Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Steam seals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Integral Effect Test of ATLAS Facility on Multiple Failure in a Prolonged Station Blackout

Since the Fukushima accident, the design extension conditions (DECs) in a nuclear power plant (NPP) have attracted more importance with respect to nuclear reactor safety, and a consensus has been developed such that these high-risk multiple failure accidents should be revisited from the viewpoint of a reinforcement of the 'defense in depth' concept. In particular, a station blackout (SBO) is one of the most important DECs because a loss of the heat sink without an appropriate accident measure might lead to a core uncovery, core damage, and ultimately, a core meltdown under high pressure. SBO has been recognized to be one of the risk-contributing sequences when combined with additional failure of components such as a reactor coolant pump (RCP) seal leakage or a steam generator tube rupture (SGTR). The RCP seal failure could occur due to a loss of continuous cooling through the seal during SBO. The SGTR during SBO can be a potentially important risk due to the release of the fission product with bypassing the containment boundary. The objective of this study is to experimentally simulate and analyze a prolonged SBO scenario in a thermal hydraulic integral effect test facility, ATLAS. As test items in OECD-ATLAS project, two tests for the SBO condition were conducted with additional failures, that is, a RCP seal failure (A2.1 test) and a SGTR (A2.2 test). In those tests, both the effect of the additional failure on reactor safety and the natural circulation characteristics during prolonged SBO conditions could be investigated. The present test can provide physical insight into the system response during the prolonged SBO scenario combined with the multiple failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transformational Reduction Using Sealing Technology in LCOE Reduction for Coal

GE Power (GEP), in partnership with GE Global Research (GEGR), are working to mature, implement and commercialize sealing technologies for coal-fired steam power plants to reduce the heat rate of a coal-fired plant by 0.6% points and to reduce the installation cost of new plants by about $3.8M. The overall objective is to use sealing technologies to drive a step change in the performance, efficiency, and cost of electricity of new as well as existing coal-based power plants, which aligns with the goals of the DOE. The program objectives are the maturation of sealing technologies to Technology Readiness Level (TRL) 6, followed by their implementation in an existing operating coal-fired steam turbine to validate performance and reach TRL8, and then obtain running experience to reach TRL9 and drive commercialization. These technologies have either already been developed or are being actively developed at lab-scale in ongoing DOE-funded programs and at private expense.

20 FOSSIL-FUELED POWER PLANTS↗

Challenges in practical button cell testing for hydrogen production from high temperature electrolysis of water

High temperature electrolysis of water using solid oxide electrochemical cells (SOEC) is a promising technology for hydrogen production with high energy efficiency and may promote decarbonization when coupled with renewable energy sources and excess heat from nuclear reactors. Over the past several decades there have been extensive scientific and engineering studies on cell materials and degradation behaviors that have greatly improved current density, decreased total resistance, and lowered degradation rates. Although the technology is now at a near-commercial level, maintaining consistency in cell testing and minimizing variance in practical testing environments is an often overlooked but crucial topic. To promote high quality data collection, testing procedures and balance of plant component details are extremely important to consider. This work discusses some key factors affecting the reproducibility of practical SOEC testing on the button cell level, namely, current collection layers, cell sealing procedures, the reliability of steam and hydrogen delivery systems, cell testing fixture design, and reduction procedures. To provide a baseline and a level of standardization for the SOEC community, this work also discloses details of the standard operating procedure and techniques adopted for o-SOEC testing at Idaho National Laboratory (INL).

08 HYDROGEN↗

Ferritic Alloys as Accident Tolerant Fuel Cladding Material for Light Water Reactors

The objective of the GE project is to demonstrate that advanced steels such as iron-chromium-aluminum (FeCrAl) alloys could be used as accident tolerant fuel cladding material in commercial light water reactors. The GE project does not include fuel development. Current findings support the concept that a FeCrAl alloy could be used for the cladding of commercial nuclear fuel. The use of this alloy will benefit the public since it is going to make the power generating light water reactors safer. In the Phase 1A of this cost shared project, GE (GRC + GNF) teamed with the University of Michigan, Los Alamos National Laboratory, Brookhaven National Laboratory, Idaho National Laboratory, and Oak Ridge National Laboratory to study the environmental and mechanical behavior of more than eight candidate cladding materials both under normal operation conditions of commercial nuclear reactors and under accident conditions in superheated steam (loss of coolant condition). The main findings are as follows: (1) Under normal operation conditions the candidate alloys (e.g. APMT, Alloy 33) showed excellent resistance to general corrosion, shadow corrosion and to environmentally assisted cracking. APMT also showed resistance to proton irradiation up to 5 dpa. (2) Under accident conditions the selected candidate materials showed several orders of magnitude improvement in the reaction with superheated steam as compared with the current zirconium based alloys. (3) Tube fabrication feasibility studies of FeCrAl alloys are underway. The aim is to obtain a wall thickness that is below 400 µm. (4) A strategy is outlined for the regulatory path approval and for the insertion of a lead fuel assembly in a commercial reactor by 2022. (5) The GE team worked closely with INL to have four rodlets tested in the ATR. GE provided the raw stock for the alloys, the fuel for the rodlets and the cost for fabrication/welding of the rodlets. INL fabricated the rodlets and the caps and welded them to provide hermetic seal. The replacement of a zirconium alloy using a ferritic material containing chromium and aluminum appears to be the most near term implementation for accident tolerant nuclear fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A graphite oxide (GO)-based remote readable tamper evident seal

Here, this paper presents a prototype of a remotely readable graphite oxide (GO) paper-based tamper evident seal. The proposed device combines the tunable electrical properties offered by reduced graphite oxide (RGO) with a compressive sampling scheme. The benefit of using RGO as a tamper evident seal material is the sensitivity of its electrical properties to the common mechanisms adopted to defeat tamper-evident seals. RGO’s electrical properties vary upon local stress or cracks induced by mechanical action (e.g., produced by shimming or lifting attacks). Further, modification of the seal’s electrical properties can result from the incidence of other defeat mechanisms, such as temperature changes, solvent treatment and steam application. The electrical tunability of RGO enables the engraving of a circuit on the area of the tamper evident seal intended to be exposed to malicious attacks. The operation of the tamper evident seal, as well as its remote communication functionality, is supervised by a microcontroller unit (MCU). The MCU uses the RGO-engraved circuitry to physically implement a compressive sampling acquisition procedure. The compressive sampling scheme provides the seal with self-authentication and self-state-of-health awareness capabilities. Finally, the prototype shows potential for use in low-power, embedded, remote-operation nonproliferation security related applications.

36 MATERIALS SCIENCE↗

Field Test and Evaluation of Engineered Biomineralization Technology for Sealing Existing Wells

This research project addresses one of the goals of the U.S. Department of Energy (DOE) Carbon Storage Program (CSP) aimed at developing Advanced Wellbore Integrity Technologies to Ensure Permanent Geologic Carbon Storage. The technology field-tested in this research project is referred to as microbially induced calcite precipitation (MICP), which utilizes a biologically-based process to precipitate calcium carbonate. If properly controlled MICP can successfully seal fractures, high permeability zones, and compromised wellbore cement in the vicinity of wellbores and in nearby caprock, thereby improving the storage security of geologically-stored carbon dioxide. This report describes an MICP sealing field test performed on a 24.4 cm (9.625 inch) diameter well located on the Gorgas Steam Generation facility near Jasper, Alabama. The research was aimed at (1) developing methods for delivering MICP promoting fluids downhole using conventional oil field technologies and (2) assessing the ability of MICP to seal cement and formation fractures in the near wellbore region in a sandstone formation. Both objectives were accomplished successfully during a field test performed during the period April 1-11, 2014. The test resulted in complete biomineralization sealing of a horizontal fracture located 340.7 m (1118 feet) below ground surface. A total of 24 calcium injections and six microbial inoculation injections were required over a three day period in order to achieve complete sealing. The fractured region was considered completely sealed when it was no longer possible to inject fluids into the formation without exceeding the initial formation fracture pressure. The test was accomplished using conventional oil field technology including an 11.4 L (3.0 gallon) wireline dump bailer for injecting the biomineralization materials downhole. Metrics indicating successful MICP sealing included reduced injectivity during seal formation, reduction in pressure falloff, and demonstration of MICP by-products including calcium carbonate (CaCO 3 ) in treated regions of side wall cores. This project successfully integrated mesoscale laboratory experiments at the Center for Biofilm Engineering (CBE) together with simulation modeling conducted at the University of Stuttgart to develop the protocol for conducting the biomineralization sealing test in the field well.

54 ENVIRONMENTAL SCIENCES↗

Reliability of Materials and Components for Solid Oxide Fuel Cells

Planar stack solid-oxide fuel cells (SOFCs) require seals that must operate reliably under demanding conditions for lifetimes of 40000 hours. This includes temperature fluctuations between 800°C and RT during on and off cycles, thermal stresses, oxidizing environments and chemical degradation to name a few. This comprehensive report provides results from long term testing of two commercially available multicomponent barium alkali silicate glasses: SCN and G6, chosen as sealing candidates. In this scope, the glass seals were deposited on YSZ and Al 2 O 3 substrates simulating electrolytes (Zrbased) and coatings (both zirconia and Al 2 O 3 ). The seal-substrate couples were subjected to 800°C under air and steam+H 2 +N 2 environments up to 40000 hours to test their integrity under real operating conditions. Extensive studies on the effects of exposure have been conducted over the span of testing at various time intervals. Within the context of characterization, mechanical properties such as density, roughness, thermal expansion and glass transition, viscosity and wettability behavior; and microstructural properties such as glass chemistries, defect formation (cracks and pores), phase transformations (devitrification) and glass-interface reactions are investigated. Results and discussions are provided with a focus on the degradation of the properties over long term interrupted testing.

30 DIRECT ENERGY CONVERSION↗

Solid oxide fuel cell power plant having a bootstrap start-up system

The bootstrap start-up system (42) achieves an efficient start-up of the power plant (10) that minimizes formation of soot within a reformed hydrogen rich fuel. A burner (48) receives un-reformed fuel directly from the fuel supply (30) and combusts the fuel to heat cathode air which then heats an electrolyte (24) within the fuel cell (12). A dilute hydrogen forming gas (68) cycles through a sealed heat-cycling loop (66) to transfer heat and generated steam from an anode side (32) of the electrolyte (24) through fuel processing system (36) components (38, 40) and back to an anode flow field (26) until fuel processing system components (38, 40) achieve predetermined optimal temperatures and steam content. Then, the heat-cycling loop (66) is unsealed and the un-reformed fuel is admitted into the fuel processing system (36) and anode flow (26) field to commence ordinary operation of the power plant (10).

30 DIRECT ENERGY CONVERSION↗

Development of Stable Solid Oxide Electrolysis Cells for Low-Cost Hydrogen Production

The project objective was to demonstrate a solid oxide cell-based steam electrolysis stack that exhibits robustness, reliability, endurance, hydrogen purity, and produces hydrogen at elevated pressure of 2 to 3 bar. Innovative materials and processing methods were evaluated to improve degradation characteristics. Performance improvement focused on nearly all layers involved in the cell and stack assembly. Primary attention was paid to zirconia-ceria interface resistance control via sintering optimization and decrease in degradation from the oxygen electrode by evaluating low strontium (Sr) or Sr-free composition for both the oxygen electrode and current collection layer. Stack robustness was addressed by validating redox tolerance of fuel electrode, confirming capability of cells to survive repeated thermal cycles, studying the effect of pressure on performance and degradation, evaluating the effect of contamination on fuel and oxygen electrode performance and degradation, and identifying mitigation strategies to improve performance. The characterization included evaluation of electrochemical performance and stability followed by microstructural analysis. At the cell level, performance and stability improvements were achieved by incorporating a Sr-free oxygen electrode and a denser oxygen electrode barrier layer. At the stack level, pressurized operation reduces demand on first stage compression, the redox tolerant fuel electrode mitigates risk from service interruptions, and improvements to interconnect coating alleviate chromium (Cr) contamination effects. The denser barrier layer was achieved by adding a sintering aid to the samaria-doped ceria (SDC) composition that reduced sintering temperature by 150 °C. The resulting density was on par with the baseline SDC barrier layer density and the lower sintering temperature resulted in less resistive phase formation during sintering. Button cell tests did not demonstrate a change in performance when exposed to silicon (Si) or manganese (Mn) impurities to the fuel electrode and Cr impurity to the oxygen electrode. More detailed study however is warranted. The project addressed SOEC performance and stability at the cell and stack levels through a systematic approach to known sources of degradation that were combined and tested in three stack tests using an electrolyte supported cell design to allow for evaluation of a variety of fuel and oxygen electrode compositions. STK-82 and STK-83 had identical compositions. STK-100 incorporated the best materials and processing variables developed under this and concurrent projects, and was tested at elevated pressure in steam electrolysis. • STK-82 recovered performance after redox and thermal cycling, demonstrating the robustness of the stack and seals. It exhibited stable performance in testing for 500 hours in SOEC mode, followed by 300 hours of cycling between SOEC and SOFC tests. Degradation during SOEC operation was 1.8 %/ 1,000 hours. • STK-83 generated hydrogen at >80% steam conversion, and oxygen above 98.5 % purity during pressurized operation. Both hydrogen and oxygen were generated at 3 barg pressure without the use of a pressure vessel. In addition to balanced pressure, electrolysis operation at 1 bar differential pressure across anode and cathode was also demonstrated to substantial the robustness of the cell and seal. • STK-100 measured at initial ambient pressure conditions showed an area specific resistance of 1.1 ohm-cm 2 , and STK-83 had 1.3 ohm-cm 2 .

08 HYDROGEN↗

Can N95 Respirators Be Reused after Disinfection? How Many Times?

The coronavirus disease 2019 (COVID-19) pandemic has led to a major shortage of N95 respirators, which are essential for protecting healthcare professionals and the general public who may come into contact with the virus. Thus, it is essential to determine how we can reuse respirators and other personal protective equipment in these urgent times. We investigated multiple commonly used disinfection schemes on media with particle filtration efficiency of 95%. Heating was recently found to inactivate the virus in solution within 5 min at 70 °C and is among the most scalable, user-friendly methods for viral disinfection. We found that heat (≤85 °C) under various humidities (≤100% relative humidity, RH) was the most promising, nondestructive method for the preservation of filtration properties in meltblown fabrics as well as N95-grade respirators. At 85 °C, 30% RH, we were able to perform 50 cycles of heat treatment without significant changes in the filtration efficiency. At low humidity or dry conditions, temperatures up to 100 °C were not found to alter the filtration efficiency significantly within 20 cycles of treatment. Ultraviolet (UV) irradiation was a secondary choice, which was able to withstand 10 cycles of treatment and showed small degradation by 20 cycles. However, UV can potentially impact the material strength and subsequent sealing of respirators. Finally, treatments involving liquids and vapors require caution, as steam, alcohol, and household bleach all may lead to degradation of the filtration efficiency, leaving the user vulnerable to the viral aerosols.

60 APPLIED LIFE SCIENCES↗

Ultra High Temperature Anode Recycle Blower for Solid Oxide Fuel Cell (Phase I Final Report)

Under funding from DOE Award DE-FE0031148, Mohawk Innovative Technology, Inc. (MITI) has successfully developed, integrated and tested a prototype ultrahigh speed oil-free blower for use as an Ultra High Temperature Anode Recycle Blower (UHT-ARCB) in a 100 kWe Solid Oxide Fuel Cell (SOFC). MITI’s recycle blower design is hermetically sealed, and features a completely encapsulated permanent magnet motor, which allows it to handle the steam-rich anode recycle gas mixture. At the SOFC’s nominal operating condition, the MITI ARCB rotates at approximately 55000 rpm, raises the pressure of the incoming 621 °C gas from 104 to 112 kPa, and uses less than 1.2 kWe at a rate of approximately 30 g/s. The UHT-ARCB’s thermal management uses the incoming natural gas supply for the SOFC as cooling medium for bearings, seals and motor magnet, along with a water jacket for motor housing cooling to prevent the high temperature gas from affecting the bearing/motor assembly. MITI’s development of this UHT-ARCB will contribute to a reduction of cost and overall balance of plant (BOP) of SOFC systems. The UHT-ARCB recirculates a fraction of the depleted anode exhaust to the fuel-cell inlet. Direct recycling of anode off-gas takes advantage of the water already present in the stream to assist the methane reforming process and inhibit carbon deposition, without the need for an external water supply.

30 DIRECT ENERGY CONVERSION↗

Role of Tartaric Acid in Chemical, Mechanical and Self-Healing Behaviors of a Calcium-Aluminate Cement Blend with Fly Ash F under Steam and Alkali Carbonate Environments at 270 °C

Tartaric acid (TA) changes short-term mechanical behavior and phase composition of sodium-metasilicate activated calcium-aluminate cement blend with fly ash, type F, when used as a set control additive to allow sufficient pumping time for underground well placement. The present work focuses on TA effect on self-healing properties of the blend under steam or alkali carbonate environments at 270 °C applicable to geothermal wells. Compressive strength recoveries and cracks sealing were examined to evaluate self-healing of the cement after repeated crush tests followed by two consecutive healing periods of 10 and 5 days at 270 °C. Optical and scanning electron microscopes, X-ray diffraction, Fourier Transform infrared and EDX measurements along with thermal gravimetric analyses were used to identify phases participating in the healing processes. Samples with 1% mass fraction of TA by weight of blend demonstrated improved strength recoveries and crack plugging properties, especially in alkali carbonate environment. This effect was attributed to silicon-rich (C,N)-A-S-H amorphous phase predominant in TA-modified samples, high-temperature stable zeolite phases along with the formation of tobermorite-type crystals in the presence of tartaric acid.

15 GEOTHERMAL ENERGY↗

Endurance test of helium circulator for HTR-PM - 18531

High-temperature Gas-cooled Reactor Pebble-bed Module (HTR-PM) will be built as the world's first pebble-bed type modular HTGR commercial demonstration plant according to Chinese National science and technology program. HTR-PM will be expected to begin generating electricity in the end of 2017 in Shidao bay of China. Helium circulator is one of critical component of HTR-PM, which circulates reactor coolant through the reactor core and steam generators. The helium circulator was designed to be a vertical layout and its rotor was supported by active magnet bearings (AMBs). The whole circulator including motor and cooler was sealed in a pressure vessel. Since it is a large mechanical and electrical equipment and the design is totally advanced integrated with many new technologies, experiment study of helium circulator would be significant for safe and reliable operation of HTR-PM plant in the future. For the lack of engineering experience of this equipment, it was necessary to manufacture a prototype for tests. Meanwhile, Engineering Test Facility- Helium Circulator. ETF-HC was built in Institute of Nuclear and New Energy Technology (INET) for the tests. The prototype is completely same as the real machine for the plant. After prototype fabrication, nitrogen test was firstly conducted in the factory by the manufacturer, designer and users. After successful factory test, the prototype was delivered to INET to be tested in ETF-HC. Although nitrogen simulation test had been completed successfully, helium endurance test has been continually carried out in ETF-HC for one and half years because of several sealing problems caused by helium. After solving all kinds of problem in the field, helium circulator run continuously 50 hours under rated condition. Furthermore, 50 service cycles test was conducted in ETF-HC. More than 500 operation hours was accumulated during endurance test. Throughout the final performance test, a conclusion can be made that the helium circulator performance met the design requirements and its feasibility, availability and reliability was verified. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experience with Chemical Looping Combustion of Coal in a 200 kW Dual Fluidized Bed Reactor

The University of Utah recently commissioned a dual fluidized bed process development unit (PDU) for investigating chemical looping combustion (CLC) and chemical looping with oxygen uncoupling (CLOU) of coal. The reactors and supporting systems were sized to support at least 200 kW of coal input based on available reaction rate data. Both the air reactor and fuel reactor are circulating fluidized beds and bed material passes between the reactors via loop seals. The reactors are refractory-lined rather than electrically heated, so the system must be preheated with natural gas before chemical looping combustion can begin. Air and steam are preheated through a combination of electric heating and natural gas burners and reactor product gas flows through heat exchangers and bag houses to cool and clean the gas of particulate. As is typical with pilot-scale systems, several operational challenges were encountered as the system was brought online and operation progressed from heatup and initial testing with gaseous fuels towards full CLOU processing of coal. The system hardware and operational procedures have undergone several modifications, but the PDU can now reliably be preheated to the operating temperature and coal can be fed at the target feed rate. This paper presents the PDU, describes the procedures for evaluating carbon conversion, CO2 capture and CO2 purity, and presents initial results from chemical looping combustion of coal with non-CLOU and CLOU carriers. General experience of operating the plant and notable challenges and solutions are also presented.

Whitty, Kevin J.↗

A spatial-statistical investigation of surface expressions associated with cyclic steaming in the Midway-Sunset Oil Field, California

In the Midway Sunset Oil Field in Central California, operators inject steam into the shallow diatomite formation to enhance heavy oil recovery through imbibition, wettability alteration, and viscosity reduction, among other mechanisms. The injected steam, however, does not always remain in the reservoir or return through the wells. In two zones in the study area, the steam comes out at the surface, creating sinkholes, seeps, and steam outlets. These phenomena, called “surface expressions,” pose safety and environmental hazards. Even though these surface expressions are a widespread problem in Central California, they are not well documented and understood. Possible causes of the surface expressions include: high injection pressure, structurally controlled flow patterns, leakage of steam through old improperly abandoned wells, high injection volumes, or flow along naturally occurring faults, among other possible factors. This work examines attributes of the zones with surface expressions in order to determine factors that may contribute to their occurrence. Spatial statistical analysis using logistic regression, random forests, and classification trees is used to explore the relationship between the surface expressions and geological and production-related attributes. The results point to a significant spatial correlation between the surface expressions and two predictors: concentration of plugged wells and geologic seal thickness. The results guide follow-up studies to further investigate the role of well abandonment and seal thickness in the occurrence of surface expressions.

02 PETROLEUM↗

Performance degradation in proton-conducting ceramic fuel cell and electrolyzer stacks

Proton-conducting ceramics are emerging as enabling materials for efficient electrochemical electricity generation, energy storage, and fuels synthesis. In this work, we present longer-term degradation results for protonic-ceramic fuel cells and electrolyzers based on a BaCe 0.4 Zr 0.4 Y 0.1 Yb 0.1 O 3-δ (BCZYYb) electrolyte. The cells are packaged within unit-cell stacks, including metallic interconnects, current collectors, sealing glasses and gaskets. Durability is found to be superior in protonic-ceramic electrolyzers in comparison to fuel cells. Operating conditions have a large impact on degradation rates; better stability is found at fuel-cell operating temperatures above 600 °C, and electrolyzer steam feeds below 20%. Here, we find that both fuel-cell and electrolyzer degradation is greatly reduced via the introduction of a gadolinium-doped ceria interlayer between the electrolyte and the air–steam electrode. Fuel-cell degradation falls to 1.2% khr –1 under methane fuel at 600 °C; electrolyzer degradation is reduced to 1% khr –1 at 550 °C and 50% steam. Further analyses of electrochemical impedance spectroscopy and distribution of relaxation times provide insight to root processes and degradation phenomena in protonic electroceramics.

25 ENERGY STORAGE↗

Corrosion of AISI 310 and 316 in Molten Hydroxide Under Steam Electrolysis Conditions

Steam electrolyzers, utilizing molten hydroxide electrolyte, offers potential for improvement in electrochemical efficiency, cost reduction, use of conventional materials of construction and process scale up for large scale hydrogen production. Stainless steels, used for the fabrication of cell components (current collector, gas separator, wet seals, and manifolds) experience accelerated corrosion in the presence of molten hydroxide electrolyte in both oxidizing (anodic) and reducing (cathodic) atmospheres. In this study, the corrosion behavior of AISI 310 and 316 in hydroxide melt has been studied at 600°C for 50 h. Melt immersion tests revealed formation of the porous lithium iron oxide at the melt-oxide interface for both AISI 310 and 316. Inductively coupled plasma optical emission spectrometry (ICP-OES) analysis showed the presence of Cr in the electrolyte melt obtained from samples exposed to oxidizing atmosphere. Thermochemical analysis was performed to validate the experimental results.

corrosion↗

System code evaluation of near-term accident tolerant claddings during pressurized water reactor station blackout accidents

Following the Fukushima Daiichi nuclear accident in 2011, researches on Accident-tolerant fuels (ATFs) are currently of high interest in not only the nuclear industry but also governmental and international organizations. In this work, a quantitative evaluation of the performance of monolithic FeCrAl cladding and Cr-coated Zircaloy cladding has been performed for Pressurized Water Reactor (PWR) Station Blackout (SBO) accidents. A generic PWR model has been built in system thermal-hydraulics code TRACE based on the Surry Nuclear Power Station with counter-current natural circulation modelling capability for hotleg and steam generator U-tube components during the accidents. The base model results are then compared to MELCOR and RELAP simulations to verify the system component implementation in TRACE. Two PWR SBO scenarios were investigated, including: short-term SBO and long-term SBO with early reactor coolant pump (RCP) seal failure. These scenarios are defined to be very similar to the accidents studied in the State-of-the-Art Reactor Consequence Analysis (SOARCA) project. TRACE code is modified to reflect the oxidation kinetics of FeCrAl and Cr-coating. Larson-Miller creep rupture model is also implemented in TARCE using its built-in control systems to simulate the creep rupture of hotlegs. Additionally, the comparison between the TRACE models with and without the counter-current flow modeling resulted in significant difference when comparing ATF cladding to Zircaloy for short term SBO, while it marginal impacted the performance during long term SBO with RCP seal failure. For short term SBO, both ATF cladding underwent hot leg creep rupture ~20 min after Zircaloy cladding. While Zircaloy and Cr-coated cladding had generated significant amount of hydrogen gas (>10 kg) before the creep rupture event, FeCrAl cladding had only generated <0.5 kg of hydrogen gas. For long term SBO with RCP seal failure, significant hydrogen generation and fuel melting was predicted before hot leg creep rupture for the ATF cladding while providing only 10–20 min additional coping time compared to Zircaloy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗