Solid Sorbent Cost Sensitivity Analysis: A Framework for UNF Reprocessing Sorbent Cost Comparison
Solid sorbents have been the subject of research and development across the U.S. Department of Energy national laboratory complex for many years. They are generally accepted as a safer alternative to cryogenic distillation for noble gas capture, and they present an easier pathway in development of long-term waste forms after iodine capture. As more types of sorbents have been proposed for capture of volatile radionuclides, it has become necessary to compare them based on performance and cost criteria. This report details cost and performance information for three promising sorbents and provides a cost sensitivity analysis. The goal of this analysis is to establish a framework which can be utilized to directly compare future sorbents, with differing properties, to the sorbents discussed in this report. Direct comparison is instrumental to making informed decisions to efficiently guide research and minimize laborious detours. In all cases, sorbent capacity is a major cost driver as it influences the mass of sorbent, operational footprint, and disposal cost requirements., However, sorbent price can greatly increase the cost of a capture technology. For sorbents used in krypton capture, the purity of krypton released to storage is the highest cost driver.