Extended Life PZT Stack Test Fixture

Piezoelectric stacks are being sought to be used as actuators for precision positioning and deployment of mechanisms in future planetary missions. Beside the requirement for very high operation reliability, these actuators are required for operation at space environments that are considered harsh compared to normal terrestrial conditions.These environmental conditions include low and high temperatures and vacuum or high pressure. Additionally, the stacks are subjected to high stress and in some applications need to operate with a very long lifetime durability.Many of these requirements are beyond the current industry design margins for nominal terrestrial applications. In order to investigate some of the properties that will indicate the durability of such actuators and their limitations we have developed a new type of test fixture that can be easily integrated in various test chambers for simulating environmental conditions, can provide access for multiple measurements while being exposed to adjustable stress levels. We designed and built two test fixtures and these fixtures were made to be adjustable for testing stacks with different dimensions and can be easily used in small or large numbers. The properties that were measured using these fixtures include impedance, capacitance, dielectric loss factor, leakage current, displacement, breakdown voltage, and lifetime performance. The fixtures characteristics and the test capabilities are presented in this paper.

test fixtures

Solid oxide electrolysis cell and stack testing best practices

Solid oxide electrolyzer (SOE) technology is an emerging method for hydrogen production, noted for its superior electrical efficiency. Despite the significant progress made in recent years, the broad development of SOE technology is often constrained by the necessary and extensive "skill of the craft" required to successfully test simple single cell test articles. This may be linked to the dearth of practical and pragmatic guidance within the literature for safe, reliable, and performant test equipment and test procedures. Researchers at the Idaho National Laboratory (INL) have been actively testing SOEs ranging from button cells to stacks up to 500 kW, in collaboration with industry and other national laboratories. Based on operational experience, INL has developed system design procedures that ensure safe and reliable operation of SOE systems with the level of support required for each test. This paper presents key aspects of SOE stack and system testing, including safe design procedures, balance of plant components design, and specific implementations at INL. Practical design details of reactants, heat, and power management are presented along with lessons learned from the SOE test facility operations at INL.

08 HYDROGEN

Stack Test Summary for TA-59-0001

The Radioactive Air Emissions Management (RAEM) team performed stack flow characterization tests at Technical Area (TA) 59 Building 0001 Exhaust Stack (ES) 8. These tests were completed in accordance with Title 40 of the Code of Federal Regulations (CFR), Part 61, Subpart H and the American National Standards Institute (ANSI) N13.1-1999 required by the Clean Air Act. Subpart H of the regulation is the National Emission Standards for Hazardous Air Pollutants (NESHAP) for radionuclides, which compliance with is maintained by the REAM team.

54 ENVIRONMENTAL SCIENCES

Ares I-X Flight Test Vehicle:Stack 1 Modal Test

Ares I-X was the first flight test vehicle used in the development of NASA s Ares I crew launch vehicle. The Ares I-X used a 4-segment reusable solid rocket booster from the Space Shuttle heritage with mass simulators for the 5th segment, upper stage, crew module and launch abort system. Three modal tests were defined to verify the dynamic finite element model of the Ares I-X flight test vehicle. Test configurations included two partial stacks and the full Ares I-X flight test vehicle on the Mobile Launcher Platform. This report focuses on the second modal test that was performed on the middle section of the vehicle referred to as Stack 1, which consisted of the subassembly from the 5th segment simulator through the interstage. This report describes the test requirements, constraints, pre-test analysis, test operations and data analysis for the Ares I-X Stack 1 modal test.

Buehrle, Ralph D.

Ares I-X Flight Test Vehicle: Stack 5 Modal Test

Ares I-X was the first flight test vehicle used in the development of NASA's Ares I crew launch vehicle. The Ares I-X used a 4-segment reusable solid rocket booster from the Space Shuttle heritage with mass simulators for the 5th segment, upper stage, crew module and launch abort system. Three modal tests were defined to verify the dynamic finite element model of the Ares I-X flight test vehicle. Test configurations included two partial stacks and the full Ares I-X flight test vehicle on the Mobile Launcher Platform. This report focuses on the first modal test that was performed on the top section of the vehicle referred to as Stack 5, which consisted of the spacecraft adapter, service module, crew module and launch abort system simulators. This report describes the test requirements, constraints, pre-test analysis, test operations and data analysis for the Ares I-X Stack 5 modal test.

Buehrle, Ralph D.

Space Shuttle Partial Stack Rollout Test Analytical Correlation In Support Of Fatigue Load Development

A rollout test with only the Solid Rocket Boosters was conducted in November 2003 to gather structural dynamic response data of the transportation environment from the Vehicle Assembly Building to the Launch Pad. The data was acquired to develop and validate analytical methods used to predict rollout Orbiter fatigue load spectra. Earlier predictions computed by a base drive approach with only 5 input drive degrees-of-freedom raised questions that commissioned the partial stack test. Not only was there a concern because of the input degree-of-freedom omission due to measurement limitations, but there was also a concern with the implementation of the "large mass" itself. Three methods were evaluated with the partial stack test data. The analytical correlations to measured strain derived SRB base loads and acceleration5 showed the earlier 5 degree-of-freedom base drive approach to yield the most conservative results for all quantities monitored except the SRB base moment about the axis in which the input drive was missing. This non-conservative shortcoming led to a recommendation to use either the 6 degree-of-freedom base drive or the 12 degree-of-freedom Craig-Bampton boundary drive methods whose results did not substantially differ.

DelBasso, Steve

Pulse: An Outlier Sensitive Downsampling Algorithm For Timeseries Data

Pulse is a downsampling algorithm for timeseries data. Frequently datasets become so large that visualization tools and web browsers cannot effectively render graphics due to memory constraints. Downsampling algorithms are commonly applied to minimize the quantity of data required to visualize important features or trends in the data, but some datasets are composed by distinct enough features and trends that most existing downsampling algorithms fail to preserve them. Pule was developed to downsample timeseries data for galvanostatic stack test data at the Idaho National Laboratory. These datasets were composed by approximately 4 million records, most of them being extremely uniform. However, during relatively brief time periods when the stack test changes state, for example when the test article is powered on, or a load is added, the data produce sparse asymptotes. No existing downsampling algorithm was capable of preserving the sparse asymptotes in electrolysis stack test data. Instead, we develop a downsampling algorithm that preserves important outliers in data, and otherwise aggressively downsamples uniform data. The algorithm has applications in other domains like seismology, in the measurement of earthquakes, or astronomy, in the measurement of quasars or transit photometry.

Woodruff, Nathan [Idaho National Laboratory (INL),

Evaluation of Significance Tests on Stack Sample Data

In October 2023, external assessors visiting LANL’s Rad-NESHAP team reviewed the annual source term documentation package for stack emissions. This document discusses how the team uses significance tests to determine whether or not a measurement represents an actual detection of emitted radioactive material. The significance tests used in the evaluation compare the measured sample result to the Minimum Detectable Activity (MDA) for the sample; to the uncertainty of that measurement; and to the mean blank sample for the same time period. The blank test uses the average blank plus 2-standard deviations (2σ) of the blank results as a comparison threshold for this final evaluation.

54 ENVIRONMENTAL SCIENCES

Solid polymer membrane program

The results are presented for a solid polymer electrolyte fuel cell development program. Failure mechanism was identified and resolution of the mechanism experienced in small stack testing was demonstrated. The effect included laboratory analysis and evaluation of a matrix of configurations and operational variables for effects on the degree of hydrogen fluoride released from the cell and on the degree of blistering/delamination occurring in the reactant inlet areas of the cell and to correlate these conditions with cell life capabilities. The laboratory evaluation tests were run at conditions intended to accelerate the degradation of the solid polymer electrolyte in order to obtain relative evaluations as quick as possible. Evaluation of the resolutions for the identified failure mechanism in space shuttle configuration cell assemblies was achieved with the fabrication and life testing of two small stack buildups of four cell assemblies and eight cells each.

Source record

NASA Non-Flow-Through PEM Fuel Cell System for Aerospace Applications

NASA is researching passive NFT Proton Exchange Membrane (PEM) fuel cell technologies for primary fuel cell power plants in air-independent applications. NFT fuel cell power systems have a higher power density than flow through systems due to both reduced parasitic loads and lower system mass and volume. Reactant storage still dominates system mass/volume considerations. NFT fuel cell stack testing has demonstrated equivalent short term performance to flow through stacks. More testing is required to evaluate long-term performance.

Araghi, Koorosh R.

Demonstration of Passive Fuel Cell Thermal Management Technology

The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA Exploration program. The passive thermal management system relies on heat conduction within highly thermally conductive cooling plates to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack. Using the passive approach eliminates the need for a coolant pump and other cooling loop components within the fuel cell system which reduces mass and improves overall system reliability. Previous development demonstrated the performance of suitable highly thermally conductive cooling plates and integrated heat exchanger technology to collect the heat from the cooling plates (Ref. 1). The next step in the development of this passive thermal approach was the demonstration of the control of the heat removal process and the demonstration of the passive thermal control technology in actual fuel cell stacks. Tests were run with a simulated fuel cell stack passive thermal management system outfitted with passive cooling plates, an integrated heat exchanger and two types of cooling flow control valves. The tests were run to demonstrate the controllability of the passive thermal control approach. Finally, successful demonstrations of passive thermal control technology were conducted with fuel cell stacks from two fuel cell stack vendors.

Burke, Kenneth A.

Fuel cell technology program

A fuel cell technology program was established to advance the state-of-the-art of hydrogen-oxygen fuel cells using low temperature, potassium hydroxide electrolyte technology as the base. Program tasks are described consisting of baseline cell design and stack testing, hydrogen pump design and testing, and DM-2 powerplant testing and technology extension efforts. A baseline cell configuration capable of a minimum of 2000 hours of life was defined. A 6-cell prototype stack, incorporating most of the scheme cell features, was tested for a total of 10,497 hours. A 6-cell stack incorporating all of the design features was tested. The DM-2 powerplant with a 34 cell stack, an accessory section packaged in the basic configuration anticipated for the space shuttle powerplant and a powerplant control unit, was defined, assembled, and tested. Cells were used in the stack and a drag-type hydrogen pump was installed in the accessory section. A test program was established, in conjunction with NASA/JSC, based on space shuttle orbiter mission. A 2000-hour minimum endurance test and a 5000-hour goal were set and the test started on August 8, 1972. The 2000-hour milestone was completed on November 3, 1972. On 13 March 1973, at the end of the thirty-first simulated seven-day mission and 5072 load hours, the test was concluded, all goals having been met. At this time, the DM-2 was in excellent condition and capable of additional endurance.

Source record

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS

Scale-Up of Electrode Coating and Flow-Field for Commercial Hydrogen Peroxide Electrolyzer: Cooperative Research and Development Final Report, CRADA Number CRD-17-00687

Hydrogen peroxide is currently produced at central chemical plants via the anthraquinone oxidation process. This process produces environmental pollutants that are costly to remediate, requires hazardous long distance shipping of highly concentrated peroxide (50% or 70%), and necessitates extra handling costs related to storage and dilution. Peroxygen Systems, Inc. (PSi) is developing breakthrough technology for on-site hydrogen peroxide production. PSi’s on-site on-demand electrolyzer can reduce the cost of producing hydrogen peroxide by 50%, while also completely eliminating the cost and safety issues associated with shipping and handling of high concentration hydrogen peroxide. The challenge for PSi is scaling. To support the next step toward commercialization (customer pilot tests), scaling the prototype into larger single cells and 20-40 cell stacks is required. In addition to internal hardware and flow-field design efforts at PSi, NREL will address three critical problems for this scale-up effort: (1) demonstrating a large scale roll-to-roll (R2R) process to coat uniform electrode materials for 100 cm2 and 500 cm2 stack testing, (2) demonstrating an in-line diagnostic to achieve better electrode quality control, and (3) performing in situ cell/stack testing to better understand and optimize the performance of the flow field design.

28 EE - Advanced Manufacturing Office (EE-5A)

Plated wire memory subsystem

The design, construction, and test history of a 4096 word by 18 bit random access NDRO Plated Wire Memory for use in conjunction with a spacecraft input/output and central processing unit is reported. A technical and functional description is given along with diagrams illustrating layout and systems operation. Test data is shown on the procedures and results of system level and memory stack testing, and hybrid circuit screening. A comparison of the most significant physical and performance characteristics of the memory unit versus the specified requirements is also included.

Carpenter, K. H.

Offshore Wind to Hydrogen - Modeling, Analysis, Testing and International Collaboration Work

This project explores electrolytic hydrogen production from an offshore wind turbine by: Modeling: Simulate an offshore wind turbine and generate power output profiles; Analysis: Analyze offshore conditions and determine operational modes of the stack; Testing: Perform hardware testing to evaluate dynamic characteristics; and International Collaboration Work: Share learnings and publish. Potential Outcomes: Accelerate development of an integrated, in-turbine offshore wind hydrogen system; and Support two DOE Energy Earthshots - Hydrogen and Floating Offshore Wind.

electrolyzer

Primary and secondary electrical space power based on advanced PEM systems

For new space ventures, power continues to be a pacing function for mission planning and experiment endurance. Although electrochemical power is a well demonstrated space power technology, current hardware limitations impact future mission viability. In order to document and augment electrochemical technology, a series of experiments for the National Aeronautics and Space Administration Lewis Research Center (NASA LeRC) are underway at the Los Alamos National Laboratory that define operational parameters on contemporary proton exchange membrane (PEM) hardware operating with hydrogen and oxygen reactants. Because of the high efficiency possible for water electrolysis, this hardware is also thought part of a secondary battery design built around stored reactants - the so-called regenerative fuel cell. An overview of stack testing at Los Alamos and of analyses related to regenerative fuel cell systems are provided in this paper. Finally, this paper describes work looking at innovative concepts that remove complexity from stack hardware with the specific intent of higher system reliability. This new concept offers the potential for unprecedented electrochemical power system energy densities.

Vanderborgh, N. E.

Cell module and fuel conditioner

Stack tests indicate that the discrepancies between calculated and measured temperature profiles are due to reactant cross-over and a lower than expected thermal conductivity of cells. Preliminary results indicate that acceptable contact resistance between cooling plane halves can be achieved without the use of paper. The preliminary design of the enclosure, definition of required labor and equipment for manufacturing repeating components, and the assembly procedures for the benchwork design were developed. Fabrication of components for a second 5-cell stack of the MK-2 design and a second 23-cell stack of the MK-1 design was started. The definition of water and fuel for the reforming subsystem was developed along with a preliminary definition of the control system for the subsystem. The construction and shakedown of the differential catalytic reactor was completed and testing of the first catalyst initiated.

Hoover, D. Q., Jr.