Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Standards Development, Solid-State Lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Multi-Sensor, Low Volume, Automated Culture System for Space Biology Experiments

Optical density (absorbance) is commonly used in microbiology to measure cell concentration and other colorimetric indicators. It is the main type of bioscience data returned from the BioSentinel small spacecraft mission, which was recently launched as a secondary payload on Artemis I. The flight unit takes absorbance measurements of yeast cultures at 570 nm, 630 nm, and 850 nm to track cell concentration and oxidation-reduction (redox) state of the metabolic indicator dye alamarBlue over time [1]. Because the data returned from a small spacecraft mission is necessarily limited, BioSentinel uses a specialized ground-based experiment apparatus to map the absorbance data onto several other parameters. This culture apparatus is composed of a polycarbonate base and lid which contain ports for several commercial sensors, including a standard 12 mm dissolved oxygen probe, gaseous CO2, fluid pressure, and two micro-probes for measuring pH and redox potential. It also contains a pressure relief valve, a rubber membrane for culture interaction, and a 12mm port for the custom optical probe designed to match in-flight measurements. Modules in two corners expand the culture volume into narrow columns, enabling solid-state optical density measurement and dielectric spectroscopy. The apparatus can be fit to a plate for magnetic stirring. The apparatus’s optical probe allows mapping between the flight unit’s optical data and the additional parameters measured by the ground-based experiments. Within the probe, a linear actuator pulls a plunger, drawing culture volume into the optical path. The actuator then pushes out the plunger and culture volume, cleaning any stray yeast from the inside surface of the probe. The probe chassis is 3D-printed from biocompatible resin with the optoelectronics cured inside an optically clear conformal coat which functions as a lens. To optimize the probe’s dimensions, including optical path, a test harness was developed to manipulate and measure distance while the LED light sources and photodiode detector are in operation. The test harness was composed of two 3/64” thick polycarbonate plates mounted to a set of calipers. The LEDs and photodiode were mounted on the outside of each plate. A cuvette of sample fluid was then clamped between the plates in line between the LEDs and photodiode. The test harness generated a 78% signal change between water and a dye standard for the green (570 nm) LED, a 90% signal change for the red (630 nm) LED, and a 25% signal change between water and overgrown yeast for the infrared (850 nm) LED. The improvements to the ground experiment apparatus (culture volume reduction, inclusion of an optical probe to measure flight-like optical data, and magnetic stirring for culture homogeneity) allow for more flight-like measurements to be taken and more accurate mapping of these additional parameters to the optical data returned from the flight unit. This enhancement to mission science return will give insight into how deep space radiation may affect human biology for future long-term space exploration.

Multi-Sensor↗

An Operational Wake Vortex Sensor Using Pulsed Coherent Lidar

NASA and FAA initiated a program in 1994 to develop methods of setting spacings for landing aircraft by incorporating information on the real-time behavior of aircraft wake vortices. The current wake separation standards were developed in the 1970's when there was relatively light airport traffic and a logical break point by which to categorize aircraft. Today's continuum of aircraft sizes and increased airport packing densities have created a need for re-evaluation of wake separation standards. The goals of this effort are to ensure that separation standards are adequate for safety and to reduce aircraft spacing for higher airport capacity. Of particular interest are the different requirements for landing under visual flight conditions and instrument flight conditions. Over the years, greater spacings have been established for instrument flight than are allowed for visual flight conditions. Preliminary studies indicate that the airline industry would save considerable money and incur fewer passenger delays if a dynamic spacing system could reduce separations at major hubs during inclement weather to the levels routinely achieved under visual flight conditions. The sensor described herein may become part of this dynamic spacing system known as the "Aircraft VOrtex Spacing System" (AVOSS) that will interface with a future air traffic control system. AVOSS will use vortex behavioral models and short-term weather prediction models in order to predict vortex behavior sufficiently into the future to allow dynamic separation standards to be generated. The wake vortex sensor will periodically provide data to validate AVOSS predictions. Feasibility of measuring wake vortices using a lidar was first demonstrated using a continuous wave (CW) system from NASA Marshall Space Flight Sensor and tested at the Volpe National Transportation Systems Center's wake vortex test site at JFK International Airport. Other applications of CW lidar for wake vortex measurement have been made more recently, including a system developed by the MIT Lincoln Laboratory. This lidar has been used for detailed measurements of wake vortex velocities in support of wake vortex model validation. The first measurements of wake vortices using a pulsed, lidar were made by Coherent Technologies, Inc. (CTI) using a 2 micron solid-state, flashlamp-pumped system operating at 5 Hz. This system was first deployed at Denver's Stapleton Airport. Pulsed lidar has been selected as the baseline technology for an operational sensor due to its longer range capability.

Barker, Ben C., Jr.↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗