Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Spacecraft separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve

Estimating Interplanetary Magnetic Field Conditions at Mercury's Orbit From MESSENGER Magnetosheath Observations Using a Feedforward Neural Network

Abstract Mercury's small magnetosphere is embedded in the dynamic and intense solar wind environment characteristic of the inner heliosphere. Both the magnitude and orientation of the interplanetary magnetic field (IMF) significantly influence the solar wind‐magnetospheric interaction at Mercury, driving phenomena such as magnetic reconnection. The MErcury Surface, Space Environment, Geochemistry and Ranging (MESSENGER) spacecraft provided in‐situ magnetic field measurements of the solar wind, the magnetosheath, and the magnetosphere along each orbit. However, it is a challenge to directly assess the IMF's impact on Mercury's plasma environment due to the temporal separation between observations within the solar wind and the magnetosphere, especially in the absence of an upstream monitor. Here, we present a feedforward neural network (FNN) trained on a subset of magnetosheath observations to estimate the strength and orientation of the IMF upstream of the bow shock. Utilizing magnetosheath magnetic field, cylindrical spatial coordinates, and heliocentric distance measurements, the FNN predicts upstream IMF conditions with an score of 0.70 and mean averaged error of 5.3 nT, thereby greatly decreasing the temporal separation between IMF estimates and magnetospheric measurements throughout the MESSENGER mission. This approach yields IMF estimates for all magnetosheath data measured by MESSENGER, providing a useful tool for future investigations of the IMF impact on Mercury's magnetosphere. This method will be integrable with the dual‐spacecraft BepiColombo magnetosheath measurements, providing useful estimates of upstream IMF conditions particularly during the extended periods in which neither spacecraft sample the solar wind. Our results demonstrate the utility of machine learning techniques on advancing space science research.

Bowers, Charles F.

Comparison of the Distribution of the In Situ Ring Current Density Based on Magnetic Field Observations From THEMIS, MMS and Cluster

Abstract We review and extend previous work on the ring current density distribution by applying the curlometer technique to multi‐spacecraft magnetic field data on different spatial scales, directly comparing the results of three space missions: Time History of Events and Macroscale Interactions during Substorms (THEMIS), The Magnetospheric Multiscale (MMS) and Cluster, that have so far accrued decades of data on a range of spatial separation scales. We suggest that the statistical results of Cluster data over two decades can illustrate well the overall form of the ring current (in the ring plane), but can underestimate the current density, while THEMIS (partially) and MMS are able to observe the detailed structure of the ring current and indeed show different behavior on some (smaller) spatial scales. These results suggest that, in addition to the local time and radial form, reported previously, the morphology of the ring current may also depend on magnetic latitude, as influenced by the tilt angle between the inner and outer magnetic fields.

Tan, X. [School of Space and Earth Sciences Beihan

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics