Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stilbene”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Anisotropic neutron response of trans-stilbene and impact on a handheld dual particle imager

Here this manuscript details measurements of the anisotropic light-output response of trans-stilbene, henceforth referred to as stilbene, along the three primary crystal planes and analyzes how this anisotropic response impacts neutron image reconstruction in a handheld dual particle imager (H2DPI). A prototype H2DPI composed of stilbene pillars (6 x 6 x 50 mm 3 ) coupled to silicon photomultipliers was built and is capable of imaging both fast neutrons and gamma rays from kilogram quantities of special nuclear material. Stilbene was chosen as the scintillating medium for the imager because of its pulse shape discrimination capability, time resolution and relatively high light output. A drawback to using stilbene, however, is the anisotropic response. A recoiling proton from a neutron elastic-scattering event in stilbene will yield different amounts of scintillation light depending on the direction of the recoiling proton with respect to the crystal lattice. This manuscript analyzes how this anisotropic response impacts neutron image reconstruction in 4π. The light output in the three primary crystal planes of stilbene were independently measured 6–7 times for proton recoil energies ranging from 0.5–5.0 MeV using a quasi-monoenergetic time-of-flight neutron source. The measured light-output data in the three crystal planes were fit with a semi-empirical function based on Birks’ formula. These fits were used to reconstruct the location of a 252 Cf source in front of the imager (0°, -0.8°), to the left of the imager (-90°, -0.8°) and directly above the imager (0°, 90°) to determine if it is necessary to apply the directionally-dependent response of stilbene to accurately reconstruct source locations. A bootstrapping technique was applied to the measured data sets to produce 1000 images composed of 2000 cone projections for each source location and each measured light-output curve. List-mode maximum likelihood expectation maximization was applied to each image; the highest pixel location and the full width at half maximum (FWHM) were then recorded. The average and standard deviations of these parameters were taken for each set of images. The maximum difference in the average azimuthal pixel location when varying between the appropriate and incorrect light-output curves for the source locations at (0°, -0.8°) and (-90°, -0.8°) were respectively found to be 1.85 ± 1.39° and 2.03 ± 1.78°. All other pixel locations and FWHMs were within a single standard deviation of uncertainty. Taken together, the anisotropic response of stilbene has negligible impact on the neutron image reconstruction capability of the H2DPI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of the light output anistropy in deuterated stilbene

Deuterated stilbene is an organic scintillator that is a desirable material for fast neutron spectroscopy using spectrum unfolding techniques without requiring time-of-flight information. Due to the crystal structure of the material, some anisotropy of the light output exists, which is dependent on the direction of heavy charged particle recoil relative to the crystal structure. The anisotropy of trans-stilbene (hereafter referred to as stilbene) has been well characterized in previous work, but for deuterated stilbene, the anisotropy has only been partially characterized along the a and b crystal axes, while the artificial c' axis, which shows the largest anisotropy in stilbene, has not been characterized until this publication. Here, in this work, two deuterated stilbene crystals were characterized with neutron energies up to 35 MeV at the Los Alamos Neutron Science Center. For one of the crystals, the response is characterized along the a, b, and c' axes. This characterization shows a distinct anisotropy along the axes in deuterated stilbene, which is very similar to that found in regular stilbene, such that the a axis is the brightest, while the b' and c' axes are approximately 3% and 20%–35% lower relative to the a axis.

36 MATERIALS SCIENCE↗

Nonadiabatic Dynamics of Photoexcited cis-Stilbene Using Ab Initio Multiple Spawning

The photochemistry of cis-stilbene proceeds through two pathways: cis-trans isomerization and ring closure to 4a,4b-dihydrophenanthrene (DHP). Despite serving for many decades as a model system for photoisomerization, the photodynamics of cis-stilbene is still not fully understood. In this work, we use ab initio multiple spawning on a SA-2-CASSCF(2,2) potential energy surface to simulate the nonadiabatic dynamics of isolated cis-stilbene. We find the cyclization (to DHP and cis-stilbene) and isomerization (to trans- and cis-stilbene) reaction coordinates to be orthogonal; branching between the two pathways is determined on the S1 excited state within 150 fs of photoexcitation. Furthermore ,trajectory basis functions (TBFs) undergoing cyclization decay rapidly to the ground state in 250 fs, while TBFs moving along the isomerization coordinate remain on the excited state longer, with the majority decaying between 300 and 500 fs. We observe three avoided crossing regions in the dynamics: two along the isomerization coordinate (displaying pyramidalization and migration of an ethylenic hydrogen or phenyl group), and one DHP-like conical intersection along the cyclization coordinate. The isomeric form of the vibrationally hot photoproducts (as determined by measurement 2 ps after photoexcitation) is determined within less than 50 fs of decay to the ground state mediated by passage through a conical intersection. Excess vibrational energy of ground state cis- and trans-stilbene is channelled into phenyl torsions (with mostly opposing directionality). Finally, our simulations are validated by direct comparison to experiment for the absorption spectrum, branching ratio of the three photoproducts (44:52:4 cis-stilbene:trans-stilbene:DHP), and excited state lifetime (520 ± 40 fs).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong, Nonresonant Radiation Enhances Cis–Trans Photoisomerization of Stilbene in Solution

Previously, it has been demonstrated that external electric fields may be used to exert control over chemical reactivity. In this paper, the impact of a strong, nonresonant IR field (1064 nm) on the photoisomerization of cis-stilbene is investigated in cyclohexane solution. The design of a suitable reaction vessel for characterization of this effect is presented. The electric field supplied by the pulsed, near-IR radiation (ε 1 = 4.5 × 10 7 V/cm) enhances the cis → trans photoisomerization yield at the red edge of the absorption spectrum (wavelengths between 337 and 340 nm). Within the microliter focal volume, up to 75% of all cis-stilbene molecules undergo isomerization to trans-stilbene in the strong electric-field environment, indicating a significant increase relative to the 35% yield of trans-stilbene under field-free conditions. This result correlates with a 1–3% enhancement in the trans-stilbene concentration throughout the bulk solution. Theoretical analysis suggests that the observed change is the result of dynamic Stark shifting of the ground and first excited states, leading to a significant redshift in cis-stilbene’s absorption spectrum. The predicted increase in the absorption cross section in this range of excitation wavelengths is qualitatively consistent with the experimental increase in trans-stilbene production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transcriptomic Analysis Reveals Novel Regulators of the Scots Pine Stilbene Pathway

Stilbenes accumulate in Scots pine heartwood where they have important roles in protecting wood from decaying fungi. They are also part of active defense responses, and their production is induced by different (a)biotic stressors. The specific transcriptional regulators as well as the enzyme responsible for activating the stilbene precursor cinnamate in the pathway are still unknown. UV-C radiation was the first discovered artificial stress activator of the pathway. Here, we describe a large-scale transcriptomic analysis of pine needles in response to UV-C and treatment with translational inhibitors, both activating the transcription of stilbene pathway genes. We used the data to identify putative candidates for the missing CoA ligase and for pathway regulators. We further showed that the pathway is transcriptionally activated by phosphatase inhibitor, ethylene and jasmonate treatments, as in grapevine, and that the stilbene synthase promoter retains its inducibility in some of the tested conditions in Arabidopsis, a species that normally does not synthesize stilbenes. Shared features between gymnosperm and angiosperm regulation and partially retained inducibility in Arabidopsis suggest that pathway regulation occurs not only via ancient stress-response pathway(s) but also via species-specific regulators. Understanding which genes control the biosynthesis of stilbenes in Scots pine aids breeding of more resistant trees.

4-Coumarate-CoA ligase↗

Characterization of stilbene-d 12 for neutron spectroscopy without time of flight

In this work, we have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d 12 ) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a 239 PuBe source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d 12 outperforms a 1 H-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d 12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d 12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light output quenching in response to deuterium-ions and alpha particles and pulse shape discrimination in deuterated trans-stilbene

We characterized the light output response of a new 140 cm 3 stilbene-d 12 crystal up to 14.1 MeV neutron energies using a coincidence neutron scattering system. We also characterized its light output response to alpha particles in the 5 to 6 MeV energy range. The excellent PSD capability of the stilbene-d 12 detector allowed us to select light pulses produced by particles of increasing ionization density, namely electrons, protons, deuterium-ions, and alpha particles. The measured fast decay component of the light pulses is increasingly quenched as the ionization density of the particle in the crystal increases. Consistently with this finding, the Birks’ quenching parameter of alpha particles is approximately 8.5 times larger compared to the quenching of deuterium ions, produced by neutron scattering interactions. The reported experimental characterization will allow high-fidelity modeling of the detector enabling its application for fast-neutron detection and spectroscopy in nuclear physics, radiation protection, nuclear security, and non-proliferation.

36 MATERIALS SCIENCE↗

Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods

The neutron-induced light yield of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene) were measured over incident neutron energies from 300 keV to 2.2 MeV and 200 keV to 2.4 MeV, respectively. The measurements were performed using a time-of-flight experiment with a Cf-252 source and an approximately 1.5 m flight path. We compare three light output spectrum full energy deposition edge estimation methods: (1) simulating the neutron energy spectrum edge and fitting it to the light output spectrum, (2) using the inflection point of the light output spectrum edge (derivative method, a.k.a. Kornilov’s method), and (3) using an empirical model fit to the edge of the light output spectrum. Both the derivative and equation fit methods do not account for physical processes such as multiple neutron scattering in the detectors. They instead rely on assumptions about the linear shape continuum shape of the light output spectrum and the direct correlation between the location of the spectrum’s inflection point and maximum energy deposition. These assumptions were found to introduce bias into those methods when tested against simulated spectra with known edge locations. When tested against measured spectra the derivative method was found to differ from the simulation fit by greater than 30% at low energies with large discontinuities for adjacent data points above 800 keV incident neutron energy. The empirical equation fitting method was found to also exhibit bias of a similar magnitude, but with significantly more continuous behavior, especially with the lower count data of the smaller volumed EJ301D scintillator. Experimental light output yield for this neutron energy range is reported using the simulated spectrum fitting method because it includes physics neglected by the other methods, and did not exhibit the bias observed in the other methods

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural dynamics of laser-ionized cis-stilbene studied by ultrafast electron diffraction

Stilbene has been a model system for studying photoisomerization upon absorption of a UV photon. Although the dynamics of the first excited state have been investigated in great detail, the structural dynamics of cationic states remains largely experimentally unexplored. In this study, the dynamics following ionization via absorption of two UV photons was captured using ultrafast electron diffraction. cis-stilbene (CS) was optically pumped with 267 nm ultraviolet light with two different pump fluences and probed with 3.7 MeV electrons. We compare our experimental results to ab-initio multiple spawning simulations for single-photon excitation and molecular dynamics simulations for ionization in order to separate the contributions from the two channels. We found that with a fluence of 170 mJ cm −2 both the single and two-photon channels are present, while with higher fluence of 280 mJ cm −2 the two-photon channel dominates. We did not observe isomerization of the CS cation and found the main structural motion a to be a vibration of the phenyl rings about the central C–C bond.

74 ATOMIC AND MOLECULAR PHYSICS↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light-induced switchable adsorption in azobenzene- and stilbene-based porous materials

Despite the long history of porous materials as adsorbates, fundamental limitations remain regarding the efficient capture and release of the gas molecules, with the working capacity of the material often overlooked. In microporous materials, the uptake is dominated by low-pressure adsorption, with much of this being at pressures below the minimum working threshold for many gas utilization processes. Thus, research has focused on several advances in porous materials, including photoresponsive organic units for light-induced switchable adsorption. This process utilizes light to trigger structural or electronic changes, alter the gas uptake, and change the working capacity. Additionally, while a relatively recent development, there is a significant body of research regarding the use of light to control gas storage performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strength measurement of the $E^{lab}_α = 830$ keV resonance in the 22 Ne (α,n) 25 Mg reaction using a stilbene detector

The interplay between the 22 Ne (α,γ) 26 Mg reaction and the competing 22 Ne ⁢(α,n) 25 Mg reaction determines the efficiency of the latter as a neutron source at the temperatures of stellar helium burning. In both cases, the rates are dominated by the α-cluster resonance at 830 keV. This resonance plays a particularly important role in determining the strength of the neutron flux for both the weak and main s process as well as the n process. Recent experimental studies based on transfer reactions suggest that the neutron and γ-ray strengths for this resonance are approximately equal. In this study, the 22 Ne (α,n) 25 Mg resonance strength has been remeasured and found to be similar to the previous direct studies. Finally, this reinforces an 830 keV resonance strength that is approximately a factor of 3 larger for the 22 Ne ⁢(α,n) 25 Mg reaction than for the 22 Ne (α,γ) 26 Mg reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗