coupon study, including qualitative and quantitative analysis of the surface characteristics from each step in the CBP process, followed by HPR and well controlled incremental EP. These will include surface roughness, size and character of contaminants, surface crystal structure, and overall finish. We will discuss how the surface characteristics should guide the SRF community in exploiting or adapting the Fermi recipe; including why minimal subsequent EP is needed, and possible places for modification of the recipe to reduce polishing time. This work is authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. [1]CA Cooper, LD Cooley , ?Mirror Smooth Superconducting RF Cavities by Mechanical Polishing with Minimal Acid Use,? http://lss.fnal.gov/archive/2011/pub/fermilab-pub-11-032-td.pdf, (May 31, 2011)
1st MPEX Users Research Forum (MURF) summary report: specifications for the Surface Analysis Station (SAS)
The Material Plasma Exposure eXperiment (MPEX) Team has reached out to the community of potential users of the MPEX facility to assess the high-priority capabilities which should be considered for inclusion in the design of the MPEX Surface Analysis Station (SAS). This activity is being carried out during the “advanced conceptual design” period of MPEX, i.e. post Conceptual Design Review (CDR) but prior to Preliminary Design (PD), to respond to a recommendation by the U.S. D.O.E. following the CDR. The MPEX Team will summarize the community recommendations into a guidance document (i.e. this report), which will influence the Surface Analysis Station during the Preliminary Design phase of the project.
Surface analysis of mixed-conducting ferrite membranes by the conversion-electron Moessbauer spectroscopy
Conversion-electron Moessbauer spectroscopy analysis of iron surface states in the dense ceramic membranes made of {sup 57}Fe-enriched SrFe{sub 0.7}Al{sub 0.3}O{sub 3-{delta}} perovskite, shows no traces of reductive decomposition or carbide formation in the interfacial layers after operation under air/CH{sub 4} gradient at 1173 K, within the limits of experimental uncertainty. The predominant trivalent state of iron cations at the membrane permeate-side surface exposed to flowing dry methane provides evidence of the kinetic stabilization mechanism, which is only possible due to slow oxygen-exchange kinetics and enables long-term operation of the ferrite-based ceramic reactors for natural gas conversion. At the membrane feed-side surface exposed to air, the fractions of Fe{sup 4+} and Fe{sup 3+} are close to those in the powder equilibrated at atmospheric oxygen pressure, suggesting that the exchange limitations to oxygen transport are essentially localized at the partially reduced surface. - Graphical Abstract: Conversion-electron Moessbauer spectroscopy analysis of dense ceramic membranes made of {sup 57}Fe-enriched SrFe{sub 0.7}Al{sub 0.3}O{sub 3-{delta}} perovskite, shows no reductive decomposition in thin interfacial layers after testing under air/CH{sub 4} gradient, enabling stable operation of the ferrite-based ceramic reactors for partial oxidation of methane. Highlights: > Conversion-electron Moessbauer spectroscopy is used for mixed-conducting membranes. > No decomposition is detected in the membrane surface layers under air/CH{sub 4} gradient. > Due to kinetic stabilization, Fe{sup 3+} states prevail at the surface exposed to methane. > Transmission Moessbauer spectra show perovskite decomposition on equlibration in CH{sub 4}. > Ferrite-based ceramic reactors can stably operate under air/CH{sub 4} gradient.
Droplet Evaporation on Hot Micro-Structured Superhydrophobic Surfaces: Analysis of Evaporation from Droplet Cap and Base Surfaces
In this study, evaporation of sessile water droplets on hot micro-structured superhydrophobic surfaces is experimentally and theoretically investigated. Water droplets of 4 µL are placed on micro-pillared silicon substrates with the substrate temperature heated up to 120°C. A comprehensive thermal circuit model is developed to analyze the effects of substrate roughness and substrate temperature on the sessile droplet evaporation. For the first time, two components of heat and mass transfer, i.e., one from the droplet cap surface and the other from the droplet base surface, during droplet evaporation are distinguished and systematically studied. As such, the evaporation heat transfer rates from both the droplet cap surface and the interstitial liquid-vapor interface between micropillars at the droplet base are calculated in various conditions. For droplet evaporation on the heated substrates in the range of 40°C – 80°C, the predicted droplet cap temperature matches well with the experimental results. Furthermore, during the constant contact radius mode of droplet evaporation, the decrease of evaporation rate from the droplet base contributes most to the continuously decreasing overall evaporation heat transfer rate, whereas the decrease of evaporation rate from the droplet cap surface is dominant in the constant contact angle mode. The influence of internal fluid flow is considered for droplet evaporation on substrates heated above 100°C, and an effective thermal conductivity is adopted as a correction factor to account for the effect of convection heat transfer inside the droplet. Temperature differences between the droplet base and the substrate base are estimated to be about 2°C, 5°C, 8°C, 13°C and 18°C for droplet evaporation on substrates heated at 40°C, 60°C, 80°C, 100°C, and 120°C, respectively, elucidating the delayed or depressed boiling of water droplets on a heated rough surface due to evaporative cooling.
Surface Analysis and Hydrogen Permation Measurements for Super-Permeating Membrane Materials
In this report, we summarize preliminary surface characterization results for Nb surfaces, using low energy ion scattering, direct recoil spectrometry, and Auger electron spectroscopy. While most surface analysis tools cannot detect hydrogen, the low energy ion beam techniques described here are among the few techniques that are directly sensitive to it. For this study, we examined chemisorption using both molecular and atomic hydrogen (using an heated tungsten capillary to dissociate the hydrogen.) To complement these results, we have been performing ex-situ spectroscopic ellipsometry as a means of detecting the surface oxide.