The effect of preceding and following auditory stimuli on response times to visual stimuli
Human response time to visual stimulus preceding or following auditory stimulus as function of interstimulus interval
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Human response time to visual stimulus preceding or following auditory stimulus as function of interstimulus interval
An investigation has been made of anisotropic responses to contoured and noncontoured stimuli to obtain an insight into the way these stimuli are processed. For this purpose, eight subjects judged the alignment of minimally contoured (3 dot) and contoured (line) stimuli. Stimuli, presented to each eye separately, vertically subtended either 8 or 32 deg visual angle and were located 10 deg left, center, or 10 deg right in the visual field. Location-dependent deviations from physical straightness were larger for dot stimuli than for lines. The results were the same for the two eyes. In a second experiment, subjects judged the alignment of stimuli composed of different densities of dots. Apparent straightness for these stimuli was the same as for lines. The results are discussed in terms of alternative mechanisms for analysis of contoured and minimally contoured stimuli.
Abstract Spiering, BA, Clark, BC, Schoenfeld, BJ, Foulis, SA, and Pasiakos, SM. Maximizing strength: the stimuli and mediators of strength gains and their application to training and rehabilitation. J Strength Cond Res 37(4): 919–929, 2023—Traditional heavy resistance exercise (RE) training increases maximal strength, a valuable adaptation in many situations. That stated, some populations seek new opportunities for pushing the upper limits of strength gains (e.g., athletes and military personnel). Alternatively, other populations strive to increase or maintain strength but cannot perform heavy RE (e.g., during at-home exercise, during deployment, or after injury or illness). Therefore, the purpose of this narrative review is to (a) identify the known stimuli that trigger gains in strength; (b) identify the known factors that mediate the long-term effectiveness of these stimuli; (c) discuss (and in some cases, speculate on) potential opportunities for maximizing strength gains beyond current limits; and (d) discuss practical applications for increasing or maintaining strength when traditional heavy RE cannot be performed. First, by conceptually deconstructing traditional heavy RE, we identify that strength gains are stimulated through a sequence of events, namely: giving maximal mental effort, leading to maximal neural activation of muscle to produce forceful contractions, involving lifting and lowering movements, training through a full range of motion, and (potentially) inducing muscular metabolic stress. Second, we identify factors that mediate the long-term effectiveness of these RE stimuli, namely: optimizing the dose of RE within a session, beginning each set of RE in a minimally fatigued state, optimizing recovery between training sessions, and (potentially) periodizing the training stimulus over time. Equipped with these insights, we identify potential opportunities for further maximizing strength gains. Finally, we identify opportunities for increasing or maintaining strength when traditional heavy RE cannot be performed.
Recently, three dimensional acoustic display systems have been developed that synthesize virtual sound sources over headphones based on filtering by Head-Related Transfer Functions (HRTFs), the direction-dependent spectral changes caused primarily by the outer ears. Here, 11 inexperienced subjects judged the apparent spatial location of headphone-presented speech stimuli filtered with non-individualized HRTFs. About half of the subjects 'pulled' their judgements toward either the median or the lateral-vertical planes, and estimates were almost always elevated. Individual differences were pronounced for the distance judgements; 15 to 46 percent of stimuli were heard inside the head with the shortest estimates near the median plane. The results infer that most listeners can obtain useful azimuth information from speech stimuli filtered by nonindividualized RTFs. Measurements of localization error and reversal rates are comparable with a previous study that used broadband noise stimuli.
Micro- and nano-patterned surfaces offer precise control over morphology and chemical composition, enhancing the stability, durability, and functionality of coating materials. When combined with stimuli-responsive polymers, these surfaces gain dynamic adaptability, enabling reversible binding, reusable sensing, and selective molecular capture. Furthermore, while recent review articles have explored various aspects of stimuli-responsive materials, from hydrogel patterns for bioanalytical applications to shape-morphing hydrogels for soft robotics and sensors, a comprehensive review focused on the integration of smart polymers with micro- or nano-patterned interfaces remains absent. This review addresses key surface patterning techniques, including soft lithography, colloidal lithography, and polymer brush photolithography, as well as advances in surface-initiated polymerization methods, such as surface-initiated controlled radical polymerization (SI-CRP). In addition, we discuss recent progress in integrating stimuli-responsive polymers with patterned surfaces to create advanced, functional materials.
Two male observers were administered a binocular visual response time task to small (45 min arc), flashed, photopic stimuli at four dominant wavelengths (632 nm red; 583 nm yellow; 526 nm green; 464 nm blue) imaged across the horizontal retinal meridian. The stimuli were imaged at 10 deg arc intervals from 80 deg left to 90 deg right of fixation. Testing followed either prior light adaptation or prior dark adaptation. Results indicated that mean response time (RT) varies with stimulus color. RT is faster to yellow than to blue and green and slowest to red. In general, mean RT was found to increase from fovea to periphery for all four colors, with the curve for red stimuli exhibiting the most rapid positive acceleration with increasing angular eccentricity from the fovea. The shape of the RT distribution across the retina was also found to depend upon the state of light or dark adaptation. The findings are related to previous RT research and are discussed in terms of optimizing the color and position of colored displays on instrument panels.
The present goal is to determine by the production of discrete lesions the parts of the hypothalamus and brainstem that are involved in serotonin-mediated increases in renin secretion. A variety of stimuli which act in different ways to increase renin stimuli were developed and standardized. The experiments with p-chloroamphetamine (PCA) demonstrated that there is a serotonergic pathway which projects from the dorsal raphe nuclei to the paraventricular nuclei and the vetromedial nuclei of the hypothalamus; that projection from paraventricular nuclei to the brainstem and spinal cord may be oxytocinergic; and that the pathway from the spinal cord to the renin secreting cells is sympathetic. The demonstration that paraventicular lesions lower circulating renin substrate is important because it raises the possibility that substrate secretion is under neural control, either via the pituitary or by direct neural pathways. The discovery that lesions of the ventromedial nuclei appear to abolish the increase in renin secretion produced by many different stimuli without affecting the concentration of renin substrate in the plasma makes the position of the hypothalamus in the regulation of fluid and electrolyte balance more prominent than previously suspected.
A program for automatic computer generation of novel nonverbal stimuli is described. The program, STIMGEN, allows menu-driven control over the type and appearance of stimuli. Data are presented in which two monkeys matched to sample with high accuracy using stimuli generated with STIMGEN. These data are interpreted to support the usefulness and value of automatic stimulus generation in a variety of applications.
Abstract Stimuli‐responsive photoluminescent (PL) materials have attracted considerable attention in recent years owing to their potential applications in anti‐counterfeiting, information encryption, and sensing. Further investigations of the transformation mechanism and potential applications of stimulus‐responsive PL materials are considerably important. In the current study, an organic–inorganic metal halide, C 9 H 15 N 3 SbCl 5 ([C 9 H 13 N 3 ] 2+ is a 1‐(2‐pyridyl) piperazine cation) is obtained, which exhibits a 0D structure withP‐1 space group. At room temperature, when excited by UV light, the C 9 H 15 N 3 SbCl 5 single crystals exhibit unimodal blue light emission at 405 nm, and grinding or hydrostatic pressure induces double‐peak emissions at 405 and 650 nm. Interestingly, double‐emission samples can be restored to single‐emission samples by short annealing or storage in air for 2 weeks, and this process is reversible. Luminescence response to mechanical stimuli can also be achieved in the presence of hydrochloric acid and water. Spectral analysis and the analysis of the microstructural changes revealed that the structural modifications of the inorganic group play a pivotal role in the response to the stimulus. Finally, a composite film device based on C 9 H 15 N 3 SbCl 5 is prepared to demonstrate the potential of these smart materials in anti‐counterfeiting and sensing applications.
Insulin secretory granule (ISG) maturation is a crucial aspect of insulin secretion and glucose homeostasis. The regulation of this maturation remains poorly understood, especially how secretory stimuli affect ISG maturity and subcellular localization. In this study, we used soft X-ray tomography (SXT) to quantitatively map ISG morphology, density, and location in single INS-1E and mouse pancreatic β cells under the effect of various secretory stimuli. We found that the activation of glucokinase (GK), gastric inhibitory polypeptide receptor (GIPR), glucagon-like peptide-1 receptor (GLP-1R), and G protein-coupled receptor 40 (GPR40) promotes ISG maturation. Each stimulus induces unique structural remodeling in ISGs, by altering size and density, depending on the specific signaling cascades activated. These distinct ISG subpopulations mobilize and redistribute in the cell, altering the overall cellular structural organization. Our results provide insight into how current diabetes and obesity therapies impact ISG maturation and may inform the development of future treatments that target maturation specifically.
In this work, a comprehensive study focusing on the influence of the sequence charge pattern on the secondary structure preferences of annealed polyampholytes and their responsiveness to external stimuli is presented. Two sequences are designed composed entirely of ionizable amino acids (charge fraction f=1), and an equal number of positive and negative charges (f + =f - =0.5) with distinct charge-patterns consisting of lysine and glutamic acid monomers. The study reveals that the sequence charge pattern has a significant influence on the secondary structure preferences of polyampholytes at physiological pH. Furthermore, it shows that external stimuli such as pH, ionic strength and solvent dielectric constant can be used to modulate the secondary structure of the two designed sequences. The observed secondary structure transformations for the two sequences are also substantially different from those determined for uniformly charged polypeptides-homo-polypeptides under matching conditions.
Memristor devices fabricated using the chalcogenide Ge 2 Te 3 phase change thin films in a metal-insulator-metal structure are characterized using thermal and electrical stimuli in this study. Once the thermal and electrical stimuli are applied, cross-sectional transmission electron microscopy (TEM) and X-ray energy-dispersive spectroscopy (XEDS) analyses are performed to determine structural and compositional changes in the devices. Electrical measurements on these devices showed a need for increasing compliance current between cycles to initiate switching from low resistance state (LRS) to high resistance state (HRS). The measured resistance in HRS also exhibited a steady decrease with increase in the compliance current. High resolution TEM studies on devices in HRS showed the presence of residual crystalline phase at the top-electrode/dielectric interface, which may explain the observed dependence on compliance current. XEDS study revealed diffusion related processes at dielectric-electrode interface characterized, by the separation of Ge 2 Te 3 into Ge- and Te- enriched interfacial layers. This was also accompanied by spikes in O level at these regions. Furthermore, in-situ heating experiments on as-grown thin films revealed a deleterious effect of Ti adhesive layer, wherein the in-diffusion of Ti leads to further degradation of the dielectric layer. This experimental physics-based study shows that the large HRS/LRS ratio below the current compliance limit of 1 mA and the ability to control the HRS and LRS by varying the compliance current are attractive for memristor and neuromorphic computing applications.
Pigeon accelerated performance patterns as function of contiguity of brief visual stimuli and food reinforcement, noting pattern absence during stimuli omission
Peripheral visual response time was measured in seven dark adapted subjects to the onset of small (45' arc diam), brief (50 msec), colored (blue, yellow, green, red) and white stimuli imaged at 72 locations within their binocular field of view. The blue, yellow, and green stimuli were matched for brightness at about 2.6 sub log 10 units above their absolute light threshold, and they appeared at an unexpected time and location. These data were obtained to provide response time and no-response data for use in various design disciplines involving instrument panel layout. The results indicated that the retina possesses relatively concentric regions within each of which mean response time can be expected to be of approximately the same duration. These regions are centered near the fovea and extend farther horizontally than vertically. Mean foveal response time was fastest for yellow and slowest for blue. Three and one-half percent of the total 56,410 trials presented resulted in no-responses. Regardless of stimulus color, the lowest percentage of no-responses occurred within 30 deg arc from the fovea and the highest within 40 deg to 80 deg arc below the fovea.
This study examines the effect on human performance of adding Gaussian noise or disturbance to the stimuli in absolute judgment tasks involving both one- and two-dimensional stimuli. For each selected stimulus value (both an X-value and a Y-value were generated in the two-dimensional case), 10 values (or 10 pairs of values in the two-dimensional case) were generated from a zero-mean Gaussian variate, added to the selected stimulus value and then served as the coordinate values for the 10 points that were displayed sequentially on a CRT. The results show that human performance, in terms of the information transmitted and rms error as functions of stimulus uncertainty, was significantly reduced as the noise variance increased.
This paper presents a model for the perception of dynamic orientation resulting from stimuli which involve both the otoliths and the semicircular canals. The model was applied to several multisensory stimuli and its predictions evaluated. In all cases, the model predictions were in substantial agreement with the known illusions or with the relevant experimental data.
Simple onset response time (RT) experiments, previously shown to exhibit binocular summation effects for white stimuli along the horizontal meridian, were performed for red and green stimuli along 5 oblique meridians. Binocular RT was significantly shorter than monocular RT for a 45-min-diameter spot of red, green, or white light within eccentricities of about 50 deg from the fovea. Relatively large meridian differences were noted that appear to be due to the degree to which the images fall on corresponding retinal areas.
The set of experiments comprising the Spacelab 1ES201 package designed to investigate the human vestibular system and equilibratory function in weightlessness are described. The specific objectives of the experiments include: (1) the determination of the threshold of perception of linear oscillatory motion; (2) measurement of physiological and subjective responses to supra threshold, linear and angular motion stimuli; (3) study of the postural adjustments, eye movements, and illusions of attitude and motion evoked by optokinetic stimuli, (i.e., moving visual patterns) in order to assess visual/vestibular interactions; (4) examination of the effect of thermal stimulations of the vestibular apparatus to determine if the eye movements elicited by the 'caloric test' are used by a density gradient in the semicircular canal; and (5) investigation of the pathogenesis of space motion sickness by recording signs and symptoms during the course of vestibular stimulation and, specifically, when the test subject is exposed to sustained, linear oscillatory motion.